HomeMy WebLinkAboutF14-0015 Equipment.pdfCORPORATION
57 HEREFORD LANE
EDWARDS, CO 81632
PH: (970) 914-5014
VORLAUFER UNIT 103 KEMP RESIDENCE
385 GORE CREEK DRIVE
VAIL, CO 81657
EQUIPMENT SUBMITTAL
5/1/2014
Worldwide
Contacts www.tyco-fire.com
General
Description
The TYCO RAPID RESPONSE Series LFII Residential Horizontal Sidewall Sprinklers (TY2334) are decorative, fast response, frangible bulb sprin-klers designed for use in residential occupancies such as homes, apart-ments, dormitories, and hotels. When aesthetics and optimized flow charac-teristics are the major consideration, the Series LFII Residential Sprinklers (TY2334) should be the first choice.
The Series LFII Residential Sprinklers are intended for use in the following scenarios:
• wet pipe residential sprinkler systems for one-and two-family dwellings and mobile homes per NFPA 13D
• wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R
• wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13
The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut.
The Series LFII Residential Sprinklers has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen-tial fires and to improve the chance for occupants to escape or be evacuated.
NOTICE
The Series LFII Residential Horizontal Sidewall Sprinklers (TY2334) described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any author-ities having jurisdiction. Failure to do so may impair the performance of these devices.
The owner is responsible for main-taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions.
Sprinkler Identification
Number (SIN)
TY2334
Technical
Data
ApprovalsUL and C-UL Listed NSF Certified to NSF/ANSI 61
For details on approvals, refer to the Design Criteria section.
Maximum Working PressureMaximum 175 psi (12,1 bar)
Discharge CoefficientK= 4.4 GPM/psi1/2 (63,4 LPM/bar1/2)
Temperature Rating155°F (68°C) or 175°F (79°C)
FinishesNatural BrassSignal White Chrome Plated
Physical CharacteristicsFrame....................BrassButton...................BronzeSealing Assembly. . . . . . . . .Beryllium Nickel w/ TEFLONBulb .................3 mm GlassCompression Screw. . . . . . . . BronzeDeflector.................Copper
RAPID RESPONSE Series LFII Residential Sprinklers
4.4 K-factor Horizontal Sidewall
Wet Pipe Systems
Page 1 of 6 APRIL 2013 TFP412
IMPORTANT
Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely.
Worldwide
Contacts www.tyco-fire.com
Sealing-3
54
*
6
Compression
of Deector.
is indicated on top
Temperature rating
Bulb
Deector-
--
*
1
Components:
2 Button
Frame-
-WRENCH
STYLE 20RECESSED
ESCUTCHEON
FLATS
2-7/8" DIA.
RECESSED
(73,0 mm)5 NOMINAL
PLATE SEATINGSURFACE
ESCUTCHEON
MAKE-IN
CENTERLINE
OF WATERWAY
7/16" (11,1 mm)
(54,0 mm)
(38,1 mm)
DEFLECTORBOSS
(11,1 mm)7/16"
END-OF-
2-1/8"
1-1/2"
DEFLECTOR
TOP-OF-
4 26*
1 3
Assembly
Screw TOP1/2" NPT
FLATSWRENCH
FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY2334)
1-1/4" (31,8 mm)
1" (25,4 mm)
MOUNTING
PLATE
TY2334
MOUNTINGSURFACE
CLOSURE
(73,0 mm)
1/2" (12,7 mm)
(57,2 mm)2-1/4" DIA.
1/4" (6,4 mm)
1/8"(3,2 mm)
(11,1±3,2 mm)
SPRINKLER
FITTING
FACE OF
7/16±1/8"
2-7/8" DIA.
BOSS
END-OF-DEFLECTOR
TOP-OF-DEFLECTOR
7/16"(11,1 mm)
FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY2334)
WRENCH RECESS(END "A" USED
FOR TY2334)
FIGURE 3 W-TYPE 6 SPRINKLER WRENCH
RECESS
WRENCH
WITH SPRINKLER
ENGAGEMENT
IN TO ENSURE
WRENCHING AREA
PUSH WRENCH
FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH
TFP412Page 2 of 6
Operation
The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to activate and flow water.
Design
Criteria
The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers are UL and C-UL Listed for installation in accordance with this section.
Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer’s recommendations that may be accept-able to the local authority having jurisdiction.
System TypeOnly wet pipe systems may be utilized.
Ceiling TypeSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable.
Hydraulic Design
(NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rate are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R.
Hydraulic Design(NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following:
• The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area.
• A minimum discharge of 0.1 gpm/ft2 over the “design area” comprised of the four most hydrau-lically demanding sprinklers for the actual coverage areas being protected by the four sprinklers.
Obstruction to Water DistributionSprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490.
Operational SensitivityThe sprinklers are to be installed with an end of defector-boss to wall distance of 1-1/8 to 6 inches.
In addition the top-of-deflector-to-ceiling distance is to be within the range (Ref. Table A) being hydraulically calculated.
Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calcu-lated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area).
Installation
The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers must be installed in accordance with this section.
General InstructionsDo not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm).
A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler.
Do not attempt to compensate for insufficient adjustment in the sprinkler by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit.
Series LFII Residential Horizontal Sidewall SprinklersThe Series LFII Horizontal Sidewall Sprinklers must be installed in accor-dance with the following instructions.
Step 1. Horizontal sidewall sprin-klers are to be installed in the hori-zontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling with the front edge of the Deflector parallel to the ceiling.
Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats.
Series LFII Residential Recessed Horizontal Sidewall SprinklersThe Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions.
Step A. Recessed horizontal side-wall sprinklers are to be installed in the horizontal position with their center-line of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling.
Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting.
Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats.
Step D. After the wall has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall.
