Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutF14-0028 calcs.pdfDesign
Remote Area Name
Remote Area Location
Occupancy Classification
Density (gpm/ft²)
Area of Application (ft²)
Coverage per Sprinkler (ft²)
Number of Calculated Sprinklers
In-Rack Demand (gpm)
Special Heads
Hose Streams (gpm)
Total Water Required (incl. Hose Streams) (gpm)
Required Pressure at Source (psi)
Type of System
Volume - Entire System (gal)
1
Main Floor
R3
0.101
792
198
4
0
100
180.6
83.4
Wet
112.7 gal
Water Supply Information
Date
Location
Source
HYDRAULIC CALCULATIONS
for
JUNE 17, 2014
JUNIPER LANE
SRC
4 Head Calc
Project Name : Cummings Residence
Contract No. : 14-679
Project Location: 4936 Juniper Lane
City: Vail, Colorado
Date: 7/24/2014
Name of Contractor: Meridian Fire Intermountain
Address: 331 Metcalf Road Bldg B Unit 9
Phone Number: 970-827-9120
Name of Designer: VFE / BAE
Authority Having Jurisdiction: VF&ES
City: Avon, Colorado 81620
E-mail: info@vailelectronics.com
Job Information
Contractor Information
Notes
Date 7/24/2014 Page 1Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceDiagram for Design Area : 1(Optimized Hydraulic Simplified)Node Labels:Pipe Labels:OffOffDate 7/24/2014Page 2Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 1
Water Supply Parameters
Calculation Info
Calculation Mode
Hydraulic ModelFluid Name
Fluid Weight, (lb/ft³)Fluid Dynamic Viscosity, (lb·s/ft²)
Demand
Hazen-WilliamsWater @ 60F (15.6C)
N/A for Hazen-Williams calculation.N/A for Hazen-Williams calculation.
Supply 1 : SRC Flow (gpm)Pressure (psi)
0 89.1
1258 41.3
Inside Hose Flow / Standpipe Demand (gpm)
Outside Hose Flow (gpm)
Additional Outside Hose Flow (gpm)
Other (custom defined) Hose Flow (gpm)
Total Hose Flow (gpm)
100
100
Hoses
Ovehead Sprinkler Flow (gpm)
InRack Sprinkler Flow (gpm)
Other (custom defined) Sprinkler Flow (gpm)
Total Sprinkler Flow (gpm)
80.6
0
0
80.6
Required Margin of Safety (psi)
SRC - Pressure (psi)
SRC - Flow (gpm)
Demand w/o System Pump(s)
0
83.4
80.6
N/A
Sprinklers
Other
Date 7/24/2014 Page 3Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceHydraulic Analysis for : 1SupplySystem DemandAdd. Out. HoseFlow, gpmPressure, psi1009080706050403020100S1S230.866D1D2D2D30 400 500 600 700 800 900 1000 1100 1200 1300 1400Date 7/24/2014Page 4Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 1
Pressure (psi)Label
Graph Labels
Flow (gpm)
ValuesDescription
0S1 89.1Supply point #1 - Static
1258S2 41.3Supply point #2 - Residual
0D1 20.2Elevation Pressure
80.6D2 83.4System Demand
180.6D3 83.4System Demand + Add.Out.Hose
Pressure (psi)Curve Name
Curve Intersections & Safety Margins
Flow (gpm)
Safety MarginIntersection
Pressure (psi)@ Flow (gpm)
84.2Supply88.8 4.3 180.6
Open Heads
Head Ref.DensityDensityK-Factor PressureFlowPressure
(gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi)
Flow
(gpm)
Coverage
(ft²)
Required CalculatedHead Type
S101 4.9 0.1 19.8 16.7 0.101 16.720198Overhead
Sprinkler
S102 4.9 0.1 19.8 16.7 0.101 16.720198OverheadSprinkler
S103 4.9 0.1 19.8 16.7 0.102 1720.2198OverheadSprinkler
S104 4.9 0.1 19.8 16.7 0.103 17.320.4198Overhead
Sprinkler
Date 7/24/2014 Page 5Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
S101Overhead Sprinkler HEAD 4.90 34.58198 37.05143.06
S102Overhead Sprinkler HEAD 4.90 34.58198 29.2150.91
S103Overhead Sprinkler HEAD 4.90 34.58198 21.02145.31
S104Overhead Sprinkler HEAD 4.90 34.58198 28.93137.51
001Node NODERP.TEE 0 35.28 28.65137.22
003Node NODERP.TEE 0 32.25 21.63136.68
005Node NODERP.90 0 19.83 21.14137.16
009Node NODERP.TEE 0 19.83 29.98148.25
011Node NODERP.TEE 0 19.83 22.13156.09
012Node NODERP.TEE 0 19.83 21.84156.38
024Node NODERP.TEE 0 19.83 0.53171.05
025Node NODERP.TEE 0 19.83 -0.45171.05
026Node NODERP.TEE 0 19.83 -0.45166.57
029Node NODERP.TEE 0 31 -1.92164.03
034Node NODERP.TEE 0 31 -18162.81
035Node NODERP.TEE 0 31 -20.27160.55
039Node NODERP.TEE 0 19.83 -33.66154.55
041Node NODERP.TEE 0 9.5 -34.41155.29
042Node NODERP.TEE 0 9.5 -35.23154.47
051Node NODEus.90 0 -6 -62.95156.04
056-INode NODEcoupling 0 -6 -55.094.66
056-ONode NODEcoupling 0 -6 -55.095.16
093Node NODERP.TEE 0 19.83 -44.41163.66
120Node NODERP.TEE 0 19.83 -19.23171.85
162Node NODERP.90 0 19.83 25.01165.52
Date 7/24/2014 Page 6Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
177Node NODERP.TEE 0 9.5 -2.79155.75
179Node NODERP.TEE 0 9.5 3.16157.56
219Node NODERP.TEE 0 19.83 -5149.39
261Node NODERP.TEE 0 31 7.08155.02
311Node NODERP.90 0 19.83 36.96150.62
315Node NODERP.TEE 0 35 33.58146.53
316Node NODERP.TEE 0 35 29.2150.91
318Node NODERP.TEE 0 35 37.05143.06
336Node NODERP.TEE 0 35 21.02145.31
BFP-INode NODEcoupling 0 -6 -63.87155.12
BFP-ONode NODEcoupling 0 -6 -63.52155.47
PRV-INode NODEcoupling 0 -6 -64.58154.41
RM-INode NODEcoupling 0 -2.39 -62.95156.04
RM-ONode NODEcoupling 0 -1.3 -62.95156.04
SRCSupply SUPPLY 0 -6 -56.093.26
Date 7/24/2014 Page 7Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
S102
316
34.58
35
4.9 20
20
1
0.91
1x(RP.TEE-Br)=6.3 0.42
6.3
6.72
150
0.1718
16.7
-0.2
1.2
316
315
35
35
0
20
1.5
1.43
1x(RP.TEE-Br)=9.9 6.19
9.9
16.09
150
0.019
17.6
0
0.3
315
311
35
19.83
20
40.1
1.5
1.43
3x(RP.90)=12.3
1x(RP.TEE-Br)=9.9
18.74
22.2
40.94
150
0.0687
18
6.6
2.8
311
009
19.83
19.83
0
40.1
2
1.8
2x(RP.TEE-Run)=3.4
2x(RP.TEE-Br)=28.8
9.87
32.2
