FireLock NXT Actuated Valve with LPCB Approved Preaction Trim.pdf
FEATURES The valve allows the water to operate a water motor alarm and/or electric pressure alarms, which continue until the flow of water stops. The valve is rated to 300 psi/2065 kPa water working pressure and is factory tested hydrostatically to 600 psi/4135 kPa for sizes 1 1/2 – 8"/40 – 200 mm. Required air pressure is 13 psi/90 kPa. The Series 769 is available grooved x grooved. Standard grooved dimensions conform to ANSI/AWWA C606. Victaulic Series 769 Preaction valves do NOT require a separate check valve in the preaction system and feature a straight-through valve body design that provides superior flow and low-pressure drop. The valve body is tapped with a special drain for a complete system. The valve has simple access to all internal parts for easy maintenance. All internal parts are replaceable. Maintenance and service can be performed from the installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve. The body is tapped for main drain and all available trim configurations. The valve is painted inside and out to increase corrosion resistance. The Victaulic Series 769 FireLock NXT Preaction valve trim includes an alarm test valve, which allows testing of the alarm system without reducing the system pressure. NOTE: The bare value carries VdS approvals for deluge applications only. There is no VdS recognition of the preaction configurations. The AutoConvert trim configurations are FM and LPCB Approved only. ClapperSeal DiaphragmAssembly LatchClapper Seat NOTE: VALVE IS SHOWN ABOVE IN THE “SET” POSITION Exaggerated for Clarity The patented Victaulic Series 769 FireLock NXT™ Preaction Valve controls the water sup- ply entry into the Preaction system piping and sprinklers. The preaction system is normally supervised with pressurized air or nitrogen in order to detect any leaks in the system. The Series 769 valve is a low differential, latched clapper valve that uses a unique, direct-acting diaphragm to separate system water supplies from Preaction pipe sprinkler systems. The posi- tive latching mechanism uses the supply water pressure from upstream (city side) of the main control valve to hold the clapper shut. When the water pressure in the diaphragm chamber is released the latch retracts from the clapper and the valve actuates. The low differential and unique latch and actuator design of the valve allow the valve to be self-resetting; therefore it is not necessary to remove the cover. The low differential design is not subject to water columns. AutoConvert Dry Trim Option: Recommended for Preaction applications where reliability of power supply is a concern. In the event of an AC power loss, the AutoConvert module latches from Closed to Open with a quick electrical pulse. To stay open, no further current draw is required as would be needed in a normally-open solenoid. This opened pathway allows the included Series 776 Low Pressure Actuator to operate as a dry actuator, putting the preaction system into a Non-Interlocked condition. In this case, an air loss in the system piping or an electrical release from the Fire Alarm Control Panel (FACP) would allow the Series 769 valve to actuate, filling the piping with water. Upon an AC power return, the Auto-Convert module senses the restoration and latches the path from the Series 776 Low Pressure Actuator closed, returning the preaction valve to its standard release method. Exaggerated for Clarity NOTE: Valve is shown in the “set” position 30.85_1 FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769with:- Electric Activation with Redundant Solenoid Valve- Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim- Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve- Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim 30.85FIRE PROTECTION PRODUCTS – DEVICES JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PATENTED REV_A Vic-Quick Riser The Vic-Quick Riser comes completely pre-trimmed and includes a shut off valve (uses a Series 705W or Series 705 FireLock Butterfly valve – request publication 10.18 or 10.81. For 1 1/2 and 2"/40 and 50 mm sizes, the Vic-Quick Riser may come with a Series 728 Ball Valve – request publication 10.17) for system shut off, pre-set pressure switches, and a drain kit for ease of installation. INSTALLATION OPTIONS RELEASE MECHANISM OPTIONS Single Interlocked SIngle-interlocked systems are designed so that either an event detection by the release mechanism or loss of supervisory air in the sprinkler system will cause the valve to operate. When the valve oper- ates, water will enter the sprinkler system and flow from any open sprinklers or other openings in the system. The Victaulic electric release system uses an electric solenoid valve, approved electric panel and a compatible detection system. When EITHER an electric detection or a system sprinkler operates, the water in the diaphragm chamber is released and the valve operates. If there is an electric detection and a system sprinkler does not operate, water will fill the sprinkler sys- tem, alarms will be activated and the Victaulic Series 769 Actuated Valve will act as an Alarm Check Valve. If the valve is actuated by the activation or damage of a sprinkler system sprinkler, water will enter the system and flow from any open sprinklers. Alarms will activate due to water entering the intermediate chamber of the valve. The Victaulic Electric Release System uses an electric solenoid valve, approved electric panel and a compatible detection system. Only when a release system event occurs, will the water in the diaphragm chamber be released and the valve operate. Pneumatic pressure is main- tained in the sprinkler system only for supervisory purposes and a low pressure alarm is installed in the sprinkler system in order to detect any leaks in the system. If there is an electric release activa- tion and a sprinkler system sprinkler does not operate, the valve will operate and water will fill the sprinkler system, alarms will be activated and the Victaulic Series 769 Actuated Valve will act as an Alarm Check Valve. If a system sprinkler is damaged or activates and there is no release mechanism detection, the low pressure alarm in the system will activate but the valve will not operate and no water will flow until there is a release detection. AutoConvert Trim: In the event of an AC power loss, the AutoConvert module latches from Closed to Open with a quick electrical pulse. To stay open, no further current draw is required as would be needed in a normally open solenoid. This opened pathway allows the included Series 776 Low Pressure Actuator to operate as a dry actuator, putting the preaction system into a Non-Interlocked condition. In this case, an air loss in the system piping or an electrical release from the FACP would allow the Series 769 valve to actuate, filling the piping with water. Upon an AC power return, the Auto-Convert module senses the restoration and latches the path from the Series 776 Low Pressure Actuator closed, returning the preaction valve to its standard release method. This automatic sensing and automatic action allows continuous fire protection in the event of an AC power loss and possible battery backup failure. 