TFP412 Page 3 of 6
TABLE A WET PIPE SYSTEMSSERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA
Max. Coverage Area (a)
Width x Length (d) Ft. x Ft. (m x m)
Max. Spacing
Ft. (m)
WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c)
Ordinary Temp. Rating
155°F (68°C)
Intermediate Temp. Rating
175°F (79°C)Deflector to Ceiling Installation Type
Minimum Spacing Ft. (m)
Flow GPM (L/min)
Pressure PSI (bar)
Flow GPM (L/min)
Pressure PSI (bar)
12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60)13 (49,2)8.7 (0,60)
4 to 6 inches
Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13
8(2,4)
14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70)14 (53,0)10.1 (0,70)
16 x 16 (4,9 x 4,9)16 (4,9)16 (60,6)13.2 (0,91)16 (60,6)13.2 (0,91)
16 x 18 (4,9 x 5,5)16 (4,9)19 (71,9)18.6 (1,28)19 (71,9)18.6 (1,28)
16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88)
18 x 18 (5,5 x 5,5)18 (5,5)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88)
18 x 20 (5,5 x 6,1)18 (5,5)26 (98,4)34.9 (2,41)26 (98,4)34.9 (2,41)
12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60)13 (49,2)8.7 (0,60)
6 to 12 inches
14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70)14 (53,0)10.1 (0,70)
16 x 16 (4,9 x 4,9)16 (4,9)17 (64,3)14.9 (1,03)17 (64,3)14.9 (1,03)
16 x 18 (4,9 x 5,5)16 (4,9)20 (75,7)20.7 (1,43)20 (75,7)20.7 (1,43)
16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88)
18 x 18 (5,5 x 5,5)18 (5,5)23 (87,1)27.3 (1,88)23 (87,1)27.3 (1,88)
18 x 20 (5,5 x 6,1)18 (5,5)26 (98,4)34.9 (2,41)26 (98,4)34.9 (2,41)
(a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated.
(b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section.
(c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used.
(d) The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler).
TFP412Page 4 of 6
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
4
All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Because
of the accuracy of construc tion and design, copper plumbing is more efficient and less expensive.
NIBCO manufactures nine general types of fittings: Wrot Pressure; Cast Pressure; Wrot Drainage; Cast Drainage; Flanges; Flared
Tube; Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each
offers its own advantages when used for the proper service requirement.
ALLOY AND FINISH — NIBCO Fittings are made from highest quality raw materials available — Cast Fittings are made from Copper
Alloy C84400 which consists of 81% Copper, 7% Lead, 3% Tin, and 9% Zinc per ASTM Specification B584. Wrot Copper Fittings are
made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200.
NIBCO fittings are produced to meet requirements of applicable standards wherever practicable.
NIBCO brand wrot and cast fittings are manufactured in the U.S.A. and Mexico. The manufacturing plants at Stuarts Draft, VA,
Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards.
Following is suggested phrasing to be incorporated in your specifications or bills of material for
Copper Tube Fittings.
WROT SOLDER JOINT FITTINGS — “Wrot Solder Joint Fittings shall be produced to one of the following specifications:
1. Material and workmanship shall be in accordance with ASME/ANSI B16.22; Wrought Copper and Copper Alloy Solder Joint
Pressure Fittings.”
Specifications
2. The dimensional, material and workmanship shall
meet the requirements of MSS SP-104; Wrought
Copper Solder Joint Pressure Fittings.”
3. The dimensional, material and workmanship of
5"–12" copper fittings shall meet the requirements
of MSS SP-109 “Welded Fabricated Copper Solder
Joint Pressure Fittings.”
4. Certified to ANSI/NSF 61.
CAST COPPER ALLOY SOLDER JOINT FITTINGS
— “Cast Copper Alloy Solder Joint Fittings shall be in
accor dance with ANSI Std. B16.18.”
WROT DRAINAGE FITTINGS — “Wrot Drainage
Fittings shall be in accordance with ASME/ANSI Std.
B16.29.”
CAST COPPER ALLOY SOLDER JOINT DRAINAGE
FITTINGS — “Cast Copper Alloy Solder Joint Drainage
Fittings shall be in accordance with ASME Std.
B16.23.”
CAST COPPER ALLOY FLARED TUBE FITTINGS — “Cast
Copper Alloy Flared Tube Fittings shall be in accor-
dance with ASME/ANSI Std. B16.26.
CAST COPPER ALLOY FLANGES AND FLANGED
FITTINGS—
CLASS 150 — Cast Copper Alloy Flanges and
Flanged Fittings shall meet the requirements
of MSS SP-106 and/or the workmanship and
dimensions of Federal Specifications WW-F-406 or
ASME Std. B16.24.
CLASS 125 — Material, workmanship and
dimensions of flanges shall be in accordance with
MSS SP-106.
CAST BRONZE THREADED FITTINGS —
“Cast Bronze Threaded Fittings shall be in accordance
with ANSI/ASME B16.15.”
POLYBUTYLENE COPPER INSERT TYPE VALVES AND
FITTINGS — “Wrot Copper Insert Fittings shall be
manufactured per the following specifications:
MSS SP-103 or ASTM F1380.”
NIBCO Copper Tube Fittings are all produced to above
Standards. To simplify, write your specifications to
read: “Copper Tube Fittings to be in accordance with
specifications as outlined in NIBCO Catalog c-cf-0602.”
WROT COPPER MEDICAL MEDICAL GAS SYSTEM
COMPONENTS — Wrot copper fittings that are to be
installed in medical gas applications shall be prepared
in accordance with NFPA 99, Health Care Facilities
Gas and Vacuum Systems and the Compressed
Gas Association, Pamphlet G4.1. Packaging shall
be adequately protective and include labeling that
identifies the preparer and states that the product
has been cleaned and bagged for oxygen or med gas
service.
For technical information and dimensions refer to the
engineering section contained in this catalog.