42.07
150
0.0224
28.3
0
0.9
009
011
19.83
19.83
40.5
80.6
2
1.8
2x(RP.TEE-Run)=3.4 11.09
3.4
14.49
150
0.0817
29.3
0
1.2
011
012
19.83
19.83
-18
62.6
2
1.8
1x(RP.TEE-Run)=1.7 0.41
1.7
2.11
150
0.0512
30.4
0
0.1
012
024
19.83
19.83
-25.3
37.4
2
1.8
9x(RP.TEE-Run)=15.3
1x(RP.45)=2.8
2x(RP.90)=10.4
29.71
28.5
58.21
150
0.0197
30.6
0
1.1
024
025
19.83
19.83
-8.8
28.5
2
1.8
1x(RP.TEE-Br)=14.4 0.97
14.4
15.37
150
0.0119
31.7
0
0.2
025
120
19.83
19.83
-9.2
19.3
2
1.8
3x(RP.TEE-Run)=5.1
1x(RP.90)=5.2
19.26
10.3
29.56
150
0.0058
31.9
0
0.2
120
093
19.83
19.83
-4.8
14.5
2
1.8
5x(RP.TEE-Run)=8.5
2x(RP.TEE-Br)=28.8
5x(RP.45)=14
32.32
51.3
83.62
150
0.0034
32.1
0
0.3
093
042
19.83
9.5
9.4
23.8
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
23.32
19.6
42.92
150
0.0085
32.3
4.5
0.4
042
RM-O
9.5
-1.3
56.8
80.6
2
1.8
1x(coupling)=0.77
4x(RP.90)=20.8
3x(RP.TEE-Run)=5.1
50.01
26.67
76.68
150
0.0817
37.9
4.7
6.3
RM-O
RM-I
-1.3
-2.39
0
80.6
2
0
1.08
0
1.08
0
0.1488
49.5
0.5
0.2
Riser Manifold
***
RM-I
051
-2.39
-6
0
80.6
2
1.8
1x(us.90)=3.85 3.61
3.85
7.46
150
0.0817
50.2
1.6
0.6
051
BFP-O
-6
-6
0
80.6
2
2.067
1x(coupling)=1.51 0.8
1.51
2.31
150
0.0417
52.6
0
0.1
BFP-O
BFP-I
-6
-6
0
80.6
2
0
0.5
0
0.5
0
28.155
52.7
0
14.1
Wilkins975xlrp
***
Date 7/24/2014 Page 8Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
BFP-I
PRV-I
-6
-6
0
80.6
2
0
1
0
1
0
8.5717
66.8
0
8.6
Wilkins 500xl
***
PRV-I
056-O
-6
-6
0
80.6
2
2.067
1x(coupling)=1.51
1x(us.45)=3.02
1x(us.90)=7.55
163.66
12.08
175.74
150
0.0417
75.4
0
7.3
056-O
056-I
-6
-6
0
80.6
2
0
0.5
0
0.5
0
0.0386
82.7
0
0.0
GATE VALVE
***
056-I
SRC
-6
-6
0
80.6
2
2.067
1x(us.Tee-Br)=15.1 2.4
15.1
17.5
150
0.0417
82.7
0
0.7
SRC 83.4
2Path No:
S101
318
34.58
35
4.9 20
20
1
0.91
1x(RP.TEE-Br)=6.3 0.42
6.3
6.72
150
0.172
16.7
-0.2
1.2
318
315
35
35
0
20
1.5
1.43
1x(RP.TEE-Br)=9.9 4.91
9.9
14.81
150
0.019
17.7
0
0.3
315 18
3Path No:
S103
336
34.58
35
4.9 20.2
20.2
1
0.91
1x(RP.TEE-Br)=6.3 0.42
6.3
6.72
150
0.1745
17
-0.2
1.2
336
003
35
32.25
0
20.2
1.5
1.43
1x(RP.TEE-Br)=9.9
3x(RP.90)=12.3
12.89
22.2
35.09
150
0.0193
17.9
1.2
0.7
003
005
32.25
19.83
20.4
40.5
1.5
1.43
1x(RP.90)=4.1
1x(RP.TEE-Br)=9.9
13.1
14
27.1
150
0.0702
20
5.4
1.9
005
009
19.83
19.83
0
40.5
2
1.8
1x(RP.TEE-Run)=1.7
2x(RP.TEE-Br)=28.8
1x(RP.90)=5.2
15.67
35.7
51.37
150
0.0229
28.1
0
1.2
009 29.3
4Path No:
S104
001
34.58
35.28
4.9 20.4
20.4
1
0.91
1x(RP.TEE-Br)=6.3 0.81
6.3
7.11
150
0.1771
17.3
-0.3
1.3
001
003
35.28
32.25
0
20.4
1.5
1.43
1x(RP.TEE-Run)=1.4
1x(RP.90)=4.1
10.73
5.5
16.23
150
0.0196
18.2
1.3
0.3
003 20
Date 7/24/2014 Page 9Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
5Path No:
011
162
19.83
19.83
0
18
2
1.8
1x(RP.90)=5.2
2x(RP.TEE-Br)=28.8
13.04
34
47.04
150
0.0051
30.4
0
0.2
162
261
19.83
31
0
18
1.5
1.43
3x(RP.TEE-Run)=4.2
3x(RP.TEE-Br)=29.7
36.51
33.9
70.41
150
0.0156
30.7
-4.8
1.1
261
029
31
31
0
18
2
1.8
5x(RP.TEE-Run)=8.5 12.73
8.5
21.23
150
0.0051
26.2
0
0.1
029
034
31
31
-1.2
16.8
2
1.8
2x(RP.TEE-Run)=3.4
1x(RP.TEE-Br)=14.4
2x(RP.45)=5.6
18.86
23.4
42.26
150
0.0045
26.3
0
0.2
034
035
31
31
4.8
21.7
2
1.8
1x(RP.TEE-Run)=1.7 3.2
1.7
4.9
150
0.0072
26.5
0
0.0
035
039
31
19.83
-9.4
12.3
2
1.8
2x(RP.TEE-Run)=3.4
2x(RP.90)=10.4
30.11
13.8
43.91
150
0.0025
26.6
4.8
0.1
039
041
19.83
9.5
15.6
27.9
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
11.38
19.6
30.98
150
0.0115
32.2
4.5
0.4
041
042
9.5
9.5
28.9
56.8
2
1.8
1x(RP.TEE-Run)=1.7 1.16
1.7
2.86
150
0.0427
37.7
0
0.1
042 37.9
6Path No:
012
179
19.83
9.5
0
25.3
2
1.8
2x(RP.TEE-Run)=3.4
5x(RP.TEE-Br)=72
2x(RP.90)=10.4
45.68
85.8
131.48
150
0.0095
30.6
4.5
1.3
179
177
9.5
9.5
8.8
34.1
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.45)=2.8
6.7
4.5
11.2
150
0.0166
37
0
0.2
177
041
9.5
9.5
-5.3
28.9
2
1.8
8x(RP.TEE-Run)=13.6
1x(RP.45)=2.8
31.8
16.4
48.2
150
0.0122
37.1
0
0.6
041 37.7
7Path No:
024
179
19.83
9.5
0
8.8
2
1.8
2x(RP.TEE-Run)=3.4
6x(RP.90)=31.2
1x(RP.TEE-Br)=14.4
30.7
49
79.7
150
0.0014
31.7
4.5
0.1
179 37
Date 7/24/2014 Page 10Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
8Path No:
025
026
19.83
19.83
0
9.2
2
1.8
1x(RP.TEE-Run)=1.7 4.48
1.7
6.18
150
0.0015
31.9
0
0
026
219
19.83
19.83
1.2
10.4
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.45)=5.6
2x(RP.90)=10.4
24.21
44.8
69.01
150
0.0018
31.9
0
0.1
219
039
19.83
19.83
5.3
15.6
2
1.8
3x(RP.TEE-Run)=5.1
1x(RP.TEE-Br)=14.4
1x(RP.45)=2.8
30.81
22.3
53.11
150
0.0039
32
0
0.2
039 32.2
9Path No:
120
034
19.83
31
0
4.8
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.90)=10.4
20.4
39.2
59.6
150
0.0004
32.1
-4.8
0.0
034 26.5
10Path No:
029
026
31
19.83
0
1.2
2
1.8
1x(RP.TEE-Br)=14.4
2x(RP.90)=10.4
15.18
24.8
39.98
150
0.0000
26.3
4.8
0
026 31.9
11Path No:
035
093
31
19.83
0
9.4
2
1.8
5x(RP.TEE-Run)=8.5
6x(RP.TEE-Br)=86.4
51.45
94.9
146.35
150
0.0015
26.6
4.8
0.2
093 32.3
12Path No:
177
219
9.5
19.83
0
5.3
2
1.8
1x(RP.TEE-Run)=1.7
2x(RP.90)=10.4
1x(RP.TEE-Br)=14.4
18.89
26.5
45.39
150
0.0005
37.1
-4.5
0.0
219 32
* Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding.
*** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with
this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The frictionloss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values
are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is basedsolely on the curve data.
