Loading...
HomeMy WebLinkAboutVail Summit Orthopedics TF Fire Sprinkler Submittals.pdf Fire Sprinkler Equipment Submittal For Vail Summit Orthopedics 108 S. Frontage Road, Suite 206 Vail, CO 81657 Edward Kolecke NICET Level III # 94588 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Standard Spray Bulletin 014 Rev. KBulletin 014 Rev. K Model F1FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Upright Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Pendent Model F1FR56LL & F1FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhütung GmbH 5. *NSF Certified to NSF/ANSi Standard 61 Annex G UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall RecessedPendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP to apply water to a fire much faster than standard sprinklers of the same tem- perature rating. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. 2. Technical data: Models Discharge Coeffi cient Response Thread Size Max. Working Pressure Min. Working Pressure Temperature Rating Finish F1FR56 **F1FR56LL(1)K 5.6 Quick Response 1/2” NPT (R1/2) 175 PSI 7 PSI See “Temperature Ratings” Table. See “Finish Table” F1FR42 **F1FR42LL(1) F1FRXLH K 4.2 F1FR28 K 2.8 (1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Defl ector Load Screw *Pintle Cup Washer Bulb DZR Brass QM Brass **Low Lead Brass CDA Alloy 260, CDA Alloy 220 orCDA Alloy510 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 651 or CDA Alloy 693 Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape Glass Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. Model F1FR42, F1FRXLH Upright Pendent ConventionalUpright Model F1FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Nominal K Factor Sprinkler Approval Sprinkler Identifi cation Number (SIN) Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1)1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1,2,3,4 RA1425 (1)(2)(3)(4)RA1414(1)(2)(3)(4) 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1 RA1423 (1)(4)RA1413(4) 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) 1 RA1421 (1)(4)RA1411(4) Conventional-Install in Upright or Pendent Position 15mm (1)1/2” NPT (R1/2) 5.6 80 57mm 3, 4 RA1475 (3) (1) cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. (3) Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant 3. Model F1FR56LL & F1FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Nominal K Factor Sprinkler Approval Sprinkler Identifi cation Number (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1)1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1,5 RA1415 7/16” (11mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1,5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark Model F1FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifi ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler Identifi cation Numbers (SIN)US Metric ½” (15mm) ½” NPT (R1/2) 5.6 80 2.25” (57mm) 1,2,3 RA1485(2)(3)15mm ½” NPT (R1/2) 5.6 80 2.25” (57mm) 3 (1) (1) LPC Approval is for pendent position only. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Sprinkler Type Defl ector to Ceiling Distance (Min. - Max.) Upright 4” (102mm) - 12” (305mm) Pendent 4” (102mm) - 12” (305mm) Vertical Sidewall Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 F1 or F2 Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model F1FR56, F1FR42, F1FRXLH & F1FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Size K Factor Sprinkler Height Sprinkler Identifi cation Number (SIN)US Metric 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1414 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1413 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model F1FR56LL & F1FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Size K Factor Sprinkler Height Sprinkler Identifi cation Number (SIN)US Metric 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1415 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions 4.