Revision 3/29/04
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
6
703-2
Fitting Adapter Ftg x F – Cast
APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES
1/2 x 1/4 0.11 17/32
3/4 x 1/2 0.12 19/16
1 x 3/4 0.38 131/32
1 x 1/2 0.15 17/16
2 1/2 1.65 215/16
3 2.47 31/4
703-5 Special
Drop Adapter C x F – Cast
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
1/2 0.16 3/4
3/4 0.24 31/32
703-5B
Drop Adapter C x F – Cast
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
1/2 0.15 3/4
ADAPTERS
603
Adapter C x F – Wrot
APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES
1/8 0.03 13/32
1/8 x 1/4 0.03 1/2
1/4 0.03 5/8
1/4 x 3/8 0.05 21/32
3/8 0.04 11/16
3/8 x 1/2 0.09 29/32
3/8 x 1/4 0.03 9/16
1/2 0.09 27/32
1/2 x 3/4 0.14 1
1/2 x 3/8 0.04 17/32
1/2 x 1/4 0.05 1/2
5/8 x 3/4 0.12 29/32
5/8 x 1/2 0.11 3/4
3/4 0.15 29/32
3/4 x 1 0.21 11/8
3/4 x 1/2 0.10 5/8
1 0.24 31/32
1 x 1 1/4 0.28 17/32
1 x 3/4 0.19 25/32
1 x 1/2 0.24 5/8
1 1/4 0.33 13/32
1 1/4 x 1 1/2 0.40 11/4
1 1/4 x 1 0.27 31/32
1 1/2 0.44 11/8
1 1/2 x 2 0.50 11/32
2 0.63 13/32
2 x 1 1/2 0.74 13/16
2 1/2 1.13 –
3 1.94 –
703
Adapter C x F – Cast
APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES
1/4 x 1/2 0.13 27/32
1/2 x 1 0.30 1
3/4 x 1 1/4 0.55 11/8
3/4 x 3/8 0.17 3/4
1 x 1 1/2 0.68 13/32
1 1/4 x 1 0.27 31/32
1 1/4 x 3/4 0.29 3/4
1 1/2 x 2 0.78 11/32
1 1/2 x 1 0.37 25/32
1 1/2 x 1 1/4 0.47 11/4
2 x 1 1/4 0.76 27/32
2 1/2 1.62 13/8
3 2.34 11/2
4 4.05 19/16
603-2Fitting Adapter Ftg x F – Wrot
APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES
1/4 0.03 13/32
3/8 0.06 13/16
1/2 0.09 17/16
1/2 x 3/8 0.05 11/4
3/4 0.13 111/16
1 0.27 21/32
1 1/4 0.31 21/8
1 1/2 0.43 25/16
2 0.61 217/32
Consult price sheet for Made to Order items and
for minimum order quantities.
Revision 2/6/07
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
9
Consult price sheet for Made to Order items and
for minimum order quantities.
CAPS
617
Tube Cap C – Wrot
APPROX. DIM. N NOM. SIZE NET WT./LBS. INCHES
1/8 0.01 1/32
1/4 0.01 3/32
3/8 0.01 3/32
1/2 0.02 3/32
5/8 0.03 1/8
3/4 0.04 1/8
1 0.07 5/32
1 1/4 0.10 3/32
1 1/2 0.16 1/8
2 0.27 5/32
2 1/2 0.50 7/32
3 0.78 7/32
4 1.66 1/4
717
Tube Cap C – Cast
APPROX. DIM. N NOM. SIZE NET WT./LBS. INCHES
5 5.48 7/16
6 9.07 17/32
717-D
Drain Cap – Cast
APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES
1/2 0.06 21/32
COUPLINGS
600
Reducing Coupling C x C – Wrot
APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES
1/8 x 3/16 O.D. 0.01 5/32
5/16 O.D. x 1/8 0.01 3/16
1/4 x 5/16 O.D. 0.01 3/16
1/4 x 1/8 0.01 3/16
3/8 x 1/4 0.02 3/16
3/8 x 5/16 O.D. 0.01 1/4
3/8 x 1/8 0.01 1/4
1/2 x 3/8 0.03 3/16
1/2 x 1/4 0.02 1/4
1/2 x 1/8 0.03 11/32
5/8 x 1/2 0.05 3/16
5/8 x 3/8 0.04 11/32
5/8 x 1/4 0.03 13/32
3/4 x 5/8 0.07 3/16
3/4 x 1/2 0.06 9/32
3/4 x 3/8 0.06 3/8
3/4 x 1/4 0.05 11/32
1 x 3/4 0.11 11/32
1 x 5/8 0.09 3/8
1 x 1/2 0.10 11/32
1 x 3/8 0.10 13/32
1 1/4 x 1 0.16 5/16
1 1/4 x 3/4 0.18 17/32
1 1/4 x 5/8 0.18 5/8
1 1/4 x 1/2 0.14 7/16
1 1/2 x 1 1/4 0.23 5/16
1 1/2 x 1 0.22 9/16
1 1/2 x 3/4 0.20 3/8
1 1/2 x 1/2 0.19 1/2
2 x 1 1/2 0.41 9/16
2 x 1 1/4 0.35 11/16
2 x 1 0.37 7/16
2 x 3/4 0.34 17/32
2 x 1/2 0.35 23/32
2 1/2 x 2 0.59 9/16
2 1/2 x 1 1/2 0.65 11/16
2 1/2 x 1 1/4 0.65 13/16
2 1/2 x 1 0.73 29/32
Continues…
APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES
3 x 2 1/2 0.98 1/2
3 x 2 1.06 15/16
3 x 1 1/2 0.92 11/32
3 1/2 x 3 1.52 1/2
4 x 3 1/2 2.12 19/32
4 x 3 1.92 27/32
4 x 2 1/2 1.77 1
4 x 2 1.92 11/4
5 x 4 3.50 331/32
5 x 3 3.18 115/32
5 x 2 1/2 3.50 13/16
5 x 2 3.09 21/32
6 x 5 5.70 11/8
6 x 4 5.24 11/2
6 x 3 5.04 2
6 x 2 1/2 5.13 21/4
6 x 2 4.89 21/2
8 x 6 13.06 119/32
8 x 4 12.22 219/32
8 x 3 11.79 33/32
8 x 2 1/2 12.64 33/8
600-RS
Coupling with Rolled Tube Stop
C x C – Wrot
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
1/8 O.D. 0.01 1/16
3/16 O.D. 0.01 3/32
1/8 0.01 1/16
5/16 O.D. 0.01 3/32
1/4 0.01 1/16
3/8 0.01 3/32
1/2 0.03 3/32
5/8 0.04 3/32
3/4 0.06 3/32
7/8 0.09 3/32
1 0.11 3/32
1 1/4 0.16 1/8
1 1/2 0.23 1/8
2 0.41 1/8
2 1/2 0.65 1/8
3 0.93 1/8
3 1/2 1.45 5/32
4 1.93 7/32
Revision 2/6/07
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
12
ELBOWS continued
Consult price sheet for Made to Order items and
for minimum order quantities.
