HomeMy WebLinkAboutM302.pdfDNDNDNH BH BP3P3G TO BBQ.562734ABCGHKLMEDJFP5P53/4"G TO FIREPLACE.P4P8P8P9P8P5P41"CW, 1"HW, &1/2"HWC DN.VVCWHWHWCVVVP6V_"CW, _"HW,& _"HWCRISERS.V_"CW, _"HW,& _"HWCRISERS.3/4"G TO FIRE PLACE.NOT FOR CONSTRUCTIONProject numberDateDrawn by7/5/2015 6:41:19 PMM302LEVEL 2 PLUMBING PLANHUGHES-1LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence06.29.15DAL 1/4" = 1'-0"1LEVEL 2 PLUMBING PLANNo. Description DateRE: _/M_ FOR CLEANOUT DIAGRAMS.RE: _/M_ FOR ISLAND VENT DIAGRAM.RE: _/M_ FOR TRAP PRIMER CONNECTION.REFER TO THE PLUMBING FIXTURECONNECTION SCHEDULE FOR PIPE SIZES TOINDIVIDUAL FIXTURES.NOT ALL REQUIRED CLEANOUTS ARENECESSARILY SHOWN ON THESE PLANS.PROVIDE CLEANOUTS ON WASTE, VENT ANDSTORM PIPING AS REQUIRED BY CODE ANDFOR REASONABLE MAINTENANCE BASED ONACTUAL FIELD INSTALLATION. COORDINATELOCATIONS WITH ARCHITECT/ENGINEER.COORDINATE ROUTING OF CONDENSATEDRAIN LINES WITH ARCHITECT PRIOR TOINSTALLATION.PIPING ON EXTERIOR WALLS OR PRE-CASTCONCRETE WALLS TO BE ROUTED IN FRAMEDWALL ON INTERIOR SIDE OF INSULATION.ST AND ST(OF) PIPING 3", UNOINSTALL THERMOSTATIC MIXING VALVES,ASSE 1070 LISTED, AT EACH PUBLICHANDWASHING LAVATORY/SINK. SIZE TOMATCH HW PIPE SIZE.ROOF OVERFLOW DRAINAGE STRATEGY TOBE DETERMINED OR VIA ARCHITECTURALSCUPPERS UNOTERMINATE PLUMBING VENTS NOT LESSTHAN 12" ABOVE ROOF.AVOID ROUTING PIPING OVER ELECTRICALROOMS OR ELECTRICAL PANELS; MAINTAINN.E.C. CLEARANCES. COORDINATEROUTINGS WITH ELECTRICAL CONTRACTOR.CONTRACTOR TO MAINTAIN 8'-6" CLEAR HEADHEIGHT IN GARAGE AND INFORM THEENGINEER AND ARCHITECT OF ANY AREASTHAT MAY NOT MEET 8'-6" PRIOR TOINSTALLATION, MINIMUM 8'-2" CLEAR HEADHEIGHT MUST BE MAINTAINED INACCESSIBLE VEHICLE AREAS.PROVIDE FLEXIBLE PIPE CONNECTIONS TOALL MOTORIZED EQUIPMENT.ROUTE DOMESTIC HOT WATER RECIRC TOWITHIN 10 FEET OF ALL HOT WATER FIXTURES.CONNECT WITHIN 5 FEET OF 0.5 GPM ANDLOWER FAUCETS.VERIFY ALL EQUIPMENT ACCESS PANELSWITH MANUFACTURER AND ARCHITECT.PROTECT PIPING ROUTED ALONG COLUMNS,WALLS, ETC. FROM DAMAGE AS NECESSARYWITH CAGES. COORDINATE WITH ARCHITECT.PEX PIPING SHALL NOT BE ALLOWED TOPENETRATE FIRE BARRIERS WHERE FIRECAULKING IS REQUIRED.ALL VALVES SHALL BE INSTALLED ABOVEDROP-IN CEILINGS IN ACCESSIBLELOCATIONS, OR WITH ACCESS PANELS INHARD-LID CEILINGS.ALL PIPING SHALL BE ROUTED AS HIGH ASPOSSIBLE IN THE CEILING SPACE. UTILIZEJOIST SPACE WHEN POSSIBLE, ESPECIALLYWHERE CROSSING OTHER PIPES, DUCTS,AND ELECTRICAL.ACCESS PANELS SHALL BE 24x24, UNOLOCATIONS SHOWN ARE APPROXIMATE,EXACT LOCATIONS SHALL BE COORDINATEDWITH THE ARCHITECTS DRAWINGS AND WITHTHE LOCATIONS OF THE EQUIPMENT ORAPPARATUS THAT THEY SERVE.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.17.18.19.20.PLUMBING NOTES: