HomeMy WebLinkAboutF14-0028 Material Submittal.pdfaquatherm 500 S 500 W Lindon, UT, 84042 801.805.6657 RED PIPE SUBMITTAL SPECIFICATION DATASHEET 1. Product Name Polypropylene-random copolymer (PP-R) pipe and fittings for wet fire suppression system: Aquatherm Red Pipe – ½”-8” SDR 7.4 fire suppression system. 2. Product Description Basic Use: Aquatherm Red Pipe PP-R pipe and fittings are used in pressure piping systems in residential, commercial, and industrial applications. The pipe and fittings are joined by heat fusion-welding (socket, butt, fusion outlet) and do not require any glues, solvents, solder, flux, or other materials. The resulting bond is a homogenous continuation of the PP-R material between pipe and fitting, creating a joint that is stronger than either the pipe or fitting. The piping system includes a variety of transitions fittings for connection to other piping materials. Composition and Materials: PP-R is a thermoplastic material with exceptional high-temperature and chemical resistance. The PP-R material is listed per ASTM D4101 and meets the long-term strength, pressure-rating, and high-temperature performance requirements of FM 1635. Limitations: The piping system is intended to be used in the systems described above. Other applications should be reviewed with the manufacturer to determine suitability. In general, the PP-R material has exceptional chemical resistance, but specific chemicals, applications, and operating conditions must be reviewed by Aquatherm prior to use. All plastics are susceptible to UV degradation. The piping material includes UV inhibitors which ensure it will not degrade while exposed to UV during construction. However, if the piping is installed in a location subject to UV exposure, it must be protected by use of an appropriate UV-resistant wrap or coating. 3. Technical Data Applicable Standards: FM 1635, ASTM D4101, ASTM E84, CAN/ULC S102.2, FM 1635, NFPA 13, NFPA 13R, NFPA 13D Quality Control, Listings: The Aquatherm PP-R piping systems are listed and inspected by numerous independent third-party agencies globally. In North America, the Red Pipe piping system is listed by Factory Mutual (FM), and Intertek in accordance with the applicable standards and noted in listings per FM 1635, NFPA 13, NFPA 13R, NFPA 13D; and Intertek Aquatherm Advanced® (ASTM E84 and CAN/ULC S102.2). Construction Codes: PP-R piping is permitted to be used in concealed wet fire protection applications in the following national model codes: International Building Code (IBC), National Fire Protection Association (NFPA) 13, NFPA 13R, and NFPA 13D. 4. Approval PP-R pressure piping shall be Aquatherm, manufactured in accordance with ASTM F2389 and FM 1635, and shall be listed/approved by a Nationally Recognized Testing Laboratory (OSHA NRTL). ©2013 Aquatherm NA, L.C. All rights reserved. www.aquatherm.com Corrosion in fire extinguishing systems carries the risk that the sprinkler system may fail when it is needed most. Leaks at the joints increase installation and maintenance costs. The red pipe system developed by aquatherm pre- vents both and offers a high level of security due to its flame-resistant properties. The material fusiolen® PP-R FS, used for the pipe production, is a plastic whose properties are de- signed for the special demands of the fields of application. Example of installation advantages • certified and quality inspected • connection by fusion welding • low weight compared to metal pipes • resistant against corrosion and chemicals • short processing time • heat and sound-insulating characteristics • 3-layer pipe with fibre glass reinforced layer • not easily flammable acc. to DIN 4102-1, building material class B1 • concealed fire protection • reduction of structural works costs by laying in concrete Sprinkler outlet aquatherm red PiPe system for sPrinklersystems aquatherm red aquatherm GmbH I Biggen 5 I D-57439 Attendorn info@aquatherm.de I www.aquatherm.de aquatherm 500 S 500 W Lindon, UT 84042 801.805.6657 Aquatherm Red Pipe Dimensional Data SDR 7.4 MF Diameter Wal Thickness Internal Diameter Water Capacity Weight Part No.Dimension (ND - OD) d, in, (mm) s, in., (mm) d 1 in, (mm)gal/ft.lb./ft. 4170708 1/2" - 20 mm 0.79, (20)0.11, (2.8)0.57, (14.4)0.013 0.11 4170710 3/4" - 25 mm 0.98, (25)0.14, (3.5)0.71, (18)0.024 0.17 4170712 1" - 32 mm 1.26, (32)0.173, (4.4)0.91, (23.2)0.034 0.27 4170714 1-1/4" - 40 mm 1.57, (40)0.22, (5.5)1.14, (29)0.053 0.41 4170716 1-1/2" - 50 mm 1.97, (50)0.27, (6.9)1.43, (36.2)0.083 0.64 4170718 2" - 63 mm 2.48, (63)0.34, (8.6)1.80, (45.8)0.133 1.01 4170720 2-1/2" - 75 mm 2.95, (75)0.41, (10.3)2.14, (54.4)0.187 1.44 4170722 3" - 90 mm 3.54, (90)0.48, (12.3)2.57, (65.4)0.27 2.06 4170724 3-1/2" - 110 mm 4.33, (110)0.59, (15.1)3.14, (79.8)0.402 3.08 4170726 4" - 125 mm 4.92, (125)0.67, (17.1)3.57, (90.8)0.521 3.96 Pipe General Description The Riser Manifolds described in this technical data sheet provide the nec- essary waterflow alarm, pressure gauge,and drain equipmentin a single assembly for use in NFPA 13D or 13R residential sprinkler systems as fol- lows: NFPA 13D •Figure 513D (13D) 1 Inch (DN25) Female Thread x Female Thread NFPA 13D/13R •Figure 513D/R (13D/R) 1-1/2 Inch (DN40) Male Thread x Female Thread Male Thread x Male Thread •Figure 513D/R (13D/R) 2 Inch (DN50) Groove x Groove Male Thread x Groove The variety of sizes and end connec- tions allow cost effective and easy transition to check valves, control valves, and system piping. The Riser Manifoldsmaybeinstalledineitherthe horizontal (flow switch on top) or verti- cal (flow going up). WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion.Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals The Figure 513D (13D) and 513D/R (13D/R) Riser Manifolds with a cover tamper switch for the waterflow alarm switch are UL Listed, ULC Listed, and FM Approved. The Figure 513D (13D) and 513D/R (13D/R) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end-to-end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut-off control valve. NOTES (1) Where applicable pipe thread sealant is to be applied sparingly. Use ofa non-hardening pipe threadsealant is recommended. (2) Provisions for an alarm test flow must be made. The alarm test flow is to be through an orifice having a flow capacity equal to or smaller than the smallestorificesprinklerinthesystem. One of two options can be considered. The first option is to temporarily install a test orifice in the outlet of the drain line prior to performing the alarm test. The second option is to install an In- spector’s Test Connection down- stream of the Waterflow Alarm Switch. (3) Never remove any piping compo- nent nor correct or modify any piping deficiencies without first depressuriz- ing and draining the system. Step 1.Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable. Step 2.Connect the drain line, and then close the drain valve. Step 3.Refer to Figure 4 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and/or the Na- tional Electrical Code. Step 4.Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system.Fill- ing the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 5.Secure all supply valves open. Figure 513D (13D) and 513D/R (13D/R) Riser Manifolds 1, 1-1/2, and 2 Inch (DN25, DN40, and DN50) For NFPA 13D/13R Residential Sprinkler Systems Page 1 of 6 TFP960APRIL, 2006 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 Page2of6 TFP960 FIGURE 1 1 INCH (DN25) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 4-1/2" to the Waterflow Alarm Switches. Cover Tamper Switches installed internal ULC Listed Manifolds are equipped with (114,3 mm) 10" (254,0 mm) Approximate weight, 7.5 lbs. (3,4 kg).1. 2. NOTES: 3/4" NPT (92,1 mm) 3-5/8"1 (73,0 mm) 2-7/8" 9-3/4" (247,7 mm) Waterflow 3 2 CH: Common Hardware3. (88,9 mm) 3-1/2" Paddle and Cover Tamper VSR-SF modified with QTY.DESCRIPTION Female x Female NPT 1" Manifold Body, Water Pressure Gauge 200 psi/1400 kPa VSR-SF modified with Waterflow Alarm Switch: 1 3 2 NO. ..1 . . . 1 N/A 2343 P/N Paddle, UL/FM . . . . . . . . 1 971-096-01 Switch, ULC/FM 1 976-519-01........ (Normally Closed) Drain Valve FIGURE 2 1-1/2 INCH (DN40) RISER MANIFOLD ASSEMBLY AND DIMENSIONS (136,5 mm) 5-3/8" (288,9 mm) 11-3/8" Male x Male NPT Manifold 11-1/8" (282,6 mm) (54,0 mm) Male x Female NPT Manifold 10" (254,0 mm) NPT 2-1/8" 1" (114,3 mm) 4-1/2" Waterflow 32 to the Waterflow Alarm Switches. Cover Tamper Switches installed internal ULC Listed Manifolds are equipped with Approximate weight, 8.7 lbs. (3,9 kg).1. 2. NOTES: CH: Common Hardware3. (88,9 mm) 3-1/2" QTY.DESCRIPTION 1-1/2" Manifold Body, Male x Female NPT Water Pressure Gauge 300 psi/2000 kPa3 2 1 NO. ..1 .....1 2341 N/A P/N Switch, ULC/FM. . . . . . . . 1 976-519-02 ......... Waterflow Alarm Switch: VSR-SF modified with VSR-SF modified with Paddle and Cover Tamper Paddle, UL/FM 971-096-001 1 (Normally Closed) Drain Valve Male x Male NPT . . . . . . . 1 N/A Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stallingcontractor orproductmanufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Noattemptistobemadetorepairany Riser Manifold component in the field. Only the pressure gauge or waterflow alarm switch can be replaced. If any other problems are encountered the entire riser manifold must be replaced. The flow and alarm test procedure will result in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise thoseresponsibleformoni- toring proprietary and/or central sta- tion alarms. Flow Test Procedure Step 1.Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 2.Verify that the residual (flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 3.Close the drain valve. Step 4.Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Alarm Test Procedure With A Test Orifice (See Installation Note 2) Step 1.Temporarily install a test ori- fice in the drain line outlet. Step 2.Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3.Verify operation of the associ- ated alarms. Step 3.Close the drain valve. Step 4.Remove the test orifice from the drain line outlet. Alarm Test Procedure With An Inspector’s Test Connection (See Installation Note 2) Step 1.Fully open the Inspector’s Test Connection Valve. Make certain that drainagewaterwillnotcauseanydam- age or injury. Step 2.Verify operation of the associ- ated alarms. Step 3.Close the Inspector’s Test Connection Valve. TFP960 Page3of6 FIGURE 3, 2 INCH (DN50) RISER MANIFOLD ASSEMBLY AND DIMENSIONS Optionally Supply End Grooved or Male NPT (57,2 mm) (114,3 mm) 2-1/4" 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal to the Waterflow Alarm Switches. .......1 N/AGroove x Groove Male NPT x Groove 300 psi/2000 kPa Water Pressure Gauge Approximate weight, 11.0 lbs. (5,0 kg). NOTES: 1. 3 2 5-7/16" (138,1 mm) 1" NPT 4-1/2" . . 1 2341 (304,8 mm) 12" N/A1..... Waterflow DESCRIPTION 2" Manifold Body,1 NO. P/NQTY. 3 2 CH: Common Hardware3. ULC/FM . . . . . . . . . . . . . . 1 976-520-01 ............... Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, UL/FM 976-357-011 13" (330,2 mm) Male NPT x Groove Groove x Groove, Connection (88,9 mm) 3-1/2" 1 (Normally Closed) Drain Valve Page4of6 TFP960 FIGURE 4 WIRING GUIDANCE INCOMING OUTGOING SINGLE CONDUCTOR TERMINAL PLATE LOOPED SECTION UNINSULATED CLAMPING CONDUCTORS SEPARATE STRIPPED ENDS SWITCH TERMINAL CONNECTIONS CLAMPING TERMINAL PLATE IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD SEVERED CAUTION: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS COM NCNO NO FLOW CONTACTS SPDT (Form C) 5A @ 125 VACCONTACT RATING 2.5A @ 30 VDC .......... .... COM NO NC POWER SIGNAL LOCAL DEVICE NON-SUPERVISED CIRCUITCONDITION END OF LINE RESISTOR COM SUPERVISED CIRCUIT STYLE B/CLASS B CONTROL NO NC PANEL signaling unit, while the other contact is used to operate a local audible or visual annunciator. Switch has two switches, one can be used to operate a central station, proprietary or remove For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm NOTE: (SEE NOTE) COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS SHOWN WITH COVER IN PLACE COM .......... ....CONTACT RATING NO CONTACTS 3A @ 250 VAC 5A @ 125 VAC NC SPDT (Form C) 1mA @ 5 VDC min. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which havebeensubjecttomisuse,improper installation,corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume forit, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer’s repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,specialorconsequentialdam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, ex- press or implied, including warranties ofmerchantabilityandfitnessforapar- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure (specify 513D or 513D/R, (specify connection type inlet x outlet) Riser Manifold (specify - without or with) a cover tam- per switch for the waterflow alarm switch, P/N (specify). NOTES Orders forFigure513D or 513D/Rmay be filled with a Figure 13D or 13D/R, respectively. The two assemblies are completely interchangeable in func- tion, application, and end-to-end lay- ing length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. UL/ULC/FM Assemblies With Cover Tamper Switch 1 Inch (DN25) FT x FT. . . . . . . . . . . . . . . P/N 4085 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4088 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4089 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4093 2 Inch (DN50) MT x G . . . . . . . . . . . . . . . P/N 4094 UL/FM Assemblies Without Cover Tamper Switch 1 Inch (DN25) FT x FT. . . . . . . . . . . . . . . P/N 4047 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4057 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4058 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4059 2 Inch (DN50) MT x G . . . . . . . . . . . . . . . P/N 4064 Replacement Parts: Specify: (description) for use with Fig- ure 513D, 513D/R, 13D, or 13D/R Riser Manifold, P/N (Ref. Figure 1, 2 or 2, as applicable). TFP960 Page5of6 Page6of6 TFP960 TYCO FIRE & BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. D Date: 5/14 Document No. REG-500XL Product No. Model 500XL Model 500XL Water Pressure Reducing Valve with Integral By-pass Check Valve Page 1 of 2 500XL WILKINS D B AC Options (Suffixes can be combined) - standard with single union FNPT inlet x FNPT outlet (1/2” thru 2”) and less union (21/2” & 3”) C - copper sweat connection (1/2" thru 2") copper sweat strainer 3/4" & 1" only All other strainers are FNPT HR - 75 psi to 125 psi spring range, factory set at 85 psi (field set 2 1/2” & 3”) HLR - 10 psi to 125 psi spring range, factory set at 50 psi HTSTSC - 180°F maximum temp, stainless steel trim, spring, sealed cage L - less integral by-pass check valve (3/4”-2”) LPV - 180°F maximum temp with 10 psi to 35 psi spring range, factory set at 20 psi LPC - 140°F maximum temp with 10 psi to 35 psi spring range, factory set at 20 psi SC - sealed cage bell housing and stainless steel adjustment screw SW - made for salt water service YSBR - with lead-free bronze “Y” strainer on inlet 510XL - 400 psi inlet rating and 75 psi to 125 psi spring range, factory set at 85 psi (field set 2 1/2” & 3”) P - tapped and plugged for gauge G - with 0-100 psi gauge included CPVC - CPVC tailpiece connection (3/4”-1”) Accessories Repair kit (rubber only) Application Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The high flow capacity makes this device most suitable for industrial water lines and commercial irrigation systems. The direct acting integral by- pass design prevents buildup of excessive system pressure caused by thermal expansion. The balanced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes. Standards Compliance • ASSE® Listed 1003 (1/2" thru 2 1/2") • IAPMO® Listed (1/2" thru 2") • CSA® Certified (1/2" thru 2") • City of Los Angeles Approved (1/2" thru 2") • NSF® Listed - Standard 61, Annex G* • Certified to NSF/ANSI 372* by IAPMO R&T *(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Cast bronze ASTM B 584 Access covers Cast bronze ASTM B 584 Low Lead Brass Fasteners Stainless steel, 300 series Stem & plunger Cast bronze ASTM B 584 Low Lead Brass Elastomers Buna Nitrile (FDA approved) EPDM (FDA approved) Cap gaskets Natural vulcanized fibre Acetal (Delrin™ 500), NSF Listed Springs Oil tempered wire, ASTM A 229 Seat Stainless steel, 300 series Features Sizes: 1/2", 3/4", 1", 1 1/4", 1 1/2", 2", 2 1/2", 3" Maximum working water pressure 300 psi Maximum working water temperature 140° F Reduced pressure range 25 psi to 75 psi Factory preset (field set 2 1/2” & 3”) 50 psi Threaded connections (FNPT) ANSI B1.20.1 Copper connections (FC) ANSI B 16.22 CPVC tailpiece: Max.hot water temp. 140°F @ 100 psi Cold water rated temp. 73.4°F @ 400 psi Dimensions & Weights (do not include pkg.) ഌFlow Characteristics Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 Speci cations The Pressure Reducing Valve shall be certified to NSF/ANSI 372, consisting of a low lead bronze body and bronze bell housing, a separate access cover for the plunger and a bolt to adjust the downstream pressure. The bronze bell housing and access cap shall be threaded to the body and shall not require the use of ferrous screws. The assembly shall be of the balanced piston design and shall reduce pressure in both flow and no-flow conditions. The assembly shall be accessible for maintenance without having to remove the body from the line. The Pressure Reducing Valve shall be a ZURN WILKINS Model 500XL. FLOW RATES (GPM)FALL OFF (PSIG) 0 5 10 15 0 100 200 300 69 104 6.3 12.6 18.9 FALL OFF (kpa) FLOW RATES (l/s) MODEL 500XL 1/2" THRU 3" (STANDARD & METRIC) 3/4" (20mm) 35 20 1381/2" (15mm) 1" (25mm) 1 1/4" (32mm) 1 1/2" (40mm) 2" (50mm) 2 1/2" (65mm) 3" (80mm) 50 150 250 3.2 9.5 15.8 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers’ instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the “SC” sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Caution: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure set- ting. Do not bottom adjustment bolt on bell housing. VERTICAL INSTALLATION BATTERY INSTALLATION TYPICAL INSTALLATION MODEL 975XL2 RPZ BACKFLOW PREVENTER PROTECTIVE ENCLOSURE OPTIONAL PRESSURE GAUGE 12" MIN. 30" MAX. MODEL DUXL DIELECTRIC UNION DIRECTION OF FLOW OPTIONAL PRESSURE GAUGE DIRECTION OF FLOWMODEL 850XL SHUT-OFF VALVE MODEL 500XL TO HANDLE LOW DEMANDS (SET @ 65 PSI) DIRECTION OF FLOWMODEL 500XLFC TO HANDLE HIGH DEMANDS (SET @ 55 PSI) "Flow curves are based on a 50 psi pressure differential" Pipe Clamps Part No. Design Load 1 Design Load 2 Design Load 3 Approx. Wt./100 Lbs.(kN)Lbs.(kN) Lbs. (kN) Lbs. (kg) B2400-1/2 600 (2.67)150 (.67)105 (.47)23 (10.4) B2400-3/4 600 (2.67)150 (.67)105 (.47)26 (11.8) B2400-1 600 (2.67)150 (.67)120 (.53)31 (14.0) B2400-11/4 600 (2.67)150 (.67)120 (.53)36 (16.3) B2400-11/2 600 (2.67)150 (.67)120 (.53)39 (17.7) B2400-2 1200 (5.34)480 (2.14)180 (.80)93 (42.2) B2400-21/2 1200 (5.34)480 (2.14)180 (.80)106 (48.1) B2400-3 1200 (5.34)480 (2.14)300 (1.33)132 (59.9) B2400-31/2 1200 (5.34)480 (2.14)300 (1.33)151 (68.5) B2400-4 1500 (6.67)600 (2.67)450 (2.00)160 (72.6) B2400-5 1500 (6.67)600 (2.67)450 (2.00)192 (87.1) B2400-6 1500 (6.67)600 (2.67)450 (2.00)219 (99.3) B2400-8 2000 (8.90)800 (3.56)600 (2.67)297 (134.7) B2400-10 2000 (8.90)800 (3.56)600 (2.67)465 (210.9) B2400-12 2000 (8.90)800 (3.56)600 (2.67)560 (254.0) B2400-14 2000 (8.90)800 (3.56)600 (2.67)761 (345.2) B2400-16 2000 (8.90)800 (3.56)600 (2.67)861 (390.5) B2400-18 2000 (8.90)800 (3.56)600 (2.67)1297 (588.3) B2400-20 2000 (8.90)800 (3.56)600 (2.67)1426 (646.8) B2400-24 2000 (8.90)800 (3.56)600 (2.67)1682 (762.9) B2400 - Standard Pipe Strap (TOLCO Fig. 2STR) Cont. Bolt Size A B T C W Design Load 2 Design Load 3 Design Load 1 Pipe Size All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 92Pipe Hangers & Supports Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps Pipe Hangers & Supports93 Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap (Cooper B-Line B3181) Size Range:3/4" (20mm)thru 2" (50mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig. 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm)steel using (1) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Part number and CPVC pipe size. * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. C A B CPVC Max. Hanger Fastener Hex Approx. Pipe Size ABCSpacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 22-3/4 3/4"(20)27/16"(61.9)15/16"(33.3)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 22-1 1"(25)211/16"(68.3)17/16"(36.5)13/16"(30.2)6 (1,83)5/16"(7.9)9 (4.1) 22-11/4 11/4"(32)31/16"(77.8)15/8"(42.3)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 22-11/2 11/2"(40)35/16"(84.1)13/4"(44.4)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 22-2 2"(50)33/4"(95.2)21/8"(54.6)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8) Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 94Pipe Hangers & Supports Fig. 22L2 - One Hole Hanger/Restrainer for CPVC & Steel Pipe Size Range:3/4" (20mm)thru 2" (50mm)CPVC & steel pipe Material:Pre-Galvanized Steel Function:cULus Listed to perform as a hanger and restrainer for CPVC or IPS piping systems. The innovative design also allows for a preferred installation location close to a CPVC fitting without applying damaging compression forces on the pipe which could result in serious Mechanical ESC (Environmental Stress Cracking). Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm)steel using (1) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Installation Note:Comes in open position for easier installation. Because of multi – structural installation possibilities, specific fastener not included; see notes below for various applications. For Concrete Installation — UL requires a minimum test load of 340 lbs for CPVC hangers and 750 lbs for steel pipe hangers; verify anchors meet or exceed these requirements. For Wood Installation — Test results have shown that #14 x 1½” wood screws will support the required load for c UL us. For Steel Installation — Test results have shown that 1/4” x 1” (min. 20ga steel) Tek type screw will support required UL load. Finish:Pre-Galvanized Order By:Part number C A B CPVC or Steel Max. Hanger Max. Hanger Approx. Pipe Size ABCSpacing - CPVC Spacing - Steel Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) Ft. (m) Lbs. (kg) 22L2-3/4 3/4"(20)23/16"(55.6)15/16"(23.8)3/4"(19.0)51/2 (1.67)NA (NA)9 (4.1) 22L2-1 1"(25)21/2"(63.5)11/8"(28.6)3/4"(19.0)6 (1,83)12 (3.66)9 (4.1) 22L2-11/4 11/4"(32)213/16"(71.4)11/4"(31.7)3/4"(19.0)61/2 (1.98)12 (3.66)11 (5.0) 22L2-11/2 11/2"(40)31/8"(79.4)17/16"(36.5)3/4"(19.0)7 (2.13)15 (4.57)12 (5.4) 22L2-2 2"(50)39/16"(90.5)15/8"(41.3)3/4"(19.0)8 (2.44)15 (4.57)15 (6.8) TAB DOWN or TAB UP SPRINKLER HEAD HANGER/RESTRAINER FITTING OD MOUNTING SURFACE PIPE OD HANGER/RESTRAINER OFFSETDESIGN Tab Down or Tab Up Sprinkler Head Hanger/Restrainer Hanger/Restrainer Fitting OD Pipe OD Mounting Surface Offset Design Patent Pending Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap (Cooper B-Line B3182) Size Range:3/4" (20mm)thru 3" (80mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals:Underwriters Laboratories Listed in the USA (UL) and Canada (cUL)sizes 3/4" (20mm)thru 2" (50mm)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm)steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Part number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. A C B B CPVC Max. Hanger Fastener Hex Approx. Pipe Size ABCSpacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 23-3/4 3/4"(20)31/8"(79.4)19/16"(39.7)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 23-1 1"(25)33/8"(85.7)111/16"(42.9)13/16"(30.2)6 (1,83)5/16"(7.9)9 (4.1) 23-11/4 11/4"(32)43/16"(106.4)23/32"(53.1)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 23-11/2 11/2"(40)47/16"(112.7)27/32"(56.3)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 23-2 2"(50)47/8"(123.8)27/16"(61.9)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8) 23-21/2 21/2"(65)53/8"(136.5)211/16"(68.3)13/16"(30.2)Consult Factory 5/16"(7.9)22 (10.0) 23-3 3"(80)6"(152.4)3"(76.2)13/16"(30.2)Consult Factory 5/16"(7.9)25 (11.3)Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps Pipe Hangers & Supports95 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Side Mounted (Cooper B-Line B3183) Size Range:3/4" (20mm)thru 2" (50mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm)steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Part number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. C A B B CPVC Max. Hanger Fastener Hex Approx. Pipe Size ABCSpacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-3/4 3/4"(20)25/16"(58.7)15/32"(27.8)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 24-1 1"(25)25/8"(66.7)15/16"(33.3)13/16"(30.2)6 (1,83)5/16"(7.9)9 (4.1) 24-11/4 11/4"(32)3"(76.2)11/2"(38.1)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 24-11/2 11/2"(40)31/4"(82.5)15/8"(42.3)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 24-2 2"(50)311/16"(93.7)127/32"(43.6)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8)Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 96Pipe Hangers & Supports Fig. 27B - Speed Nut Size Range:— Fits screws supplied with all CPVC hangers. Material:— Steel Finish:— Pre-Galvanized (Zinc) Function:— To be used anywhere a screw cannot achieve full embedment due to thickness of wood structural material when installed. Fig. 27B allows full pull out load capacity of screws when installed to the standard screws supplied with all CPVC hangers (Fig. 22, 23, 24, 28, 28M, 29, and B3184). Hanger Application Hanger and Restraint Application Hanger and Restraint Application Fig. 27B (2) Required Fig. 27B (2) Required Fig. 27B (1) Required High Side of Hanger Application Fig. 27B (1) Required High Side of Hanger Application Hanger Application Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 98Pipe Hangers & Supports Fig. 28 - “Stand-Off” Hanger & Restrainer for CPVC Plastic Pipe Size Range:— 3/4"(20mm)through 2"(50mm) Material:— Steel, Pre-Galvanized Function:— Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand-Off" design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16"(7.9mm)extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge (1.024mm)with (2) 1/4" x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals:— Underwriters Laboratory Listed in the USA (UL)and Canada (cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8"(9.5mm)composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by:— Part number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 C A B Pipe Size ABCApprox. Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28-3/4 3/4"(20)31/32"(77.0)2"(50.8)31/2"(88.9)18 (8.1) 28-1 1"(25)35/16"(84.1)23/16"(55.6)31/2"(88.9)21 (9.5) 28-11/4 11/4"(32)35/8"(92.1)23/8"(60.3)31/2"(88.9)23 (10.4) 28-11/2 11/2"(40)4"(101.6)21/2"(63.5)31/2"(88.9)31 (14.0) 28-2 2"(50)41/2"(114.3)211/16"(68.3)35/8"(92.1)34 (15.4) Hanger Application Hanger and Restraint Application Fig. 27B (2) RequiredFig. 27B (1) Required High Side of Hanger ApplicationPipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps Pipe Hangers & Supports99 Fig. 28M - Offset Hanger & Restrainer for CPVC Plastic Pipe and IPS Pipe Size Range:3/4"(20mm)thru 2"(32mm) Material:Steel, Pre-Galvanized Function:Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the “stand-off” design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation • The “Stand-Off” design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16”(7.9mm)extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge (1.024mm)with (2) 1/4” x 1” tek type self drilling tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note:When installed in wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B speed nut to secure Approvals:Underwriters Laboratory Listed in the USA (UL)and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By:Part number and pipe size Patent #7,744,042 C A B Pipe Size A Hole Dia. B C Max Spacing* Approx. Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4"(20)2"(50.8)3/16"(4.8)35/16"(84.1)5’-6”(1676)9 (4.1) 28M-1 1"(25)21/8"(54.0)3/16"(4.8)31/2"(88.9)6’-0”(1829)12 (5.4) 28M-11/4 11/4"(32)25/16"(58.7)3/16"(4.8)31/2"(88.9)6’-6”(1981)13 (5.9) 28M-11/2 11/2"(49)27/16"(61.9)3/16"(4.8)37/8"(98.4)7’-0”(2133)14 (6.3) 28M-2 2"(50)25/8"(66.7)3/16"(4.8)47/16"(112.7)8’-0”(2438)15 (6.8) * Required per NFPA 13 for CPVC plastic pipe Hanger and Restraint Application Restraint Restraint Detail A Hanger Application Fig. 27B (2) Required Fig. 27B (1) Required High Side of Hanger Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 100Pipe Hangers & Supports Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range:Available in 3/4"(20mm)and 1"(25mm)pipe sizes Material:Pre-Galvanized Steel Function:Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2”(20mm)x 11/2”(20mm)from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1” hex head self-threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish:Pre-Galvanized Order By:Part number and pipe size. Patent Pending Install using a rechargeable electric drill fitted with a 5/16” (7.9mm)socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be “snapped” into hanger before or after installation of the screws to the mounting surface. “Thumb tab” may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. Double Offset Single Offset 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm)Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps Pipe Hangers & Supports101 Pipe Size Approx. Wt./100 Part No.in. (mm) lbs. (kg) 29-3/4 3/4"(20)17.0 (7.7) 29-1 1"(25)18.6 (8.4) B3184 - Offset Hanger for CPVC Plastic Pipe and IPS Pipe Size Range:3/4"(20mm)thru 2"(32mm) Material:Pre-Galvanized Steel Function:Designed to be used as a hanger for CPVC piping or steel piping where the “stand-off” design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • The “Stand-Off” design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self-threading screws furnished with product • cULus Listed as a hanger for fire sprinkler piping Installation Note:When installed in wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B speed nut to secure Approvals:Underwriters Laboratory Listed in the USA (UL)and Canada (cUL)3/4" (20mm)thru 2" (50mm)to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Order By:Part number and pipe size Patent # 7,744,042 H L Pipe Size CPVC LHMax. Hanger Fastener Hex Approx. Pipe Size Overall Overall Spacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) ft. (m) in. (mm) Lbs. (kg) B3184-3/4 3/4"(20)29/16"(65.1)41/4"(107.9)51/2 (1.67)5/16"(7.9)9.0 (4.1) B3184-1 1"(25)213/16"(71.4)41/2"(114.3)6 (1,83)5/16"(7.9)10.0 (4.5) B3184-11/4 11/4"(32)33/16"(81.0)45/8"(117.5)61/2 (1.98)5/16"(7.9)12.0 (5.4) B3184-11/2 11/2"(40)37/16"(87.3)5"(127.0)7 (2.13)5/16"(7.9)12.0 (5.4) B3184-2 2"(50)37/8"(98.4)5"(127.0)8 (2.44)5/16"(7.9)15.0 (6.8)Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 102Pipe Hangers & Supports KWIK-CLIP™ Series Size Range: 1/2" (15mm)thru 2" (50mm)Copper Tubing or CPVC pipe sizes 3/8" (9.5mm)thru 21/8" (54mm)O.D. Tubing sizes Material:Plastic - Black Features: • One piece design greatly reduces installation time. • No tools required to install. • Non-metallic design eliminates metal-to-metal contact; preventing galvanic corrosion. • Easily snaps into channel or onto 3/8”-16 all thread rod. • Meets UL2043 requirements for plenum rating; and UL94 HB flame rating. • Working temperature range of -40°F (-40°C)to +275°F (135°C). • BPIC and BPSC clips can be used with insulation, maintaining an unbroken barrier seal and eliminating sweating. • BPRC rod clip can be snapped onto 3/8”-16 all thread rod at any location. Order By:Part number. Rod Mount Clips BPRC Series Part Copper/CPVC Pipe O.D. Tubing Sch.40 Pipe Approx. Wt./100 Number in. (mm) in. (mm) in. (mm) lbs. (kg) BPRC062 1/2”(15)5/8”(15.9)--(--)1.2 (0.54) BPRC075 5/8”(16)3/4”(19.0)--(--)1.3 (0.59) BPRC087 3/4”(20)7/8”(22.2)1/2”(12.7)1.4 (0.63) BPRC100 --(--)1”(25.4)3/4”(19.0)1.5 (0.68) BPRC112 1”(25)11/8”(28.6)--(--)1.6 (0.72) BPRC125 --(--)11/4”(31.7)1”(25.4)1.7 (0.77) BPRC137 11/4”(32)13/8”(34.9)--(--)1.8 (0.81) BPRC150 --(--)11/2”(38.1)--(--)2.1 (0.95) BPRC162 11/2”(40)15/8”(41.3)--(--)2.3 (1.04) BPRC200 --(--)2”(50.8)--(--)2.5 (1.13) BPRC212 2”(50)21/8”(54.0)--(--)2.7 (1.22)Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps Pipe Hangers & Supports103 KWIK-CLIP™ Series - cont. Insert in channel.Twist into place.Lay tubing/pipe into clip. Snap clip closed. Part Copper/CPVC Pipe O.D. Tubing Sch.40 Pipe Approx. Wt./100 Number in. (mm) in. (mm) in. (mm) lbs. (kg) BPSC037 1/4”(6)3/8”(9.5)--(--)2.3 (1.0) BPSC050 3/8”(10)1/2”(12.7)--(--)2.6 (1.2) BPSC062 1/2”(15)5/8”(15.9)--(--)2.8 (1.3) BPSC075 5/8”(16)3/4”(19.0)--(--)3.3 (1.5) BPSC087 3/4”(20)7/8”(22.2)1/2”(12.7)3.9 (1.7) BPSC112 1”(25)11/8”(28.6)--(--)4.5 (2.0) BPSC137 11/4”(32)13/8”(34.9)--(--)5.0 (2.2) BPSC162 11/2”(40)15/8”(41.3)--(--)5.5 (12.5) Part Copper/CPVC Pipe O.D. Tubing Sch.40 Pipe Approx. Wt./100 Number in. (mm) in. (mm) in. (mm) lbs. (kg) BPIC062 1/2”(15)5/8”(15.9)--(--)2.9 (1.3) BPIC075 5/8”(16)3/4”(19.0)--(--)2.9 (1.3) BPIC087 3/4”(20)7/8”(22.2)1/2”(12.7)3.0 (1.4) BPIC100 --(--)1”(25.4)3/4”(19.0)3.2 (1.4) BPIC112 1”(25)11/8”(28.6)--(--)3.3 (1.5) BPIC125 --(--)11/4”(31.7)1”(25.4)3.4 (1.5) BPIC137 11/4”(32)13/8”(34.9)--(--)3.5 (1.6) BPIC150 --(--)11/2”(38.1)--(--)3.8 (1.7) BPIC162 11/2”(40)15/8”(41.3)--(--)4.0 (1.8) BPIC200 --(--)2”(50.8)--(--)4.2 (1.9) BPIC212 2”(50)21/8”(54.0)--(--)4.4 (2.0) Channel Mount Clips BPSC SeriesBPIC Series Pipe Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 104Pipe Hangers & Supports Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. B Date: 12/13 Document No. BF-975XL Product No. Model 975XL Model 975XL Reduced Pressure Principle Assembly Page 1 of 2AB G CD F E Options (Suffixes can be combined) - with full port QT ball valves (standard) L - less ball valves, male pipe thread U - with union ball valves MS - with integral relief valve monitor switch S - with bronze "Y" type strainer BMS - with battery operated monitor switch FDC - with fire hydrant connection; 2" only FT - with integral male 45° flare SAE test fitting TCU - with test cocks up V - with union swivel elbows (3/4" & 1") SE - with street elbows (3/4" & 1") Accessories Air gap (Model AG) Repair kits Thermal expansion tank (Mdl. XT) Soft seated check valve (Model 40XL) Shock arrester (Model 1250XL) QT-SET Quick Test Fitting Set Ball valve handle locks Application Designed for installation on water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Standards Compliance • ASSE® Listed 1013 • IAPMO® Listed • UL® Classified (less shut-off valves or with OS&Y valves • C-UL® Classified • CSA® Certified • AWWA compliant C511 • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California • NYC MEA 425-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Polymers Noryl™, NSF Listed Springs Stainless Steel, 300 series Features Sizes: 3/4", 1", 1-1/4", 1-1/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Relief Valve discharge port: 3/4” - 1” - 0.63 sq. in. 1 1/4” - 2” - 1.19 sq. in. Dimensions & Weights (do not include pkg.) ഌFlow Characteristics Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers’ instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12” (305mm) and a maximum of 30” (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. OUTDOOR INSTALLATIONINDOOR INSTALLATION (Shown w/optional BMS) Speci cations The Reduced Pressure Principle Backflow Preventer shall be shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Back- flow Preventer shall be a ZURN WILKINS Model 975XL. BATTERY MONITOR SWITCH* AIR GAP FITTING 12" MIN. 30" MAX. FLOOR DRAIN DIRECTION OF FLOW FLOOR CENTRAL STATION ALARM PANEL 12" MIN 30" MAX PROTECTIVE ENCLOSURE OPTIONAL WATER METER INLET SHUT-OFF AIR GAP DRAIN DIRECTION OF FLOW 0 20 40 60 805 10 15 20 0 50 100 150 200 2505 10 15 20 FLOW RATES (GPM)PRESSURE LOSS (PSIG) 69 PRESSURE LOSS (kpa) FLOW RATES (l/s) MODEL 975XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) 35 3/4" (20mm)1" (25mm)1 1/4" (32mm) 2" (50mm)103 15.812.69.56.33.25.03.82.521.26 1 1/2” (40mm) 137 RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems Page 1 of 6 FEBRUARY 2014 TFP443 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and in-stallation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are decora-tive, fast response, fusible solder sprin-klers designed for use in residential oc-cupancies such as homes, apartments, dormitories, and hotels. The Cover Plate/Retainer Assembly con-ceals the sprinkler operating compo-nents above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the concealed design of the Series LFII Residential Flat-Plate Con-cealed Pendent Sprinklers provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flex-ibility when cutting fixed sprinkler drops. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are in-tended for use in the following systems: • wet and dry pipe residential sprin-kler systems for one- and two-fam-ily dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprin-kler systems for residential occu-pancies up to and including four sto-ries in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Sprinklers have been designed with heat sensitiv-ity and water distribution characteristics proven to help in the control of residen-tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com-plete, the Protective Cap is removed and the Cover Plate/Retainer Assem-bly is installed. Removing the Protec-tive Cap is required for proper sprinkler performance. Dry Pipe System ApplicationThe Series LFII Residential Flat-Plate Concealed Pendent Sprinkler offers a laboratory approved option for design-ing dry pipe residential sprinkler sys-tems, whereas, most residential sprin-klers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Flat-Plate Con-cealed Sprinklers (TY2524) need not be increased over the number of design sprinklers (hydraulic design area) speci-fied for wet pipe sprinkler systems, as is customary for density/area sprinkler systems designed per NFPA 13, 13D, or 13R. Consequently, the Series LFII Residen-tial Flat-Plate Concealed Sprinklers (TY2524) offer the features of non-wa-ter filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems de-signed to NFPA 13, 13D, or 13R. NOTICE The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) described herein must be installed and maintained in compliance with this doc-ument and the applicable standards of the National Fire Protection Association, in addition to the standards of any au-thorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devic-es in proper operating condition. Con-tact the installing contractor or sprinkler manufacturer with any questions. Sprinkler Identification Number (SIN) TY2524 TFP443Page 2 of 6 3-3/16" DIA. (81,0 mm) 1/2"NPT 2-1/2" DIA.(63,5 mm) MOUNTINGSURFACE3/16"(4,8 mm) 1/8" GAP (3,2 mm) FACE OF SPRINKLER FITTING 7/8" (22,2 mm) 1-1/8" (28,6 mm) TIP DEFLECTOR INOPERATED POSITION 1/2" (12,7 mm) THREADED ADJUSTMENT SPRINKLER-SUPPORT CUPASSEMBLY OPERATEDSPRINKLER 1-7/8"±1/4" (47,6 mm ±6,4 mm) SPRINKLER-SUPPORT CUPASSEMBLY COVER-RETAINERASSEMBLY COVERPLATERETAINER DISPOSABLEPROTECTIVE CAP SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY COVER PLATE EJECTION SPRING RETAINER WITH THREAD DIMPLES SOLDER TAB SEALINGASSEMBLY COMPRESSION SCREW DEFLECTOR(OPERATEDPOSITION) SPRINKLERWRENCHINGAREA SOLDER LINK ELEMENT LEVER DEFLECTOR CAP BODY(1/2" NPT) SADDLE SUPPORTCUP WITHROLL FORMEDTHREADS GUIDEPIN GUIDE PIN HOUSING THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING WRENCHRECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) FIGURE 2 W-TYPE 18 SPRINKLER WRENCH FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE (TY2524) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP443Page 3 of 6 Technical Data ApprovalsUL and C-UL Listed The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. These Cover Plates and their part num-bers can be found in the Ordering Pro-cedure section at the end of this data sheet. For details on approvals, refer to the De-sign Criteria section. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK = 4.9 GPM/psi1/2 (70,6 LPM/bar1/2) Temperature RatingSprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment1/2 inch (12,7 mm) FinishesRefer to the Ordering Procedure section. Physical Characteristics Cover Plate/Retainer Assembly: Cover Plate.....................Copper Ejection Spring............Stainless Steel Retainer ........................Brass Sprinkler/Support Cup Assembly: Body...........................Brass Cap...........................Bronze Saddle..........................Brass Sealing Assembly. . . . . . . . . . . . . . Beryllium Nickel w/ TEFLON Soldered Link Halves . . . . . . . . . . . . . .Nickel Lever..........................Bronze Compression Screw. . . . . . . . . . . . . . . Brass Deflector.......................Bronze Guide Pin Housing . . . . . . . . . . . . . . . Bronze Guide Pins .....................Bronze Support Cup . . . . . . . . . . . . . . . . . . . . .Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup As-sembly. At this point, the Deflector, sup-ported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprinkler/Support Cup Assembly is comprised of two link halves that are soldered togeth-er with a thin layer of solder. When the rated temperature is reached, the sol-der melts and the two link halves sepa-rate, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) are UL and C-UL Listed for installation in ac-cordance with this section: Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, re-fer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept-able to the authority having jurisdiction. System TypePer the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling TypesSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin-kler flow rate are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the mini-mum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” spec-ified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis-charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover-age area • A minimum discharge of 0.1 gpm/ft2. over the “design area” comprised of the four most hydraulically demand-ing sprinklers for the actual coverage areas being protected by the four sprinklers The number of “design sprinklers” specified in NFPA 13 for wet pipe sys-tems is to be applied when designing dry pipe systems. Dry Pipe System Water DeliveryWhen using the Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (TY2524) in dry pipe sprinkler systems, the time for water delivery must not ex-ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water DistributionSprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensitivityInstall sprinklers relative to the ceiling mounting surface as shown in Figure 3. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler op-eration in a fire situation. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot ex-ceed the length of the coverage area (Table A) being hydraulically calculated (e.g., a maximum of 12 feet for a 12 ft. x 12 ft. coverage area or 20 feet for a 20 ft. x 20 ft. coverage area.) TFP443Page 4 of 6 Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)13 (49,2)7.0 (0,48)Smooth Ceilings 7/8 to 1-1/8 inches. Beamed Ceilings per NFPA 13D 13R, or 13 Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8 (2,4) 14 x 14(4,3 x 4,3)14(4,3)13 49,2)7.0 (0,48) 16 x 16(4,9 x 4,9)16(4,9)13(49,2)7.0 (0,48) 18 x 18(5,5 x 5,5)18(5,5)17 (64,3)12.0 (0,83) 20 x 20(6,1 x 6,1)20(6,1)20 (75,7)16.7 (1,15) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pres- sures are calculated using the nominal K-factor. Refer to “Hydraulic Design” in the Design Criteria section for details. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b) Ordinary Temp Rating 160°F (71°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) 12 x 12(3,7 x 3,7)12(3,7)15 (56,8)9.4 (0,65)Smooth Ceilings 7/8 to 1-1/8 inches. Beamed Ceilings per NFPA 13D 13R, or 13 Installed in beam 7/8 to 1-1/8 inches below bottom of beam Concealed 8 (2,4) 14 x 14(4,3 x 4,3)14(4,3)15 (56,8)9.4 (0,65) 16 x 16(4,9 x 4,9)16(4,9)16 (60,6)10,7 (0,74) 18 x 18(5,5 x 5,5)18(5,5)17 (64,3)12.0 (0,83) 20 x 20(6,1 x 6,1)20(6,1)21 (79,5)18,4 (1,27) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b) The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to “Hydraulic Design” in the Design Criteria section for details. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP443Page 5 of 6 Installation The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must be installed in accordance with this section: General InstructionsDamage to the Solder Link Element dur-ing installation can be avoided by han-dling the sprinkler by the Support Cup only; that is, do not apply pressure to the Solder Link Element (Figure 1). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min-imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insuf-ficient adjustment in the Cover Plate/Retainer Assembly by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers in the pendent position, with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe-thread sealant ap-plied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup-port Cup Assembly into the fitting. The W-Type 18 Wrench accepts a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec-tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. NOTICE As long as the protective Cap remains in place, the system is considered “Out Of Service”. Step 5. After the ceiling has been com-pleted with the 2-1/2 inch (63 mm) diam-eter hole and in preparation for install-ing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the sprinkler has been damaged and the deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate/Re-tainer Assembly until its flange contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mounting Cup or the Cover Plate/Retainer Assem-bly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with ths section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it con-trols, obtain permission to shut down the affected fire protection system from the proper authorities and notify all person-nel who may be affected by this action. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. The owner must assure that the sprin-klers are not used for hanging any ob-jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-opera-tion in the event of a fire or inadvertent operation may result. When properly installed, there is a nomi-nal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceil-ing, as shown in Figure 3. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does not seal off any of the air gap. Failure to do so may impair sprinkler operation. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Retainer. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi-fied or overheated sprinklers must be replaced. Care must be exercised to avoid dam-age to the sprinklers - before, during, and after installation. Sprinklers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in-spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the stan-dards of any other authorities having ju-risdiction. Contact the installing contrac-tor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP443Page 6 of 6 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product description and Part Number (P/N). Sprinkler/Support Cup AssemblySpecify: Series LFII (TY2524), K = 4.9 (70,6), Residential Flat-Plate Concealed Pendent Sprinkler without Cover Plate/Retainer Assembly, P/N 51-114-1-160 Cover Plate/Retainer AssemblySpecify: Series LFII (TY2524), K = 4.9 (70,6), Residential Flat-Plate Concealed Pendent Sprinkler Cover Plate/Retain-er Assembly with (specify) finish, P/N (specify): Ivory (RAL 1015)...........P/N 56-202-0-135 Beige (RAL 1001)..........P/N 56-202-2-135 Pure White (b) (RAL 9010) ...P/N 56-202-3-135 Signal White (a) (RAL 9003)..P/N 56-202-4-135 Grey White (RAL 9002) .....P/N 56-202-5-135 Brown (RAL 8028) .........P/N 56-202-6-135 Black (RAL 9005)..........P/N 56-202-7-135 Brushed Brass............P/N 56-202-8-135 Brushed Chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 (a) Previously known as Bright White. (b) Eastern Hemisphere sales only. Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler WrenchSpecify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 Worldwide Contacts www.tyco-fire.com Page 1 of 8 APRIL 2013 TFP461 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and in-stallation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Series LFII Dry Type Residential Horizontal Sidewall Sprinklers (TY2335) are dry type decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The Series LFII Dry Type Residential Horizontal Sidewall Sprinklers are typi-cally used for the following situations: • where sprinklers are required on dry pipe systems that are exposed to freezing temperatures; for example, horizontal sprinkler supply from un-heated portions of buildings • where sprinklers and/or a portion of the connecting piping are exposed to freezing temperatures; for example, horizontal sprinkler supply from wet systems into unheated areas • where sprinklers are used on systems that are seasonally drained to avoid freezing; for example, vacation areas The Series LFII Dry Type Residential Hori-zontal Sidewall Sprinklers are intended for use in Residential Sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D; residential sprinkler systems for residential occu-pancies up to and including four stories in height per NFPA 13R; or, sprinkler systems for the residential portions of any occupancy per NFPA 13. The recessed version is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjust-ment from the flush mounting surface position. The design of this escutcheon provides a level of flexibility in adjusting sprinkler supply connections. The Series LFII Dry Type Residential Horizontal Sidewall Sprinklers have been designed with heat sensitivity and water characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System ApplicationThe Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Horizontal Sidewall Sprinklers (TY2235) need not be increased over the number of design sprinklers (hydraulic design area) as speci-fied for wet pipe sprinkler systems, as is accustomed for density/area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi-dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFII Dry Type Residential Horizontal Sidewall Sprinklers (TY2335) described herein must be installed and maintained in compliance with this docu-ment and the applica ble standards of the National Fire Protection Associa-tion, in addition to the standards of any authorities hav ing jurisdiction. Failure to do so may impair the performance of these de vices. The owner is responsible for maintain ing their fire protection system and de vices in proper operating condition. The install-ing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2335 5/16"(7,9 mm) CENTERLINE OF WATERWAY (73,0 mm)2-7/8" DIA. 1-3/4" DIA.(44,5 mm) FITTINGSPRINKLER FACE OF SPRINKLER FITTING CRITERIA SECTION)(REFER TO DESIGN 2-3/16" ± 1/4"(55,6 ± 6,4 mm) 3-3/4" to 24" (95,3 to 609,6 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: SURFACEMOUNTING FACE OF FIGURE 3 RAPID RESPONSE SERIES LFII DRY TYPE RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLERS WITH STYLE 20 RECESSED ESCUTCHEON SEALINGPLUG WITH ASSEMBLY INLET SPRINGPLUGYOKE CASING SCREWCOMPRESSION BULBSEATTUBEGUIDE DEFLECTOR FRAME 3 mm INLETBAND BULB VENTHOLEBUSHING TUBEWATER FIGURE 1 RAPID RESPONSE SERIES LFII DRY TYPE RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLERS (TY2335) ASSEMBLY RECESS WRENCH FLAT WRENCH WITH SPRINKLERENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 5 W-TYPE 7 RECESSED SPRINKLER WRENCH WRENCH RECESS(USE END "A" ONLY) FIGURE 4 W-TYPE 6 SPRINKLER WRENCH 5/16"(7,9 mm) CENTERLINE OF WATERWAY FITTING SPRINKLERFACE OF 5-1/2" to 24" (139,7 to 609,6 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN 2-1/4" (57,2 mm)MINIMUM SURFACE MOUNTING MAXIMUM DEFLECTOR TO 6" (152,4 mm) FIGURE 2 RAPID RESPONSE SERIES LFII DRY TYPE RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLERS WITHOUT ESCUTCHEON TFP461 Page 2 of 8 TFP461 Page 3 of 8 Technical Data ApprovalsUL Listed For details on approval, refer to the Design Criteria section. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK = 4.4 GPM/psi1/2 (63,4 LPM/bar1/2) Inlet Thread Connections1 inch NPT or ISO 7-R1 Sprinkler Temperature Rating155°F/68°C FinishesNatural BrassSignal WhiteChrome-Plated Order LengthsMinimum: 3-3/4 inches (95,3 mm) Maximum: 24 inches (609,6 mm) Physical Characteristics Inlet ..................... BrassPlug ..................... BrassYoke ..............Stainless SteelCasing ...........Galvanized SteelInsert .................. BronzeBulb Seat ...........Stainless SteelBulb ......................GlassCompression Screw . . . . . . . . .BrassDeflector ................. BrassFrame ....................BrassGuide Tube .........Stainless SteelWater Tube .........Stainless SteelBushing . . . . . . . . . . . . . . . . . . .BrassPlug Spring .........Stainless SteelSealing Assembly . . . . . . . . Beryllium Nickel w/TEFLONEscutcheon . . . . . . . . . .Carbon Steel Operation When the TYCO RAPID RESPONSE Series LFII Dry Type Residential Horizontal Sidewall Sprinkler is in service, water is prevented from entering the assem-bly by the Plug with Sealing Assembly (Figure 1) in the Inlet of the Sprinkler. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb to release the Bulb Seat. The system’s water or air pressure is then able to unseat the Plug with Sealing As-sembly. The Plug Spring turns the Plug with Sealing Assembly aside, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Dry Type Residential Horizontal Sidewall Sprinklers (TY2335) are UL Listed for installation in accordance with this section. Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the criteria provided in this section, refer to the technical data sheet entitled Residential Sprinkler Design Guide (TFP490) for the manufacturer’s recommendations that may be acceptable to the local authority having jurisdiction. System TypesWet pipe, and dry pipe systems may be utilized. Hydraulic Design(NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rate are given in Table A or B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of “design sprinklers,” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” specified in NFPA 13D and 13R for wet pipe sys-tems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of required design sprinklers is the four most hydraulically demanding sprinklers. The minimum required dis-charge from each of the four sprinklers is the greater of the following: • flow rates listed in Table A or B as a function of temperature rating and the maximum allowable coverage area. • minimum discharge of 0.1 gpm/ft2 over the design area comprised of the four most hydraulically demanding sprin-klers for the actual coverage areas protected by four sprinklers. The number of “design sprinklers” speci-fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water DeliveryWhen using the Series LFII Residential Sprinklers (TY2335) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water DistributionSprinklers are to be located in accordance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensitivityThe sprinkler must be located relative to the mounting surface as shown in Figures 2 and 3. Sprinkler SpacingThe minimum lateral spacing between sprinklers is 8 feet (2,4 m). The maximum lateral spacing between sprinklers can-not exceed the length of the coverage area (refer to Table A or B) hydrauli-cally calculated (e.g., a maximum of 12 feet for a 12 ft. x 12 ft. coverage area or 18 feet for a 18 ft. x 20 ft. coverage area). Sprinkler FittingsThe following fittings may be used: • The 1 inch NPT outlet or run of a mal-leable or ductile iron threaded tee fittings that meet the dimensional re-quirements of ANSI B16.3 (Class 150) • The 1 inch NPT outlet or run of a cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125). For dry pipe systems, only use the side outlet of maximum 2-1/2 inch size reducing tees when locating the Series LFII Dry Type Residential Recessed Pendent Sprinklers directly below the branch line. Otherwise, use the con-figuration shown in Figure 7 to assure complete drainage from above the Se-ries LFII Sprinklers and the branch line. Do not install the Series LFII Dry Type Residential Recessed Pen-dent Sprinklers into elbow fittings. The Inlet of the sprinkler can con-tact the interior of the elbow, po-tentially damaging the Inlet seal. TFP461 Page 4 of 8 be sealed, in accordance with the Na-tional Fire Protection Association. Due to temperature differences between the two areas, the potential for the forma-tion of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in Technical Data Sheet TFP591 and shown in Figures 6 through 8, can provide the recommended seal. Installation The TYCO RAPID RESPONSE Series LFII Dry Type Residential Horizontal Sidewall Sprinklers must be installed in accordance with this section. General InstructionsThe Series LFII Dry Type Residential Horizontal Sidewall Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. For other important require-ments regard ing piping design and sealing of the clearance space around the Sprinkler Casing, refer to the Design Criteria section. Do not install any bulb type sprinkler if the Bulb is cracked or there is a loss of liquid from the Bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a min-imum-to-maximum torque of 20 to 30 ft.-lbs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet or Frame with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install horizontal sidewall sprin-klers only in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceil-ing. The word TOP on the Deflector is to face towards the ceiling. Step 2. With a non-hardening pipe-thread sealant such as Teflon tape applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. Wrench-tighten the sprinkler using a pipe wrench on the Inlet Band or the Casing (Figure 1), or using the W-Type 6 or W-Type 7 Sprinkler Wrench as follows: Only use the configuration in Fig-ure 6 where the sprinkler fitting and water-filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Series LFII Sprinkler has the minimum exposure length per Figure 8. Refer to the Ex-posure Length section and Table C. • The 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee in wet pipe systems only • The 1 inch NPT CPVC outlet of a 1” x 1” x 1” NPT Sprinkler Head Adapter Tee (P/N 80249) in wet systems only • The 1 inch NPT CPVC outlet of a 1” x 1” NPT Female Adapter (P/N 80145) in wet systems only • The 1 inch NPT outlet of a 1” x 1” x 1” NPT CPVC Sprinkler Head Adapter Tee (P/N 80259) in either wet or dry pipe systems NOTICE Do not install the Series LFII Dry Type Residential Horizontal Sidewall Sprin-klers into any other type fitting without first consulting the Technical Services Department. Failure to use the appro-priate fitting may result in the following: • failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug. • insufficient engagement of the in-let pipe threads with consequent leakage. DrainageBranch, cross, and feed-main piping connected to Series LFII Dry Type Resi-dential Sprinklers and subject to freezing temperatures must be pitched to allow proper drainage, in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. Exposure LengthWhen using Series LFII Dry Type Resi-dential Horizontal Sidewall Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the con-necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 8 for an example. Clearance SpaceWhen connecting an area subject to freezing and an area containing a wet-pipe sprinkler system, the clearance space around the sprinkler barrel of Dry Type Residential Sprinklers must • For plain-barrel horizontal sidewall sprinklers, apply the Wrench Recess End “A” of the W-Type 6 Sprinkler Wrench (Figure 4) to the Wrench Flat. • For recessed horizontal sidewall sprin-klers, apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat (Figure 5). If sprinkler removal is necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or applying a ceiling finish, slide the Style 20 Recessed Escutcheon Closure over the sprinkler. Push the closure over the mounting plate until its flange contacts the wall. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Dry Type Residential Horizontal Sidewall Sprinklers (TY2335) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of a Recessed Escutcheon Plate or a Domed Concealed Cover Plate to cover a clearance hole can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. A Vent Hole is provided in the Bulb Seat (Figure 1) to indicate if the Series LFII Dry Type Residential Horizontal Sidewall Sprinkler is remaining dry. Evi dence of leakage from the Vent Hole indicates potential leakage past the Plug with Seal-ing Assembly and the need to remove the sprinkler to determine the cause of leakage (for example, an improper installation or an ice plug). Close the fire protection system control valve and drain the system before removing the sprinkler. Maximum Coverage Area (a, b) Width x Length Ft. x Ft. (m x m) Maximum Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(c, d) 155°F (68°C) Flow GPM (L/min) Pressure PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60) 4 to 6 Inches Recessed or Plain Barreled 8 (2,4) 14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)10.1 (0,70) 16 x 16 (4,9 x 4,9)16 (4,9)17 (64,3)14.9 (1,03) 16 x 18 (4,9 x 5,5)16 (4,9)19 (71,9)18.6 (1,28) 16 x 20 (4,9 x 6,1)16 (4,9)25 (94,6)32.3 (2.23) 12 x 12 (3,7 x 3,7)12 (3,7)15 (56,8)11.6 (0,80) 6 to 12 Inches 14 x 14 (4,3 x 4,3)14 (4,3)15 (56,8)11.6 (0,80) 16 x 16 (4,9 x 4,9)16 (4,9)19 (71,9)18.6 (1,28) 16 x 18 (4,9 x 5,5)16 (4,9)20 (75,7)20.7 (1,43) 16 x 20 (4,9 x 6,1)16 (4,9)25 (94,6)32.3 (2.23) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) This dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of the sprinkler). (c) The requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section for details. (d) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII DRY TYPE HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 HYDRAULIC DESIGN CRITERIA TFP461 Page 5 of 8 Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the in-spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protec tion Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Con-tact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom-mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local require-ments and/or national codes. Maximum Coverage Area (a, b) Width x Length Ft. x Ft. (m x m) Maximum Spacing Ft. (m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure(c, d) 155°F (68°C) Flow GPM (L/min) Pressure PSI (bar) Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)8.7 (0,60) 4 to 6 inches Recessed or Plain Barreled 8 (2,4) 14 x 14 (4,3 x 4,3)14 (4,3)16 (60,6)13.2 (0,91) 16 x 16 (4,9 x 4,9)16 (4,9)17 (64,3)14.9 (1,03) 16 x 18 (4,9 x 5,5)16 (4,9)N/A N/A 16 x 20 (4,9 x 6,1)16 (4,9)N/A N/A 12 x 12 (3,7 x 3,7)12 (3,7)15 (56,8)11.6 (0,80) 6 to 12 Inches 14 x 14 (4,3 x 4,3)14 (4,3)16 (60,6)13.2 (0,91) 16 x 16 (4,9 x 4,9)16 (4,9)19 (71,9)18.6 (1,28) 16 x 18 (4,9 x 5,5)16 (4,9)N/A N/A 16 x 20 (4,9 x 6,1)16 (4,9)N/A N/A (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) This dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of the sprinkler). (c) The requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section for details. (d) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII DRY TYPE HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 HYDRAULIC DESIGN CRITERIA TFP461 Page 6 of 8 (SEE DESIGN CRITERIASECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 BOOT HEATEDAREA FIGURE 8 EXPOSURE LENGTH PLUG OUTLET FITTING(SEE DESIGN CRITERIASECTION) SPRINKLER DSB-2 BOOT TO DRYSYSTEM AREA SUBJECTTOFREEZING FIGURE 7 SPRINKLER FITTING IN UNHEATED AREA PLUGOUTLET TO WETSYSTEM FITTING(SEE DESIGN CRITERIASECTION) SPRINKLER DSB-2 BOOT HEATED AREA FIGURE 6 SPRINKLER FITTING IN HEATED AREA TFP461 Page 7 of 8 Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(a) 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length, Inches (mm)(b) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C)4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C)14 (355)4 (100)1 (25) -20°F (-29°C)14 (355)6 (150)3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C)20 (510)10 (255)6 (150) -60°F (-51°C)20 (510)10 (255)6 (150) Notes: (a) For protected area temperatures that occur between values listed above, use the next cooler temperature. (b) These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C MINIMUM RECOMMENDED LENGTHS OF EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS TFP461 Page 8 of 8 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TABLE D RAPID RESPONSE SERIES LFII DRY TYPE RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLERS PART NUMBER SELECTION P/N* 63 – XXX – X – XXX SIN 12 Horizontal Sidewall with Recessed Escutcheon TY2335 (Figure 3 ) 13 Horizontal Sidewall without Escutcheon TY2335 (Figure 2) ORDER LENGTH (EXAMPLES) 055 5.50” 082 8.25” 180 18.00” 187 18.75” 240 24.00” SPRINKLER RECESSED ESCUTCHEON 2 Natural Brass Brass Plated 4 Signal White (RAL9003)Signal White (RAL9003) 9 Chrome Plated ChromeTEMPERATURE RATING 1 155°F (68°C) Note* Use Prefix “I” for ISO 7-R1 Inlet Thread Connection; for example, I-63-121-9-180. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product name and Part Number (P/N). Refer to the Price List for a com-plete listing of Part Numbers. Horizontal Sidewall Sprinkler AssemblySpecify the following information: • Series LFII Dry Type Residential Hori-zontal Sidewall Sprinkler (TY2335) • with Recessed Escutcheon or without Escutcheon • 4.4 K-factor • 155°F (68°C) Temperature Rating • Sprinkler Finish • Escutcheon Finish (if applicable) • Order Length (value from Figure 2 or 3) • Inlet Thread Connection (1 Inch NPT or ISO 7-R1) • P/N (from Table D) Separately Ordered Sprinkler WrenchSpecify: W-Type 6 Sprinkler Wrench (Figure 4), P/N 56-000-6-387 Specify: W-Type 7 Recessed Sprinkler Wrench (Figure 5), P/N 56-850-4-001 Separately Ordered EscutcheonSpecify: Style 20 recessed Escutcheon with (specify*) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems Page 1 of 6 APRIL 2013 REV A TFP410 Worldwide Contacts www.tyco-fire.com General Description The TYCO RAPID RESPONSE Series LFII Residential Horizontal Sidewall Sprinklers (TY1334) are decorative, fast response, frangible bulb sprinklers designed for use in residential occupan-cies such as homes, apartments, dormi-tories, and hotels. When aesthetics and optimized flow characteristics are the major consideration, the Series LFII Residential Sidewall Sprinklers (TY1334) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: • wet and dry pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D • wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R • wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen-tial fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System ApplicationThe Series LFII Residential Horizontal and Recessed Horizontal Sidewall Sprinklers offers a laboratory approved option for designing dry pipe residen-tial sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Horizontal Sidewall Sprinklers (TY1334) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprin-klers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFII Residential Horizontal Sidewall Sprinklers described herein must be installed and maintained in compliance with this document and the applicable standards of the National Fire Protection Association, in addition to the standards of any authorities having juris-diction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu-facturer should be contacted with any questions. IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Sprinkler Identification Number (SIN) TY1334 TFP410 Page 2 of 6 7/16" (11,1 mm) MAKE-IN NOMINAL SURFACE ESCUTCHEON PLATE SEATING Sealing Assembly-3 5 4 * 6 Compression Screw of Deector.is indicated on top Temperature rating Bulb Deector-- - * 1 Components: 2 Button Assembly Frame- -TOP(57,2 mm) 2-1/4" (41,3 mm) 1-5/8" *6 4 5 3 2 1 2-7/8" DIA. (73,0 mm) RECESSED ESCUTCHEON STYLE 20 FLATS WRENCH CENTERLINE OF WATERWAY 1/2" NPT BOSS END-OF- DEFLECTOR TOP-OF- DEFLECTOR 7/16" (11,1 mm) FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY1334) 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) MOUNTING PLATE TY1334 MOUNTINGSURFACE CLOSURE (73,0 mm) 1/2" (12,7 mm) (57,2 mm)2-1/4" DIA. 1/4" (6,4 mm) 1/8"(3,2 mm) (11,1±3,2 mm) SPRINKLER FITTING FACE OF 7/16±1/8" 2-7/8" DIA. BOSS END-OF- DEFLECTOR TOP-OF- DEFLECTOR 7/16"(11,1 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY1334) WRENCH RECESS(END "A" USED FOR TY1334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH RECESSWRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP410 Page 3 of 6 Technical Data ApprovalsUL Listed for use with wet pipe and dry pipe systems NSF Certified to NSF/ANSI 61 C-UL Listed for use only with wet pipe systems NYC Approved under MEA 44-03-E For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure175 psi (12,1 bar) Discharge CoefficientK=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) Temperature Rating155°F (68°C) or 175°F (79°C) FinishesSignal or Pure WhiteChrome Plated Natural Brass Physical CharacteristicsFrame ....................BrassButton ...................CopperSealing Assembly . . . . . . . . Beryllium Nickel w/TEFLONBulb (3 mm) . . . . . . . . . . . . . . . . GlassCompression Screw . . . . . . . .BronzeDeflector .................Copper Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Horizontal and Recessed Horizontal Sidewall Sprinklers (TY1334) are UL and C-UL Listed for installation in accordance with the following criteria. Residential Sprinkler Design GuideWhen conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur-er’s recommendations that may be acceptable to the local authority having jurisdiction. System TypesPer the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling TypesSmooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R)For systems designed to NFPA 13D or NFPA 13R, the minimum re quired sprinkler flow rates are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of “design sprinklers” as specified in NFPA 13D or NFPA 13R. The number of “design sprinklers” specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13)For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rat-ing and the maximum allowable coverage area • A minimum discharge of 0.1 gpm/ft2 over the “design area” comprised of the four most hydraulically demand-ing sprinklers for actual coverage ar-eas protected by the four sprinklers The number of “design sprinklers” specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water DeliveryWhen using the Series LFII Residential Horizontal Sidewall Sprinklers (TY1334) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water DistributionSprinklers are to be located in accor-dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the TYCO Technical Data Sheet TFP490. Operational SensitivityThe sprinklers are to be installed with an end-of-deflector-boss to wall distance of 1-1/4 to 6 inches. In addition the top-of-deflector-to-ceiling distance is to be within the range (Tables A and B) being hydraulically calculated. Sprinkler SpacingThe minimum spacing between sprin-klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the width of the coverage area (Tables A and B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area.). TFP410 Page 4 of 6 TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL HORIZONTAL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY1334) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Max. Coverage Area (a) Width x Length (d) Ft. x Ft. (m x m) Max. Spacing Ft. (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7)12 (3,7)12 (45,4)8.2 (0,57)12 (45,4)8.2 (0,57) 4 to 6 inches Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14 (4,3 x 4,3)14 (4,3)14 (53,0)11.1 (0,77)16 (60,6)14.5 (1,00) 16 x 16 (4,9 x 4,9)16 (4,9)16 (60,6)14.5 (1,00)16 (60,6)14.5 (1,00) 16 x 18 (4,9 x 5,5)16 (4,9)19 (71,9)20.5 (1,41)19 (71,9)20.5 (1,41) 16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)30.0 (2,07)23 (87,1)30.0 (2,07) 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)9.6 (0,66)13 (49,2)9.6 (0,66) 6 to 12 inches 14 x 14 (4,3 x 4,3)14 (4,3)17 (64,3)16.4 (1,13)18 (68,1)18.4 (1,27) 16 x 16 (4,9 x 4,9)16 (4,9)18 (68,1)18.4 (1,27)18 (68,1)18.4 (1,27) 16 x 18 (4,9 x 5,5)16 (4,9)21 (79,5)25.0 (1,72)21 (79,5)25.0 (1,72) 16 x 20 (4,9 x 6,1)16 (4,9)26 (98,4)38.3. (2,64)26 (98,4)38.3. (2,64) (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler). TFP410 Page 5 of 6 TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL HORIZONTAL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY1334) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Max. Coverage Area (a) Width x Length (d) Ft. x Ft. (m x m) Max. Spacing Ft. (m) DRY PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7)12 (3,7)12 (45,4)8.2 (0,57)12 (45,4)8.2 (0,57) 4 to 6 inches Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8(2,4) 14 x 14 (4,3 x 4,3)14 (4,3)16 (60,6)14.5 (1,00)16 (60,6)14.5 (1,00) 16 x 16 (4,9 x 4,9)16 (4,9)16 (60,6)14.5 (1,00)16 (60,6)14.5 (1,00) 16 x 18 (4,9 x 5,5)16 (4,9)19 (71,9)20.5 (1,41)N/A N/A 16 x 20 (4,9 x 6,1)16 (4,9)23 (87,1)30.0 (2,07)N/A N/A 12 x 12 (3,7 x 3,7)12 (3,7)13 (49,2)9.6 (0,66)13 (49,2)9.6 (0,66) 6 to 12 inches 14 x 14 (4,3 x 4,3)14 (4,3)18 (68,1)18.4 (1,27)18 (68,1)18.4 (1,27) 16 x 16 (4,9 x 4,9)16 (4,9)18 (68,1)18.4 (1,27)21 (79,5)25.0 (1,72) 16 x 18 (4,9 x 5,5)16 (4,9)21 (79,5)25.0 (1,72)21 (79,5)25.0 (1,72) 16 x 20 (4,9 x 6,1)16 (4,9)N/A N/A N/A N/A (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. (d) The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler). TFP410 Page 6 of 6 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 Installation The TYCO RAPID RESPONSE Series LFII Residential Horizontal and Recessed Horizontal Sidewall Sprinklers (TY1334) must be installed in accordance with this section. General InstructionsDo not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft. lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Horizontal Sidewall SprinklersThe Series LFII Residential Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. Step 1. Install horizontal sidewall sprin-klers in the horizontal position with their centerline of waterway perpendicular to the backwall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling with the front edge of the Deflector parallel to the ceiling. Step 2. With pipe-thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Horizontal Sidewall SprinklersThe Series LFII Residential Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed hori-zontal sidewall sprinklers in the hori-zontal position with their centerline of waterway perpendicular to the backwall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Horizontal and Recessed Horizontal Sidewall Sprinklers (TY1334) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin-klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-operation in the event of a fire or inad-vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom-mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler AssemblySpecify: Series LFII (TY1334), K=4.2, Residential Horizontal Sidewall Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify). 155°F (68°C) Natural Brass . . . . . . . . . . . . . . . .P/N 51-211-1-155Pure White (RAL9010)* ........P/N 51-211-3-155Signal White (RAL9003) .......P/N 51-211-4-155Chrome Plated ..............P/N 51-211-9-155 175°F (79°C) Natural Brass . . . . . . . . . . . . . . . .P/N 51-211-1-175Pure White (RAL9010)* ........P/N 51-211-3-175Signal White (RAL9003) .......P/N 51-211-4-175Chrome Plated . . . . . . . . . . . . . . P/N 51-211-9-175 *Eastern Hemisphere sales only. Recessed EscutcheonSpecify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*). *Refer to Technical Data Sheet TFP770. Sprinkler WrenchSpecify W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Worldwide Contacts www.tyco-fire.com Page 1 of 10 OCTOBER 2013 TFP171 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and installation can permanently dam-age a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen-dent, and Recessed Pendent Sprin-klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan-cies such as banks, hotels, and shop-ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applica-ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli-cable approval agencies, the testing is not representative of all possible cor-rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit-ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech-nical Data Sheet TFP780. NOTICE The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica-ble standards of the National Fire Pro-tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain-ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2˝ NPT TY1231: Pendent 2.8K, 1/2˝ NPT TY2131: Upright 4.2K, 1/2˝ NPT TY2231: Pendent 4.2K, 1/2˝ NPT TY3131: Upright 5.6K, 1/2˝ NPT TY3231: Pendent 5.6K, 1/2˝ NPT TY4131: Upright 8.0K, 3/4˝ NPT TY4231: Pendent 8.0K, 3/4˝ NPT TY4831: Upright 8.0K, 1/2˝ NPT TY4931: Pendent 8.0K, 1/2˝ NPT TFP171 Page 2 of 10 *** * ** * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN ESCUTCHEONPLATE SEATINGSURFACE STYLE 10 or 20 RECESSED ESCUTCHEON Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. WRENCH FLATS 2-3/16" (55,6 mm) SealingAssembly CompressionScrew12ButtonFrame-- Bulb 3 - 4 -6 -Deector 5 - 7 Bushing- 1/2" NPT 6 5 1 4 2 3 7 2-7/8" (73,0 mm) DIA. 2-1/4" (57,2 mm) 1-9/16"(39,7 mm) ** *** * * UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION 7/16"(11,1 mm)NOMINALMAKE-IN ESCUTCHEONPLATE SEATINGSURFACE STYLE 10 or 20RECESSEDESCUTCHEON Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. WRENCHFLATS 2-3/16"(55,6 mm) 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) SealingAssembly CompressionScrew 1/2" NPT Frame Button-2 1 - Deector6- 2-7/8" (73,0 mm) DIA.6 4 5 2 1 3 4 -Bulb 3 -5 - FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 *** ** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN ESCUTCHEONPLATE SEATINGSURFACE STYLE 10 or 20 RECESSED ESCUTCHEON Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. 2-7/8" (73,0 mm) DIA.1/2" NPT 12 ButtonFrame-- Bulb4-6 -Deector 5 6 4 2 3 1 3 -5 - WRENCHFLATS 2-3/16"(55,6 mm) 2-3/16"(55,6 mm) 1-1/2" (38,1 mm) SealingAssembly CompressionScrew *** ** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 1/2" (12,7 mm) NOMINAL MAKE-IN ESCUTCHEONPLATE SEATINGSURFACE STYLE 30 or 40 RECESSED ESCUTCHEON Pipe thread connections perISO 7-1 can be provided onspecial request. Temperature ratingis indicated onDeector. WRENCHFLATS SealingAssembly CompressionScrew 3/4" NPT 12 ButtonFrame-- Bulb 3 - 4 -6 -Deector 5 - 5 6 4 2 3 1 2-7/8" (73,0 mm) DIA. 2-5/16"(58,7 mm) 1-9/16" (39,7 mm) 2-1/4"(57,2 mm) FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT TFP171 Page 4 of 10 Technical Data ApprovalsUL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature RatingRefer to Table A and B. FinishesSprinkler: Refer to Table D. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical CharacteristicsFrame...................BronzeButton..............Brass/CopperSealing Assembly. . . . . . . . .Beryllium Nickel w/TEFLONBulb ......................GlassCompression Screw. . . . . . . . BronzeDeflector...........Copper/BronzeBushing (K=2.8) . . . . . . . . . . . Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen-dent, and Recessed Pendent Sprinklers are intended for fire protection sys-tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require-ments of FM’s Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica-ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General InstructionsDo not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin-kler held horizontally, a small air bub-ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint shold be obtained by applying a min-imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch-eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent SprinklersThe Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin-klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer-ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprin-kler wrench flats. Series TY-FRB Recessed Pendent SprinklersThe Series TY-FRB Recessed Pendent Sprinklers must be installed in accor-dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica-ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure * ** ** * * PENDENTUPRIGHT CROSS SECTION 2-1/4"(57,2 mm) 1-9/16" (39,7 mm)2-3/16"(55,6 mm) Sealing Assembly WRENCHFLATS CompressionScrew Pipe thread connectionsper ISO 7-1 can beprovided on specialrequest. Temperature rating isindicated on Deector. CEILING PLATESEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE-IN 12 ButtonFrame-- Bulb 3 - 4 - 6 -Deector 5 - 1/2" NPT 5 6 4 2 3 1 FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT TFP171 Page 5 of 10 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED SIGNAL*** WHITE 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F (57°C)Orange 1, 2, 3, 4 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY1231)* Figure 6 135°F (57°C)Orange 1, 2, 4 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green RECESSED PENDENT (TY1231)** Figure 7 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F (57°C)Orange 1, 2 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY2231)* Figure 8 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green RECESSED PENDENT (TY2231)** Figure 9 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green NOTES:1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED SIGNAL*** WHITE LEAD COATED 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C)Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY3231)* Figure 10 135°F (57°C)Orange 1, 2, 4, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY3231)** Figure 11 135°F (57°C)Orange 1, 2, 3, 4, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C)Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY4231)* Figure 12 135°F (57°C)Orange 1, 2, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C)Orange 1, 2, 3, 5 N/A 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C)Orange 1, 2, 4, 5, 6 1, 2, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue NOTES:1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E.6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leak-ing or exhibiting visible signs of corro-sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other-wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam-age to the sprinklers - before, during, and after installation. Sprinklers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa-tion (e.g., NFPA 25), in addition to the standards of any other authorities hav-ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam-age to the sprinklers -before, during, and after installation. Sprinklers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin-kler condition and the long-term integ-rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS CHROME PLATED SIGNAL WHITE LEAD COATED 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131)175 PSI (12,1 BAR)N/A RECESSED PENDENT (TY1231) 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131)175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) RECESSED PENDENT (TY3231)N/A 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131)175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4231)N/A 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831)175 PSI (12,1 BAR)175 PSI (12,1 BAR) NOTES:1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE TFP171 Page 8 of 10 2-1/4" DIA.(57,2 mm) 2-7/8" DIA.(73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTINGPLATE 1/8" (3,2 mm) SERIES TY-FRBCLOSURE 13/16" (20,6 mm) 1-5/16" (33,3 mm) 1/4" (6,4 mm) 3/4" (19,1 mm)5/8±1/4"(15,9±6,4 mm)1/2±1/8"(12,7±3,2 mm)2-1/4" DIA.(57,2 mm) 2-7/8" DIA.(73,0 mm) MOUNTINGSURFACE CLOSURE FACE OF SPRINKLER FITTING 1-1/16" (27,0 mm) 1-5/16" (33,3 mm) MOUNTINGPLATE 1/8" (3,2 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) SERIES TY-FRB 1/2±1/8" (12,7±3,2 mm)2-1/4" DIA.(57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTINGSURFACE FACE OFSPRINKLERFITTING MOUNTINGPLATE 1/8"(3,2 mm) SERIESTY-FRBCLOSURE 1" (25,4 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) 2-1/4" DIA.(57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTINGSURFACE FACE OFSPRINKLERFITTING MOUNTINGPLATE 1/8"(3,2 mm) SERIESTY-FRB 5/8±1/4" (15,9±6,4 mm) CLOSURE 3/4" (19,1 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 3/4" (19,1 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 2-1/4" DIA.(57,2 mm) 2-7/8" DIA.(73,0 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING MOUNTINGPLATE 1/8" (3,2 mm) SERIES TY-FRB 5/8±1/4"(15,9±6,4 mm) CLOSURE 3/4" (19,1 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 3/4" (19,1 mm)1/2±1/8"(12,7±3,2 mm)2-1/4" DIA.(57,2 mm) 2-7/8" DIA.(73,0 mm) MOUNTINGSURFACE FACE OF SPRINKLER FITTING MOUNTINGPLATE 1/8" (3,2 mm) SERIES TY-FRBCLOSURE 1" (25,4 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 1/2" (12,7 mm) 2-1/4" DIA.(57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE FACE OFSPRINKLERFITTING MOUNTINGPLATE 1/8"(3,2 mm) SERIES TY-FRB 5/8±1/4" (15,9±6,4 mm) CLOSURE 1-5/16" (33,3 mm) 13/16" (20,6 mm) 3/4" (19,1 mm) 1/4" (6,4 mm)1/2±1/8" (12,7±3,2 mm)2-1/4" DIA.(57,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTINGSURFACE FACE OFSPRINKLERFITTING MOUNTINGPLATE 1/8"(3,2 mm) SERIES TY-FRBCLOSURE 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) 1/2" (12,7 mm) 1/4" (6,4 mm) WRENCHRECESS PUSH WRENCHIN TO ENSUREENGAGEMENTWITH SPRINKLERWRENCHING AREA WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 14 W-TYPE 6 SPRINKLER WRENCH FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP171 Page 10 of 10 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. P/N 57 – XXX – X – XXX * Eastern Hemisphere sales only. ** Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera-ture rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon:Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler WrenchSpecify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 * Refer to Technical Data Sheet TFP770 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)* 4 SIGNAL WHITE (RAL9003) 5 JET BLACK (RAL9005)** 7 LEAD COATED 9 CHROME PLATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) SIN 330 2.8K UPRIGHT (1/2”NPT)TY1131 331 2.8K PENDENT (1/2”NPT)TY1231 340 4.2K UPRIGHT (1/2”NPT)TY2131 341 4.2K PENDENT (1/2”NPT)TY2231 370 5.6K UPRIGHT (1/2”NPT)TY3131 371 5.6K PENDENT (1/2”NPT)TY3231 390 8.0K UPRIGHT (3/4”NPT)TY4131 391 8.0K PENDENT (3/4”NPT)TY4231 360 8.0K UPRIGHT (1/2”NPT)TY4831* 361 8.0K PENDENT (1/2”NPT)TY4931* TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 90 www.tolco.com Revision 3/1/2007 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 32 www.tolco.com Revision 9/1/2006 Size Range — (Fig. 6) 1/2" thru 20" pipe (Fig. 6F) 1/2" thru 21⁄2" copper tubing (Fig. 6PVC) 1/2" thru 6" pipe Material — Carbon Steel Insulation Material — (Fig. 6F) 3/16" felt. Function — Used for supporting vertical piping. Approvals — Underwriters’ Laboratories Listed in the USA (UL), Canada (cUL) 1/2" - 8". Factory Mutual Engineering Approved, 3/4" thru 8". Conforms to Federal Specification WW-H-171E, Type 8, 3/4" thru 20" and Manufacturers Standardization Society SP-69, Type 8. Maximum Temperature — 650°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — (Fig. 6 and Fig. 6PVC) pipe size and finish. (Fig. 6F) copper tube size and finish. (Fig. 6F is available for Iron Pipe Size, consult factory. Fig. 6FFig. 6PVC Fig. 6 Fig. 6 - Riser Clamp Fig. 6F - Felt Lined Riser Clamp Fig. 6PVC - PVC Coated Riser Clamp Dimensions • Weights Pipe Max. Rec. Approx. Size A B C Bolt Size Load Lbs. Wt./100 1/2 91⁄4 1/2 11⁄8 3/8 255 144 3/4 91⁄4 1/2 11⁄8 3/8 255 144 1 99⁄16 1/2 11⁄4 3/8 255 147 11⁄4 911⁄16 1/2 13⁄8 3/8 255 150 11⁄2 103⁄8 1/2 11⁄2 3/8 255 153 2 103⁄4 1/2 2 3/8 255 165 21⁄2 11 5/8 21⁄4 3/8 390 228 3 12 5/8 3 3/8 530 246 31⁄2 13 5/8 31⁄4 1/2 670 264 4 131⁄2 3/4 33⁄8 1/2 810 347 5 141⁄2 3/4 43⁄8 1/2 1160 385 6 151⁄8 7/8 47⁄8 1/2 1570 564 8 181⁄2 1 53⁄4 5/8 2500 1017 10 201⁄4 1 71⁄4 5/8 2500 1138 12 223⁄4 1 81⁄4 5/8 2700 1759 14 24 11⁄8 9 5/8 2700 1922 16 26 11⁄8 101⁄4 3/4 2900 3245 18 28 11⁄4 111⁄2 3/4 2900 3372 20 30 13⁄8 121⁄2 3/4 2900 3499 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 60 www.tolco.com Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11⁄4" Throat Openings Size Range — (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material — Carbon Steel with hardened cup point set screw and jam nut Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11⁄4" (Fig. 66). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bot- tom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish Fig. 65 Patent #4,570,885 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13⁄16 3/4 1 7/16 1 610 28 1/2 11⁄2 3/4 1 9/16 11⁄4 1130 55 5/8 11⁄2 3/4 1 9/16 11⁄4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13⁄16 11⁄4 1 7/16 1 610 28 1/2 11⁄2 11⁄4 1 9/16 11⁄4 1130 55 5/8 11⁄2 11⁄4 1 9/16 11⁄4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Component of State of California OSHPD Approved Seismic Restraints System Revision 9/1/2006 OFFICE/MANUFACTURING FACILITY •1375 SAMPSON AVE. •CORONA, CA 92879 •PH: 951.737.5599 •FAX: 951.737.0330 CUSTOMER SERVICE •800.786.5266 www.tolco.com 72 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of FIG. 70 FIG. 70R FIG. 70S FIG. 71 Size Range — 1/4" thru 11/2" rod Material — Carbon Steel Function — Used for coupling two threaded rods together of equal or reduced rod sizes, with or without inspection hole. Finish — Electro-Galvanized Note — Available in HDG finish or Stainless Steel materials. Fig. 70 - Steel Rod Coupling Fig. 70R - Steel Reducing Rod Coupling Fig. 70S - Short Pattern Steel Rod Coupling Fig. 71 - Steel Window Rod Coupling Dimensions • Weights Rod Max Rec. Approx. Size Length Load Lbs. Wt./100 1/4 7/8 240 2 5/16 13/4 300 13 3/8 13/4 610 11 1/2 13/4 1130 11 5/8 21/8 1810 16 3/4 21/4 2710 27 7/8 21/2 3770 57 123/4 4960 70 11/8" - 11/2" — Consult factory for specifications Fig. 70 Dimensions • Weights Rod Max Rec. Approx. Size Length Load Lbs. Wt./100 3/8 x 1/4 1 240 4 1/2 x 3/8 1 1/4 610 7 5/8 x 1/2 1 1/4 1130 14 3/4 x 5/8 1 1/2 1810 21 7/8 x 3/4 1 3/4 2710 40 Fig. 70R Dimensions • Weights Rod Max Rec. Approx. Size Length Load Lbs. Wt./100 3/8 11/8 610 4 1/2 11/4 1130 6 For rod sizes 5/8" to 1" - consult factory Fig. 70S/Fig. 71 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 72 www.tolco.com Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11⁄4 8000 7140 360 11⁄2 11630 10370 510 Revision 9/1/2006 Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 98 - Rod Stiffener Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Component of State of California OSHPD Approved Seismic Restraints System Identification Signs ' 1996-1999 Fire Protection Products, Inc. Description Manufactured from .020" white coated aluminum. All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 require- ments. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation directly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachement of Type "B" to Type "A". Installation Specs Installation of the 6" x 2", 5" x 7", and 9" x 7" alumi- num signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the sign on the area being identified. Since all of the above mentioned signs are predrilled at all four corners, the last link of the chain can be opened and hooked through through the top holes on the signs and hung on the appropriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to the base material. (The 9" x 7" Fire Alarm Bell sign must be drilled to be attached directly to the bell gong.) Material: .020" aluminum w/ removable plastic coating Sizes: 6" x 2" 5" x 7" 9" x 7" Available designations: See current catalog for a full listing of all available signs. For questions: 1 800 344-1822 1 800 344-3775 Fax http://www.fppi.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 17 AHEAD OF THE FLOW® www.nibco.com Revision 8/3/2010 300 PSI WWP Bronze Ball Valves Fire Protection Valve • Two-Piece Body • Chrome Plated Ball • Blowout-Proof Stem • Reinforced PTFE Seats MATeRIAL LIST PART SPeCIFICATION 1. Handle Nut Zinc Plated Steel 2. Handle Zinc Plated Steel Clear Chromate with Plastisol Grip 3. Threaded Pack Gland Brass ASTM B16 4. Packing PTFE 5. Stem Silicon Bronze ASTM B371 Alloy C69430 or ASTM B99 Alloy C65100 6. Thrust Washer Reinforced PTFE 7. Ball Brass ASTM B124 Alloy C37700 or ASTM B16 Alloy C36000 with Hard Chrome Plate 8. Seat Ring (2) Reinforced PTFE 9. Body Cast Red Bronze ASTM B584 Alloy C84400 10. Body End Piece Cast Red Bronze ASTM B584 Alloy C84400 ¹⁄₄" and ³⁄₈" size only has A304 stainless steel grounding washer . 300 PSI/20 .7 Bar Non-Shock Cold Water CONFORMS TO MSS SP-110 • UL LISTED† • FM APPROVED† DIMeNSIONS—WeIGHTS—QUANTITIeS KT-585-70-UL Dimensions Size A B C D Port Weight Box Master In . mm . In . mm . In . mm . In . mm . In . mm . Lbs . Kg . Qty . Ctn . Qty . ¹⁄₄ 8 2.00 51 1.75 44 5.00 127 .38 10 .45 .20 10 100 ³⁄₈ 10 2.00 51 1.75 44 5.00 127 .38 10 .45 .20 10 100 ¹⁄₂ 15 2.44 62 1.88 48 5.19 132 .50 13 .64 .29 10 100 ³⁄4 20 2.94 75 2.25 57 6.25 159 .75 19 1.33 .60 5 50 1 25 3.34 85 2.38 59 6.44 164 1.00 25 1.79 .81 5 20 KT-580-70-UL Dimensions Size A B C D Port Weight Box Master In . mm . In . mm . In . mm . In . mm . In . mm . Lbs . Kg . Qty . Ctn . Qty . 1 ¹⁄₄ 32 3.94 100 2.63 67 6.75 171 1.00 25 2.17 .99 5 20 1 ¹⁄₂ 40 4.31 110 3.00 76 8.91 228 1.25 32 3.27 1.49 5 20 2 50 4.63 117 3.25 83 9.06 230 1.50 38 5.09 2.31 5 10 2 ¹⁄₂ 65 5.84 148 3.53 90 9.66 245 2.00 51 8.25 3.79 2 6 3 80 7.09 202 4.41 112 11.53 293 2.50 64 15.65 7.11 1 4 † UL Listed, FM Approved for trim and drain use (UL Subject 285) – Sizes ¹⁄₄" thru 2" . KT-585-70-ULFull PortNPT x NPT KT-580-70-ULStandard PortNPT x NPT KT-585-70-UL ¹⁄₄" - 1" Full Port Threaded KT-580-70-UL 1¹⁄₄" - 3" Standard Port Threaded DezincificationResistant NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 9 AHEAD OF THE FLOW ™ www.nibco.com Revised 08/01/03 175 lb. WWP Bronze Globe Valves Fire Protection Valve • Threaded Ends • Rubber Disc • Screw Over Bonnet MATERIAL LIST PART SPECIFICATION 1. Handwheel Aluminum 2. Handwheel Screw Carbon Steel Stainless Steel (1") 3. Stem Bronze ASTM B 584 Alloy C84400 or ASTM B 505 Alloy C84400 4. Packing Nut Bronze ASTM B 584 Alloy C83600 or ASTM B 16 5. Packing Graphite Impregnated (Non Asbestos) 6. Bonnet Bronze ASTM B 584 Alloy C84400 7. Body Bronze ASTM B 584 Alloy C84400 8. Seat Disc EPDM Rubber 9. Seat Screw Stainless Steel 10. Pack Washer Sheet Brass 175 PSI/12.1 Bar Non-Shock Cold Water UL LISTED* DIMENSIONS—WEIGHTS—QUANTITIES Dimensions Size A B Weight Box Master In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn. Qty. ¹⁄₄8 2.00 50 2.75 70 .48 .22 10 100 ³⁄₈10 2.00 50 2.75 70 .45 .20 10 100 ¹⁄₂15 2.28 58 3.12 79 .68 .31 10 60 ³⁄₄20 2.28 58 3.12 79 .74 .34 10 60 1 25 3.12 79 4.50 114 1.68 .76 5 25 *UL Listed for Trim and Drain use – sizes ¹⁄₂", ³⁄₄" , 1". Size ¹⁄₄" and ³⁄₈" supplied as KT-65. KT-65-UL Threaded KT-65-UL NPT x NPT Dezincification Resistant System Sensor's SpectrAlert wal-mount series includes a complete line of electronic horns, strobes, and horn/strobes. Intended for primary signaling use, SpectrAlert products meet UL1971, UL464, and Americans with Disabilities Act requirements. Performance.With its extremely efficient reflector design and Xenon flash tube, SpectrAlert offers current draw reductions as high as 40% over previous gener- ation designs. By consuming less current, the flexibility to connect more devices per loop is possible, for a lower installed cost. Installation.SpectrAlert products offer installation ease which also lowers the installed cost. By taking up no room in the back box, SpectrAlert strobes and horn/strobes make wiring connections simpler and faster. Each SpectrAlert includes a universal mounting plate for 4"square and single gang back box mounting. Accessory mounting plates are also available for small footprint or surface mount applications. Flexibility.SpectrAlert offers the flexibility to meet a broad range of requirements. The SpectrAlert horns and horn/strobes feature a number of field-selectable/reversible horn tones. For visible requirements, SpectrAlert strobes and horn/strobes are available in a wide variety of configurations to address non-sleeping area, sleeping area, and corridor requirements. Offerings include 24-volt models at 15, 15/75, 30, 75, and 110 candela, and 12-volt devices at 15 and 15/75 candela. Aesthetics. To meet building owner aesthetic requirements, SpectrAlert incorporates a stylish, low profile design. And this aesthetic is consistent across all SpectrAlert wall-mount products. Models Available* Horn/Strobes P1215 P121575 P2415 P241575 P2430 P2475 P24110 Strobes S1215 S121575 S2415 S241575 S2430 S2475 S24110 Horns H12/24 Product Overview Horn/Strobe SpectrAlert™Wall-Mount Horns, Strobes, and Horn/Strobes Meet UL and ADA signaling requirements Low current draw More devices per loop Lower installed cost Universal mounting plate included Accessory mounting plates available Field-selectable horn tones Electromechanical / 3kHz Temporal 3 / Non-temporal 3 High / Low dBA output Available in 15, 15/75, 30, 75, and 110 candela Synchronizable horns and strobes with Sync•Circuit™module Aesthetic design Strobe Horn Back Box Skirt *Refer to Ordering Information for other configurations Walk Test SpectrAlert horn/strobe and horn only work on “walk tests” with time durations of 4 seconds or greater Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5" x 55/8"x 215/16" Strobe and horn/strobe with small footprint plate 33/8" x 55/8"x 25/16" Horn with universal mounting plate 5" x 55/8"x 15/16" Horn without mounting plate 215/16" x 55/16"x 15/16" Weight, horn only 7.2 oz. Weight, strobe and horn/strobe 8.8 oz. Mounting 4" x 4" x 11/2" or 2" x 4" x 17/8" standard boxes Indoor Operating Temperature 32°F to 120°F (0°C to 49°C) Maximum humidity 95% as tested per UL464 Weatherproof (horn and horn/strobes) Operating Temperature 32°F to 150°F (0°C to 66°C) (outdoor strobe only) -40°F to 158°F (-40°C to 70°C) ULC Canadian Models -40°C to 66°C Voltages 12 or 24VDC and FWR unfiltered Operating voltage range* 12V: 10.5-17V; 24V: 20-30V Operating voltage range* (with Sync•Circuit module, MDL) 12V, 11-17V; 24V, 20-30V * These products should be operated within their rated voltage range; UL does, however, test functional integrity to -20% and +10% of manufacturer's stated ranges. U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 Specifications Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4" x 4"x 11/2" back box or a single gang 2" x 4" x 17/8" back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert products, when used in conjuction with the accessory Sync•Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 10.7–17 volts. 24-volt rated devices shall have an operating voltage range or 20–30 volts. SpectrAlert products shall have an operating temperature of 32°to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Horn Horn shall be a System Sensor SpectrAlert Model capable of operating at 12 and 24 volts. Horn shall be listed to UL 464 for fire protective signaling systems. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. All horn models shall operate on a coded power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/strobe models shall operate on a coded or non-coded power supply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync•Circuit listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16"x 411/16"x 21/8" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Sound Output Guide (dBA) UL Reverberant Room dBA @ volts DC Anechoic Room Peak dBA @ 10ft./volts DC 10.5 12 17 20 24 30 10.5 12 17 20 24 30 Temporal Low Tone Electromechanical NA NA NA 75 75 79 NA NA NA 94 96 98 3000 HZ Interrupted NA NA NA 75 79 79 NA NA NA 94 96 98 High Tone Electromechanical 75 75 79 82 82 82 94 95 98 100 101 102 3000 HZ Interrupted 75 75 79 82 85 85 94 95 98 100 101 102 Non-Temporal Low Tone Electromechanical NA NA NA 79 82 85 NA NA NA 94 96 98 3000 HZ Interrupted NA NA NA 82 82 85 NA NA NA 94 96 98 High Tone Electromechanical 79 79 85 85 88 88 94 95 98 100 101 102 3000 HZ Interrupted 79 82 85 88 88 88 93 95 98 100 101 102 Average Current (mA) 12V Models 24V Models 10.5V 12V 17V 20V 24V 30V Candela DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR 15 133 159 114 157 81 128 50 61 43 60 38 60 15/75 168 182 142 171 99 150 56 65 49 64 44 62 30 NA NA NA NA NA NA 78 84 67 82 58 72 75 NA NA NA NA NA NA 145 170 123 159 102 141 110 NA NA NA NA NA NA 169 220 140 191 115 174 SpectrAlert Current Draw Table Strobe Only Horn Only Average Current (mA) 12V Models 24V Models High/Low Temp/ 10.5V 12V 17V 20V 24V 30V Tone Volume Non DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR Electro- High Temp 10 11 10 10 14 14 19 21 25 18 29 26 mech. Non 10 16 10 19 14 25 17 29 23 34 30 42 Low Temp NA NA NA NA NA NA 11 12 13 13 17 15 Non NA NA NA NA NA NA 12 16 14 19 17 24 3000 Hz High Temp 11 13 11 11 16 16 24 26 28 23 37 33 Interrupt. Non 11 17 11 21 14 28 19 34 27 39 35 45 Low Temp NA NA NA NA NA NA 14 14 17 15 21 19 Non NA NA NA NA NA NA 13 18 16 21 22 25 In Rush Current (mA) 12V Models 24V Models 10.5V 12V 17V 20V 24V 30V DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR 80 108 92 124 140 190 97 129 116 152 147 198 76 104 88 126 160 185 97 135 116 164 147 211 NA NA NA NA NA NA 97 129 116 152 147 198 NA NA NA NA NA NA 190 240 230 280 290 380 NA NA NA NA NA NA 190 230 220 290 290 370 Horn/Strobe 15 cd Average Current (mA) 12V Models 24V Models High/Low Temp/ 10.5V 12V 17V 20V 24V 30V Tone Volume Non DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR Electro- High Temp 143 170 124 167 95 142 69 82 68 78 67 87 mech. Non 143 170 124 167 95 142 67 90 66 94 68 103 Low Temp NA NA NA NA NA NA 61 73 56 73 55 76 Non NA NA NA NA NA NA 62 77 57 79 55 85 3000 Hz High Temp 144 172 125 168 97 144 74 87 71 83 75 94 Interrupt. Non 144 173 125 168 95 146 69 95 70 99 73 106 Low Temp NA NA NA NA NA NA 64 75 60 75 59 80 Non NA NA NA NA NA NA 63 79 59 81 60 86 Horn/Strobe 1575 cd Average Current (mA) 12V Models 24V Models High/Low Temp/ 10.5V 12V 17V 20V 24V 30V Tone Volume Non DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR Electro- High Temp 178 193 152 181 113 164 75 86 74 82 73 88 mech. Non 178 193 152 181 113 164 73 94 72 98 74 104 Low Temp NA NA NA NA NA NA 67 77 62 77 61 77 Non NA NA NA NA NA NA 68 81 63 83 61 86 3000 Hz High Temp 179 195 152 183 115 166 80 91 77 87 81 95 Interrupt. Non 179 196 152 183 113 168 75 99 76 103 79 107 Low Temp NA NA NA NA NA NA 70 79 66 79- 65 81 Non NA NA NA NA NA NA 69 83 65 85 66 87 Horn/Strobe 30 cd Average Current (mA) 24V Models High/Low Temp/ 20V 24V 30V Tone Volume Non DC FWR DC FWR DC FWR Electro- High Temp 97 105 92 100 87 98 mech. Non 95 113 90 116 88 114 Low Temp 89 96 80 95 75 87 Non 90 98 81 101 75 96 3000 Hz High Temp 102 108 95 