706-2
45° Fitting Elbow Ftg x C – Cast
APPROX. DIM. B DIM. C NOM. SIZE NET WT./LBS. INCHES INCHES
4 4.31 311/32 15/16
607
90° Elbow – Close Rough
C x C – Wrot
APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES
1/8 0.01 13/32 13/32
1/4 0.02 9/32 9/32
3/8 0.03 1/2 1/2
1/2 0.04 3/8 3/8
1/2 x 3/8 0.04 9/16 21/32
3/4 0.10 17/32 17/32
3/4 x 5/8 0.12 29/32 7/8
3/4 x 1/2 0.10 17/32 3/4
1 0.21 23/32 23/32
1 x 3/4 0.16 23/32 5/8
1 1/4 0.31 11/32 11/32
1 1/4 x 1 0.31 15/8 115/32
1 1/2 0.46 17/32 17/32
1 1/2 x 1 1/4 0.35 15/32 13/32
2 0.84 11/2 11/2
2 x 1 1/2 0.58 17/16 11/4
2 1/2 1.41 127/32 127/32
3 2.07 23/32 23/32
3 1/2 2.94 23/8 23/8
4 4.23 225/32 225/32
5 7.74 27/8 27/8
6 10.95 37/16 37/16
8 29.50 423/32 423/32
707
90° Elbow – Close Rough
C x C – Cast
APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES
1 1/4 x 1 0.42 15/8 115/32
1 1/4 x 3/4 0.34 9/16 13/16
1 1/4 x 1/2 0.28 15/32 27/32
1 1/2 x 1 0.54 11/16 1
1 1/2 x 3/4 0.42 19/32 31/32
1 1/2 x 1/2 0.40 5/8 29/32
2 x 1 1/4 0.86 7/8 11/4
2 x 1 0.78 3/4 11/4
2 x 3/4 0.69 5/8 11/4
2 1/2 x 2 2.16 13/16 19/32
3 x 2 1/2 2.26 111/16 11/2
3 x 2 2.68 13/8 19/16
4 x 3 5.18 129/32 215/32
607-I
90° Elbow –
Intermediate Radius C x C
– Wrot
APPROX. DIM. C DIM. D
NOM. SIZE NET WT./LBS. INCHES INCHES
1/2 0.06 19/32 19/32
5/8 0.09 7/8 7/8
3/4 0.14 13/16 3/16
1 0.24 11/16 11/16
607-LT
90° Elbow – Long Radius
C x C – Wrot
APPROX. DIM. C DIM. D NOM. SIZE NET WT./LBS. INCHES INCHES
3/16 O.D. 0.01 13/32 13/32
1/8 0.01 13/32 13/32
5/16 O.D. 0.02 9/16 9/16
1/4 0.02 17/32 17/32
1/4 x 1/8 0.01 19/32 1/2
3/8 0.04 23/32 23/32
1/2 0.08 7/8 7/8
1/2 x 3/8 0.06 13/16 13/16
1/2 x 1/4 0.03 25/32 21/32
5/8 0.10 13/32 13/32
5/8 x 1/2 0.09 11/16 11/16
3/4 0.16 11/8 11/8
3/4 x 5/8 0.13 11/4 13/32
3/4 x 1/2 0.10 11/8 11/16
7/8 0.28 119/32 119/32
1 0.28 17/16 17/16
1 x 3/4 0.20 11/4 11/8
1 x 5/8 0.15 113/32 13/32
1 1/4 0.42 17/8 17/8
1 1/4 x 1 0.33 125/32 11/2
1 1/2 0.66 21/4 21/4
2 1.23 215/16 215/16
2 1/2 1.96 311/16 311/16
3 2.93 41/32 41/32
4 5.95 51/4 51/4
Revision 2/7/07
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
15
707-6
90° Union Elbow C x C – Cast
APPROX. DIM. A DIM. C NOM. SIZE NET WT./LBS. INCHES INCHES
3/8 0.17 31/32 5/16
1/2 0.24 1 7/16
3/4 0.39 117/32 9/16
1 0.64 121/32 23/32
1 1/4 1.07 119/32 23/32
708
90° Flanged Sink Elbow
C x F – Cast
NOM. APPROX. DIM. A DIM. C DIM. F SIZE NET WT./LBS. INCHES INCHES INCHES
1/2 0.20 7/8 9/16 13/4
764
90° Double Elbow
C x C x C – Cast
APPROX. DIM. C DIM. D
NOM. SIZE NET WT./LBS. INCHES INCHES
1 x 3/4 x 3/4 0.33 3/4 21/32
ELBOWS continued
Consult price sheet for Made to Order items and
for minimum order quantities.
