HomeMy WebLinkAboutM500.pdfGRADEMETERUNIONPRV BY UTILITY.SHUT-OFF VALVE.BUILDING GASPIPING TOMETER SET BYUTILITY.TO BUILDING. SEE PLANSFOR CONTINUATION._"DESIGNER NOTE:VERIFY ENTRANCEDIAGRAM WITHCONNECTING UTILITYCOMPANY.MGAS ENTRANCE DIAGRAMNO SCALEISLAND VENT DIAGRAMNO SCALEWVFLOORVDRAINBOARD2"SLOPE2"C.O.SLOPE1. EXTEND VENT AS HIGH AS POSSIBLE BUT NOTLESS THAN THE DRAINBOARD HEIGHT & THENRETURNING IT DOWNWARD & CONNECTING IT TOTHE HORIZONTAL SINK DRAIN IMMEDIATELYDOWNSTREAM FROM THE VERTICAL FIXTUREDRAIN.2. THE RETURNED VENT SHALL BE CONNECTED TOTHE HORIZONTAL DRAIN THRU A Y-BRANCHFITTING & SHALL, IN ADDITION, BE PROVIDEDWITH A FOOT VENT TAKEN OFF THE VERTICALFIXTURE VENT BY MEANS OF A Y-BRANCHIMMEDIATELY BELOW THE FLOOR & EXTENDINGTO THE NEAREST PARTITION & THEN THRU THEROOF OR CONNECTED TO OTHER VENTS, IN ANAPPROVED MANNER.3. DRAINAGE FITTINGS SHALL BE USED ON ALLPARTS OF THE VENT BELOW THE FLOOR & A MIN.SLOPE OF 1/4"/FT BACK TO THE DRAIN SHALL BEMAINTAINED.4. THE RETURN DRAIN UNDER THE DRAINBOARDSHALL BE A ONE PIECE FITTING OR ANASSEMBLY OF A 45°, A 90°, & A 45° IN THE ORDERNAMED.5. THE ISLAND SINK DRAIN, UPSTREAM OF THERETURNED VENT, SHALL SERVE NO OTHERFIXTURES.VENT LINENEARESTPARTITION.WALL CLEANOUT11/2"11/2"SINK DRAIN TO BUILDINGSEWER.REQUIREMENTSSUPPLY DIFFUSER REMOTE BALANCE DAMPER DIAGRAMNO SCALENOTE:CEILING DIFFUSERSHOWN. FLOORDIFFUSER SIMILAR.INSULATED SUPPLYAIR PLENUM.24" STANDARD CABLEOR AS REQUIRED.ROUNDDAMPER.TAKE-OFF ASREQUIRED.PLENUMADJUSTABLEMOUNTING CLAMP.DIFFUSER.ADJUSTS WITH 1/4"NUTDIRVER, SPECIFYOPTIONAL SCREWDRIVERTIP IF LESS THAN 3/8"NON-ACCESSIBLE BRANCH DUCT DAMPERBATHROOM WALL EXHAUST DIAGRAMNO SCALEBATHROOM EXHAUSTDUCTS. RE: PLANS FOR SIZEAND QUANTITY.BACKDRAFT DAMPER,MOTORIZED DAMPER REQ'D FOR300 CFM OR GREATER.6" DEEPINSULATEDPLENUM BOX.SEAL AIRTIGHT.REMOVABLELOUVER.FACE OF EXTERIORWALL.AS NOTED ONPLANS.INSULATE EXH DUCTS24" INBOARD OFENVELOPE.MIN. HEIGHT = MAXEXH DUCTDIAMETER + 2" BOTHSIDES.STUD SPACE RETURN AIR TRANSFER DUCT DIAGRAMRETURN GRILLE, TYP.SHEET METAL. CAULK ANDPAN STUD CAVITY WITHSTRUCTURE (NOT SHOWN).STUDS CONTINUE TOSEAL FOR AIRTIGHTCONNECTION, TYP.WALL FINISH BY ARCH.FLOOR STRUCTURE.RE: ARCH.INTERNALLY LINE STUDCAVITY WITH 1/2"ACOUSTICAL DUCT LINER.NO SCALEAIR CONTROL & EXPANSIONTANK DIAGRAMNO SCALEHWSAIR PURGER W/AIR VENT.HOSE END VALVEFOR SYSTEM FILL.DIAPHRAGM TYPEEXPANSION TANK.FROMBOILER, ETC.TO PUMP.NO SCALEROUND DUCTTAKE-OFF DIAGRAMAIR FLOWUSE DUCT SEALANT ORGASKETED FITTING ON HIGHVELOCITY DUCT.CONICAL SPIN-IN FITTING W/MANUAL DAMPER, HANDLE,& LOCK NUT.FLEX DUCT.WORM DRIVE S.S. CLAMP.NOTE:DIAGRAM FOR LOW & HIGH VELOCITYDUCTWORK EXCEPT UPSTREAM OFVAV BOXES. OMIT DAMPER & FLEXDUCT UPSTREAM OF VAV BOXES.TYPICAL HANGER DIAGRAMNO SCALEANCHOR,REFER TOSTRUCTURAL.THREADEDROD.HANGER.PIPE.CONCRETESTRUCTURE.NOTE:ALL