Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M001.pdf
DRF/SF/S14x1214øDUCTWORK LEGENDDESCRIPTIONROUNDRECTANGULARDUCT RISERDUCT DROP90° ELBOW DN.(NEGATIVE PRESSURE)90° ELBOW DN.(POSITIVE PRESSURE)90° ELBOW UP(NEGATIVE PRESSURE)90° ELBOW UP(POSITIVE PRESSURE)SIZE OR SHAPE TRANSITIONROUND FLEXIBLE DUCTCONNECTION90° RADIUS ELBOW90° MITERED ELBOWW/ TURNING VANES90° STRAIGHT TEE90° CONICAL TEE3DPLANPLAN3D45° BRANCH45° CONICAL BRANCH--COMBINATION FIRE ANDSMOKE DAMPERFIRE DAMPERSMOKE DAMPEROFFSET TO CHANGE ELEVATIOND = DROP R=RISEDUCT SIZE TAG:FIRST NUMBER = PLAN WIDTHMANUAL BALANCING DAMPERMOTORIZED DAMPERBACKDRAFT DAMPER--AAVAIR ADMITTANCE VALVEAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEAUTOAUTOMATICABVABOVEBCSBUILDING CONTROL SYSTEMBDDBACK DRAFT DAMPERBLDGBUILDINGBFGBELOW FINISHED GRADEBOPBOTTOM OF PIPE FROM FINISHED FLOORB/NBETWEENCCOMMONCACOMBUSTION AIRCCCONTROLS CONTRACTORCFMCUBIC FEET PER MINUTE (AIR FLOW RATE)CIPCAST IN PLACECLGCEILING (OR COOLING)CONCCONCRETECONDCONDENSATECONNCONNECT (OR CONNECTION)CONTR'RBUILDINGCOCLEANOUTCOTGCLEANOUT TO GRADECWDOMESTIC WATERDNDOWN(E)EXISTINGEATENTERING AIR TEMPERATUREECELECTRICAL CONTRACTOREXHEXHAUSTEWTENTERING WATER TEMPERATUREEAEXHAUST AIRPLAN ABBREVIATIONS PIPING DESIGNATIONSHYDRONIC PIPINGCS CONDENSATE SUPPLYCRCHSCONDENSER RETURNCHILLED WATER SUPPLYCHS CHILLED WATER SUPPLYCCS CLOSED CONDENSER SUPPLYCCR CLOSED CONDENSER RETURNGLS GEOTHERMAL (OR GROUND) LOOP SUPPLYGLR GEOTHERMAL (OR GROUND) LOOP RETURNHWS HEATING WATER SUPPLYHWR HEATING WATER RETURNHWS(LT) HEATING WATER SUPPLY (LOW TEMP)GF GLYCOL FEEDHWR(LT) HEATING WATER RETURN (LOW TEMP)HWS(HT) HEATING WATER SUPPLY (HIGH TEMP)HWR(HT) HEATING WATER RETURN (HIGH TEMP)HWS(HP) HEATING WATER SUPPLY (HEAT PUMP)HWR(HP) HEATING WATER RETURN (HEAT PUMP)SHWS SOLAR HEATING WATER SUPPLYSHWR SOLAR HEATING WATER RETURNSMS SNOWMELT SUPPLYSMR SNOWMELT RETURNFCS FLOOR COOLING SUPPLYFCR FLOOR COOLING RETURNRFS RADIANT FLOOR SUPPLYRFR RADIANT FLOOR RETURNSTEAM & CONDENSATE PIPINGHPS HIGH PRESURE STEAM SUPPLYHPRLPSHIGH PRESURE CONDENSATE RETURNLOW PRESURE STEAM SUPPLYLPR LOW PRESURE STEAM RETURNMPS MEDIUM PRESURE STEAM SUPPLYMPR MEDIUM PRESURE STEAM RETURNPC PUMPED CONDENSATEPLUMBING PIPINGG NATURAL GASMGFOSMEDIUM PRESSURE GASFUEL OIL SUPPLYFOR FUEL OIL RETURNFOV FUEL OIL VENTFOF FUEL OIL FILLRS REFRIGERANT SUCTIONPG PROPANE GASLPG LIQUID PROPANE GASPD PROPANE DRAIND DRAIN PIPERL REFRIGERANT LIQUIDDOMESTIC COLD WATER (CW)DOMESTIC HOT WATER (HW)HOT WATER RECIRCULATION (HWC)NON-SOFTENED DOMESTIC WATERNSFIRE LINEFCOMPRESSED AIRCAPW PUMPED WASTEWWASTEVENTVACID WASTEAWACID VENTAVGREASE WASTEGWGREASE VENTGVSTORM DRAINSTSTORM DRAIN OVERFLOWST(OF)SECONDARY DRAINSDSAND AND OIL WASTESON2O NITROUS OXIDEN2 NITROGENINSTRUMENT AIRIAMEDICAL AIRMAOXGENO2VACUUMVACCARBON DIOXIDECO2WASTE ANESTHETIC GAS DISPOSALWAGDBDDBDDFIXTURE CONNECTION SCHEDULEWCWATER CLOSET (FLUSH VALVE)ABBREV.