FITTING REDUCERS
APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES
4 x 3 1/2 2.09 25/8
4 x 3 2.00 31/32
4 x 2 1/2 1.56 31/32
4 x 2 1.76 313/32
5 x 4 3.30 39/16
5 x 3 2.97 41/16
5 x 2 1/2 3.30 411/32
5 x 2 2.88 411/16
6 x 5 5.56 43/16
6 x 4 5.09 49/16
6 x 3 4.67 51/16
6 x 2 1/2 4.47 511/32
6 x 2 4.51 519/32
8 x 6 12.33 515/32
8 x 5 10.35 515/16
8 x 4 11.10 67/16
8 x 3 10.63 615/16
8 x 2 1/2 11.41 73/16
8 x 2 10.86 77/16
741
Companion Flange C – Cast
NOM. APPROX. DIM. B DIM. F DIM. G DIM. W
SIZE NET WT./LBS. INCHES INCHES INCHES INCHES
1/2 0.55 1/8 31/2 3/16 23/8
3/4 0.71 1/8 37/8 3/16 23/4
1 1.26 1/8 41/4 1/4 31/8
1 1/4 1.42 1/8 45/8 1/4 31/2
1 1/2 1.82 1/8 5 5/16 37/8
2 2.76 1/8 6 3/8 43/4
2 1/2 4.29 1/8 7 3/8 51/2
3 5.26 1/8 71/2 7/16 6
4 7.60 1/8 9 7/16 71/2
5 9.04 1/8 10 7/16 81/2
6 12.68 1/8 11 1/2 91/2
NOTE: Dim. B = Tube Stop to Flange Face
600-2
Fitting Reducer Ftg x C – Wrot
APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES
1/4 x 1/8 0.01 15/32
3/8 x 1/4 0.01 19/32
3/8 x 1/8 0.01 25/32
1/2 x 3/8 0.03 11/16
1/2 x 1/4 0.02 25/32
5/8 x 1/2 0.04 7/8
5/8 x 3/8 0.04 31/32
5/8 x 1/4 0.03 11/32
3/4 x 5/8 0.06 31/32
3/4 x 1/2 0.06 11/8
3/4 x 3/8 0.05 11/8
3/4 x 1/4 0.05 13/32
1 x 3/4 0.10 17/32
1 x 5/8 0.09 13/8
1 x 1/2 0.09 11/4
1 x 3/8 0.08 19/32
1 1/4 x 1 0.15 15/16
1 1/4 x 3/4 0.16 11/2
1 1/4 x 1/2 0.13 13/8
1 1/2 x 1 1/4 0.23 113/32
1 1/2 x 1 0.21 15/8
1 1/2 x 3/4 0.20 17/8
1 1/2 x 1/2 0.16 119/32
2 x 1 1/2 0.40 131/32
2 x 1 1/4 0.34 23/32
2 x 1 0.35 127/32
2 x 3/4 0.35 127/32
2 x 1/2 0.34 131/32
2 1/2 x 2 0.65 131/32
2 1/2 x 1 1/2 0.65 23/8
2 1/2 x 1 1/4 0.60 27/32
2 1/2 x 1 0.78 29/32
3 x 2 1/2 1.03 21/4
3 x 2 0.99 29/16
3 x 1 1/2 0.81 219/32
3 x 1 1/4 1.29 31/4
3 1/2 x 3 1.48 211/32
Continues…
FLANGES –
CLASS 125
Revision 2/8/07
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
18
APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G
1 x 1/2 x 1 0.29 11/16 1 21/32
1 x 1/2 x 3/4 0.27 9/16 13/16 3/4
1 x 1/2 x 1/2 0.22 15/32 25/32 23/32
1 1/4 0.43 13/16 3/16 13/16
1 1/4 x 1 1/4 x 2 1.13 130/32 130/32 13/32
1 1/4 x 1 1/4 x 1 1/2 0.60 13/16 13/16 29/32
1 1/4 x 1 1/4 x 1 0.45 25/32 25/32 29/32
1 1/4 x 1 1/4 x 3/4 0.37 21/32 21/32 3/4
1 1/4 x 1 1/4 x 1/2 0.30 1/2 1/2 25/32
1 1/4 x 1 1/4 x 3/8 0.34 23/32 23/32 29/32
1 1/4 x 1 x 1 1/4 0.43 13/16 11/32 13/16
1 1/4 x 1 x 1 0.47 25/32 7/8 29/32
1 1/4 x 1 x 3/4 0.35 21/32 25/32 7/8
1 1/4 x 1 x 1/2 0.30 1/2 5/8 29/32
1 1/4 x 3/4 x 1 1/4 0.42 13/16 11/8 13/16
1 1/4 x 3/4 x 1 0.45 25/32 11/32 29/32
1 1/4 x 3/4 x 3/4 0.37 21/32 15/16 7/8
1 1/4 x 3/4 x 1/2 0.30 1/2 3/4 29/32
1 1/4 x 1/2 x 1 1/4 0.41 13/16 17/32 13/16
1 1/2 0.61 31/32 31/32 29/32
1 1/2 x 1 1/2 x 2 1.11 125/32 125/32 13/32
1 1/2 x 1 1/2 x 1 1/4 0.62 29/32 29/32 11/16
1 1/2 x 1 1/2 x 1 0.55 11/16 11/16 7/8
1 1/2 x 1 1/2 x 3/4 0.45 11/16 11/16 11/32
1 1/2 x 1 1/2 x 1/2 0.40 1/2 1/2 11/32
1 1/2 x 1 1/4 x 1 1/2 0.62 11/32 13/16 29/32
1 1/2 x 1 1/4 x 1 1/4 0.62 31/32 13/32 31/32
1 1/2 x 1 1/4 x 1 0.51 25/32 1 11/32
1 1/2 x 1 1/4 x 3/4 0.49 11/16 13/16 11/32
1 1/2 x 1 1/4 x 1/2 0.41 1/2 25/32 11/32
1 1/2 x 1 x 1 1/2 0.59 11/32 111/32 29/32
1 1/2 x 1 x 1 1/4 0.63 29/32 11/8 11/16
1 1/2 x 1 x 1 0.54 25/32 11/16 11/32
1 1/2 x 1 x 3/4 0.44 11/16 31/32 15/16
1 1/2 x 1 x 1/2 0.39 1/2 25/32 11/32
1 1/2 x 3/4 x 1 1/2 0.62 11/32 17/16 11/16
1 1/2 x 3/4 x 1 1/4 0.58 29/32 111/32 11/16
1 1/2 x 3/4 x 1 0.54 25/32 11/4 11/32
1 1/2 x 3/4 x 3/4 0.47 11/16 13/32 29/32
1 1/2 x 3/4 x 1/2 0.39 1/2 29/32 31/32
1 1/2 x 1/2 x 1 1/2 0.62 11/32 113/32 31/32
Continues…
APPROX. DIMENSIONS
NET WT. INCHES
NOM. SIZE LBS. C F G
2 1.30 19/32 19/32 11/32
2 x 2 x 2 1/2 2.34 2 2 121/32
2 x 2 x 1 1/2 1.17 11/4 11/4 123/32
2 x 2 x 1 1/4 1.12 9/32 9/32 17/8
2 x 2 x 1 0.90 27/32 27/32 11/4
2 x 2 x 3/4 0.88 19/32 19/32 11/4
2 x 2 x 1/2 1.17 11/4 11/4 21/4
2 x 1 1/2 x 2 1.16 19/32 17/8 111/32
2 x 1 1/2 x 1 1/2 1.15 11/4 13/4 123/32
2 x 1 1/2 x 1 1/4 1.15 7/32 13/4 111/32
2 x 1 1/2 x 3/4 0.83 21/32 15/16 17/32
2 x 1 1/2 x 1/2 1.12 11/4 125/32 21/4
2 x 1 1/4 x 2 1.58 19/32 115/32 19/32
2 x 1 1/4 x 1 1/2 1.16 11/4 131/32 123/32
2 x 1 1/4 x 1 1/4 1.19 15/16 111/32 111/32
2 x 1 1/4 x 1 0.90 27/32 19/32 111/32
2 x 1 1/4 x 3/4 0.85 21/32 1 18/27
2 x 1 x 2 1.11 11/8 125/32 11/4
2 x 1 x 1 0.89 27/32 19/32 111/32
2 x 3/4 x 2 1.15 19/32 23/16 11/4
2 x 1/2 x 2 1.15 19/32 23/8 11/4
2 1/2 2.40 15/8 15/8 15/8
2 1/2 x 2 1/2 x 2 1.97 15/16 15/16 121/32
2 1/2 x 2 1/2 x 1 1/2 1.53 13/32 13/32 121/32
2 1/2 x 2 1/2 x 1 1/4 1.72 13/32 13/32 127/32
