Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A000.pdf
1A5.011A5.11SHEET NUMBERDRAWING NUMBERSHEET NUMBERDRAWING NUMBERSHEET NUMBERDRAWING NUMBERBUILDING SECTION IDENTIFICATIONWALL SECTION IDENTIFICATION1A9.01SHEET NUMBERDRAWING NUMBERDETAIL IDENTIFICATIONINTERIOR ELEVATION IDENTIFICATION1A6.01SHEET NUMBERDRAWING NUMBERENLARGED DETAIL IDENTIFICATIONAREA OF DRAWING TOBE ENLARGEDSECTION MATERIALGRAPHICS23A76HPARTITION TYPE; RE:PARTITION TYPE SCHEDULEPARTITION TYPE; RE:PARTITION TYPE SCHEDULEPARTITION TYPE IDENTIFICATIONACOUSTICAL PARTITION TYPE IDENTIFICATION308DOOR NUMBERDOOR IDENTIFICATIONROOM NAME314876.00 SFROOM NUMBERROOM/SPACE/AREA IDENTIFICATIONROOM NAMEROOM AREAA1COLUMN LETTERCOLUMN LETTERCOLUMN REFERENCEGUIDESTRUCTURAL GRIDELEVATIONLEVEL NAMEBATT INSULATIONCONCRETEUNDISTURBED ORCOMPACTED EARTHPOROUS FILL(GRAVEL)STEELALUMINUMMASONRY - BRICKMASONRY -CONCRETE BLOCKRIDGID INSULATIONGYPSUM PLASTERPLYWOODFINISH WOODEXTERIOR ELEVATION IDENTIFICATION1A4.01A7.0199999999C1WINDOW TYPESHEET NUMBERDRAWING NUMBER?WINDOW IDENTIFICATIONKEYNOTE IDENTIFICATIONNOTE NUMBER001ASIREVISION IDENTIFICATIONREVISION NUMBERREVISION DESCRIPTIONELEVATION DATUM IDENTIFICATIONSHEET INDEX SCALEA000 COVER SHEET NTS.TOPOGRAPHIC SURVEY 1"=10'LANDSCAPEL 1.0 LANDSCAPE SITE PLAN 1/8"=1'-0"L 2.0 LANDSCAPE PLANTING PLAN 1/8"=1'-0"L3.0 LANDSCAPE AREA CALCULATIONS 1/8"=1'-0"ARCHITECTURALA100 LEVEL 1 FLOOR PLAN 1/4"=1'-0"A100B LEVEL 1 FRAMING PLAN 1/4"=1'-0"A101 LEVEL 2 FLOOR PLAN 1/4"=1'-0"A101B LEVEL 2 FRAMING PLAN 1/4"=1'-0"A102 LEVEL 3 FLOOR PLAN 1/4"=1'-0"A102B LEVEL 3 FRAMING PLAN 1/4"=1'-0"A103 ROOF PLAN 1/4"=1'-0"A150 LEVEL 1 RCP 1/4"=1'-0"A151 LEVEL 2 RCP 1/4"=1'-0"A152 LEVEL 2 RCP 1/4"=1'-0"A153 LEVEL 1 POWER PLAN 1/4"=1'-0"A154 LEVEL 2 POWER PLAN 1/4"=1'-0"A155 LEVEL 3 POWER PLAN 1/4"=1'-0"A200 ELEVATIONS 1/4"=1'-0"A201 ELEVATIONS 1/4"=1'-0"A300 BLDG. SECTIONS 1/4"=1'-0"A301 BLDG. SECTIONS 1/4"=1'-0"A302 BLDG. SECTIONS 1/4"=1'-0"A303 BLDG. SECTIONS 1/4"=1'-0"A304 BLDG. SECTIONS 1/4"=1'-0"A305 BLDG. SECTIONS 1/4"=1'-0"A500 EXT. DETAILS VARIESA501 EXT. DETAILS VARIESA502 EXT. DETAILS 1-1/2"=1'-0"A503 WINDOW/DOOR DETAILS 1-1/2"=1'-0"A600 WINDOW TYPES + SCHED. 1/4"=1'-0"A601 WINDOW TYPES + SCHED. 1/4"=1'-0"A602 WINDOW TYPES + SCHED. 