* Maximum Velocity of 10.16 ft/s occurs in the following pipe(s): (011-009), (RM-O-042), (051-RM-I)
Date 7/24/2014 Page 11Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure vs. Flow Function
Design Area: 1; Supply Ref.: SRC; Supply Name:SRC
Flow, gpm0200300400500600700800900 10001258Pressure, psi100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
87.8 psi @ 180.6 gpm (80.6 gpm+100 gpm add. out. hose)
Pressure Loss Function
Design Area: 1; BFP Ref.: 451 (Wilkins975xlrp, Size = 2); Inlet Node: BFP-I; Outlet Node: BFP-O
Flow, gpm050 100150200225Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
14.1 psi @ 80.6 gpm
Date 7/24/2014 Page 12Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 1; Valve Ref.: 449 (Riser Manifold, Size = 2); Inlet Node: RM-I; Outlet Node: RM-O
Flow, gpm100200 300400500Pressure, psi0.6
0.1
Pressure Loss Function
Design Area: 1; Valve Ref.: 450 (Wilkins 500xl, Size = 2); Inlet Node: PRV-I; Outlet Node: BFP-I
Flow, gpm02550 75100125150160Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8.6 psi @ 80.6 gpm
Date 7/24/2014 Page 13Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 1; Valve Ref.: 452 (GATE VALVE, Size = 2); Inlet Node: 056-I; Outlet Node: 056-O
Flow, gpm150200250.6300360Pressure, psi0.23
0.13
0.03
Date 7/24/2014 Page 14Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Design
Remote Area Name
Remote Area Location
Occupancy Classification
Density (gpm/ft²)
Area of Application (ft²)
Coverage per Sprinkler (ft²)
Number of Calculated Sprinklers
In-Rack Demand (gpm)
Special Heads
Hose Streams (gpm)
Total Water Required (incl. Hose Streams) (gpm)
Required Pressure at Source (psi)
Type of System
Volume - Entire System (gal)
2
BASEMENT GARAGE
R3
0.1
896
224
4
0
100
191.6
80.8
Wet
107.2 gal
Water Supply Information
Date
Location
Source
HYDRAULIC CALCULATIONS
for
JUNE 17, 2014
JUNIPER LANE
SRC
4 HEAD CALC @ .10
Project Name : Cummings Residence
Contract No. : 14-679
Project Location: 4936 Juniper Lane
City: Vail, Colorado
Date: 7/24/2014
Name of Contractor: Meridian Fire Intermountain
Address: 331 Metcalf Road Bldg B Unit 9
Phone Number: 970-827-9120
Name of Designer: VFE / BAE
Authority Having Jurisdiction: VF&ES
City: Avon, Colorado 81620
E-mail: info@vailelectronics.com
Job Information
Contractor Information
Notes
Date 7/24/2014 Page 15Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceDiagram for Design Area : 2(Optimized Hydraulic Simplified)Node Labels:Pipe Labels:OffOffDate 7/24/2014Page 16Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 2
Water Supply Parameters
Calculation Info
Calculation Mode
Hydraulic ModelFluid Name
Fluid Weight, (lb/ft³)Fluid Dynamic Viscosity, (lb·s/ft²)
Demand
Hazen-WilliamsWater @ 60F (15.6C)
N/A for Hazen-Williams calculation.N/A for Hazen-Williams calculation.
Supply 1 : SRC Flow (gpm)Pressure (psi)
0 89.1
1258 41.3
Inside Hose Flow / Standpipe Demand (gpm)
Outside Hose Flow (gpm)
Additional Outside Hose Flow (gpm)
Other (custom defined) Hose Flow (gpm)
Total Hose Flow (gpm)
100
100
Hoses
Ovehead Sprinkler Flow (gpm)
InRack Sprinkler Flow (gpm)
Other (custom defined) Sprinkler Flow (gpm)
Total Sprinkler Flow (gpm)
91.6
0
0
91.6
Required Margin of Safety (psi)
SRC - Pressure (psi)
SRC - Flow (gpm)
Demand w/o System Pump(s)
0
80.8
91.6
N/A
Sprinklers
Other
Date 7/24/2014 Page 17Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceHydraulic Analysis for : 2SupplySystem DemandAdd. Out. HoseFlow, gpmPressure, psi1009080706050403020100S1S230.866D1D2D2D30 400 500 600 700 800 900 1000 1100 1200 1300 1400Date 7/24/2014Page 18Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 2
Pressure (psi)Label
Graph Labels
Flow (gpm)
ValuesDescription
0S1 89.1Supply point #1 - Static
1258S2 41.3Supply point #2 - Residual
0D1 7Elevation Pressure
91.6D2 80.8System Demand
191.6D3 80.8System Demand + Add.Out.Hose
Pressure (psi)Curve Name
Curve Intersections & Safety Margins
Flow (gpm)
Safety MarginIntersection
Pressure (psi)@ Flow (gpm)
96.8Supply88.7 6.9 191.6
Open Heads
Head Ref.DensityDensityK-Factor PressureFlowPressure
(gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi)
Flow
(gpm)
Coverage
(ft²)
Required CalculatedHead Type
s201 4.9 0.1 22.4 21 0.1 2122.5224Overhead
Sprinkler
s202 4.9 0.1 22.4 21 0.103 22.123.1224OverheadSprinkler
s203 4.9 0.1 22.4 21 0.102 21.522.7224OverheadSprinkler
s204 4.9 0.1 22.4 21 0.104 22.723.3224Overhead
Sprinkler
Date 7/24/2014 Page 19Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
012Node NODERP.TEE 0 19.83 21.84156.38
024Node NODERP.TEE 0 19.83 0.53171.05
025Node NODERP.TEE 0 19.83 -0.45171.05
026Node NODERP.TEE 0 19.83 -0.45166.57
029Node NODERP.TEE 0 31 -1.92164.03
034Node NODERP.TEE 0 31 -18162.81
035Node NODERP.TEE 0 31 -20.27160.55
039Node NODERP.TEE 0 19.83 -33.66154.55
041Node NODERP.TEE 0 9.5 -34.41155.29
042Node NODERP.TEE 0 9.5 -35.23154.47
051Node NODEus.90 0 -6 -62.95156.04
056-INode NODEcoupling 0 -6 -55.094.66
056-ONode NODEcoupling 0 -6 -55.095.16
093Node NODERP.TEE 0 19.83 -44.41163.66
120Node NODERP.TEE 0 19.83 -19.23171.85
162Node NODERP.90 0 19.83 25.01165.52
170Node NODERP.TEE 0 9.5 -32.64155.75
171Node NODERP.TEE 0 9.5 -24.86155.75
177Node NODERP.TEE 0 9.5 -2.79155.75
179Node NODERP.TEE 0 9.5 3.16157.56
219Node NODERP.TEE 0 19.83 -5149.39
242Node NODERP.TEE 0 9.5 -25.33167.82
243Node NODERP.TEE 0 9.5 -36.65179.14
244Node NODERP.TEE 0 9.5 -47.96190.45
247Node NODERP.TEE 0 9.5 -33.11160.05
Date 7/24/2014 Page 20Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
248Node NODERP.TEE 0 9.5 -44.43171.36
249Node NODERP.TEE 0 9.5 -55.74182.67
261Node NODERP.TEE 0 31 7.08155.02
BFP-INode NODEcoupling 0 -6 -63.87155.12
BFP-ONode NODEcoupling 0 -6 -63.52155.47
PRV-INode NODEcoupling 0 -6 -64.58154.41
RM-INode NODEcoupling 0 -2.39 -62.95156.04
RM-ONode NODEcoupling 0 -1.3 -62.95156.04
SRCSupply SUPPLY 0 -6 -56.093.26
s201Overhead Sprinkler HEAD 4.90 8224 -47.96190.45
s202Overhead Sprinkler HEAD 4.90 8224 -36.65179.14
s203Overhead Sprinkler HEAD 4.90 8224 -55.74182.67
s204Overhead Sprinkler HEAD 4.90 8224 -44.43171.36
Date 7/24/2014 Page 21Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
s201
244
8
9.5
4.9 22.5
22.5
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2124
21
-0.6
1.7
244
243
9.5
9.5
0
22.5
1.25
1.14
1x(RP.TEE-Run)=1.1 16
1.1
17.1
150
0.0709
21.9
0
1.2
243
242
9.5
9.5
23.1
45.5
1.25
1.14
1x(RP.TEE-Run)=1.1 16
1.1
17.1
150
0.2622
23.1
0
4.5
242
171
9.5
9.5
0
45.5
1.5
1.43
1x(RP.TEE-Br)=9.9
1x(RP.45)=2.2
12.27
12.1
24.37
150
0.0869
27.6
0
2.1
171
177
9.5
9.5
-22.3
23.2
2
1.8
6x(RP.TEE-Run)=10.2 22.07
10.2
32.27
150
0.0081
29.7
0
0.3
177
179
9.5
9.5
-11.4
11.8
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.45)=2.8
6.7
4.5
11.2
150
0.0023
30
0
0.0
179
024
9.5
19.83
-4.9
6.9
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.TEE-Run)=1.7
6x(RP.90)=31.2
30.7
47.3
78
150
0.0009
30
-4.5
0.1
024
025
19.83
19.83
2.3
9.2
2
1.8
1x(RP.TEE-Br)=14.4 0.97
14.4
15.37
150
0.0015
24.9
0
0.0
025
120
19.83
19.83
-0.3
8.9
2
1.8
3x(RP.TEE-Run)=5.1
1x(RP.90)=5.2
19.26
10.3
29.56
150
0.0014
25
0
0.0
120
093
19.83
19.83
-0.4
8.5
2
1.8
5x(RP.TEE-Run)=8.5
2x(RP.TEE-Br)=28.8
5x(RP.45)=14
32.32