105 95 105 Interrupt. Non 97 116 94 121 93 117 Low Temp 92 96 84 97 79 91 Non 91 100 83 103 80 97 Horn/Strobe 75 cd Average Current (mA) 24V Models High/Low Temp/ 20V 24V 30V Tone Volume Non DC FWR DC FWR DC FWR Electro- High Temp 164 191 148 167 131 167 mech. Non 163 188 146 169 132 169 Low Temp 156 182 136 162 119 156 Non 157 182 137 162 119 157 3000 Hz High Temp 169 196 151 172 139 174 Interrupt. Non 164 192 150 175 137 177 Low Temp 159 184 140 164 123 160 Non 158 188 139 163 124 162 Horn/Strobe 110 cd Average Current (mA) 24V Models High/Low Temp/ 20V 24V 30V Tone Volume Non DC FWR DC FWR DC FWR Electro- High Temp 188 241 165 209 144 200 mech. Non 186 238 163 211 145 202 Low Temp 180 232 153 204 132 189 Non 181 232 154 204 132 190 3000 Hz High Temp 193 246 168 214 152 207 Interrupt. Non 188 242 167 217 150 210 Low Temp 183 234 157 206 136 193 Non 182 232 156 205 137 195 Peak Current (mA) 12V Models 24V Models 10.5V 12V 17V 20V 24V 30V DC FWR DC FWR DC FWR DC FWR DC FWR DC FWR 460 460 450 460 420 480 135 204 135 208 135 185 490 520 490 520 460 480 150 199 150 207 150 198 NA NA NA NA NA NA 183 201 183 219 183 216 NA NA NA NA NA NA 350 440 340 460 330 480 NA NA NA NA NA NA 460 560 450 570 420 620 Avg. mA* Avg. mA* Red White Voltage Candela @Nom. VDC @Nom.FWR** Horn/Strobes P1215 P1215W 12 15 124 167 P121575 P121575W 12 15/75 152 181 P2415 P2415W 24 15 68 78 P241575 P241575W 24 15/75 74 82 P2430 P2430W 24 30 92 100 P2475 P2475W 24 75 148 167 P24110 P24110W 24 110 165 209 P121575K (weatherproof)—12 15/75 124 167 P241575K (weatherproof)—24 15/75 74 82 P2475K (weatherproof)—24 75 148 167 P24110K (weatherproof)—24 110 165 209 P241575P (no lettering) P241575PW 24 15/75 74 82 P241575AG (AGENT)—24 15/75 74 82 P241575EV (EVAC)—24 15/75 74 82 Canada P2415A P2415WA 24 15 68 78 P241575A P241575WA 24 15/75 74 82 P2475A P2475WA 24 75 148 167 P24110A P24110WA 24 110 165 209 P241575KA (weatherproof)—24 15/75 74 82 P2475KA (weatherproof)—24 75 148 167 P24110KA (weatherproof)—24 110 165 209 Latin America P241575F (FUEGO)—24 15/75 74 82 Strobes S1215 S1215W 12 15 114 157 S121575 S121575W 12 15/75 142 171 S2415 S2415W 24 15 43 60 S241575 S241575W 24 15/75 49 64 S2430 S2430W 24 30 67 82 S2475 S2475W 24 75 123 159 S24110 S24110W 24 110 140 191 S121575K (weatherproof)—12 15/75 142 171 S241575K (weatherproof)—24 15/75 49 64 S2475K (weatherproof)—24 75 123 159 S24110K (weatherproof)—24 110 140 191 S241575P (no lettering) S241575PW 24 15/75 49 64 S241575AG (AGENT)—24 15/75 49 64 S241575EV (EVAC)—24 15/75 49 64 Canada S2415A S2415WA 24 15 43 60 S241575A S241575WA 24 15/75 49 64 S2475A S2475WA 24 75 123 149 S24110A S24110WA 24 110 140 191 S241575KA (weatherproof)—24 15/75 49 64 S2475KA (weatherproof)—24 75 123 149 S24110KA (weatherproof)—24 110 140 191 Latin America S241575F (FUEGO)—24 15/75 49 64 Horns H12/24 H12/24W 12/24 NA 10/25 10/18 H12/24K (weatherproof)—12/24 NA 10/25 10/18 Canada HC12/24A HC12/24WA 12/24 NA 10/25 10/18 HC12/24KA —12/24 NA 10/25 10/18 Sync•Circuit MDL MDLW 12/24 NA 10/11 12/15 Module Canada MDLA MDLWA 12/24 NA 10/11 12/15 Small Footprint Mounting Plate for Single Gang Only S-MP S-MPW NA NA NA NA Surface Mount Back Box Skirt BBS BBSW NA NA NA NA Universal Mounting Plate (replacement) D-MP D-MPW NA NA NA NA Weatherproof Back Box WBB —NA NA NA NA Notes:Agency Listings- Indoor models: UL, ULC, FM, CSFM, MEA. Weatherproof models: UL, CSFM (strobe only), MEA, ULC. All of these SpectrAlert products are designed for wall mount only. All weatherproof models must use weatherproof back box model WBB. Installation of less than 75 can- dela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/strobes are recommended for 20' x 20' rooms or less. *Horn and horn/strobe current draws assume horn is set at temp 3, electromechanical tone and high audibility. ** FWR = Full Wave Rectified SpectrAlert Ordering Information System Sensor Sales and Service © 1999 System Sensor. The company reserves the right to change product specifications without notice. A05-936-09•6/00(10K)•#572 System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800-SENSOR2 Fx: 630/377-6495 Documents On Demand: 1-800-736-7672 x3 Web: www.systemsensor.com System Sensor in Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor in Europe Ph: + 44.1403.276500 Fx: + 44.1403.276501 System Sensor in China Ph: + 86.29.524.6253 Fx: + 86.29.524.6259 System Sensor in Singapore Ph: + 65.273.2230 Fx: + 65.273.2610 System Sensor in the Far East Ph: + 852.21919003 Fx: + 852.27366580 System Sensor in Australia Ph: + 613.54.281.142 Fx: + 613.54.281.172 System Sensor in India Ph: + 91.11.558.2119 Fx: + 91.11.567.6815 4 For the most up to date information, visit www.sammysuperscrew.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230 (Fir) 25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) VERTICAL MOUNT WOOD WOOD WOOD WOOD WOODSAMMYS® for Wood Installs VERTICALLY into the bottom of wood structures easily and quickly! #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 10. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty 3/8" 8139957 SH-GST 20 1/4 x 2" 1257 (Fir) 1050 1475 25 125 125 3/8" 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver Part # 8113910 SAMMY Swivel Head®for Wood Product Features ‡No pre-drilling required. ‡ Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. ‡ Saves time from traditional methods. ‡5HGXFHVLQVWDOODWLRQFRVW ‡0DGHLQWKH86$ Product Features ‡Eliminates distortion of threaded rod. ‡ Accommodates up to 3 ½” x 12 pitch roof. ‡$OORZVƒGHÀHFWLRQIURPYHUWLFDO ‡ Saves time from traditional methods. ‡5HGXFHVLQVWDOODWLRQFRVW ‡0DGHLQWKH86$ Installs VERTICALLY and swivels up to 17° in wood structure 4 For the most up to date information, visit www.sammysuperscrew.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230 (Fir) 25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) VERTICAL MOUNT WOOD WOOD WOOD WOOD WOODSAMMYS® for Wood Installs VERTICALLY into the bottom of wood structures easily and quickly! #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 10. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty 3/8" 8139957 SH-GST 20 1/4 x 2" 1257 (Fir) 1050 1475 25 125 125 3/8" 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver Part # 8113910 SAMMY Swivel Head®for Wood Product Features ‡No pre-drilling required. ‡ Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. ‡ Saves time from traditional methods. ‡5HGXFHVLQVWDOODWLRQFRVW ‡0DGHLQWKH86$ Product Features ‡Eliminates distortion of threaded rod. ‡ Accommodates up to 3 ½” x 12 pitch roof. ‡$OORZVƒGHÀHFWLRQIURPYHUWLFDO ‡ Saves time from traditional methods. ‡5HGXFHVLQVWDOODWLRQFRVW ‡0DGHLQWKH86$ Installs VERTICALLY and swivels up to 17° in wood structure 5 7R¿QGDGLVWULEXWRUQHDU\RXFDOO%8,/'(; Not less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist HORIZONTAL MOUNT WOOD WOOD WOOD WOOD WOODSIDEWINDERS® for Wood Installs HORIZONTALLY into the side of wood structures easily and quickly! Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Composite/Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380 (tools available on pg 10 ) Product Features ‡No pre-drilling required. ‡ Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. ‡ Saves time from traditional methods. ‡5HGXFHVLQVWDOODWLRQFRVW ‡0DGHLQWKH86$ Sprinkler Cabinets3, 6, & 12 Sprinklers, 1/2 or 3/4 Inch NPT 6 ESFR Sprinklers, 3/4 or 1 Inch NPT Page  of 4 AUGUST, 2007 TFP785 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description Tyco® Sprinkler Cabinets are con-structed of metal enclosures with hinged covers designed to provide on-site storage of an emergency supply of sprinklers and a sprinkler wrench. NFPA 13 requires a representative number of each type of sprinkler used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers that may have operated or become damaged. Sprinkler Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate NPT threaded sprin-klers and are painted an attractive red enamel. WARNINGSThe Sprinkler Cabinets described here-in must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso-ciation, in addition to the standards of any other authorities having jurisdic-tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain-ing their fire protection system and de-vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Material Carbon Steel Weights 3 Sprinkler Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5 Lbs. (0,68 kg) 6 Sprinkler Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3 Lbs. (1,04 kg) 12 Sprinkler Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.0 Lbs. (1,81 kg) 6 ESFR Sprinkler Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . .3.3 Lbs. (1,36 kg) Page 2 of 4 TFP785 5-1/4"R(133,4 mm) DOOR SWING MINIMUM CLEARANCE 6"(150 mm) 2-9/16"(65,1 mm) HOLES ACCOMMODATE (127,0 mm)(25,4 mm) SCREWS 3/16"(5 mm)HOLES FOR 2"1-3/16"(50,8 mm) 1"5" (30,2 mm) (127,0 mm)5" (184,2 mm)7-1/4"1-1/4"(31,8 mm) REMOVE KNOCKOUTS 3/4"NPT SPRINKLERS TO ACCOMMODATE 1/2"NPT SPRINKLERS 1-3/4"(44,5 mm) (98,4 mm)3-1/4"2-5/8"(66,7 mm) 1-1/8"(28,6 mm) 1"(25,4 mm) STRAP HANGER SLOTS FORSPRINKLERSHELF WRENCHSHELF 1-5/16"(33,3 mm) HINGES DOOR NOT SHOWN AND HINGES 1-3/4"(44,5 mm) (152,4 mm)3-1/4"(98,4 mm) 10-13/16"(274,6 mm) 6" 14-1/16"(357,2 mm) (30,2 mm) (127,0 mm)1"(25,4 mm) 5" 1-5/8" 1-3/16" (41,3 mm) (31,8 mm)1-1/4" TO ACCOMMODATE 3/4"NPT SPRINKLERS REMOVE KNOCKOUTS 1/2"NPT SPRINKLERS (33,3 mm)1-5/16" HOLES ACCOMMODATE MINIMUM 6"(150 mm) CLEARANCE (65,1 mm)2-9/16" DOOR SWING (133,4 mm)5-1/4"R (50,8 mm)2" SHELF WRENCHHOLESFOR 3/16"(5 mm) SCREWS SPRINKLER SLOTS FOR STRAP HANGER 1"(25,4 mm)SHELF HINGES DOOR NOT SHOWN AND HINGES FIGuRe 1 3 SpRINkleR CAbINet FIGuRe 2 6 SpRINkleR CAbINet TFP785 Page  of 4 (127,0 mm) HOLES ACCOMMODATE 1-3/4"(25,4 mm) SCREWS 3/16"(5 mm)HOLES FOR (44,5 mm) 1"(25,4 mm) STRAP HANGER SLOTS FORSPRINKLER SHELF WRENCH SHELF 1-1/2" (98,4 mm) 3-1/4"6"2"1-3/16"(152,4 mm)(50,8 mm) 1"5" (30,2 mm) (274,6 mm)10-13/16" (357,2 mm) 14-1/16" (41,3 mm)1-5/8" 1-1/8"(28,6 mm) (38,1 mm) REMOVE KNOCKOUTS 3/4"NPT SPRINKLERS TO ACCOMMODATE 1/2"NPT SPRINKLERS 5-1/4"R 4-1/8"MINIMUM CLEARANCE (104,8 mm) 6"(150 mm) DOOR SWING (133,4 mm) 1-1/2"(38,1 mm)HINGES DOOR NOT SHOWN AND HINGES (357,2 mm) 14-1/16" (274,6 mm)10-13/16" (157,2 mm)6-3/16" MINIMUM 7"(180 mm) (152,4 mm)6" (39,7 mm) 1-9/16" 2"(50,8 mm) 1-5/8"(41,3 mm) (96,8 mm)3-13/16" (60,3 mm)2-3/8" CLEARANCE DOOR SWING (163,5 mm)6-7/16"R 1-3/16"(30,2 mm) (25,4 mm)1" 3/4"NPT SPRINKLERSHOLESACCOMMODATETOACCOMMODATE REMOVE KNOCKOUTS 1"NPT SPRINKLERS 3-1/8"(79,4 mm) DOOR AND HINGES SLOTS FOR STRAP HANGER 1"(25,4 mm)3/16"(5 mm)HOLES FOR SCREWS SHELF WRENCH SHELF SPRINKLER HINGES (39,7 mm)1-9/16" NOT SHOWN FIGuRe 3 12 SpRINkleR CAbINet FIGuRe 4 6 eSFR SpRINkleR CAbINet Page 4 of 4 TFP785 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 Installation Sprinkler Cabinets are designed with two 3/16 Inch (4,7 mm) diameter holes for wall mounting or direct attachment to the system riser with a strap-type hanger. The Sprinkler Cabinet should be installed at or near the system con-trol valve and must be stocked with an adequate supply of spare sprinklers and a sprinkler wrench. The stock of spare sprinklers should include sprinklers of each type and temperature rating as are installed in the sprinkler system, in the following quantities: Sprinklers In System Spare Sprinklers Required Under 300 6 300-1000 12 Over 1000 24 The 3, 6, and 12 Sprinkler Cabinets are designed to accept both 1/2 & 3/4 Inch NPT threaded sprinklers, where-as the 6 ESFR Sprinkler Cabinets are designed to accept both 3/4 & 1 Inch NPT threaded sprinklers. As neces-sary, insert a screwdriver blade from the front top of the shelf and under the near bottom part of the knockout an-nular ring. Press the screwdriver han-dle down to remove the knockout ring. Care and Maintenance The Sprinkler Cabinet, wrench, and stock of spare sprinklers should be in-spected at least quarterly. The follow-ing items should be checked: • The Sprinkler Cabinet should be readily accessible, and not exposed to a corrosive atmosphere or tem-peratures in excess of 100°F (38°C). • The stock of spare sprinklers should include an adequate number of each type and temperature rating. • The stock of sprinklers must be in good condition. • A sprinkler wrench of the appropriate type must be included in the Sprin-kler Cabinet. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war-ranted solely to the original Buyer for ten (10) years against defects in mate-rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran-ty is given for products or components manufactured by companies not af-filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in-stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec-tion Association, and/or the standards of any other Authorities Having Juris-diction. Materials found by TFBP to be defective shall be either repaired or re-placed, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob-ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam-ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex-press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex-clusive remedy for claims based on failure of or defect in products, materi-als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex-tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis-tributor for availability. Sprinkler Cabinet:Specify: (Description), P/N (specify). 3 Sprinkler Cabinet. . . . . . . . . . . . . . . . . P/N 1177 6 Sprinkler Cabinet. . . . . . . . . . . . . . . . . P/N 111912 Sprinkler Cabinet . . . . . . . . . . . . . . . .P/N 1124 6 ESFR Sprinkler Cabinet . . . . . . . . . . . P/N 1111 FIRE DEPT. INLET CONN. FLUSH TYPE6341-6345 SERIES SINGLE INLET An inlet connection with 250 G.P.M. minimum inlet capacity to supplement the fire protection water supply. Provides unobstructed water supply. Flush round design enhances appearance and provides unobstructed passage. STANDARD EQUIPMENT:Cast Brass round plate with double female adapter; plug and chain; branding as selected. SPECIFY THREAD AND BRANDING. BRANDING: "Standpipe", "Auto Spkr." FINISH: Cast Brass OPTIONAL FINISH:PB-Polished Brass PC-Polished Chrome RESIDENTIAL FIRE DEPT. CONNECTION An inlet connection to supplement the water supply to a residential sprinkler system. STANDARD EQUIPMENT: 1 1/2" cast brass round plate assembly with integral pin lug swivel inlet. Hose thread inlet swivel, 1 1/2" NPT female outlet on back of plate. Cast brass plug and brass chain. Overall outside Diameter 4 3/8". SPECIFY THREAD AND BRANDING. U/L LISTED. BRANDING: "Auto Spkr." FINISH: Cast Brass OPTIONAL FINISH:PB-Polished Brass PC-Polished Chrome Figure No. 6341 Figure No. 6342 Figure No. 6345 Page 6-12 Round Plate Figure No. Size 6341 2 1/2 X 2 1/2 6342 3 X 2 1/2 6343 3 X 3 ___________________________________________________