PIPING WITHINSULATION TO HAVEINSULATION RUN FULLSIZE THROUGHHANGER WITH SHIELDAND INSERT.DUCT MOUNTED REGISTERNO SCALEAIRFLOW DIRECTIONSUPPLYMIN 6"RETURNAIRFLOW DIRECTIONTURNED IN FLANGE.O.B.D.GRILLE.45° ENTRY BOOTSEAL ATCONNECTION TODUCT.HRV DUCT CONNECTIONS AND CLEARNACES DIAGRAMNO SCALETOP VIEWFRONT VIEWLEFT VIEW RIGHT VIEWE-BOXEAFAEAFAOARAOARAFIELD PROVIDED SUPPORTFRAME, UNIT-STRUT OREQUIV.PRIVDE SPRING VIB.ISOLATORS.ROUND HANGERROD, TYP.FLEXIBLE CANVASCONNECTOR, TYP. 4.PROVIDE FULL UNIT'SWIDTH OF CLEARANCEAT SIDE OF UNIT.SNOWMELT CONNECTION: STAIR TO WALK DIAGRAMNO SCALE9" O.C. TYP. FOR ALLLANDINGS & WALKS.HYDRONIC SNOWMELTTUBING.NOTE:REFER TO ARCH. DWG #___FOR STAIR DIMENSIONS.6" O.C. TYP. FOR ALLSTAIRS.CEILINGFIRE ENTRY PIPING DIAGRAMFNO SCALEDFSDDFCLEANOUT DIAGRAMSNO SCALE6"ABCDEFGIJKHMNLFAN COIL UNIT INSTALLATIONNO SCALEDDFIRE DEPT. CONNECTION.EXTERIOR BLDG. WALL.TO FIRE PROTECTION SYSTEMS.TEST VALVE; PIPE TO OUTSIDE.FLOW SWITCH TO ALARMS, SEE SPECS.DRAIN VALVE; PIPE INDIRECT TO FLOOR DRAINPER NFPA 25 REQUIREMENTS, TYP.SHUT-OFF VALVE.DOUBLE CHECK TYPE BACKFLOW PREVENTER.TAMPER SWITCHES ON VALVES.FIRE SERVICEFLANGE.FLOOR SINKBALL DRIPVALVE.C.W. SERVICEDIAGRAM SHOWN FOR REFERENCE ONLY, CONFIRM FINAL REQUIREMENTSWITH FIRE PROTECTION DESIGN BUILD CONTRACTOR AND ENGINEER OFRECORD.PRV SET @150 PSISLOPE DN @ 1/4"/L.F.WASTE LINEFINISHED GRADEADJUSTABLE GRADE CLEANOUT AND ACCESS ENCLOSURE WITH ANCHORFLANGE, HEAVY DUTY TOP, AND VANDAL PROOF FASTENERS, ZURN,Z-1400-HD-KBRASS CLEANOUT PLUG W/COUNTER SUNK HEAD.ADJUSTABLE CLEANOUTAND ACCESS COVER ZURNZB-1400. TOP OF COVER TOBE FLUSH W/ TOP OF FLOOR.16" CONC. PAD TROWELSMOOTH & EDGE.1/8 C.I. BENDBALANCE OF PIPING SAMEAS CLEANOUT TO GRADE.FLOOR LINE1/8 C.I. BENDC.I. WASTE LINE.LGTH TO SUIT.1/8 BEND IF CLEANOUTOCCURS AT END OF LINE.PROVIDE FOLLOWING OPTIONS ASAPPROPRIATE CARPET MARKER - FORCARPETED AREAS. SQUARE TOP - FORCERAMIC TILE OR SIMILAR SQUAREPATTERN FLOOR.FLASHING CLAMP - FOR ABOVE GRADEWATER PROOFED AREAS.SAFAN COIL UNITRAFILTER W/ ACCESSPANEL.CONDENSATE DRAIN. PIPEINDIRECT TO APPROVEDRECEPTOR (PROVIDEMIN. 2" DEEP TRAP).SHEET METAL DRAINPAN.3/4" SECONDARY DRAIN TOAPPROVED RECEPTOR.PIPE INDIRECT TO FLOORDRAIN ON SINK TAIL PIECE,TYP.ROUND HANGER ROD TYP.WITH EXCEPTION OF FANCOILS LOCATED IN ATTIC.SPRING VIBRATIONISOLATORS, TYP.DOUBLE LOCKNUT.NOTES:1. RETURN AIR PLENUM FULLSIZE OF UNIT CONNECTION.2. THIS SUPPORT SYSTEM IS NOTALLOWED IN THE ATTIC.3. LOCATE ATTIC FAN COILS ON4" HOUSEKEEPING PAD WITHSPRING VIBRATIONISOLATORS.MOTORIZED DAMPER.MIXING BOX.OSAFLOOR CLEANOUT (FCO)CLEANOUT TO GRADE (COTG)NOT FOR CONSTRUCTIONProject numberDateDrawn by7/5/2015 6:41:32 PMM500MECHANICAL DIAGRAMSHUGHES-1LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence06.29.15DALNo. Description Date