HomeMy WebLinkAboutS310.pdf1
1
WALL
DWLS
LTS
T/FTG
SEE PLAN
MATCH SIZE AND NUMBER
OF FTG LONG BARS 2'-0" MAXT(1'-0" MIN)
T
BOT REINF
PER SCHED
TOP REINF IF
NOTED IN
SCHED
PLAN WL
L BARS
W BARS
APPROVED
BRG MATL, SEE
EARTHWORK
SPEC (L x W)
PLAN DIMENSIONS TT/FTG, SEE PLAN
L BARS
W BARS 2" CLR3" CLRMARK FOOTING SIZE
L x W x T
REINFORCING SERVICE
CAPACITY
(KIPS)
REMARKS
F2 2'-0"x2'-0"x1'-0" (3) #4 EW BOT
40
F3 3'-0"x3'-0"x1'-0" (4) #4 EW BOT
62
F4 4'-0"x4'-0"x1'-0" (4) #5 EW BOT
90
F5 5'-0"x5'-0"x1'-0" (5) #5 EW BOT
122
F6 6'-0"x6'-0"x1'-2" (7) #5 EW BOT
160
F7 7'-0"x7'-0"x1'-6" (7) #6 EW BOT
F8 8'-0"x8'-0"x1'-10" (9) #6 EW BOT
22
10
SPREAD FOOTING SCHEDULE
SOIL ALLOWABLE PRESSURE = 2500 PSF
-
-
-
-
-
-
-
INSIDE FACESINSIDE FACES
INSIDE FACES
CROSS WALL
BAR SIZE & SPACING
TO MATCH HORIZ
REINF
OUTSIDE FACE (SOIL
SIDE)
OUTSIDE FACE
(SOIL SIDE)
HORIZ REINF
SOLID CIRCLE INDICATES ADDITIONAL
VERTICAL BARS, SIZE TO MATCH
WALL VERT REINF
OPEN CIRCLE INDICATES
VERTICAL REINF
LTS OR CONT, TYP
T/FTG = SEE PLAN
TOC = SEE PLAN
4'-0" MIN(4) #5 VERT
#3 TIES AT 10" OC
(2) AT 3" OC TOP
S310
2
SIMPSON CB66 HDG
COLUMN BASE, CTR
IN PILASTER
VERT WALL
REINF
HORIZ WALL
REINF
INTERMITTENT 1'-0"
LONG KEYS @ 2'-0" OC.
EDGES MAY BE ANGLED
AT CONTR'S OPTION
LTS
1ST POUR 2ND POUR
1 1/2"EQEQEQ1'-0"1'-0"1'-6"
S320
36"
(2) #4xCONT
(2) #4@12" OC (2 MIN)
#4@18" OC
ALT HOOK DIR VARIES. SEE PLANS320
3
T/FTG = SEE PLAN
#4@12" OC EW
3" CLRSTD HOOK
SEE PLAN
#4@12" OC, EW LTS MINCOORDINATE HORIZ CONST JT LOCS
WITH ARCH. LIMIT POUR HEIGHT AS
REQD TO ACHIEVE CONSOLIDATION
AND SPECIFIED FINISH
ARCHITECTURALLY
EXPOSED CONCRETE
FINISH. SEE ARCH FOR
FINISH, COLOR AND MOCK
UP REQUIREMENTS
6
S310
FOR "OUTSIDE
FACE"
CORNER
REINF1'-0"1'-0"4'-0"
S320
3
6"
(5) #4xCONT
(2) #4@12" OC (2 MIN)
#4@18" OC
ALT HOOK DIR
#4@12" OC
TRANSVERSE
Project number
Date
Drawn by
MM JOB #: 15.0197.S.01PRINCIPAL/EOR: PDPROJECT MANAGER: KHDESIGNERS: JW/KHDATE PRINTED:FILE PATH:07/02/2015
C:\Proj\15.0197-994Ptarmigan-RS15_kevinh.rvt7/2/2015 2:34:40 PMS310
TYP FOUNDATION DETAILS
M15.0197.S.01LOT 3 / 994 PTARMIGAN RDVAIL,COHughes Residence07.02.2015
KH
NO SCALE4 TYP SINGLE STEP AT WALL FOOTING
NO SCALE2 TYP SPREAD FOOTING
NO SCALE6 TYP FND WALL W/TWO LAYERS REINF
1" = 1'-0"5 TYP EXT COL AT FTG
NO SCALE7 TYP WALL VERTICAL CONST JOINT
1" = 1'-0"8 INT WALL FOOTING
NO SCALE9 CHIMNEY FOUNDATION SECTION
1" = 1'-0"10 INT WALL FOOTING - 2
No. Description Date
PERMIT SET 07.02.2015