*DuPont Registered Trademark 5. Model F1FR56 Quick Response Horizontal Sidewall Sprinkler Defl ector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal Orifi ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations and Type of Approval Sprinkler Identifi cation Numbers (SIN)US Metric Light Hazard Ordinary Hazard ½” (15mm) ½” NPT (R1/2) 5.6 80 2.63” (67mm) 1,2 1 RA1435 (1)(2)(3) (1) cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. (3) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with F1, F2 or FP escutcheons for “Light Hazard” only. While FM limits use for the same hazard with the F2 escutcheon only. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifi ce “K” Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identifi cation Number(SIN)US Metric Sprinkler Cover ½” (15mm) 5.6 80 ½” NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 4 (1)RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 200°F/93°C 165°F/74°C 150°F/65°C Green 1 RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2” [12,7mm] adjustment. Model F1FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifi ce “K” Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identifi cation Number(SIN)US Metric Sprinkler Cover ½” (15mm) 5.6 80 ½” NPT F1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1, 5 RA1414 *DuPont Registered Trademark Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model F1 or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½” orifice, ½” NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the F1FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- gagement. A choice of two cover plate assemblies provide either 1/2” (13mm) or 5/8” (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 25/8” (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. 6. *DuPont Registered Trade Mark Figure 1 Figure 2 Temperature Ratings Classifi cation Sprinkler Temperature Max. Ambient Temp.Bulb Color °C °F Ordinary Ordinary Intermediate Intermediate High (1) 57 68 79 93 141 135 155 175 200 286 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 – cULus permits use with F1, F2 or FP escutcheons for “light hazard” only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate (1) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6)White Painted Special Application Finishes Sprinkler Escutcheon Cover plate (1) Electroless Nickel PTFE(Teflon®)*(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass(3)Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6)Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. (7) cULus listed Corrosion Resistant Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. *DuPont Registered Trademark • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 04/14 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Superior Coating Dyna-Thread – M-COAT products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products are coated with M-COAT, an advanced MIC coating that is FM approved for use American Made Able to meet “Buy American” requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread – M-COAT pipe