51.3
83.62
150
0.0013
25
0
0.1
093
042
19.83
9.5
6.2
14.7
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
23.32
19.6
42.92
150
0.0035
25.1
4.5
0.2
042
RM-O
9.5
-1.3
76.9
91.6
2
1.8
1x(coupling)=0.77
4x(RP.90)=20.8
3x(RP.TEE-Run)=5.1
50.01
26.67
76.68
150
0.1036
30.4
4.7
7.9
RM-O
RM-I
-1.3
-2.39
0
91.6
2
0
1.08
0
1.08
0
0.1691
43.7
0.5
0.2
Riser Manifold
***
RM-I
051
-2.39
-6
0
91.6
2
1.8
1x(us.90)=3.85 3.61
3.85
7.46
150
0.1036
44.4
1.6
0.8
051
BFP-O
-6
-6
0
91.6
2
2.067
1x(coupling)=1.51 0.8
1.51
2.31
150
0.0528
47
0
0.1
BFP-O
BFP-I
-6
-6
0
91.6
2
0
0.5
0
0.5
0
27.483
47.1
0
13.7
Wilkins975xlrp
***
Date 7/24/2014 Page 22Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
BFP-I
PRV-I
-6
-6
0
91.6
2
0
1
0
1
0
9.6498
60.9
0
9.6
Wilkins 500xl
***
PRV-I
056-O
-6
-6
0
91.6
2
2.067
1x(coupling)=1.51
1x(us.45)=3.02
1x(us.90)=7.55
163.66
12.08
175.74
150
0.0528
70.5
0
9.3
056-O
056-I
-6
-6
0
91.6
2
0
0.5
0
0.5
0
0.0459
79.8
0
0.0
GATE VALVE
***
056-I
SRC
-6
-6
0
91.6
2
2.067
1x(us.Tee-Br)=15.1 2.4
15.1
17.5
150
0.0528
79.8
0
0.9
SRC 80.8
2Path No:
s203
249
8
9.5
4.9 22.7
22.7
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2174
21.5
-0.6
1.7
249
248
9.5
9.5
0
22.7
1.25
1.14
1x(RP.TEE-Run)=1.1 16
1.1
17.1
150
0.0726
22.5
0
1.2
248
247
9.5
9.5
23.3
46.1
1.25
1.14
1x(RP.TEE-Run)=1.1 16
1.1
17.1
150
0.2684
23.7
0
4.6
247
170
9.5
9.5
0
46.1
1.5
1.43
1x(RP.TEE-Br)=9.9
1x(RP.45)=2.2
4.49
12.1
16.59
150
0.089
28.3
0
1.5
170
041
9.5
9.5
22.3
68.4
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.45)=2.8
1.95
4.5
6.45
150
0.0603
29.8
0
0.4
041
042
9.5
9.5
8.5
76.9
2
1.8
1x(RP.TEE-Run)=1.7 1.16
1.7
2.86
150
0.0749
30.2
0
0.2
042 30.4
3Path No:
s202
243
8
9.5
4.9 23.1
23.1
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2229
22.1
-0.6
1.7
243 23.1
4Path No:
s204
248
8
9.5
4.9 23.3
23.3
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2282
22.7
-0.6
1.8
248 23.7
Date 7/24/2014 Page 23Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
5Path No:
171
170
9.5
9.5
0
22.3
2
1.8
1x(RP.TEE-Run)=1.7 7.78
1.7
9.48
150
0.0076
29.7
0
0.1
170 29.8
6Path No:
177
219
9.5
19.83
0
11.4
2
1.8
1x(RP.TEE-Run)=1.7
2x(RP.90)=10.4
1x(RP.TEE-Br)=14.4
18.89
26.5
45.39
150
0.0022
30
-4.5
0.1
219
039
19.83
19.83
-3.4
8
2
1.8
3x(RP.TEE-Run)=5.1
1x(RP.TEE-Br)=14.4
1x(RP.45)=2.8
30.81
22.3
53.11
150
0.0011
24.9
0
0.1
039
041
19.83
9.5
0.4
8.5
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
11.38
19.6
30.98
150
0.0013
25
4.5
0.0
041 30.2
7Path No:
179
012
9.5
19.83
0
4.9
2
1.8
5x(RP.TEE-Br)=72
2x(RP.90)=10.4
2x(RP.TEE-Run)=3.4
45.68
85.8
131.48
150
0.0005
30
-4.5
0.1
012
162
19.83
19.83
-2.3
2.6
2
1.8
1x(RP.90)=5.2
2x(RP.TEE-Br)=28.8
13.44
34
47.44
150
0.0001
24.9
0
0
162
261
19.83
31
0
2.6
1.5
1.43
3x(RP.TEE-Run)=4.2
3x(RP.TEE-Br)=29.7
36.51
33.9
70.41
150
0.0004
24.9
-4.8
0.0
261
029
31
31
0
2.6
2
1.8
5x(RP.TEE-Run)=8.5 12.73
8.5
21.23
150
0.0001
19.4
0
0
029
034
31
31
3.7
6.2
2
1.8
2x(RP.TEE-Run)=3.4
1x(RP.TEE-Br)=14.4
2x(RP.45)=5.6
18.86
23.4
42.26
150
0.0007
19.4
0
0.0
034
035
31
31
0.4
6.6
2
1.8
1x(RP.TEE-Run)=1.7 3.2
1.7
4.9
150
0.0008
19.4
0
0
035
093
31
19.83
-0.4
6.2
2
1.8
5x(RP.TEE-Run)=8.5
6x(RP.TEE-Br)=86.4
51.45
94.9
146.35
150
0.0007
19.4
4.8
0.1
093 25.1
8Path No:
025
026
19.83
19.83
0
0.3
2
1.8
1x(RP.TEE-Run)=1.7 4.48
1.7
6.18
150
0
25
0
0
026
029
19.83
31
3.4
3.7
2
1.8
1x(RP.TEE-Br)=14.4
2x(RP.90)=10.4
15.18
24.8
39.98
150
0.0003
25
-4.8
0.0
029 19.4
Date 7/24/2014 Page 24Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
9Path No:
120
034
19.83
31
0
0.4
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.90)=10.4
20.4
39.2
59.6
150
0
25
-4.8
0
034 19.4
10Path No:
219
026
19.83
19.83
0
3.4
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.90)=10.4
2x(RP.45)=5.6
24.21
44.8
69.01
150
0.0002
24.9
0
0.0
026 25
11Path No:
012
024
19.83
19.83
0
2.3
2
1.8
9x(RP.TEE-Run)=15.3
1x(RP.45)=2.8
2x(RP.90)=10.4
29.71
28.5
58.21
150
0.0001
24.9
0
0
024 24.9
12Path No:
035
039
31
19.83
0
0.4
2
1.8
2x(RP.TEE-Run)=3.4
2x(RP.90)=10.4
30.11
13.8
43.91
150
0
19.4
4.8
0
039 25
* Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding.
*** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with
this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The frictionloss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values
are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is basedsolely on the curve data.
* Maximum Velocity of 14.49 ft/s occurs in the following pipe(s): (247-248)
Date 7/24/2014 Page 25Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure vs. Flow Function
Design Area: 2; Supply Ref.: SRC; Supply Name:SRC
Flow, gpm0200300400500600700800900 10001258Pressure, psi100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
87.6 psi @ 191.6 gpm (91.6 gpm+100 gpm add. out. hose)
Pressure Loss Function
Design Area: 2; BFP Ref.: 451 (Wilkins975xlrp, Size = 2); Inlet Node: BFP-I; Outlet Node: BFP-O
Flow, gpm050 100150200225Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
13.7 psi @ 91.6 gpm
Date 7/24/2014 Page 26Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 2; Valve Ref.: 449 (Riser Manifold, Size = 2); Inlet Node: RM-I; Outlet Node: RM-O
Flow, gpm100200 300400500Pressure, psi0.6
0.1
Pressure Loss Function
Design Area: 2; Valve Ref.: 450 (Wilkins 500xl, Size = 2); Inlet Node: PRV-I; Outlet Node: BFP-I
Flow, gpm02550 75100125150160Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
9.6 psi @ 91.6 gpm
Date 7/24/2014 Page 27Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 2; Valve Ref.: 452 (GATE VALVE, Size = 2); Inlet Node: 056-I; Outlet Node: 056-O
Flow, gpm150200250.6300360Pressure, psi0.23
0.13
0.03
Date 7/24/2014 Page 28Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Design
Remote Area Name
Remote Area Location
Occupancy Classification
Density (gpm/ft²)
Area of Application (ft²)
Coverage per Sprinkler (ft²)
Number of Calculated Sprinklers
In-Rack Demand (gpm)
Special Heads
Hose Streams (gpm)
Total Water Required (incl. Hose Streams) (gpm)
Required Pressure at Source (psi)
Type of System
Volume - Entire System (gal)
3
BASEMENT RIGHT
R3
0.1
896
224
4
0
100
193.4
80.1
Wet
105.7 gal
Water Supply Information
Date
Location
Source
HYDRAULIC CALCULATIONS
for
JUNE 17, 2014
JUNIPER LANE
SRC
4 HEAD CALC @ .10
Project Name : Cummings Residence
Contract No. : 14-679
Project Location: 4936 Juniper Lane
City: Vail, Colorado
Date: 7/24/2014
Name of Contractor: Meridian Fire Intermountain
Address: 331 Metcalf Road Bldg B Unit 9
Phone Number: 970-827-9120
Name of Designer: VFE / BAE
Authority Having Jurisdiction: VF&ES
City: Avon, Colorado 81620
E-mail: info@vailelectronics.com
Job Information
Contractor Information
Notes
Date 7/24/2014 Page 29Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceDiagram for Design Area : 3(Optimized Hydraulic Simplified)Node Labels:Pipe Labels:OffOffDate 7/24/2014Page 30Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 3
Water Supply Parameters
Calculation Info
Calculation Mode
Hydraulic ModelFluid Name
Fluid Weight, (lb/ft³)Fluid Dynamic Viscosity, (lb·s/ft²)
Demand
Hazen-WilliamsWater @ 60F (15.6C)
N/A for Hazen-Williams calculation.N/A for Hazen-Williams calculation.