2 1/2 x 2 1/2 x 1 1.34 25/32 25/32 111/16
2 1/2 x 2 1/2 x 3/4 1.34 25/32 25/32 113/16
2 1/2 x 2 1/2 x 1/2 1.34 25/32 25/32 21/8
2 1/2 x 2 x 2 1/2 1.99 121/32 23/32 121/32
2 1/2 x 2 x 2 1.95 111/32 15/8 123/32
2 1/2 x 2 x 1 1/2 1.57 13/32 213/32 121/32
2 1/2 x 2 x 1 1/4 1.57 13/32 119/32 127/32
2 1/2 x 2 x 1 1.40 25/32 19/32 13/4
2 1/2 x 2 x 3/4 1.35 25/32 19/32 127/32
2 1/2 x 1 1/2 x 1 1/2 1.76 13/32 113/32 13/8
2 1/2 x 1 1/4 x 2 1/2 2.40 121/32 27/16 121/32
2 1/2 x 1 x 2 1/2 2.04 121/32 223/32 121/32
2 1/2 x 3/4 x 2 1/2 2.00 121/32 211/16 121/32
2 1/2 x 1/2 x 2 1/2 2.46 11/2 27/32 11/2
Continues…
APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G
3 3.15 17/8 17/8 21/32
3 x 3 x 2 1/2 3.55 129/32 129/32 23/8
3 x 3 x 2 3.19 115/32 115/32 131/32
3 x 3 x 1 1/2 3.08 115/32 115/32 29/32
3 x 3 x 1 1/4 3.10 115/32 115/32 27/16
3 x 3 x 1 2.12 27/32 27/32 131/32
3 x 3 x 3/4 2.39 27/32 27/32 23/16
3 x 3 x 1/2 1.82 27/32 27/32 23/8
3 x 2 1/2 x 3 3.08 17/8 23/8 131/32
3 x 2 1/2 x 2 1/2 3.12 129/32 211/32 25/32
3 x 2 1/2 x 2 2.28 115/32 127/32 131/32
3 x 2 x 3 3.62 129/32 217/32 115/16
3 x 2 x 2 1/2 3.56 129/32 29/16 25/16
3 x 2 x 2 3.22 115/32 131/32 131/32
3 x 1 1/2 x 3 3.13 129/32 225/32 23/32
3 x 1 1/4 x 3 3.63 129/32 225/32 115/16
3 x 1 x 3 3.20 131/32 219/32 23/16
3 x 3/4 x 3 3.55 131/32 229/32 23/16
3 1/2 5.20 217/32 217/32 217/32
4 8.12 213/32 213/32 217/32
4 x 4 x 3 6.70 21/32 21/32 221/32
4 x 4 x 2 1/2 6.65 21/32 21/32 35/32
4 x 4 x 2 5.82 115/32 115/32 27/16
4 x 4 x 1 1/2 3.94 111/32 111/32 217/32
4 x 4 x 1 1/4 4.04 111/32 111/32 229/32
4 x 4 x 1 3.72 1 1 29/16
4 x 4 x 3/4 3.70 1 1 211/16
4 x 3 x 4 7.05 225/32 37/32 217/32
4 x 3 x 3 5.03 21/32 215/32 215/32
4 x 3 x 2 1/2 5.04 21/32 215/32 229/32
4 x 3 x 2 5.87 115/32 131/32 27/16
4 x 2 1/2 x 4 7.19 225/32 315/32 227/32
4 x 2 x 4 7.08 225/32 319/32 227/32
Continued on next page.
NOTE: Tee sizes are read Run x Run x Outlet.
611
Tee C x C x C – Wrot continued
TEES continued
Consult price sheet for Made to Order items and
for minimum order quantities.
Revision 2/8/07
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
49
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
Copper Water Tube continued
DIMENSIONAL DATA – COPPER WATER TUBE – TYPE “M”
TYPE “M” Hard Drawn Only: 20-ft. (6.1m) Straight Lengths
Usage: For general purpose plumbing, heating and
drainage installations.
Tolerances Hard Drawn
(Hard Drawn Only)
Outside Tubing OD Nominal Wall Weight Bursting Safe Working
Nominal Diameter Thickness Per Foot PressureA PressureB
Water Tube Min. Max.
Size (In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars)
1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A
3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59)
1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51)
5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A
3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42)
1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35)
1 1/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35)
1 1/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34)
2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31)
2 1/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28)
3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26)
3 1/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26)
4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26)
5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24)
6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23)
8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24)
10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24)
12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24)
Note: Information and data contained in these charts, as taken from ASTM Specifications B 88.
Rated internal pressure for copper water tube based on the strength of the tube alone and
applicable to systems using suitable mechanical joints.
A Based on actual laboratory test data provided by Copper Development Association, Inc.
B Based upon 150°F (65.6°C) with an allowable stress of 9500 psi (668 kPa).
Revision 5/12/02
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
62
1" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm)
Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 1.0558 inches (26.797 mm)
Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.8742 sq. inches (563.98 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity
(GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.)