is manufactured to meet ASTM A-135, Type E Grade A, is in compliance with NFPA-13 and all sizes are rated at 300 psi working pressure. Dyna-Thread – M-COAT is UL and cUL listed for wet, dry deluge and pre-action sprinkler systems and FM approved for use in wet systems. Dyna-Thread – M-COAT can be hot dip galvanized** to meet FM requirements for use in dry systems. Dyna-Thread – M-COAT is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved and plain end fittings. • Exceptional hydraulics • Lightweight and easy to install • Available factory roll grooved • M-COAT ID • UL and cUL listed • FM approved Combining the safety and longevity of Sch-40 with quality and hydraulic advantages. Dyna-Thread® – M-COAT® pipe is the full line Schedule 40 replacement with the same CRR of Schedule 40, 1.00, providing Dyna-Thread – M-COAT with the same life expectancy as Sch-40. With outstanding hydraulic capabilities, Dyna-Thread – M-COAT is a more widely accepted product substitution than lightwall threadable pipe when Sch-40 is specified. Dyna-Thread – M-COAT’s inside diameter is up to 3.6% larger than Sch-40 and provides improved hydraulics. When used in combination with Dyna-Flow pipe, down sizing of pipe and related components often occurs, thereby reducing costs. The consistent quality of steel used to make Dyna-Thread – M-COAT facilitates smooth threading and lower maintenance costs. Increased strength and lighter weight allows Dyna-Thread – M-COAT to reduce installation fatigue and makes it ideal for retro-fit applications. Dyna-Thread® – M-COAT ® Full Line Schedule 40 Replacement Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 ©2013 Atkore International, Inc. All Rights Reserved. STP-S3-3M-1301 Dyna-Thread – M-COAT NPS Nominal I.D.Wt.Wt. (H20 Filled)CRR CRR In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m Unthreaded Threaded 1”1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 –– 1¼”1.408 1.870 2.54 9.50 1.00 32 35.8 2.8 3.78 –– 1½”1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 4.79 –– 2”2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 –– ** Must be ordered in 10 bundle increments Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE (in) WEIGHT (lbs/ft) I.D. (in) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE (in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail:sales@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-000 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 90° elbow Nominal Size Anvil ItemNumber Universal Number Max. Working Pressure Dimensions- In.(mm)Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840000004 DB90033 500 1.50 1.50 0.6220345038.10 38.10 0.28 11⁄4 840000012 DB90044 500 1.75 1.75 0.90 32 3450 44.45 44.45 0.41 11⁄2 840000020 DB90055 500 1.94 1.94 1.20 40 3450 49.276 49.276 0.54 2 840000038 DB90066 500 2.25 2.25 1.85 50 3450 57.15 57.15 0.84 B A 90° elbow Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 45° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions-Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840002133 DB45033 500 1.12 1.12 0.46 25 3450 28.44 28.44 0.2111⁄4 840002141 DB45044 500 1.29 1.29 0.73 32 3450 32.76 32.76 0.33 11⁄2 840002158 DB45055 500 1.43 1.43 0.9240345036.32 36.32 0.42 2 840002166 DB45066 500 1.68 1.68 1.50 50 3450 42.67 42.67 0.68 A B45° elbow Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-002 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing 90° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 x 1⁄2 840001036 