1/4"=1'-0"MECHANICALM001 MECHANICAL LEGENDS NTSM002 MECHANICAL SCHEDULES NTSM003 MECHANICAL SCHEDULES NTSSHEET INDEX SCALEM100 MECHANICAL SITE PLAN 3/16"=1'-0"M101 LEVEL 1 PIPING PLAN 1/4"=1'-0"M102 LEVEL 2 PIPING PLAN 1/4"=1'-0"M103 LEVEL 3 PIPING PLAN 1/4"=1'-0"M201 LEVEL 1 HVAC PLAN 1/4"=1'-0"M202 LEVEL 2 HVAC PLAN 1/4"=1'-0"M203 LEVEL 3 HVAC PLAN 1/4"=1'-0"M301 LEVEL 1 PLUMBING PLAN 1/4"=1'-0"M302 LEVEL 2 PLUMBING PLAN 1/4"=1'-0"M303 LEVEL 3 PLUMBING PLAN 1/4"=1'-0"M400 ENLARGED MECHANICAL PLAN 3/8"=1'-0"M500 MECHANICAL DIAGRAMS NTSM501 MECHANICAL DIAGRAMS NTSM502 MECHANICAL DIAGRAMS NTSSTRUCTURALS001 NOTES NTSS002 NOTES NTSS003 NOTES NTSS100 LEVEL 1 FLOOR PLAN 1/4"=1'-0"S101 LEVEL 2 FLOOR PLAN 1/4"=1'-0"S102 LEVEL 3 FLOOR PLAN 1/4"=1'-0"S103 ROOF PLAN 1/4"=1'-0"S200 PARTIAL PLAN 1/2"=1'-0"S300 TYP. CONCRETE DETAILS NTSS310 TYP. FOUNDATION DETAILS VARIESS311 TYP. FOUNDATION DETAILS VARIESS320 SOG DETAILS VARIESS500 STEEL DETAILS NTSS501 STEEL DETAILS VARIESS600 TYP. WOOD DETAILS NTSS601 TYP. WOOD DETAILS NTSS602 TYP. WOOD DETAILS NTSS603 SHEAR WALL DETAILS NTSS610 FLOOR DETAILS VARIESS611 FLOOR DETAILS NTSS620 ROOF DETAILS VARIESABBREVIATIONSMATL MATERIALMAX MAXIMUMMECH MECHANICALMEP MECHANICAL, ELECTRICAL and PLUMBINGMTL METALMFR MANUFACTURERMIN MINIMUMMIRR MIRRORMISC MISCELLANEOUSMEMB MEMBRANEMTD MOUNT(ED)MUL MULLIONMED MEDIUMMAG MAGNETICMM MILLIMETERSMEZZ MEZZANINEMB MOISTURE BARRIERNNORTH(N) NEWNIC NOT IN CONTRACTNTS NOT TO SCALENO NUMBERNOM NOMINALOA OVERALLOC ON CENTEROD OUTSIDE DIAMETEROTO OUTSIDE-TO-OUTSIDEOFF OFFICEOH OPPOSITE HANDOPNG OPENINGOPP OPPOSITEOF OUTSIDE FACEPC PRECASTPAC PREVIOUSLY AWARDED CONTRACTP/L PROPERTY LINEPLAM PLASTIC LAMINATEPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT POST TENSIONED or PORCELAIN TILEPVC POLYVINYL CHLORIDEPLYWD PLYWOODPREFAB PREFABRICATEDPL PLATEPLAS PLASTERPNL PANELP PAINT(ED)PR PAIR or PROPOSAL REQUESTPROJ PROJECTPTN PARTITIONPVMT PAVEMENTPRESTR PRESTRESSEDPBO PROVIDED BY OTHERSPAR PARALLELPREFIN PREFINISHEDPOL POLISHEDPLBG PLUMBINGPKG PARKINGPERIM PERIMETERPERF PERFORATEDPRIM PRIMARYPT POINT OF TANGENCYQTY QUANTITYQT QUARRY TILE(R) REMOVER RISERRD ROOF DRAIN or ROADRL RAIN LEADERRO ROUGH OPENINGROD ROOF OVERFLOW DRAINRWC RAIN WATER CONDUCTORRAD RADIUSRE REFER TO or REFERENCEREINF REINFORCEDREC RECESS(ED)REF REFRIGERATOR or REFRIGERATEDREQD REQUIREDRESIL RESILIENTREV REVISE, REVISED or REVISION(S)RFG ROOFINGRFL REFLECTEDRM ROOMROW RIGHT OF WAYRBS RUBBER BASE STRAIGHTRBC RUBBER BASE COVERB RUBBER BASERH RIGHT HANDRF RESILIENT FLOORINGRECPT RECEPTACLERBT RUBBER TILERVS REVERSE (SIDE)SPRT SUPPORTS SOUTH or