Supply 1 : SRC Flow (gpm)Pressure (psi)
0 89.1
1258 41.3
Inside Hose Flow / Standpipe Demand (gpm)
Outside Hose Flow (gpm)
Additional Outside Hose Flow (gpm)
Other (custom defined) Hose Flow (gpm)
Total Hose Flow (gpm)
100
100
Hoses
Ovehead Sprinkler Flow (gpm)
InRack Sprinkler Flow (gpm)
Other (custom defined) Sprinkler Flow (gpm)
Total Sprinkler Flow (gpm)
93.4
0
0
93.4
Required Margin of Safety (psi)
SRC - Pressure (psi)
SRC - Flow (gpm)
Demand w/o System Pump(s)
0
80.1
93.4
N/A
Sprinklers
Other
Date 7/24/2014 Page 31Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceHydraulic Analysis for : 3SupplySystem DemandAdd. Out. HoseFlow, gpmPressure, psi1009080706050403020100S1S230.866D1D2D2D30 400 500 600 700 800 900 1000 1100 1200 1300 1400Date 7/24/2014Page 32Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 3
Pressure (psi)Label
Graph Labels
Flow (gpm)
ValuesDescription
0S1 89.1Supply point #1 - Static
1258S2 41.3Supply point #2 - Residual
0D1 7Elevation Pressure
93.4D2 80.1System Demand
193.4D3 80.1System Demand + Add.Out.Hose
Pressure (psi)Curve Name
Curve Intersections & Safety Margins
Flow (gpm)
Safety MarginIntersection
Pressure (psi)@ Flow (gpm)
99.2Supply88.7 7.5 193.4
Open Heads
Head Ref.DensityDensityK-Factor PressureFlowPressure
(gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi)
Flow
(gpm)
Coverage
(ft²)
Required CalculatedHead Type
S301 4.9 0.1 22.4 21 0.1 2122.5224Overhead
Sprinkler
S302 4.9 0.1 22.4 21 0.105 23.223.6224OverheadSprinkler
S303 4.9 0.1 22.4 21 0.103 2223224OverheadSprinkler
S304 4.9 0.1 22.4 21 0.109 24.824.4224Overhead
Sprinkler
Date 7/24/2014 Page 33Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
012Node NODERP.TEE 0 19.83 21.84156.38
024Node NODERP.TEE 0 19.83 0.53171.05
025Node NODERP.TEE 0 19.83 -0.45171.05
026Node NODERP.TEE 0 19.83 -0.45166.57
029Node NODERP.TEE 0 31 -1.92164.03
034Node NODERP.TEE 0 31 -18162.81
035Node NODERP.TEE 0 31 -20.27160.55
039Node NODERP.TEE 0 19.83 -33.66154.55
041Node NODERP.TEE 0 9.5 -34.41155.29
042Node NODERP.TEE 0 9.5 -35.23154.47
051Node NODEus.90 0 -6 -62.95156.04
056-INode NODEcoupling 0 -6 -55.094.66
056-ONode NODEcoupling 0 -6 -55.095.16
093Node NODERP.TEE 0 19.83 -44.41163.66
120Node NODERP.TEE 0 19.83 -19.23171.85
162Node NODERP.90 0 19.83 25.01165.52
177Node NODERP.TEE 0 9.5 -2.79155.75
179Node NODERP.TEE 0 9.5 3.16157.56
189Node NODERP.TEE 0 9.5 16.14144.58
190Node NODERP.TEE 0 9.5 27.45133.27
192Node NODERP.TEE 0 9.5 28.74134.56
193Node NODERP.TEE 0 9.5 38.64144.46
195Node NODERP.TEE 0 9.5 17.43145.87
196Node NODERP.TEE 0 9.5 23.67152.11
197Node NODERP.TEE 0 9.5 27.33155.77
Date 7/24/2014 Page 34Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
219Node NODERP.TEE 0 19.83 -5149.39
261Node NODERP.TEE 0 31 7.08155.02
BFP-INode NODEcoupling 0 -6 -63.87155.12
BFP-ONode NODEcoupling 0 -6 -63.52155.47
PRV-INode NODEcoupling 0 -6 -64.58154.41
RM-INode NODEcoupling 0 -2.39 -62.95156.04
RM-ONode NODEcoupling 0 -1.3 -62.95156.04
S301Overhead Sprinkler HEAD 4.90 8224 38.64144.46
S302Overhead Sprinkler HEAD 4.90 8224 27.85155.25
S303Overhead Sprinkler HEAD 4.90 8224 28.74134.56
S304Overhead Sprinkler HEAD 4.90 8224 17.43145.87
SRCSupply SUPPLY 0 -6 -56.093.26
Date 7/24/2014 Page 35Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
S301
193
8
9.5
4.9 22.5
22.5
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2124
21
-0.6
1.7
193
192
9.5
9.5
0
22.5
1.25
1.14
1x(RP.TEE-Run)=1.1 14
1.1
15.1
150
0.0709
21.9
0
1.1
192
190
9.5
9.5
23
45.4
1.25
1.14
1x(RP.TEE-Br)=7.9 1.83
7.9
9.73
150
0.2615
23
0
2.5
190
189
9.5
9.5
0
45.4
2
1.8
1x(RP.TEE-Run)=1.7 16
1.7
17.7
150
0.0283
25.5
0
0.5
189
179
9.5
9.5
11.3
56.7
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.TEE-Br)=14.4
18.36
16.1
34.46
150
0.0427
26
0
1.5
179
177
9.5
9.5
-9.5
47.3
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.45)=2.8
6.7
4.5
11.2
150
0.0304
27.5
0
0.3
177
041
9.5
9.5
-11.9
35.4
2
1.8
8x(RP.TEE-Run)=13.6
1x(RP.45)=2.8
31.8
16.4
48.2
150
0.0178
27.8
0
0.9
041
042
9.5
9.5
31.5
66.9
2
1.8
1x(RP.TEE-Run)=1.7 1.16
1.7
2.86
150
0.0579
28.7
0
0.2
042
RM-O
9.5
-1.3
26.5
93.4
2
1.8
1x(coupling)=0.77
4x(RP.90)=20.8
3x(RP.TEE-Run)=5.1
50.01
26.67
76.68
150
0.1075
28.9
4.7
8.2
RM-O
RM-I
-1.3
-2.39
0
93.4
2
0
1.08
0
1.08
0
0.1725
42.5
0.5
0.2
Riser Manifold
***
RM-I
051
-2.39
-6
0
93.4
2
1.8
1x(us.90)=3.85 3.61
3.85
7.46
150
0.1075
43.2
1.6
0.8
051
BFP-O
-6
-6
0
93.4
2
2.067
1x(coupling)=1.51 0.8
1.51
2.31
150
0.0548
45.8
0
0.1
BFP-O
BFP-I
-6
-6
0
93.4
2
0
0.5
0
0.5
0
27.3641
45.9
0
13.7
Wilkins975xlrp
***
BFP-I
PRV-I
-6
-6
0
93.4
2
0
1
0
1
0
9.8323
59.6
0
9.8
Wilkins 500xl
***
PRV-I
056-O
-6
-6
0
93.4
2
2.067
1x(coupling)=1.51
1x(us.45)=3.02
1x(us.90)=7.55
163.66
12.08
175.74
150
0.0548
69.5
0
9.6
056-O
056-I
-6
-6
0
93.4
2
0
0.5
0
0.5
0
0.0472
79.1
0
0.0
GATE VALVE
***
Date 7/24/2014 Page 36Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
056-I
SRC
-6
-6
0
93.4
2
2.067
1x(us.Tee-Br)=15.1 2.4
15.1
17.5
150
0.0548
79.1
0
1
SRC 80.1
2Path No:
S303
192
8
9.5
4.9 23
23
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2217
22
-0.6
1.7
192 23
3Path No:
S302
197
8
9.5
4.9 23.6
23.6
1
0.91
1x(RP.TEE-Br)=6.3
1x(RP.90)=2.6
2.24
8.9
11.14
150
0.2328
23.2
-0.6
2.6
197
196
9.5
9.5
0
23.6
1.25
1.14
1x(RP.TEE-Br)=7.9 5.17
7.9
13.07
150
0.0777
25
0
1
196
012
9.5
19.83
13.1
36.7
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.90)=10.4
16.66
39.2
55.86
150
0.019
26.1
-4.5
1.1
012
024
19.83
19.83
-12.8
23.8
2
1.8
9x(RP.TEE-Run)=15.3
1x(RP.45)=2.8
2x(RP.90)=10.4
29.71
28.5
58.21
150
0.0086
22
0
0.5
024
025
19.83
19.83
9.5
33.3
2
1.8
1x(RP.TEE-Br)=14.4 0.97
14.4
15.37
150
0.0159
22.5
0
0.2
025
120
19.83
19.83
-12
21.3
2
1.8
3x(RP.TEE-Run)=5.1
1x(RP.90)=5.2