DB90031 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.201 x 3⁄4 840001044 DB90032 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 840001051 DB90041 500 1.34 1.53 0.6432 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 840001069 DB90042 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 840001077 DB90043 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 840001085 DB90053 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 840001093 DB90054 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.492 x 1⁄2 840001101 DB90061 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 840001119 DB90062 500 1.60 1.97 1.2450 x 20 3450 40.64 50.03 0.56 2 x 1 840001127 DB90063 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 840001135 DB90064 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 840001143 DB90065 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 A B reducing 90° elbow Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-003 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. Straight tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840003164 DT333 500 1.50 1.50 0.85 25 3450 38.10 38.10 0.39 11⁄4 840003172 DT444 500 1.75 1.75 1.22 32 3450 44.45 44.45 0.55 11⁄2 840003180 DT555 500 1.94 1.94 1.55 40 3450 49.27 49.27 0.70 2 840003198 DT666 500 2.25 2.25 2.45 50 3450 57.15 57.15 1.11 B AA Straight tee Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-004 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 11⁄2 x 11⁄4 x 1 840004428 DT543 500 1.65 1.58 1.80 1.2540 x 32 x 25 3450 41.91 40.13 45.72 0.5711⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.9040 x 32 x 50 3450 54.86 53.34 51.30 0.8611⁄2 x 11⁄2 x 1⁄2 840004444 DT551 500 1.41 1.41 1.16 1.1540 x 40 x 15 3450 35.81 35.81 29.46 0.5211⁄2 x 11⁄2 x 3⁄4 840004451 DT552 500 1.52 1.52 1.75 1.2440 x 40 x 20 3450 38.61 38.61 44.45 0.5611⁄2 x 11⁄2 x 1 840004469 DT553 500 1.65 1.65 1.80 1.3040 x 40 x 25 3450 41.91 41.91 45.72 0.5911⁄2 x 11⁄2 x 11⁄4 840004477 DT554 500 1.82 1.82 1.88 1.4840 x 40 x 32 3450 46.23 46.23 47.75 0.6711⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.9840 x 40 x 50 3450 54.86 54.86 51.30 0.902 x 1 x 2 840004493 DT636 500 2.25 2.02 2.25 2.1550 x 25 x 50 3450 57.15 51.31 57.15 0.982 x 11⁄4 x 2 840004501 DT646 500 2.25 2.10 2.25 2.3050 x 32 x 50 3450 57.15 53.34 57.15 1.042 x 11⁄2 x 1⁄2 840004519 DT651 500 1.49 1.41 1.88 1.5050 x 40 x 15 3450 37.85 35.81 47.75 0.682 x 11⁄2 x 3⁄4 840004527 DT652 500 1.60 1.52 1.97 1.6250 x 40 x 20 3450 40.64 38.61 50.04 0.732 x 11⁄2 x 1 840004535 DT653 500 1.73 1.65 2.02 1.6450 x 40 x 25 3450 43.94 41.91 51.31 0.742 x 11⁄2 x 11⁄4 840004543 DT654 500 1.90 1.82 2.10 1.8050 x 40 x 32 3450 48.26 46.23 53.34 0.822 x 11⁄2 x 11⁄2 840004550 DT655 500 2.02 1.94 2.16 2.0050 x 40 x 40 3450 51.31 49.28 54.86 0.912 x 11⁄2 x 2 840004568 DT656 500 2.25 2.16 2.25 2.3550 x 40 x 50 3450 57.15 54.86 57.15 1.072 x 2 x 1⁄2 840004576 DT661 500 1.49 1.49 1.88 1.6050 x 50 x 15 3450 37.85 37.85 47.75 0.732 x 2 x 3⁄4 840004584 DT662 500 1.60 1.60 1.97 1.6850 x 50 x 20 3450 40.64 40.64 50.04 0.762 x 2 x 1 840004592 DT663 500 1.73 1.73 2.02 1.8550 x 50 x 25 3450 43.94 43.94 51.31 0.842 x 2 x 11⁄4 840004600 DT664 500 1.90 1.90 2.10 2.0450 x 50 x 32 3450 44.45 42.42 44.45 0.932 x 2 x 11⁄2 840004618 DT665 500 2.02 2.02 2.16 2.1850 x 50 x 40 3450 44.45 42.42 44.45 0.992 x 2 x 21⁄2 -DT667 500 2.60 2.60 2.39 3.6150 x 50 x 65 3450 44.45 42.42 44.45 1.6421⁄2 x 2 x 3⁄4 -DT762 500 1.74 1.60 2.32 2.2865 x 50 x 20 3450 