SEALEDSC SOLID CORESSK SERVICE SINKSS STAINLESS STEELSR SINK RECEPTACLESCHED SCHEDULESEC SECTIONSHWR SHOWERSHT SHEETSHTG SHEATHINGSIM SIMILARSPECS SPECIFICATION(S)SQ SQUARESF SQUARE FEETSTL STEELSTA STATIONSTD STANDARDSTOR STORAGESTRUCT STRUCTURE or STRUCTURALSUSP SUSPEND(ED)SYM SYMMETRICALSYS SYSTEMSOFF SOFFITSPKR SPEAKERSPKL SPRINKLERT&B TOP AND BOTTOMT TREADT&G TONGUE AND GROOVETB TOWEL BARTO TOP OFTPTN TOILET PARTITIONTV TELEVISIONTELE TELEPHONETHK THICK or THICKNESSTHLD THRESHOLDTYP TYPICALTEMP TEMPORARY or TEMPERATURETG TEMPERED GLASSTBC TOP OF BACK OF CURBTS TUBE STEELTOW TOP OF WALLTOS TOP OF STEELTOC TOP OF CONCRETETHERM THERMOSTATUL UNDERWRITER'S LABORATORYUON UNLESS OTHERWISE NOTEDUOS UNLESS OTHERWISE SPECIFIEDUNFIN UNFINISHEDVVOLTVB VAPOR BARRIERVCT VINYL COMPOSITION TILEVTR VENT THROUGH ROOFVWC VINYL WALL COVERINGVERT VERTICALVEST VESTIBULEVIN VINYL or SHEET VINYLVAR VARY or VARIESVIF VERIFY IN FIELDVER VERIFYVENT VENTILATIONVOL VOLUMEWD WOODW WEST or WIDEW/C WATER CLOSETWPT WORKING POINTW/R WATER RESISTANTWWF WELDED WIRE FABRICW/ WITHW/O WITHOUTWF. WIDE FLANGE or WOOD FLOORINGWDO WINDOWWP WATERPROOF(ING)WSCT WAINSCOTWC WALL COVERINGWT WEIGHTW.O. WHERE OCCURSWGL WIRE GLASSYD YARD&AND<ANGLE@AT# POUND(S) or NUMBERAFF ABOVE FINISHED FLOORASI ARCHITECT'S SUPPLEMENTALINSTRUCTIONSABV ABOVEACOUS ACCOUSTICALADD ADDENDUMADJ ADJACENT or ADJUSTABLEAGG AGGREGATEAHU AIR HANDLING UNITALUM ALUMINUMALT ALTERNATEARCH ARCHITECTURALASPH ASPHALTAUTO AUTOMATICAD AREA DRAIN or ACCESS DOORAPPROX APPROXIMATEA/V AUDIO/VISUALAVG AVERAGEB.O.F. BY OWNER, FUTUREBD BOARDB.O. BY OWNERBLDG BUILDINGBIT BITUMINOUSBLKG BLOCKINGBM BEAM or BENCH MARKBOT BOTTOMBRG BEARNINGBSMT BASEMENTB BASECJ CONTROL JOINTCL COLUMN LINEC.L. CENTERLINECIRC CIRCUMFERENCECAB CABINETCCAULKINGCFL COUNTERFLASHINGCM CENTIMETERSCMU CONCRETE MASONRY UNITCO CHANGE ORDER or CLEANOUTCT CERAMIC TILECEM CEMENTITIOUSCK CORK TILECLG CEILINGCLOS CLOSETCLR CLEARCTR COUNTERCOL COLUMNCONC CONCRETECONSTR CONSTRUCTIONCONT CONTINUOUSCONTR CONTRACTORCORR CORRIDOR or CORRUGATEDCPT CARPETCONN CONNECTIONCATV CABLE TELEVISIONCCTV CLOSED CIRCUIT TELEVISIONCU CUBICCY CUBIC YARDDEG DEGREEDAMP DAMPROOFINGDBL DOUBLEDTL DETAILDIA DIAMETERDIM DIMENSIONDN DOWNDR DOORDS DOWNSPOUTDWG DRAWINGDWR DRAWERDIV DIVISIONDIAG DIAGONALDEMO DEMOLISH or DEMOLITIONEJ EXPANSION JOINT(E) EXISTINGEB EXPANSION BOLTE EASTEA EACHEL ELEVATIONELEC ELECTRICALELEV ELEVATOREMER EMERGENCYENGR