30.85_2 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A Double Interlocked Double interlocked systems are designed so that the valve will actuate only in the event of multiple fire detections by the release mechanisms. If a single release event occurs alarms will sound but the valve will not operate and water will not flow until a second release event is detected. Double inter- locked systems are commonly used in refrigerated systems and in systems where water entering the sprinkler system is critical as well as when accidental discharge of water is critical. The electric/pneumatic preaction system uses both an electric release system, (composed of an approved solenoid valve, electric panel and an appropriate sensor), and pneumatically pressurized sprinkler system. The Victaulic Series 769 Actuated Valve will activate ONLY when there is a pressure loss in the sprinkler system AND the electric detection of a release event. In the event of a loss of pressure in the sprinkler system without an electric detection the valve will not actuate until a second release event is detected. In this way if there is accidental damage to the sprinkler system no water will flow. Additionally, if there is an electric detection and no pressure loss in the sprinkler system the valve will not actuate. Alarms will activate in both cases alerting the user of a detection condition. Electric-Pneumatic/Electric: The electric-pneumatic/electric release uses two electric detection devices, a fire detection device and a low pressure switch installed in the sprinkler system. Both electric detection devices are wired into an approved control panel in a “cross-zoned” configuration. The electric control panel controls a solenoid valve piped to the Victaulic Series 769 Actuated Valve piston. In the event of a fire detection device activation and no pressure loss in the sprinkler system the control panel will not trigger the solenoid valve and the valve will not actuate. If there is a loss of pressure in the sprinkler system due to damage or a sprinkler activating and no fire detection the control panel will not trigger the solenoid and the valve will not actuate. The valve will actuate ONLY when BOTH a fire detection event and loss of system pressure occurs. When BOTH signals are received by the control panel the panel triggers the solenoid valve. This allows the water supply pres- sure in the Series 769 diaphragm chamber to be released and the valve will actuate allowing water into the system. Electric/Electric: The electric/electric release uses two zones of electric detection devices installed in the sprinkler system. Both zones of electric detection devices are wired into an approved control panel in a “cross-zoned” configuration. The electric control panel controls a solenoid valve piped to the Victaulic Series 769 Actuated Valve diaphragm charge line. In the event of a single electric fire detection device activation, the control panel will not trigger the solenoid valve and the valve will not actuate. If there is a loss of pressure in the sprinkler system due to damage or a sprinkler activating and no fire detection the control panel will not trigger the solenoid and the valve will not actuate. The valve will actuate ONLY when BOTH zones of electric fire detection devices are activated. When BOTH signals are received by the control panel, the panel triggers the solenoid valve. This allows the water supply pressure in the Series 769 diaphragm chamber to be released and the valve will actuate allowing water into the system. In this configuration, a minimum air pressure is required to maintain supervisory alarms and low pressure switches. AutoConvert Trim: In the event of an AC power loss, the AutoConvert module latches from Closed to Open with a quick electrical pulse. To stay open, no further current draw is required as would be needed in a normally open solenoid. This opened pathway allows the included Series 776 Low Pressure Actuator to operate as a dry actuator, putting the preaction system into a Non-Interlocked condition. In this case, an air loss in the system piping or an electrical release from the FACP would allow the Series 769 valve to actuate, filling the piping with water. Upon an AC power return, the Auto-Convert module senses the restoration and latches the path from the Series 776 Low Pressure Actuator closed, returning the preaction valve to its standard release method. This automatic sensing and automatic action allows continuous fire protection in the event of an AC power loss and possible battery backup failure. RELEASE MECHANISM OPTIONS 30.85_3 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A SYSTEM TRIM DIMENSIONS H A J A1 B G K C E F D Size Dimensions – inches/mm Aprx. Weight Each lbs/kg Nominal Sizeinchesmm Actual Out. Dia. inchesmm A A1 B C D E F G H J K Without Trim With Trim 1½ 1.900 9.08 16.46 25.25 11.50 18.75 9.75 12.50 7.00 3.04 9.09 7.63 16.7 43.040 48.3 230.6 418.1 641.4 292.1 476.3 247.7 317.5 177.8 77.2 230.9 193.8 7.6 19.5 2 2.375 9.08 16.46 25.25 11.50 18.75 9.75 12.50 7.00 3.04 9.09 7.63 16.7 43.050 60.3 230.6 418.1 641.4 292.1 476.3 247.7 317.5 177.8 77.2 230.9 193.8 7.6 19.5 2 ½ 2.875 12.70 16.63 29.00 11.50 18.75 11.00 9.50 5.50 3.74 10.78 6.97 41.0 65.065 73.0 322.6 422.4 736.6 292.1 476.3 279.4 241.3 139.7 95.0 273.8 177.0 18.7 29.5 76.1 mm 3.000 12.70 16.63 29.00 11.50 18.75 11.00 9.50 5.50 3.74 10.78 6.97 41.0 65.076.1 322.6 422.4 736.6 292.1 476.3 279.4 241.3 139.7 95.0 273.8 177.0 18.7 29.5 3 3.500 12.70 16.63 29.00 11.50 18.75 11.00 9.50 5.50 3.74 10.78 6.97 41.0 65.080 88.9 322.6 422.4 736.6 292.1 476.3 279.4 241.3 139.7 95.0 273.8 177.0 18.7 29.5 4 4.500 15.15 19.96 29.75 14.25 22.50 11.25 14.25 4.25 6.30 9.51 8.50 59.0 95.0100 114.3 384.8 507.0 755.7 362.0 571.5 285.8 362.0 108.0 160.0 241.6 215.9 26.7 43.0 165.1 mm 6.500 16.13 22.17 30.00 14.50 26.50 11.75 14.75 4.50 6.30 9.50 8.89 80.0 116.0165.1 409.7 563.1 762.0 368.3 673.1 298.5 374.7 114.3 160.0 241.3 225.8 36.2 52.6 6 6.625 16.13 22.17 30.00 14.50 26.50 11.75 14.75 4.50 6.30 9.50 8.89 80.0 116.0150 168.3 409.7 563.1 762.0 368.3 673.1 298.5 374.7 114.3 160.0 241.3 225.8 36.2 52.6 8 8.625 17.63 23.09 31.00 16.00 28.75 13.00 15.25 4.25 6.30 9.27 10.26 122.0 158.0200 219.1 447.8 586.5 787.4 406.4 730.3 330.2 387.4 108.0 160.0 235.5 260.6 55.3 71.6 NOTES: The “A” dimension coupling is not shown for clarity. Components shown as dotted lines denote optional equipment * Measurements denoted with an asterisk take optional equipment into account Optional drain connection kit is shown for reference and takeout dimensions. The 4inch/114.3 mm configuration is shown above 1 ½ – 2 inch/48.3 – 60.3 mm configurations contain ¾inch/19 mm drain valves. 2 ½ – 3 inch/73.0 – 88.9 mm configurations contain 1 ¼ inch/31 mm drain valves. 4 – 8 inch/114.3 – 219.1 mm configurations contain 2 inch/50 mm drain valves. 30.85_4 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Electric Activation With Redundant Solenoid Valve www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A Size Dimensions – inches/mm Aprx. Weight Each lbs/kg Nominal Sizeinchesmm Actual Out. Dia. inchesmm A A1 B B1* C D E F G* H J K Without Trim With Trim 1½ 1.900 9.08 16.46 28.25 42.75 13.50 22.00 9.25 15.25 24.75 3.04 9.09 7.63 16.7 43.040 48.3 230.6 418.1 717.6 1085.9 342.9 558.8 235.0 387.4 628.7 77.2 230.9 193.8 7.6 19.5 2 2.375 9.08 16.46 28.25 42.75 13.50 22.00 9.25 15.25 24.75 3.04 9.09 7.63 16.7 43.050 60.3 230.6 418.1 717.6 1085.9 342.9 558.8 235.0 387.4 628.7 77.2 230.9 193.8 7.6 19.5 2 ½ 2.875 12.70 16.63 31.50 46.25 12.50 21.75 11.00 14.75 22.75 3.74 10.78 6.97 41.0 65.065 73.0 322.6 422.4 800.1 1174.8 317.5 552.5 279.4 374.7 577.9 95.0 273.8 177.0 18.7 29.5 76.1 mm 3.000 12.70 16.63 31.50 46.25 12.50 21.75 11.00 14.75 22.75 3.74 10.78 6.97 41.0 65.076.1 322.6 422.4 800.1 1174.8 317.5 552.5 279.4 374.7 577.9 95.0 273.8 177.0 18.7 29.5 3 3.500 12.70 16.63 31.50 46.25 12.50 21.75 11.00 14.75 22.75 3.74 10.78 6.97 41.0 65.080 88.9 322.6 422.4 800.1 1174.8 317.5 552.5 279.4 374.7 577.9 95.0 273.8 177.0 18.7 29.5 4 4.500 15.15 19.96 32.50 47.00 14.25 24.75 10.25 16.50 22.50 6.30 9.51 8.50 59.0 95.0100 114.3 384.8 507.0 825.5 1193.8 362.0 628.7 260.4 419.1 