44.45 42.42 44.45 1.03 reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 1 x 1⁄2 x 1 840004196 DT313 500 1.50 1.36 1.50 0.6425 x 15 x 25 3450 38.10 34.54 38.10 0.291 x 3⁄4 x 1 840004204 DT323 500 1.50 1.45 1.50 0.7325 x 20 x 25 3450 38.10 36.83 38.10 0.331 x 1 x 1⁄2 840004212 DT331 500 1.26 1.26 1.36 0.7125 x 25 x 15 3450 32.00 32.00 34.54 0.321 x 1 x 3⁄4 840004220 DT332 500 1.37 1.37 1.45 0.7625 x 25 x 20 3450 34.80 34.80 36.83 0.341 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.9825 x 25 x 32 3450 42.41 42.41 40.13 0.441 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.1625 x 25 x 40 3450 45.72 45.72 41.91 0.5311⁄4 x 1 x 1⁄2 840004253 DT431 500 1.34 1.26 1.53 0.8232 x 25 x 15 3450 34.04 32.00 38.86 0.3711⁄4 x 1 x 3⁄4 840004261 DT432 500 1.45 1.37 1.62 0.9032 x 25 x 20 3450 36.83 34.80 41.15 0.4111⁄4 x 1 x 1 840004279 DT433 500 1.58 1.50 1.67 1.0032 x 25 x 25 3450 40.13 38.10 42.42 0.4511⁄4 x 1 x 11⁄4 840004287 DT434 500 1.75 1.67 1.75 1.0832 x 25 x 32 3450 44.45 42.42 44.45 0.4911⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.4232 x 25 x 40 3450 47.75 45.72 46.22 0.6411⁄4 x 11⁄4 x 1⁄2 840004303 DT441 500 1.34 1.34 1.53 0.8632 x 32 x 15 3450 34.04 34.04 38.86 0.3911⁄4 x 11⁄4 x 3⁄4 840004311 DT442 500 1.45 1.45 1.62 0.9232 x 32 x 20 3450 36.83 36.83 41.15 0.4211⁄4 x 11⁄4 x 1 840004329 DT443 500 1.58 1.58 1.67 0.9532 x 32 x 25 3450 40.13 40.13 42.42 0.4311⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.4532 x 32 x 40 3450 47.75 47.75 46.22 0.6611⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.7532 x 32 x 50 3450 53.34 53.34 48.26 0.7911⁄2 x 1 x 1⁄2 840004352 DT531 500 1.41 1.34 1.66 0.9540 x 25 x 15 3450 35.81 34.04 42.16 0.4311⁄2 x 1 x 3⁄4 840004360 DT532 500 1.52 1.37 1.75 1.1440 x 25 x 20 3450 38.61 34.80 44.45 0.5211⁄2 x 1 x 1 840004378 DT533 500 1.65 1.50 1.80 1.1740 x 25 x 25 3450 41.91 38.10 45.72 0.5311⁄2 x 1 x 11⁄4 840004386 DT534 500 1.82 1.67 1.88 1.3440 x 25 x 32 3450 46.23 42.42 47.75 0.6111⁄2 x 1 x 11⁄2 840004394 DT535 500 1.94 1.80 1.94 1.4540 x 25 x 40 3450 49.28 45.72 49.28 0.6611⁄2 x11⁄4 x 1⁄2 840004402 DT541 500 1.41 1.34 1.66 1.0540 x 32 x 15 3450 35.81 34.04 42.16 0.4811⁄2 x11⁄4 x 3⁄4 840004410 DT542 500 1.52 1.45 1.75 1.1540 x 32 x 20 3450 38.61 36.83 44.45 0.52 C BA reducing tee Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-005 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. bull head tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 1 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.9825 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.45 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 11⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.7911⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.9840 x 40 x 50 3450 54.86 54.86 51.30 0.90 C BA bull head tee Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. capS Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 840005615 DCP003 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 840005623 DCP004 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 840005631 DCP005 500 1.33 0.60 40 3450 33.78 0.272840005649DCP006 500 1.45 0.91 50 3450 36.83 0.41 A cap Ductile Iron FP-4.12 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: The MT-30 mechanical tee serves the same function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space and for easier installation in tight places.The MT-30 is ideal for direct connections with sprinkler heads and drop nipples. The MT-90 is the BSPT equivalent. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE J429 Gr. 2, zinc plated complete with hex flanged lock nuts conforming to ASTM A-563 Gr. A or B of SAE J995 Gr. 2. THREADS: NPT per ANSI/ASME B1.20.1. COATINGS: q Zinc Electroplated q Other available options: Example: RAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000. q Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. FIG. MT-30 Threaded Mechanical Branch Tee For Listings/Approval Details and Limitations,visit our website at www.anvilintl.com orcontact an Anvil® Sales Representative. FP-4.12 MT-30 THREADED MECHANICAL BRANCH TEE Nominal Size O.D.Hole Dimensions Max.WorkingPressures Dimensions Approx.Wt. Ea.Min. Diameter Max. Diameter A B C TTake-out In./DN(mm)In./mm In./mm In./mm PSI/bar In./mm In./mm In./mm In./mm Lbs./Kg 11⁄4 x 1⁄2 1.660 x 0.840 13⁄16 15⁄16 300 21⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 12 42.4 x 21.3 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 3⁄4 1.660 x 1.050 13⁄16 15⁄16 300 21⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 19 42.4 x 26.7 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 1 1.660 x 1.315 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 15⁄8 1.1 32 x 25 42.4 x 33.7 30 33 20.7 58 89 57.2 41 0.5 11⁄2 x 1⁄2 1.900 x 0.840 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 13⁄4 0.8 40 x 12 48.3 x 21.3 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 3⁄4 1.900 x 1.050 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 13⁄4 0.9 40 x 19 48.3 x 26.7 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 1 1.900 x 1.315 13⁄16 15⁄16 300 23⁄8 31⁄2 21⁄4 13⁄4 1.1 40 x 25 48.3 x 33.7 30 33 20.7 61 89 57.2 48 0.5 2 x 1⁄2 2.375 x 0.840 13⁄16 15⁄16 300 21⁄2 33⁄4 21⁄4 2 0.9 50 x 12 60.3 x 21.3 30 33 20.7 64 95 57.2 51 0.4 2 x 3⁄4 2.375 x 1.050 13⁄16 15⁄16 300 21⁄2 33⁄4 21⁄4 2 0.9 50 x 19 60.3 x 26.7 30 33 20.7 64 95 57.2 51 0.4 2 x 1 2.375 x 1.315 13⁄16 15⁄16 300 25⁄8 33⁄4 21⁄4 2 1.1 50 x 25 60.3 x 33.7 30 33 20.7 67 95 57.2 50 0.5 21⁄2 x 1⁄2 2.875 x 0.840 13⁄16 15⁄16 300 23⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 12 73.0 x 21.3 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 3⁄4 2.875 x 1.050 13⁄16 15⁄16 300 23⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 19 73.0 x 26.7 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 1 2.875 x 1.315 13⁄16 15⁄16 300 27⁄8 41⁄4 21⁄4 21⁄4 1.1 65 x 25 73.0 x 33.7 30 33 20.7 73 108 57.2 56 0.5 For dry pipe systems and freezer applications lubrication of the gasket is required,Gruvlok® Xtreme™ Lubricant is required. BSP equivalent is available as a MT-90. s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Note: Tighten nuts alternately to a recommended torque of 18-22 ft.-lbs. (25-30 Nm) on pipe wall less than schedule 10 (Din 2440) or 23-27 ft.-lbs. (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. FIG. MT-30 Threaded Mechanical Branch Tee FP-4.12 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: Mechanical branch connections for reducing branch outlets without welding. The MT-1 is a bolted saddle type fitting with NPT female threaded outlets. Design assures superior sealing, full pipe support, excellent stability and easy installation. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: q Rust inhibiting paint Color: ORANGE (standard) q Hot Dipped Zinc Galvanized (optional) q Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: q Standard Gruvlok q Gruvlok Xtreme™ required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. q Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. FIG. MT-1 Threaded Mechanical Branch Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. VdS FP-4.12 MT-1 THREADED MECHANICAL BRANCH TEE Nominal Size O.D.Hole Dimensions Max.WorkingPressures Dimensions BoltSize Approx.Wt. Ea.Min. Diameter Max. Diameter T VThreaded W Y Z In./DN(mm)In./mm In./mm In./mm PSI/bar In./mm In./mm In./mm In./mm In./mm In./mm Lbs./Kg 2 x 1 2.375 x 1.315 11⁄2 15⁄8 300 115⁄16 25⁄8 19⁄16 45⁄8 21⁄2 3⁄8 x 2 1.750 x 25 60.3 x 33.7 38 41 20.7 50 67 40 117 63 0.8 2 x 11⁄4 2.375 x 1.660 13⁄4 17⁄8 300 115⁄16 25⁄8 19⁄16 45⁄8 21⁄2 3⁄8 x 2 1.750 x 32 60.3 x 42.4 44 48 20.7 49 67 40 117 63 0.82 x 11⁄2 2.375 x 1.900 13⁄4 17⁄8 300 115⁄16 25⁄8 19⁄16 45⁄8 27⁄8 3⁄8 x 2 1.750 x 40 60.3 x 48.3 44 48 20.7 49 67 40 117 73 0.821⁄2 x 1 2.875 x 1.315 11⁄2 15⁄8 300 27⁄16 31⁄8 113⁄16 59⁄16 33⁄8 1⁄2 x 23⁄4 3.665 x 25 73.0 x 33.7 38 41 20.7 62 79 46 141 86 1.6 21⁄2 x 11⁄4 2.875 x 1.660 2 21⁄8 300 27⁄16 31⁄8 113⁄16 59⁄16 33⁄8 1⁄2 x 23⁄4 3.665 x 32 73.0 x 42.4 51 54 20.7 62 79 46 141 86 1.621⁄2 x 11⁄2 2.875 x 1.900 2 21⁄8 300 27⁄16 31⁄8 113⁄16 59⁄16 33⁄8 1⁄2 x 23⁄4 3.665 x 40 73.0 x 48.3 51 54 20.7 62 79 46 141 86 1.63 x 1 3.500 x 1.315 11⁄2 15⁄8 300 23⁄4 37⁄16 21⁄8 61⁄4 315⁄16 1⁄2 x 23⁄4 3.880 x 25 88.9 x 33.7 38 41 20.7 71 87 55 159 99 1.73 x 11⁄4 3.500 x 1.660 2 21⁄8 300 23⁄4 37⁄16 21⁄8 61⁄4 315⁄16 1⁄2 x 23⁄4 3.880 x 32 88.9 x 42.4 51 54 20.7 70 87 55 159 99 1.7 3 x 11⁄2 3.500 x 1.900 2 21⁄8 300 23⁄4 37⁄16 21⁄8 61⁄4 315⁄16 1⁄2 x 23⁄4 3.880 x 40 88.9 x 48.3 51 54 20.7 70 87 55 159 99 1.73 x 2 3.500 x 2.375 21⁄2 25⁄8 300 23⁄4 37⁄16 21⁄8 61⁄4 315⁄16 1⁄2 x 23⁄4 4.480 x 50 88.9 x 60.3 64 67 20.7 70 87 55 159 99 2.04 x 1 4.500 x 1.315 11⁄2 15⁄8 300 35⁄16 4 25⁄8 71⁄4 313⁄16 1⁄2 x 23⁄4 4.6100 x 25 114.3 x 33.7 38 41 20.7 85 102 67 184 97 2.1 4 x 11⁄4 4.500 x 1.660 2 21⁄8 300 35⁄16 4 25⁄8 71⁄4 313⁄16 1⁄2 x 23⁄4 4.6100 x 32 114.3 x 42.4 51 54 20.7 84 102 67 184 97 2.14 x 11⁄2 4.500 x 1.900 2 21⁄8 300 35⁄16 4 25⁄8 71⁄4 313⁄16 1⁄2 x 23⁄4 4.6100 x 40 114.3 x 48.3 51 54 20.7 84 102 67 184 97 2.14 x 2 4.500 x 2.375 21⁄2 25⁄8 300 35⁄16 4 25⁄8 71⁄4 41⁄2 1⁄2 x 23⁄4 4.8100 x 50 114.3 x 60.3 64 67 20.7 84 102 67 184 115 2.24 x 21⁄2 4.500 x 2.875 23⁄4 27⁄8 300 31⁄16 4 25⁄8 71⁄4 41⁄2 1⁄2 x 23⁄4 5.4100 x 65 114.3 x 73.0 70 73 20.7 78 102 67 184 115 2.4 4 x 3 4.500 x 3.500 31⁄2 35⁄8 300 3 41⁄8 25⁄8 71⁄4 51⁄8 1⁄2 x 23⁄4 5.4100 x 80 114.3 x 88.9 89 92 20.7 76 105 67 184 130 2.45 x 11⁄2 5.563 x 1.900 2 21⁄8 300 41⁄16 43⁄4 33⁄16 85⁄16 313⁄16 5⁄8 x 4 7.4125 x 40 141.3 x 48.3 51 54 20.7 103 121 81 211 97 3.45 x 2 5.563 x 2.375 21⁄2 25⁄8 300 41⁄16 43⁄4 33⁄16 85⁄16 313⁄16 5⁄8 x 4 7.9125 x 50 141.3 x 60.3 64 67 20.7 103 121 81 211 97 3.6 5 x 21⁄2 5.563 x 2.875 23⁄4 27⁄8 300 313⁄16 43⁄4 33⁄16 85⁄16 313⁄16 5⁄8 x 4 7.9125 x 65 141.3 x 73.0 70 73 20.7 97 121 81 211 97 3.66 x 11⁄4 6.625 x 1.660 2 21⁄8 300 313⁄16 415⁄16 311⁄16 93⁄8 37⁄8 5⁄8 x 4 8.0150 x 32 168.3 x 42.2 51 54 20.7 97 126 94 238 98 3.66 x 11⁄2 6.625 x 1.900 2 21⁄8 300 47⁄16 51⁄8 311⁄16 93⁄8 37⁄8 5⁄8 x 4 7.5150 x 40 168.3 x 48.3 51 54 20.7 113 130 94 238 98 3.46 x 2 6.625 x 2.375 21⁄2 25⁄8 300 47⁄16 51⁄8 311⁄16 93⁄8 47⁄16 5⁄8 x 4 8.0150 x 50 168.3 x 60.3 64 67 20.7 112 130 94 238 112 3.6 6 x 21⁄2 6.625 x 2.875 23⁄4 27⁄8 300 43⁄16 51⁄8 311⁄16 93⁄8 47⁄16 5⁄8 x 4 8.0150 x 65 168.3 x 73.0 70 73 20.7 106 130 94 238 112 3.66 x 3 6.625 x 3.500 31⁄2 35⁄8 300 41⁄8 51⁄4 311⁄16 93⁄8 55⁄8 5⁄8 x 4 9.7150 x 80 168.3 x 88.9 89 92 20.7 105 133 94 238 143 4.48 x 2 8.625 x 2.375 