-HW1"CW4"WASTE2"VENTNOTES:1.2.3.4.5.6.7.8.9.WATER CLOSET (FLUSH TANK)URINAL (BLOWOUT)URINAL (WASHDOWN)URINAL (WATERLESS)LAVATORYHAND SINKSERVICE SINKMOP SERVICE BASINDRINKING FOUNTAIN / E.W.C.KITCHEN SINK W/ OR W/O DISPOSERBATHTUB / SHOWERCLOTHES WASHER ROUGH-INDISH MACHINE ROUGH-INDISHWASHER ROUGH-INBAR SINKFLOOR SINKFLOOR DRAINTROUGH DRAINWORK SINKHOSE BIBWCT - 1/2" 4" 2"UR 1" 2" 1-1/2"UR 3/4" 2" 1-1/2"UR - 2" 1-1/2"LAV 1/2" 1-1/2" 1-1/2"HS 1-1/2" 1-1/2"SS 3" 2"MSB 3/4" 3" 2"DF - 1/2"KS 1/2" 1/2" 2"SH 3/4" 3/4" 2"CW 1/2" 1/2" 2"DMDWBSFSFDTDWSHB---1/2"1/2"1/2"3/4"1/2"1/2"1-1/2" 1-1/2"1-1/2"1-1/2"1-1/2"-1/2"1/2" 1/2"3/4" 3/4" 2" 1-1/2"2" 1-1/2"1-1/2"1-1/2"---------3/4"3/4"3/4"3"3"2"2"2"2"1-1/2"1-1/2"SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZESMAY BE INDICATED ON PLANS WHERE REQUIRED.MINIMUM DOMESTIC PIPE SIZE TO 2 OR MORE FIXTURES IS 3/4".RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTESIZES.WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY.WHERE ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZESMAY VARY WHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK VENTS,WET VENTS, OR COMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIORAPPROVAL FROM THE ENGINEER IS REQUIRED TO USE THESE ALTERNATIVEVENTING METHODS.PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOTLOCATED IN FOOD SERVICE AREAS.MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2".ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT.REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBINGFIXTURE CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND GARBAGEDISPOSALS.PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALLREFRIGERATOR LOCATIONS.-PLAN SYMBOLSCONTROL PANEL/RADIANT MANIFOLDT---P---SHCOPEPOCO2SPCARBON DIOXIDE SENSORCARBON MONOXIDE SENSORFIRE RISERDIAGRAM CONTINUATION REFERENCEPLUMBING RISERHEATING WATER RISERTHERMOSTATHVAC RISERPOINT OF NEW CONNECTIONDUCT STATIC PRESSURE SENSORROOM PRESSURE SENSORHUMIDISTATREMOTE TEMPERATURE SENSOREMERGENCY POWER OFF SWITCHACCESS PANELSNOWMELT MANIFOLDSECTION CUT LETTER/SHEET SHOWN ONPOINT OF DISCONNECTIONA15012x6XFR12x6TYPE OF AIR DEVICERE: GRD SCHEDULE.AIR DEVICEDESIGNATION KEY# = AIR QUANTITY(CFM)CA = COMB. AIROSA = OUTSIDE AIRRET = RETURNEXH = EXHAUSTXFR = TRANSFERSIZE (INCHES) OR