571.5 160.0 241.6 215.9 26.7 43.0 165.1 mm 6.500 16.13 22.17 32.75 47.50 14.50 28.75 11.75 17.25 21.75 6.30 9.50 8.89 80.0 116.0165.1 409.7 563.1 831.9 1206.5 368.3 730.3 298.5 438.2 552.5 160.0 241.3 225.8 36.2 52.6 6 6.625 16.13 22.17 32.75 47.50 14.50 28.75 11.75 17.25 21.75 6.30 9.50 8.89 80.0 116.0150 168.3 409.7 563.1 831.9 1206.5 368.3 730.3 298.5 438.2 552.5 160.0 241.3 225.8 36.2 52.6 8 8.625 17.63 23.09 32.50 47.00 16.00 31.50 13.00 18.00 20.00 6.30 9.27 10.26 122.0 158.0200 219.1 447.8 586.5 825.5 1193.8 406.4 800.1 330.2 457.2 508.0 160.0 235.5 260.6 55.3 71.6 The “A” dimension coupling is not shown for clarity. Components shown as dotted lines denote optional equipment * Measurements denoted with an asterisk take optional equipment into account The 4inch/114.3 mm configuration is shown above 1 ½ – 2 inch/48.3 – 60.3 mm configurations contain ¾inch/19 mm drain valves. 2 ½ – 3 inch/73.0 – 88.9 mm configurations contain 1 ¼ inch/31 mm drain valves. 4 – 8 inch/114.3 – 219.1 mm configurations contain 2 inch/50 mm drain valves. A J A1 H G *B1 K C E F D B SYSTEM TRIM DIMENSIONS 30.85_5 30.85FIRE PROTECTION PRODUCTS – DEVICES SERIES 769Double-Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim Size Dimensions – inches/mm Aprx. Weight Ea. lbs/kg Nominal Sizeinchesmm Actual Out. Dia. inchesmm A A1 B B1* C D E F G* H J K Without Trim With Trim 1½ 1.900 9.08 16.46 38.00 48.00 11.00 20.50 9.50 13.75 29.75 3.04 8.99 7.18 16.7 43.040 48.3 230.6 418.1 965.2 1219.2 279.4 520.7 241.3 349.3 755.7 77.2 228.3 182.4 7.6 19.5 2 2.375 9.08 16.46 38.00 48.00 11.00 20.50 9.50 13.75 29.75 3.04 8.99 7.18 17.0 43.050 60.3 230.6 418.1 965.2 1219.2 279.4 520.7 241.3 349.3 755.7 77.2 228.3 182.4 7.7 19.5 2 ½ 2.875 12.70 16.63 41.50 51.50 11.50 22.50 11.00 13.25 28.00 3.95 10.78 6.97 41.0 65.065 73.0 322.6 422.4 1054.1 1308.1 292.1 571.5 279.4 336.6 711.2 100.3 273.8 177.0 18.7 29.5 76.1 mm 3.000 12.70 16.63 41.50 51.50 11.50 22.50 11.00 13.25 28.00 3.95 10.78 6.97 41.0 65.076.1 322.6 422.4 1054.1 1308.1 292.1 571.5 279.4 336.6 711.2 100.3 273.8 177.0 18.7 29.5 3 3.500 12.70 16.63 41.50 51.50 11.50 22.50 11.00 13.25 28.00 3.95 10.78 6.97 41.0 65.080 88.9 322.6 422.4 1054.1 1308.1 292.1 571.5 279.4 336.6 711.2 100.3 273.8 177.0 18.7 29.5 4 4.500 15.15 19.96 42.25 52.50 13.50 23.25 11.25 15.00 27.75 6.30 9.51 8.10 59.0 95.0100 114.3 384.8 507.0 1073.2 1333.5 342.9 590.6 285.8 381.0 704.9 160.0 241.6 205.7 26.7 43.0 165.1 mm 6.500 16.13 22.17 42.50 52.75 14.00 27.25 11.75 15.75 27.00 6.30 9.49 8.43 80.0 116.0165.1 409.7 563.1 1079.5 1339.9 355.6 692.2 298.5 400.1 685.8 160.0 241.0 214.1 36.2 52.6 6 6.625 16.13 22.17 42.50 52.75 14.00 27.25 11.75 15.75 27.00 6.30 9.49 8.43 80.0 116.0150 168.3 409.7 563.1 1079.5 1339.9 355.6 692.2 298.5 400.1 685.8 160.0 241.0 214.1 36.2 52.6 8 8.625 17.63 23.09 42.25 52.25 15.25 29.75 12.75 16.50 25.50 6.30 9.27 9.79 122.0 158.0200 219.1 447.8 586.5 1073.2 1327.2 387.4 755.7 323.9 419.1 647.7 160.0 235.5 248.7 55.3 71.6 The “A” dimension coupling is not shown for clarity. Components shown as dotted lines denote optional equipment * Measurements denoted with an asterisk take optional equipment into account The 4inch/114.3 mm configuration is shown above 1 ½ – 2 inch/48.3 – 60.3 mm configurations contain ¾inch/19 mm drain valves. 2 ½ – 3 inch/73.0 – 88.9 mm configurations contain 1 ¼ inch/31 mm drain valves. 