2.50 0.18 0.41 0.92 158 0.04 0.41 0.28
5.00 0.64 1.49 1.84 315 0.14 1.49 0.56
7.50 1.36 3.15 2.75 473 0.31 3.15 0.84
10.00 2.31 5.37 3.67 631 0.52 5.37 1.12
12.50 3.49 8.11 4.59 789 0.79 8.11 1.40
15.00 4.90 11.36 5.51 946 1.11 11.36 1.68
17.50 6.52 15.11 6.42 1104 1.47 15.11 1.96
20.00 8.34 19.35 7.34 1262 1.89 19.35 2.24
22.50 10.38 24.06 8.26 1419 2.35 24.06 2.52
25.00 12.61 29.24 9.18 1577 2.85 29.24 2.80
27.50 15.05 34.88 10.09 1735 3.40 34.88 3.08
30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36
32.50 20.51 47.51 11.93 2050 4.64 47.51 3.64
35.00 23.52 54.49 12.85 2208 5.32 54.49 3.92
37.50 26.73 61.91 13.76 2366 6.05 61.91 4.19
40.00 30.12 69.76 14.68 2523 6.81 69.76 4.47
42.50 33.70 78.04 15.60 2681 7.62 78.04 4.75
45.00 37.47 86.74 16.52 2839 8.47 86.74 5.03
47.50 41.41 95.87 17.43 2997 9.37 95.87 5.31
50.00 45.54 105.41 18.35 3154 10.30 105.41 5.59
52.50 49.84 115.37 19.27 3312 11.28 115.37 5.87
55.00 54.33 125.74 20.19 3470 12.29 125.74 6.15
1 1/4" TYPE “K” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm)
Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2450 inches (31.623 mm)
Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 1.2174 sq. inches (785.41 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity
(GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.)
5.00 0.29 0.67 1.32 315 0.06 0.67 0.40
10.00 1.03 2.40 2.64 631 0.23 2.40 0.80
15.00 2.19 5.08 3.95 946 0.49 5.08 1.20
20.00 3.73 8.65 5.27 1262 0.84 8.65 1.61
25.00 5.64 13.06 6.59 1577 1.27 13.06 2.01
30.00 7.90 18.30 7.91 1893 1.79 18.30 2.41
35.00 10.51 24.34 9.22 2208 2.38 24.34 2.81
40.00 13.46 31.17 10.54 2523 3.04 31.17 3.21
45.00 16.74 38.75 11.86 2839 3.79 38.75 3.61
50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02
55.00 24.27 56.18 14.49 3470 5.49 56.18 4.42
60.00 28.52 65.99 15.81 3785 6.45 65.99 4.82
65.00 33.07 76.52 17.13 4101 7.48 76.52 5.22
70.00 37.94 87.76 18.45 4416 8.58 87.76 5.62
75.00 43.11 99.71 19.77 4732 9.75 99.71 6.02
80.00 48.58 112.35 21.08 5047 10.99 112.35 6.43
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
Revision 5/12/02
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
63
1 1/4" TYPE “L” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.375 inches (34.925 mm)
Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.265 inches (32.131 mm)
Nominal Wall Thickness = 0.0550 inches (1.397 mm) Flow Area = 1.2568 sq. inches (810.85 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity
(GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.)
5.00 0.26 0.62 1.28 315 0.06 0.62 0.39
10.00 0.96 2.22 2.55 631 0.22 2.22 0.78
15.00 2.02 4.70 3.83 946 0.46 4.70 1.17
20.00 3.45 8.00 5.11 1262 0.78 8.00 1.56
25.00 5.22 12.09 6.38 1577 1.18 12.09 1.95
30.00 7.31 16.94 7.66 1893 1.65 16.94 2.33
35.00 9.73 22.53 8.93 2208 2.20 22.53 2.72
40.00 12.45 28.84 10.21 2523 2.82 28.84 3.11
45.00 15.49 35.86 11.49 2839 3.50 35.86 3.50
50.00 18.83 43.58 12.76 3154 4.26 43.58 3.89
55.00 22.46 51.98 14.04 3470 5.08 51.98 4.28
60.00 26.39 61.06 15.32 3785 5.97 61.06 4.67
65.00 30.61 70.81 16.59 4101 6.92 70.81 5.06
70.00 35.11 81.21 17.87 4416 7.94 81.21 5.45
75.00 39.89 92.27 19.15 4732 9.02 92.27 5.84
80.00 44.96 103.97 20.42 5047 10.17 103.97 6.22
1 1/4" TYPE “M” COPPER TUBE — WATER FLOW AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm)
Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2910 inches (32.7914 mm)
Nominal Wall Thickness = 0.0420 inches (1.067 mm) Flow Area = 1.3090 sq. inches (844.52 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q Pressure Loss Head Loss Velocity FLOW, Q Pressure Loss Head Loss Velocity
(GPM) (psi/100 ft) (ft/100 ft) (ft./sec.) (cu. cm/sec.) (kPa/100 m) (m/100 m) (m/sec.)
5.00 0.24 0.56 1.23 315 0.05 0.56 0.37
10.00 0.87 2.01 2.45 631 0.20 2.01 0.75
15.00 1.83 4.26 3.68 946 0.41 4.26 1.12
20.00 3.12 7.25 4.90 1262 0.71 7.25 1.49
25.00 4.72 10.95 6.13 1577 1.07 10.95 1.87
30.00 6.62 15.34 7.35 1893 1.50 15.34 2.24
35.00 8.81 20.40 8.58 2208 1.99 20.40 2.61
40.00 11.28 26.12 9.80 2523 2.55 26.12 2.99
45.00 14.03 32.48 11.03 2839 3.17 32.48 3.36
50.00 17.05 39.47 12.25 3154 3.86 39.47 3.74
55.00 20.34 47.08 13.48 3470 4.60 47.08 4.11
60.00 23.90 55.31 14.71 3785 5.41 55.31 4.48
65.00 27.72 64.14 15.93 4101 6.27 64.14 4.86
70.00 31.80 73.56 17.16 4416 7.19 73.56 5.23
75.00 36.13 83.57 18.38 4732 8.17 83.57 5.60
80.00 40.72 94.17 19.61 5047 9.21 94.17 5.98
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
Revision 5/12/02
A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
81
Copper Water Tube continued
COPPER TUBE – TYPES, STANDARDS, APPLICATIONS, TEMPERS AND LENGTHS
Commercially Available Lengths
Tube Type Color Code Standard Application Nominal or Standard Sizes Drawn Annealed
Type K Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 8-inch 20 ft. (6.1m) 20 ft. (6.1m)