19.26
10.3
29.56
150
0.007
22.7
0
0.2
120
093
19.83
19.83
-5.3
16
2
1.8
5x(RP.TEE-Run)=8.5
2x(RP.TEE-Br)=28.8
5x(RP.45)=14
32.32
51.3
83.62
150
0.0041
22.9
0
0.3
093
042
19.83
9.5
10.5
26.5
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
23.32
19.6
42.92
150
0.0104
23.3
4.5
0.4
042 28.9
4Path No:
S304
195
8
9.5
4.9 24.4
24.4
1
0.91
1x(RP.TEE-Br)=6.3 1.5
6.3
7.8
150
0.2478
24.8
-0.6
1.9
195
196
9.5
9.5
-11.3
13.1
2
1.8
1x(RP.TEE-Br)=14.4 8.83
14.4
23.23
150
0.0028
26
0
0.1
196 26.1
Date 7/24/2014 Page 37Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
5Path No:
179
024
9.5
19.83
0
9.5
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.TEE-Run)=1.7
6x(RP.90)=31.2
30.7
47.3
78
150
0.0016
27.5
-4.5
0.1
024 22.5
6Path No:
177
219
9.5
19.83
0
11.9
2
1.8
1x(RP.TEE-Run)=1.7
2x(RP.90)=10.4
1x(RP.TEE-Br)=14.4
18.89
26.5
45.39
150
0.0024
27.8
-4.5
0.1
219
039
19.83
19.83
7.3
19.2
2
1.8
3x(RP.TEE-Run)=5.1
1x(RP.TEE-Br)=14.4
1x(RP.45)=2.8
30.81
22.3
53.11
150
0.0057
22.8
0
0.3
039
041
19.83
9.5
12.3
31.5
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
11.38
19.6
30.98
150
0.0144
23.1
4.5
0.4
041 28.7
7Path No:
012
162
19.83
19.83
0
12.8
2
1.8
1x(RP.90)=5.2
2x(RP.TEE-Br)=28.8
13.44
34
47.44
150
0.0027
22
0
0.1
162
261
19.83
31
0
12.8
1.5
1.43
3x(RP.TEE-Run)=4.2
3x(RP.TEE-Br)=29.7
36.51
33.9
70.41
150
0.0084
22.1
-4.8
0.6
261
029
31
31
0
12.8
2
1.8
5x(RP.TEE-Run)=8.5 12.73
8.5
21.23
150
0.0027
17.1
0
0.1
029
034
31
31
4.7
17.5
2
1.8
2x(RP.TEE-Run)=3.4
1x(RP.TEE-Br)=14.4
2x(RP.45)=5.6
18.86
23.4
42.26
150
0.0049
17.2
0
0.2
034
035
31
31
5.3
22.8
2
1.8
1x(RP.TEE-Run)=1.7 3.2
1.7
4.9
150
0.0079
17.4
0
0.0
035
039
31
19.83
-10.5
12.3
2
1.8
2x(RP.TEE-Run)=3.4
2x(RP.90)=10.4
30.11
13.8
43.91
150
0.0025
17.4
4.8
0.1
039 23.1
8Path No:
025
026
19.83
19.83
0
12
2
1.8
1x(RP.TEE-Run)=1.7 4.48
1.7
6.18
150
0.0024
22.7
0
0.0
026
219
19.83
19.83
-4.7
7.3
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.45)=5.6
2x(RP.90)=10.4
24.21
44.8
69.01
150
0.001
22.7
0
0.1
219 22.8
9Path No:
120
034
19.83
31
0
5.3
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.90)=10.4
20.4
39.2
59.6
150
0.0005
22.9
-4.8
0.0
034 17.4
Date 7/24/2014 Page 38Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
10Path No:
195
189
9.5
9.5
0
11.3
2
1.8
1x(RP.TEE-Br)=14.4 1.83
14.4
16.23
150
0.0022
26
0
0.0
189 26
11Path No:
035
093
31
19.83
0
10.5
2
1.8
5x(RP.TEE-Run)=8.5
6x(RP.TEE-Br)=86.4
51.45
94.9
146.35
150
0.0019
17.4
4.8
0.3
093 23.3
12Path No:
026
029
19.83
31
0
4.7
2
1.8
1x(RP.TEE-Br)=14.4
2x(RP.90)=10.4
15.18
24.8
39.98
150
0.0004
22.7
-4.8
0.0
029 17.2
* Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding.
*** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed with
this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The frictionloss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values
are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is basedsolely on the curve data.
* Maximum Velocity of 14.28 ft/s occurs in the following pipe(s): (190-192)
Date 7/24/2014 Page 39Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure vs. Flow Function
Design Area: 3; Supply Ref.: SRC; Supply Name:SRC
Flow, gpm0200300400500600700800900 10001258Pressure, psi100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
87.6 psi @ 193.4 gpm (93.4 gpm+100 gpm add. out. hose)
Pressure Loss Function
Design Area: 3; BFP Ref.: 451 (Wilkins975xlrp, Size = 2); Inlet Node: BFP-I; Outlet Node: BFP-O
Flow, gpm050 100150200225Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
13.7 psi @ 93.4 gpm
Date 7/24/2014 Page 40Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 3; Valve Ref.: 449 (Riser Manifold, Size = 2); Inlet Node: RM-I; Outlet Node: RM-O
Flow, gpm100200 300400500Pressure, psi0.6
0.1
Pressure Loss Function
Design Area: 3; Valve Ref.: 450 (Wilkins 500xl, Size = 2); Inlet Node: PRV-I; Outlet Node: BFP-I
Flow, gpm02550 75100125150160Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
9.8 psi @ 93.4 gpm
Date 7/24/2014 Page 41Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 3; Valve Ref.: 452 (GATE VALVE, Size = 2); Inlet Node: 056-I; Outlet Node: 056-O
Flow, gpm150200250.6300360Pressure, psi0.23
0.13
0.03
Date 7/24/2014 Page 42Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Design
Remote Area Name
Remote Area Location
Occupancy Classification
Density (gpm/ft²)
Area of Application (ft²)
Coverage per Sprinkler (ft²)
Number of Calculated Sprinklers
In-Rack Demand (gpm)
Special Heads
Hose Streams (gpm)
Total Water Required (incl. Hose Streams) (gpm)
Required Pressure at Source (psi)
Type of System
Volume - Entire System (gal)
4
FAMILY ROOM LOWER LEVEL
R3
0.1
928
232
4
0
100
193.1
80.7
Wet
103.3 gal
Water Supply Information
Date
Location
Source
HYDRAULIC CALCULATIONS
for
JUNE 17, 2014
JUNIPER LANE
SRC
4 HEAD CALC @ .10
Project Name : Cummings Residence
Contract No. : 14-679
Project Location: 4936 Juniper Lane
City: Vail, Colorado
Date: 7/24/2014
Name of Contractor: Meridian Fire Intermountain
Address: 331 Metcalf Road Bldg B Unit 9
Phone Number: 970-827-9120
Name of Designer: VFE / BAE
Authority Having Jurisdiction: VF&ES
City: Avon, Colorado 81620
E-mail: info@vailelectronics.com
Job Information
Contractor Information
Notes
Date 7/24/2014 Page 43Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceDiagram for Design Area : 4(Optimized Hydraulic Simplified)Node Labels:Pipe Labels:OffOffDate 7/24/2014Page 44Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 4
Water Supply Parameters
Calculation Info
Calculation Mode
Hydraulic ModelFluid Name
Fluid Weight, (lb/ft³)Fluid Dynamic Viscosity, (lb·s/ft²)
Demand
Hazen-WilliamsWater @ 60F (15.6C)
N/A for Hazen-Williams calculation.N/A for Hazen-Williams calculation.
