HomeMy WebLinkAboutM501.pdfRADIANT MANIFOLD PIPING DIAGRAMNO SCALEABHWRHWSNOTE:PROVIDEMANUFACTURER'SMANIFOLDS WITH VALVESEAGLE RIVER WATER ENTRANCE DIAGRAMFMNO SCALE2-WAY COIL PIPING DIAGRAMNO SCALECE3-WAY COIL PIPING DIAGRAMNO SCALEDMANIFOLD BOX WITH ACCESS DOORMOUNTED IN WALL. FIRE RATEDACCESS DOOR AS REQUIRED.MANUFACTURER'S MANIFOLD ASSY.WITH VALUES.ZONE BALANCE VALVEUNISTRUT SUPPORTSERPENTINE TUBING. QUANTITY ASREQUIRED.TAPE PIPE AT UNISTRUT SUPPORT.MANUFACTURER'S MANIFOLD ASSY.WITH VALUES.TO T-STAT.TO PIPING MAINSLOOP CONTROL VALVES, TYP.SEE FIRE ENTRY DIAGRAM ,THIS SHEET. _" LINE (VERIFYWITH FIRE PROTECTIONCONTRACTOR).DOMESTIC WATER SERVICESHUT-OFF VALVE._" IRRIGATION LINE WITHAPPROVED REDUCED PRESSUREBACKFLOW PREVENTION DEVICE.(VFY. WITH IRRIGATIONCONTRACTOR).1-1/2" CW TO BUILDING.REDUCED PRESSURE TYPEBACKFLOW PREVENTER.CERTIFIED TESTER TO TEST.1" WATER METER WITHREMOTE READOUT.PRESSURE REDUCING VALVE, TYP.WATTS 223, __" SET @ 60 PSIWATTS 223, __" SET @ __ PSI2" CW/FIRE SERVICE (VERIFYSIZE WITH FIRE PROTECTIONCONTRACTOR).NOTE:WATER METER AND BACKFLOWPREVENTER MUST BE MOUNTEDHORIZONTALLY.DESIGNER NOTES:1. VERIFY IF & WHERE BFP IS REQ'D.2. VERIFY IF FIRE PIPING APPLIES TO JOB. 3.LOCATE REMOTE METER READOUT.4. IF ONLY ONE PRV IS USED, OMIT a. SECOND PRV b. ISOLATION VALVES ON PRV5. COORDINATE PIPING AND VALVING WITH AHJ.METERBYPASS.COILNOTES:1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENTCONTAINING FANS OR COMPRESSORS, NOT REQ'D FOREQUIPMENT SUCH AS DUCT COILS.2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATERENTERS MOST DOWNSTREAM COIL, LEAVES MOSTUPSTREAM COIL).3. REFER TO CONTROLS DRAWINGS FOR ADDITIONALINFORMATION.4. 2-WAY VALVE NORMALLY OPEN FOR HEATING ANDNORMALLY CLOSED FOR COOLING.MANIFOLD PIPING DIAGRAMNO SCALESMRSMSCONTROL VALVE.MANIFOLD BOX (WALLMOUNTED FORRADIANT; LOCATED INSLAB FORSNOWMELT).MANUFACTURER'SMANIFOLD ASSY.LOOPBALANCE/ISOLATIONVALVEMANUFACTURER'SMANIFOLD ASSEMBLYWITH REVERSERETURN PIPING.RADIANT/SNOWMELTTUBING. LOOPQUANTIITY ASREQUIRED.NOTES:1. PROVIDE MANUFACTURER'S MANIFOLDS AND ISOLATION VALVES WITH PIPING.2. FOR EXTERIOR MANIFOLD LOCATIONS PROVIDE WATERPROOF MANIFOLD BOX ORWATERPROOF CONTROL VALVE.TO PIPING MAINSAIR VENT AT HIGHPOINTS, TYPICAL.MANIFOLD BALANCEVALVE.RETURNSUPPLYCOILNOTES:1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENTCONTAINING FANS OR COMPRESSORS, NOT REQ'D FOREQUIPMENT SUCH AS DUCT COILS.2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATERENTERS MOST DOWNSTREAM COIL, LEAVES MOSTUPSTREAM COIL).3. REFER TO CONTROLS DRAWINGS FOR ADDITIONALINFORMATION.4. 3-WAY VALVE WITH COIL RETURN PIPED TO NORMALLYOPEN PORT FOR HEATING AND NORMALLY CLOSED PORTFOR COOLING.MANUAL AIR VENTAT HIGHESTPOINT IN PIPING.STRAINERWITHBLOWDOWNVALVE ANDCAP.SUPPLYRETURNSTRAINERWITHBLOWDOWNAND CAP.MANUAL AIR VENTAT HIGHESTPOINT IN PIPING.NOT FOR CONSTRUCTIONProject numberDateDrawn by7/5/2015 6:41:32 PMM501MECHANICAL DIAGRAMSHUGHES-1LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence06.29.15DALNo. Description Date