Fire Protection 10-inch 18 ft. (5.5m) 18 ft. (5.5m)
Solar 12-inch 12 ft. (3.7m) 12 ft. (3.7m)
Fuel/Fuel Oil Coils: 1/4-inch to 1-inch – 60 ft. (18.3m)
HVAC – 100 ft. (30.5m)
Snow Melting 11/4-inch & 11/2-inch – 60 ft. (18.3m)
2-inch – 40 ft. (12.2m)
– 45 ft. (13.7m)
Type L Blue ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 10-inch 20 ft. (6.1m) 20 ft. (6.1m)
Fire Protection 12-inch 18 ft. (5.5m) 18 ft. (5.5m)
Solar
Fuel/Fuel Oil
Natural Gas Coils: 1/4-inch to 1-inch – 60 ft. (18.3m)
Liquified Petroleum (LP) Gas – 100 ft. (30.5m)
HVAC 11/4-inch & 11/2-inch – 60 ft. (18.3m)
Snow Melting 2-inch – 40 ft. (12.2m)
– 45 ft. (13.7m)
Type M Red ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 12-inch 20 ft. (6.1m) N/A
Fire Protection
Solar
Fuel/Fuel Oil
HVAC
Snow Melting
DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft. (6.1m) N/A
Waste
Vent
HVAC
Solar
ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 41/8-inch 20 ft. (6.1m) 20 ft. (6.1m)1
Refrigeration
Natural Gas Coils: 1/8-inch to 15/8-inch – 50 ft. (15.3m)1
Liquified Petroleum (LP) Gas
OXY Type K ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft. (6.1m) N/A
MED Green
OXY/MED
OXY/ACR Type L
ACR/MED Blue
Type G Yellow ASTM B 837 Natural Gas Straight Lengths: 3/8-inch to 11/8-inch 12 ft. (3.7m) 12 ft. (3.7m)1
Liquified Petroleum (LP) Gas 20 ft. (6.1m) 20 ft. (6.1m)1
Coils: 3/8-inch to 7/8-inch – 60 ft. (18.3m)1
– 100 ft. (30.5m)1
1 Available as special order only.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
Revision 5/12/02
PHD Manufacturing, Inc. • 44018 Columbiana-Waterford Road • Columbiana, OH 44408Toll Free (800) 321-2736 • Phone: (330) 482-9256 • Fax: (330) 482-2763 • www.phd-mfg.com
AdjustAble swivel Ring HAngeRs
FUNCTION: Designed for the suspension of non-insulated stationary pipe lines. The knurled insert nut that allows a vertical adjustment after installation, is tapped to NFPA reduced rod size standards. Fig. 141F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound.
APPROVALS: Underwriters’ Laboratories Listed in the U.S. (UL), Canada (CUL), and Factory Mutual Approved for sizes 3⁄4" to 8". Complies with Federal Specifications A-A-1192A (Type 10), and Manufacturers’ Standardization Society ANSI/SP-69 and SP-58 (Type 10).
ORDERING: Specify pipe size and figure number.
Fig. 141 & 141FNFPA SWIVELRING HANGER
Fig. 141 PRE-GALVANIZED
Fig. 141F PRE-GALVANIZED WITH FELT LINING
FUNCTION: Designed for the suspension of non-insulated stationary pipe lines. The knurled insert nut, allows for vertical adjustment after installation. Fig. 151F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound.
APPROVALS: Underwriters’ Laboratories Listed in the U.S. (UL) and Factory Mutual Approved for all sizes. Complies with Federal Specification A-A-1192A (Type 10), and Manufacturers’ Standardization Society ANSI/SP-69 and SP-58 (Type 10).
ORDERING: Specify pipe size and figure number.
Fig. 151 & 151FSWIVELRING HANGER
Fig. 151 PRE-GALVANIZED
Fig. 151F PRE-GALVANIZED WITH FELT LINING
Note: If ordering Fig. 151F felt lined hangers for pipe sizes of 31/2" or under, order the next largest size to allow for the thickness of the felt lining.
MATERIAL: Low carbon steel
RodSizeA
Max. Rec.Load/lbs.Wt. Each(in lbs.)PipeSize B Adj.C D E
RodSizeA
PipeSize Wt. Each(in lbs.)Max. Rec.Load/lbs.Adj.CB D E
Note: If ordering Fig. 141F felt lined hangers for pipe sizes of 31/2" or under, order the next largest size to allow for the thickness of the felt lining.MATERIAL: Low carbon steel
1/2 3/8 17/8 17/16 23/4 31/16 300 .10
3/4 3/8 111/16 11/8 21/2 31/16 300 .10
1 3/8 15/8 1 21/2 33/16 300 .10
11/4 3/8 115/16 11/16 213/16 39/16 300 .11
11/2 3/8 21/8 11/16 31/8 37/8 300 .11
2 3/8 27/16 11/8 35/16 43/8 300 .14
21/2 3/8 31/16 15/8 315/16 53/8 525 .19
3 3/8 311/16 17/8 49/16 65/16 525 .23
31/2 3/8 33/4 17/8 45/8 65/8 525 .25
4 3/8 43/16 17/8 51/16 75/16 650 .30
5 1/2 45/8 15/8 55/8 83/8 1000 .50
6 1/2 55/8 21/4 61/2 913/16 1000 .58
8 1/2 613/16 27/16 715/16 121/4 1000 .90
21/2 1/2 23/4 11/4 311/16 51/8 600 .33
3 1/2 31/8 11/8 4 57/8 600 .35
31/2 1/2 35/8 11/2 45/16 65/8 600 .37
4 5/8 37/8 11/4 415/16 71/8 1000 .48
5 5/8 43/8 13/8 55/8 81/2 1000 .57
6 3/4 55/16 2 611/16 101/8 1250 1.06
8 3/4 615/16 25/8 85/16 127/8 1250 1.32
PHD Manufacturing, Inc. • 44018 Columbiana-Waterford Road • Columbiana, OH 44408Toll Free (800) 321-2736 • Phone: (330) 482-9256 • Fax: (330) 482-2763 • www.phd-mfg.com
THREADED ACCESSORIES
Fig. 40 COACH SCREW ROD
3/8 2 2 390 .12 .19 .25 .31 .37
1/2 2 21/2 640 .22 .34 .44 .56 .67
Max. Rec.Load/lbs. 6 8 10 124
Wt. Each (in lbs.)
Length D (inches)
Minimum Length
MachineB CoachC
RodSizeA
FUNCTION: Designed for use as a vertical hanger attachment to wood structures.
MATERIAL: Low carbon steel
FINISH: Plain or electro-galvanized
ORDERING: Specify rod size, length, finish and figure number.