Supply 1 : SRC Flow (gpm)Pressure (psi)
0 89.1
1258 41.3
Inside Hose Flow / Standpipe Demand (gpm)
Outside Hose Flow (gpm)
Additional Outside Hose Flow (gpm)
Other (custom defined) Hose Flow (gpm)
Total Hose Flow (gpm)
100
100
Hoses
Ovehead Sprinkler Flow (gpm)
InRack Sprinkler Flow (gpm)
Other (custom defined) Sprinkler Flow (gpm)
Total Sprinkler Flow (gpm)
93.1
0
0
93.1
Required Margin of Safety (psi)
SRC - Pressure (psi)
SRC - Flow (gpm)
Demand w/o System Pump(s)
0
80.7
93.1
N/A
Sprinklers
Other
Date 7/24/2014 Page 45Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings ResidenceHydraulic Analysis for : 4SupplySystem DemandAdd. Out. HoseFlow, gpmPressure, psi1009080706050403020100S1S230.866D1D2D2D30 400 500 600 700 800 900 1000 1100 1200 1300 1400Date 7/24/2014Page 46Copyright © 2002-2012 Tyco Fire Protection ProductsFile: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Hydraulic Analysis for : 4
Pressure (psi)Label
Graph Labels
Flow (gpm)
ValuesDescription
0S1 89.1Supply point #1 - Static
1258S2 41.3Supply point #2 - Residual
0D1 12Elevation Pressure
93.1D2 80.7System Demand
193.1D3 80.7System Demand + Add.Out.Hose
Pressure (psi)Curve Name
Curve Intersections & Safety Margins
Flow (gpm)
Safety MarginIntersection
Pressure (psi)@ Flow (gpm)
98.8Supply88.7 6.9 193.1
Open Heads
Head Ref.DensityDensityK-Factor PressureFlowPressure
(gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi)
Flow
(gpm)
Coverage
(ft²)
Required CalculatedHead Type
S401 4.9 0.1 23.2 22.4 0.1 22.423.2232Overhead
Sprinkler
S402 4.9 0.1 23.2 22.4 0.101 22.623.3232OverheadSprinkler
S403 4.9 0.1 23.2 22.4 0.101 22.623.3232OverheadSprinkler
S404 4.9 0.1 23.2 22.4 0.1 22.423.2232Overhead
Sprinkler
Date 7/24/2014 Page 47Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
012Node NODERP.TEE 0 19.83 21.84156.38
024Node NODERP.TEE 0 19.83 0.53171.05
025Node NODERP.TEE 0 19.83 -0.45171.05
026Node NODERP.TEE 0 19.83 -0.45166.57
029Node NODERP.TEE 0 31 -1.92164.03
034Node NODERP.TEE 0 31 -18162.81
035Node NODERP.TEE 0 31 -20.27160.55
039Node NODERP.TEE 0 19.83 -33.66154.55
041Node NODERP.TEE 0 9.5 -34.41155.29
042Node NODERP.TEE 0 9.5 -35.23154.47
051Node NODEus.90 0 -6 -62.95156.04
056-INode NODEcoupling 0 -6 -55.094.66
056-ONode NODEcoupling 0 -6 -55.095.16
093Node NODERP.TEE 0 19.83 -44.41163.66
116Node NODERP.TEE 0 19.83 -20.26171.85
118Node NODERP.TEE 0 19.83 -4.26171.85
120Node NODERP.TEE 0 19.83 -19.23171.85
121Node NODERP.90 0 19.83 -4.26166.08
125Node NODERP.90 0 19.83 -20.26166.08
162Node NODERP.90 0 19.83 25.01165.52
177Node NODERP.TEE 0 9.5 -2.79155.75
179Node NODERP.TEE 0 9.5 3.16157.56
216Node NODERP.TEE 0 19.83 -9.37149.39
217Node NODERP.TEE 0 19.83 -25.37149.39
219Node NODERP.TEE 0 19.83 -5149.39
Date 7/24/2014 Page 48Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Job : Cummings Residence
Node Data
Hydraulic Calculations / Fluid Delivery Time Analysis
Node#Type HgroupFitting K-Fact.Stat. Pres.
gpm/psi½
psi
ElevCoverage
ft
ft²
XY
ft
ft
224Node NODERP.90 0 19.83 -25.37151.49
225Node NODERP.90 0 19.83 -9.37151.49
261Node NODERP.TEE 0 31 7.08155.02
BFP-INode NODEcoupling 0 -6 -63.87155.12
BFP-ONode NODEcoupling 0 -6 -63.52155.47
PRV-INode NODEcoupling 0 -6 -64.58154.41
RM-INode NODEcoupling 0 -2.39 -62.95156.04
RM-ONode NODEcoupling 0 -1.3 -62.95156.04
S401Overhead Sprinkler HEAD 4.90 18232 -4.26166.08
S402Overhead Sprinkler HEAD 4.90 18232 -25.37151.49
S403Overhead Sprinkler HEAD 4.90 18232 -9.37151.49
S404Overhead Sprinkler HEAD 4.90 18232 -20.26166.08
SRCSupply SUPPLY 0 -6 -56.093.26
Date 7/24/2014 Page 49Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
S401
121
18
19.83
4.9 23.2
23.2
1
0.91
1x(RP.90)=2.6 1.83
2.6
4.43
150
0.2256
22.4
-0.8
1
121
118
19.83
19.83
0
23.2
1.25
1.14
1x(RP.TEE-Br)=7.9 5.77
7.9
13.67
150
0.0753
22.5
0
1
118
025
19.83
19.83
-7.4
15.8
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.90)=5.2
4.29
6.9
11.19
150
0.004
23.5
0
0.0
025
024
19.83
19.83
-3.8
12
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.TEE-Br)=14.4
0.97
16.1
17.07
150
0.0024
23.6
0
0.0
024
179
19.83
9.5
-4.2
7.7
2
1.8
2x(RP.TEE-Run)=3.4
6x(RP.90)=31.2
1x(RP.TEE-Br)=14.4
30.7
49
79.7
150
0.0011
23.6
4.5
0.1
179
177
9.5
9.5
5.1
12.8
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.45)=2.8
6.7
4.5
11.2
150
0.0027
28.9
0
0.0
177
041
9.5
9.5
16.4
29.2
2
1.8
8x(RP.TEE-Run)=13.6
1x(RP.45)=2.8
31.8
16.4
48.2
150
0.0125
28.9
0
0.6
041
042
9.5
9.5
35.3
64.5
2
1.8
1x(RP.TEE-Run)=1.7 1.16
1.7
2.86
150
0.0541
29.5
0
0.2
042
RM-O
9.5
-1.3
28.5
93.1
2
1.8
1x(coupling)=0.77
4x(RP.90)=20.8
3x(RP.TEE-Run)=5.1
50.01
26.67
76.68
150
0.1066
29.6
4.7
8.2
RM-O
RM-I
-1.3
-2.39
0
93.1
2
0
1.08
0
1.08
0
0.1718
43.2
0.5
0.2
Riser Manifold
***
RM-I
051
-2.39
-6
0
93.1
2
1.8
1x(us.90)=3.85 3.61
3.85
7.46
150
0.1066
43.9
1.6
0.8
051
BFP-O
-6
-6
0
93.1
2
2.067
1x(coupling)=1.51 0.8
1.51
2.31
150
0.0544
46.5
0
0.1
BFP-O
BFP-I
-6
-6
0
93.1
2
0
0.5
0
0.5
0
27.3887
46.6
0
13.7
Wilkins975xlrp
***
BFP-I
PRV-I
-6
-6
0
93.1
2
0
1
0
1
0
9.794
60.3
0
9.8
Wilkins 500xl
***
PRV-I
056-O
-6
-6
0
93.1
2
2.067
1x(coupling)=1.51
1x(us.45)=3.02
1x(us.90)=7.55
163.66
12.08
175.74
150
0.0544
70.1
0
9.6
056-O
056-I
-6
-6
0
93.1
2
0
0.5
0
0.5
0
0.0469
79.7
0
0.0
GATE VALVE
***
Date 7/24/2014 Page 50Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
1Path No:
056-I
SRC
-6
-6
0
93.1
2
2.067
1x(us.Tee-Br)=15.1 2.4
15.1
17.5
150
0.0544
79.7
0
1
SRC 80.7
2Path No:
S404
125
18
19.83
4.9 23.2
23.2
1
0.91
