HomeMy WebLinkAboutM401 DIAGRAMS.pdfREQUIRED.CABLE OR AS24" STANDARDSUPPLY DIFFUSER BALANCE DAMPERSADJUSTS WITH 1/4" NUTDRIVERSPECIFY OPTIONAL SCREWDRIVERTIP IF LESS THAN 3/8" CLEARACCESS.NO SCALEROUND DAMPERPLENUMADJUSTABLE MOUNTING CLAMPDIFFUSERTAKE-OFFAS REQ.INSULATED SUPPLYAIR PLENUM.2-WAY COIL PIPING DIAGRAMNO SCALECOIL:1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAININGFANS OR COMPRESSORS, NOT REQ'D FOR EQUIPMENT SUCH ASDUCT COILS.2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERSMOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL).3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION.4. 2-WAY VALVE NORMALLY OPEN FOR HEATING AND NORMALLYCLOSED FOR COOLING.STRAINER WITHBLOWDOWNAND CAP.MANUAL AIR VENTAT HIGHEST POINTIN PIPING.RETURNSUPPLYTHRU ROOF DIAGRAMDRYER VENTNO SCALESTORM COLLAR/COUNTERFLASHING. SEALTO DUCT.MEMBRANE,INSULATION,FLASHING,ETC.LONG RADIUS ELBOW.FULLY WELDED CURB CAP,SIMILAR TO TRANSITION.TIGHT TO, BUT NOTFASTENED TO DUCT.PREFAB, INSULATEDROOF CURB WITHTREATED WOODNAILER.SUPPORT DUCT FROMSTRUCTURE.DRYER VENT CAP W/BACKDRAFT DAMPER.COIL PIPING DIAGRAMNO SCALE:1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAININGFANS OR COMPRESSORS, NOT REQ'D FOR EQUIPMENT SUCH ASDUCT COILS.2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERSMOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL).3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION.4. 3-WAY VALVE WITH COIL RETURN PIPED TO NORMALLY OPEN PORTFOR HEATING AND NORMALLY CLOSED PORT FOR COOLING.MANUAL AIR VENTAT HIGHEST POINTIN PIPING.STRAINER WITHBLOWDOWNVALVE AND CAP.SUPPLYRETURN3-WAY (DIVERTING VALVE) SNOWMELT HEAT EXCHANGER AND PUMP PIPING DIAGRAMNO SCALESMSSMSSMRSMRHWRTO HEATINGWATER SYSTEM.HEAT EXCHANGERSNOWMELT PUMP, SUPPORT FROM WALL ORFLOOR AS REQUIRED.ROUTE PIPE INDIRECT TOFLOOR DRAIN.EXPANSION TANK.HOSE END VALVE FOR GLYCOLFILL.AIR PURGER ASSEMBLY.SMS/SMRHWSSNOWMELT CONNECTION: STAIR TO WALK DIAGRAMNO SCALE9" O.C. TYP. FOR ALLLANDINGS & WALKS.HYDRONIC SNOWMELTTUBING.6" O.C. TYP. FOR ALLSTAIRS.DDOMESTIC WATER HEATER PIPING DIAGRAMNO SCALEAHWRHWSS(SIDEARM)HW TO FIXTURES.COLD WATER SUPPLY.HWC FROM FIXTURES.DIAPHRAGM TYP.EXPANSION TANK.AMTROL OR EQUIV.RELIEF VALVE, PIPEINDIRECT TO FLOORDRAIN.DOMESTIC HOTWATER RECIRCPUMPWATER HEATER.2" HWS/R, TYP.DAHWRHWSS3/4"EFBJGADGOOSENECK DIAGRAMNO SCALE135°SPOT WELD REINFORCINGANGLE.NUT & BOLT.:STIFFENERS MAY BEREQ'D BASED ON SIZEFOR WIND/SEISMIC LOADS.BIRDSCREENFRAME.DUCT SIZEPLUS 25%.1/4" SCREEN.20" MIN.FLASHING ANDCOUNTERFLASHING.12" MIN.14" MIN.COOR'D ROOF PENETRATIONWITH ROOF MANUFACTURER.HGAS PIPING ONE-LINE DIAGRAMNO SCALECUPPER MASTERFIREPLACE38 MBH/47 CFHM0.5 PSIDISCHARGE.2,206 CFH,205 FT, 4"150 FT, 3/4"1-1/4"1-1/4"3/4"2,159 CFH,205 FT, 4"BOILER ,399 MBH/493 CFHBOILER ,399 MBH/493 CFHBOILER ,399 MBH/493 CFH85 FT, 1,479CFH, 2-1/2"1-1/2" TOEACHBOILERMAIN LEVELMASTER FP38 MBH/47 CFH680 CFH,2-1/2"KITCHEN RANGE90 MBH/112 CFHBBQ90 MBH/112 CFH630 CFH145 FT,3/4"140 FT,1"521 CFH,2"160 FT,1-1/4"409 CFHLIVING RM FP90 MBH/112 CFHGAME RM FP90 MBH/112 CFH170 FT,1-1/4"OUTDOORFP150 MBH/185 CFH205 FT,3/4"170 FT,1-1/4"PROVIDE AUTOMATICSHUT-OFF CONTROLWITH MAX. 30 MIN.TIMER.:1. SCH. 40 METALLIC PIPE.2. 0.3 IN. W.C. AP.3. RESIDENCES A AND B HAVE SAME GASROUTING; WORST CASE PIPE LENGHTSTO EACH FIXTURE USED.SINGLE BLADEDAMPER IF H<8"OPPOSED BLADEDAMPER IF H>=8"NOTE:CEILING DIFFUSERSHOWN. FLOORDIFFUSER SIMILAR.END BEARING182 WEST MEADOW DRIVEVAIL, CO 81657PIETRINI RESIDENCEProject Number - 142807/30/14DESIGN REVIEWCOPYRIGHT 2014BANZEGEAUDIN(970) 949-6108(303) 278-3820(970) 221-5691(505) 323-9070(307) 739-3944Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com09/05/14PERMIT SETM4.01MECHANICALDIAGRAMS