21⁄2 25⁄8 300 57⁄16 61⁄4 47⁄8 105⁄16 47⁄16 3⁄4 x 41⁄4 10.2200 x 50 219.1 x 60.3 64 67 20.7 138 159 123 313 112 4.6 For dry pipe systems and freezer applications lubrication of the gasket is required,Gruvlok® Xtreme™ Lubricant is required. All sizes may be used as mechanical crosses. Threads are NPT per ANSI/ASME B1.20.1 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. FIG. MT-1 Threaded Mechanical Branch Tee OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 90 www.tolco.com Revision 3/1/2007 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330 Customer Service •800.786.5266 www.tolco.com 72 www.tolco.com Revision 5/24/2001 ™ ®a brand of Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 62 www.tolco.com Revision 1/24/2007 Size Range — 3/8" thru 3/4" rod Function — For attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. Fig. 68 - Wide Throat Top Beam “C” Clamp w/Locknut Dimensions • Weights Rod Max. Rec. Approx. Size Load Lbs. Wt./100 3/8 400 34 1/2 500 50 5/8 600 53 3/4 800 86 Visit Hilti Online US www.us.hilti.com Canada www.ca.hilti.com Listings/Approvals ICC-ES (International Code Council) Evaluation Report No. 5264 COLA (City of Los Angeles) Research Report No.25350 FM (Factory Mutual) 4.3.7.4 Installation Instructions 4.3.7.5 Ordering Information 4.3.7.3 Technical Data Average Ultimate Loads, lb (kN)Allowable Loads, lb (kN) 4000 psi Concrete Hollow Core 4000 psi Concrete Hollow Core Length Bit Size 1 (27.6 MPa) (Spancrete) (27.6 MPa) (Spancrete) Desc. in.(mm)in. Tension Shear Tension Shear Tension Shear Tension Shear HDI-P 3/8 3/4 (19.1) 1/2 1900(8.5)3000(13.3)2100 (9.3)4000 (17.8)380 (1.7)600 (2.7)420(1.9)800 (3.6) 1. Set depth gauge on drill. 2. Hammer-drill hole. 3. Clean hole. 4. Insert anchor. 5. Insert setting tool and strike with hammer until anchor is fully set. 6. Collar of setting tool will leave an indentation on flange of anchor when properly expanded. HDI-P Anchor Item No. Description Box Qty 00283611 HDI-P 3/8 100 Setting Tools for HDI-P Anchors Item No.Description 00283611 HSD-G 3/8" – 3/4" Setting Tool w/ hand guard 00253784 HST-P 3/8" – 3/4" Setting Tool 1 For Hilti matched tolerance carbide tipped drill bits, see section 8.4.1. The Hilti HDI-P Drop-In anchor is an internally threaded, flush mounted expansion anchor for solid and hollow concrete. Product Features • Optimized 3/4" anchor length to allow reliable fastenings in hollow core panels,precast plank & post tensioned slabs • Shallow drilling enables fast installation • Lip provides flush installation, consistent anchor depth and easy rod alignment • Setting tool leaves mark on flange when anchor is set properly to enable inspection & verification of proper expansion Guide Specifications Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1,Type III. Anchors shall be Hilti HDI-P anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits.Install anchors in accordance with manufacturer’s recommendations. 4.3.7.2 Material Specifications The HDI-P is manufactured from mild carbon steel, which is zinc plated for corrosion protection in accordance with ASTM B 633, SC 1,Type III HDI-P Drop-In Anchor 4.3.7 Mechanical Anchoring Systems 185Hilti,Inc.(US)1-800-879-8000 I Product Technical Guide 2004 I Hilti (Canada) Corporation 1-800-363-4458 4.3.7 HDI-P 4.3.7.1 Product Description 4.3.7.2 Material Specifications 4.3.7.3 Technical Data 4.3.7.4 Installation Instructions 4.3.7.5 Ordering Information 4.3.7.1 Product Description HDI-P Specification Table