1x(RP.90)=2.6 1.83
2.6
4.43
150
0.2258
22.4
-0.8
1
125
116
19.83
19.83
0
23.2
1.25
1.14
1x(RP.TEE-Br)=7.9 5.77
7.9
13.67
150
0.0754
22.5
0
1
116
093
19.83
19.83
-5
18.2
2
1.8
4x(RP.TEE-Run)=6.8
2x(RP.TEE-Br)=28.8
5x(RP.45)=14
31.29
49.6
80.89
150
0.0052
23.6
0
0.4
093
042
19.83
9.5
10.3
28.5
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
23.32
19.6
42.92
150
0.0119
24
4.5
0.5
042 29.6
3Path No:
S403
225
18
19.83
4.9 23.3
23.3
1
0.91
1x(RP.90)=2.6 1.83
2.6
4.43
150
0.2278
22.6
-0.8
1
225
216
19.83
19.83
0
23.3
1.25
1.14
1x(RP.TEE-Br)=7.9 2.1
7.9
10
150
0.076
22.7
0
0.8
216
219
19.83
19.83
-2
21.3
2
1.8
1x(RP.TEE-Run)=1.7 4.37
1.7
6.07
150
0.007
23.5
0
0.0
219
177
19.83
9.5
-5
16.4
2
1.8
1x(RP.TEE-Br)=14.4
2x(RP.90)=10.4
18.89
24.8
43.69
150
0.0043
23.5
4.5
0.2
177 28.9
Date 7/24/2014 Page 51Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
4Path No:
S402
224
18
19.83
4.9 23.3
23.3
1
0.91
1x(RP.90)=2.6 1.83
2.6
4.43
150
0.2278
22.6
-0.8
1
224
217
19.83
19.83
0
23.3
1.25
1.14
1x(RP.TEE-Br)=7.9 2.1
7.9
10
150
0.076
22.7
0
0.8
217
039
19.83
19.83
2
25.3
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.TEE-Br)=14.4
1x(RP.45)=2.8
10.43
18.9
29.33
150
0.0096
23.5
0
0.3
039
041
19.83
9.5
10
35.3
2
1.8
1x(RP.TEE-Br)=14.4
1x(RP.90)=5.2
11.38
19.6
30.98
150
0.0177
23.8
4.5
0.5
041 29.5
5Path No:
118
120
19.83
19.83
0
7.4
2
1.8
1x(RP.TEE-Run)=1.7
1x(RP.TEE-Br)=14.4
14.97
16.1
31.07
150
0.001
23.5
0
0.0
120
034
19.83
31
5
12.4
2
1.8
1x(RP.TEE-Br)=14.4
2x(RP.90)=10.4
20.4
24.8
45.2
150
0.0026
23.6
-4.8
0.1
034
035
31
31
7.9
20.3
2
1.8
1x(RP.TEE-Run)=1.7 3.2
1.7
4.9
150
0.0064
18.1
0
0.0
035
093
31
19.83
-10
10.3
2
1.8
5x(RP.TEE-Run)=8.5
6x(RP.TEE-Br)=86.4
51.45
94.9
146.35
150
0.0018
18.1
4.8
0.3
093 24
6Path No:
025
026
19.83
19.83
0
3.8
2
1.8
1x(RP.TEE-Run)=1.7 4.48
1.7
6.18
150
0.0003
23.6
0
0
026
029
19.83
31
5
8.8
2
1.8
1x(RP.TEE-Br)=14.4
2x(RP.90)=10.4
15.18
24.8
39.98
150
0.0013
23.6
-4.8
0.1
029
034
31
31
-0.9
7.9
2
1.8
2x(RP.TEE-Run)=3.4
1x(RP.TEE-Br)=14.4
2x(RP.45)=5.6
18.86
23.4
42.26
150
0.0011
18.1
0
0.0
034 18.1
Date 7/24/2014 Page 52Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
7Path No:
024
012
19.83
19.83
0
4.2
2
1.8
9x(RP.TEE-Run)=15.3
2x(RP.90)=10.4
1x(RP.45)=2.8
29.71
28.5
58.21
150
0.0003
23.6
0
0.0
012
179
19.83
9.5
0.9
5.1
2
1.8
2x(RP.TEE-Run)=3.4
5x(RP.TEE-Br)=72
2x(RP.90)=10.4
45.68
85.8
131.48
150
0.0005
23.6
4.5
0.1
179 28.9
8Path No:
116
120
19.83
19.83
0
5
2
1.8
1x(RP.TEE-Br)=14.4 1.03
14.4
15.43
150
0.0005
23.6
0
0
120 23.6
9Path No:
216
217
19.83
19.83
0
2
2
1.8
1x(RP.TEE-Run)=1.7 16
1.7
17.7
150
0.0001
23.5
0
0
217 23.5
10Path No:
219
026
19.83
19.83
0
5
2
1.8
2x(RP.TEE-Br)=28.8
2x(RP.90)=10.4
2x(RP.45)=5.6
24.21
44.8
69.01
150
0.0005
23.5
0
0.0
026 23.6
11Path No:
035
039
31
19.83
0
10
2
1.8
2x(RP.TEE-Run)=3.4
2x(RP.90)=10.4
30.11
13.8
43.91
150
0.0017
18.1
4.8
0.1
039 23.8
12Path No:
029
261
31
31
0
0.9
2
1.8
5x(RP.TEE-Run)=8.5 12.73
8.5
21.23
150
0.0000
18.1
0
0
261
162
31
19.83
0
0.9
1.5
1.43
3x(RP.TEE-Run)=4.2
3x(RP.TEE-Br)=29.7
36.51
33.9
70.41
150
0.0001
18.1
4.8
0
162
012
19.83
19.83
0
0.9
2
1.8
1x(RP.90)=5.2
2x(RP.TEE-Br)=28.8
13.44
34
47.44
150
0.0000
23.6
0
0
012 23.6
Date 7/24/2014 Page 53Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Hydraulic CalculationsJob : Cummings Residence
PIPE INFORMATION
Node 1
Node 2
Elev 1
Elev 2
(ft)
K-Factor 1
K-Factor 2
(gpm/psi½)
Flow added (q)
Total flow (Q)
(gpm)
Nominal ID
Actual ID
(in)
Fittings
quantity x (name) = length
(ft)
L
F
T
(ft)
C Factor
Pf per ft
(psi)
total (Pt)
elev (Pe)
frict (Pf)
(psi)
NOTES
* Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding.
*** Device pressure loss (gain in the case of pumps) is calculated from the device’s curve. If the device curve is printed withthis report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction
loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor valuesare irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based
solely on the curve data.
* Maximum Velocity of 11.73 ft/s occurs in the following pipe(s): (RM-O-042), (051-RM-I)
Date 7/24/2014 Page 54Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure vs. Flow Function
Design Area: 4; Supply Ref.: SRC; Supply Name:SRC
Flow, gpm0200300400500600700800900 10001258Pressure, psi100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
87.6 psi @ 193.1 gpm (93.1 gpm+100 gpm add. out. hose)
Pressure Loss Function
Design Area: 4; BFP Ref.: 451 (Wilkins975xlrp, Size = 2); Inlet Node: BFP-I; Outlet Node: BFP-O
Flow, gpm050 100150200225Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
13.7 psi @ 93.1 gpm
Date 7/24/2014 Page 55Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 4; Valve Ref.: 449 (Riser Manifold, Size = 2); Inlet Node: RM-I; Outlet Node: RM-O
Flow, gpm100200 300400500Pressure, psi0.6
0.1
Pressure Loss Function
Design Area: 4; Valve Ref.: 450 (Wilkins 500xl, Size = 2); Inlet Node: PRV-I; Outlet Node: BFP-I
Flow, gpm02550 75100125150160Pressure, psi21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
9.8 psi @ 93.1 gpm
Date 7/24/2014 Page 56Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$
Device GraphsJob : Cummings Residence
Pressure Loss Function
Design Area: 4; Valve Ref.: 452 (GATE VALVE, Size = 2); Inlet Node: 056-I; Outlet Node: 056-O
Flow, gpm150200250.6300360Pressure, psi0.23
0.13
0.03
Date 7/24/2014 Page 57Copyright © 2002-2012 Tyco Fire Protection Products
File: C:\Users\Bryan\appdata\local\temp\lower fp_1_2_4443.sv$