MINIMUMFREE AREA REQUIRED INSQUARE FEETINDICATES AIR INLET DEVICEDUCT/PIPE RISERDESIGNATION KEYPIPING:CH - CHILLED WATERDW - DOMESTIC WATERHW - HEATING WATERG - GAS PIPINGWV - WASTE AND/OR VENTPR - PIPING RISER (MISC TYPES)ST - STORM DRAINS2 - SECONDARY STORM DRAINRISER NUMBERPR203REFERENCE SAMPLERE: B/M400 FFINOTES1.2.FFI = FOR FURTHER INFORMATIONFCT = FOR CONTINUATIONSHEET NUMBERDRAWING NUMBER ORDIAGRAM LETTERREFER TO:ALL SYMBOLS, ABBREVIATIONS, ANDDESIGNATIONS ON LEGEND SHEET ARENOT NECESSARILY USED ON THISPROJECT.THIS DRAWING SET CONSISTS OF DATAGENERATED, IN PART, BY OTHER PARTIES.NOT ALL SYMBOLOGIES AND NOTATIONCONVENTIONS OCCURRING IN THISDRAWING SET ARE NECESSARILY DEFINEDON THESE LEGENDS. CONSULT THEENGINEER IN THE EVENT SYMBOLOGY ORNOTATION INTERPRETATION IS REQUIRED.NOTE:FOR STANDARD MODULE SIZEREGISTERS, SIZE GIVEN IS NECK SIZE.REFER TO GRD SCHEDULE FORMODULE SIZE.BAIR SIDE:EA - EXHAUST AIROA - OUTSIDE AIRRA - RETURN AIRSA - SUPPLY AIRFBOFURNISHED BY OWNERFCOFLOOR CLEANOUTFCTFOR CONTINUATIONFFIFOR FURTHER INFORMATIONGCGENERAL CONTRACTORGHXGROUND HEAT EXCHANGERGPMGALLONS PER MINUTE (WATER FLOW RATE)HPHORSE POWERHWDOMESTIC HOT WATERLATLEAVING AIR TEMPERATURELFLINEAR FOOTLWTLEAVING WATER TEMPERATUREMCMECHANICAL CONTRACTORMFGMANUFACTURERMODMOTOR OPERATED DAMPER(N)NEWNCNORMALLY CLOSEDNECNATIONAL ELECTRIC CODENICNOT IN CONTRACTNONORMALLY OPENKWKILOWATTSOAOUTSIDE AIROBDOPPOSED BLADE VOLUME DAMPEROCON CENTEROSAOUTSIDE AIRRARETURN AIRREQ'DREQUIREDREQ'MTSREQUIREMENTSSASUPPLY AIRSFSQUARE FOOT (FEET)SPSTATIC PRESSURESSSTAINLESS STEELTATHROW-AWAY (OR TRANSFER AIR)TYPTYPICALUNOUNLESS OTHERWISE NOTEDVTRVENT THROUGH ROOFW/WITHW/OWITHOUTRE:REFER TO:WCOWALL CLEANOUTXFRTRANSFERUNOUNLESS OTHERWISE NOTEDVTRVENT THROUGH ROOFW/WITHNONORMALLY OPENFSDCOMBINATION FIRE/SMOKE DAMPERFACPFIRE ALARM CONTROL PANELFAFREE AREANOT FOR CONSTRUCTIONProject numberDateDrawn by7/5/2015 6:40:23 PMM001MECHANICAL LEGENDSHUGHES-1LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence06.29.15DALNo. Description DateGENERAL NOTES:1. XXXMECHANICAL SHEET INDEX#TITLEISSUE LOGPERMIT - 06.26.15M003 MECHANICAL SCHEDULESM001 MECHANICAL LEGENDSM002 MECHANICAL SCHEDULESM100 MECHANICAL SITE PLANM101 LEVEL 1 PIPING PLANM102 LEVEL 2 PIPING PLANM103 LEVEL 3 PIPING PLANM201 LEVEL 1 HVAC PLANM202 LEVEL 2 HVAC PLANM203 LEVEL 3 HVAC PLANM301 LEVEL 1 PLUMBING PLANM302 LEVEL 2 PLUMBING PLANM303 LEVEL 3 PLUMBING PLANM400 ENLARGED MECHANICAL PLANSM500 MECHANICAL DIAGRAMSM501 MECHANICAL DIAGRAMSM502 MECHANICAL DIAGRAMSISSUE LOG KEY:'√ ' ISSUED AS PART OF SET' ' NOT PART OF SET' * ' ISSUED FOR INFORMATION ONLY