ENGINEEREOS EDGE OF SLABEQ EQUALEQUIP EQUIPMENTEXT EXTERIORES EACH SIDEEWH ELECTRIC WATER HEATEREW EACH WAYEST ESTIMATEFAC FIRE ALARM CABINETFA FIRE ALARMFBO FURNISHED BY OTHER(S)FD FLOOR DRAIN or FIRE DAMPERFFL FINISHED FLOOR LINEFR FIRE RESISTIVE or FIRE RATEDFDN FOUNDATIONFIN FINISH(ED)FIXT FIXTUREFLG FLASHINGFLR FLOOR(ING)FLUOR FLUORESCENTFRT FIRE RETARDANT TREATEDFT FOOT (FEET)FTG FOOTINGFURR FURRED or FURRINGFUT FUTUREFF FINISHED FLOORFURN FURNISH(ED)FOM FACE OF MASONRYFOF FACE OF FINISHFOS FACE OF STUDFOC FACE OF CONCRETEGWB GYPSUM WALLBOARDGC GENERAL CONTRACTORGYP. BD. GYPSUM BOARDGA GAUGEGR GRADEGL GLASS or GLAZINGGND GROUNDGALV GALVANIZEDGYP GYPSUMGT GLASS TILEGRT GROUTGI GALVANIZED IRONHM HOLLOW METALHDR HEADERHDWR HARDWAREHT HEIGHTHORIZ HORIZONTALHR HOURHVAC HEATING, VENTILATION and AIRCONDITIONINGHB HOSE BIBHDAS HEADED DEFORMED ANCHOR STUDHAS HEADED ANCHOR STUDHWH HOT WATER HEATERHW HOT WATERHTR HEATERID INSIDE DIAMETERIN INCH(ES)INFO INFORMATIONINSUL INSULATION or INSULATEDINT INTERIORINCAND INCANDESCENTINV INVERTINCL INCLUD(ED)JST JOISTJT JOINTKP KICK PLATEKIT KITCHENKO KNOCKOUTLH LEFT HANDLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLAB LABORATORYLAM LAMINATELBL LABELLT LIGHTLTL LINTELLVR LOUVERLDR LEADERLP LIGHTING PANEL or LIGHT PROOFMO MASONRY OPENINGMAS MASONRYGRAPHIC STANDARDSOWNERSALOON 4937 LLC230 40TH AVE. EASTSEATTLE, WA98112-5030P:VOICEF:FAXLANDSCAPECERES+PO BOX 2134EAGLE, CO 81631P:970-949-3286F:970-262-2162ARCHITECTKH WEBB ARCHITECTS710 WEST LIONSHEADCIRCLE UNIT AVAIL, CO 81657P:970-477-2990F:970-477-2965SURVEYEAGLE VALLEYSURVEYINGPO BOX 1230EDWARDS, CO 81632P:970-949-1406STRUCTURALMARTIN & MARTINPO BOX 8896AVON, CO 81620P:970-926-6007F:970-215-4811CONTRACTORRA NELSONPO BOX 5400CONTACT:AVON, CO 81620P:970-949-5152F:970-949-4379SOILSHP GEOTECH5020 COUNTY RD. 154GLENWOOD SPRINGS,CO 81601P:970-945-7988F:970-945-8454MECHANICALLYLE PROJECTSOLUTIONSPO BOX 1755AVON, CO 81620P:970-376-5350PROJECT TEAMVICINITY MAPLOT 3 / 994PTARMIGAN RDVAIL,COTOWN OF VAIL BLDG PERMIT SUBMITTAL07.10.2015KH WEBB ARCHITECTS, Vail, ColoradoNOT FOR CONSTRUCTIONProject numberDateDrawn by7/11/2015 5:06:59 PMA000COVER SHEETHUGHES-1LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.10.2015Author994 PTARMIGAN RD.07.10.2015No. Description Date01 TOV BLDG. PERMITCODE:INTERNATIONAL RESIDENTIALCODE 2012ZONING:2 FAMILY RESIDENTIALOCCUPANCY CLASSIFICATION:TYPE R DIVISION 3 ( NOT SPRINKLERED)