4 – 8 inch/114.3 – 219.1 mm configurations contain 2 inch/50 mm drain valves. SYSTEM TRIM DIMENSIONS A J A1 H G* B1* E K C B F D 30.85_6 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Electric Activation with Redundant Solenoid Valve and Autoconvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A SYSTEM TRIM DIMENSIONS 30.85_7 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Double-Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim A J A1 H B *G *B1 E K C F D Size Dimensions – inches/mm Aprx. Weight Ea. lbs/kg Nominal Sizeinchesmm Actual Out. Dia. inchesmm A A1 B B1* C D E F G* H J K Without Trim With Trim 1½ 1.900 9.00 16.43 38.00 48.00 13.50 22.00 9.50 15.25 29.75 3.04 8.99 7.63 16.7 43.040 48.3 228.60 417.32 965.2 1219.2 342.9 558.8 241.3 387.4 755.7 77.2 228.3 193.8 7.6 19.5 2 2.375 9.00 16.43 38.00 48.00 13.50 22.00 9.50 15.25 29.75 3.04 8.99 7.63 17.0 43.050 60.3 228.60 417.32 965.2 1219.2 342.9 558.8 241.3 387.4 755.7 77.2 228.3 193.8 7.7 19.5 2 ½ 2.875 12.61 16.50 41.50 51.50 12.50 21.75 11.00 14.75 28.00 3.95 10.78 6.97 41.0 65.065 73.0 320.29 419.10 1054.1 1308.1 317.5 552.5 279.4 374.7 711.2 100.3 273.8 177.0 18.7 29.5 76.1 mm 3.000 12.61 16.50 41.50 51.50 12.50 21.75 11.00 14.75 28.00 3.95 10.78 6.97 41.0 65.076.1 320.29 419.10 1054.1 1308.1 317.5 552.5 279.4 374.7 711.2 100.3 273.8 177.0 18.7 29.5 3 3.500 12.61 16.50 41.50 51.50 12.50 21.75 11.00 14.75 28.00 3.95 10.78 6.97 41.0 65.080 88.9 320.29 419.10 1054.1 1308.1 317.5 552.5 279.4 374.7 711.2 100.3 273.8 177.0 18.7 29.5 4 4.500 15.03 19.78 42.25 52.50 14.25 24.75 11.25 16.50 27.75 6.30 9.51 8.50 59.0 95.0100 114.3 381.76 502.41 1073.2 1333.5 362.0 628.7 285.8 419.1 704.9 160.0 241.6 215.9 26.7 43.0 165.1 mm 6.500 16.00 22.00 42.50 52.75 14.50 28.75 11.75 17.25 27.00 6.30 6.04 8.89 80.0 116.0165.1 406.40 558.80 1079.5 1339.9 368.3 730.3 298.5 438.2 685.8 160.0 153.4 225.8 36.2 52.6 6 6.625 16.00 22.00 42.50 52.75 14.50 28.75 11.75 17.25 27.00 6.30 6.04 8.89 80.0 116.0150 168.3 406.40 558.80 1079.5 1339.9 368.3 730.3 298.5 438.2 685.8 160.0 153.4 225.8 36.2 52.6 8 8.625 17.50 22.94 42.25 52.50 16.00 31.25 13.00 18.00 25.50 6.30 9.27 10.26 122.0 158.0200 219.1 444.50 582.67 1073.2 1333.5 406.4 793.8 330.2 457.2 647.7 160.0 235.5 260.6 55.3 71.6 The “A” dimension coupling is not shown for clarity. Components shown as dotted lines denote optional equipment * Measurements denoted with an asterisk take optional equipment into account The 4inch/114.3 mm configuration is shown above 1 ½ – 2 inch/48.3 – 60.3 mm configurations contain ¾inch/19 mm drain valves. 2 ½ – 3 inch/73.0 – 88.9 mm configurations contain 1 ¼ inch/31 mm drain valves. 4 – 8 inch/114.3 – 219.1 mm configurations contain 2 inch/50 mm drain valves. PERFORMANCE Hydraulic Friction Loss The chart below expresses the flow of water at 65ºF/18ºC through a full open valve. Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 769 FireLock NXT Preaction Valve in equivalent feet of straight pipe. Size Equivalent Length of Pipe NominalSizeInches/mm ActualOutside Dia.Inches/mm Feetmeters 1 ½1.900 3.0040 48.3 0.914 2 2.375 9.0050 60.3 2.743 2 ½2.875 8.0065 73.0 2.438 76.1 mm 3.000 8.0076.1 2.439 3 3.500 17.0080 88.9 5.182 4 4.500 21.00100 114.3 6.401 165.1 mm 6.500 22.00165.1 6.706 6 6.625 22.00150 168.3 6.706 8 8.625 50.00200 219.1 15.240PRESSURE DROP – PSI FLOW RATE – GPM 800 3,000 8,000 6.05.04.0 3.0 2.0 1.00.90.80.70.60.50.4 0.3 0.2 0.110 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,0003"/80mm 4"/10 0 m m 6"/150mm and 165.1mm8"/200mm2½"/65 m m a nd 7 6.1 m m 1½"/40mm2"/50mm30.85_8 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A Cv VALUES Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. Formulas for Cv values: Size NominalSizeInches/mm ActualOutside Dia.Inches/mm Cv/Kv(Fully Open Valve) 1 ½1.900 6040 48.3 52.0 2 2.375 11050 60.3 95.0 2 ½2.875 18065 73.0 156.0 76.1 mm 3.000 18076.1 156.0 3 3.500 20080 88.9 173.0 4 4.500 350100 114.3 302.8 165.1 mm 6.500 1000165.1 865.0 6 6.625 1000150 168.3 865.0 8 8.625 1500200 219.1 1499.1 P = Q 2 Cv2 Where: Q = Flow (GPM) P = Pressure Drop (psi) Cv = Flow CoecientQ = Cv x P OPERATION The Victaulic Preaction System utilizes the Series 769 Preaction Valve to control the entry of the water supply into the Preaction System piping and sprinklers. The Series 769 Preaction Valve is constructed with a clapper having a replaceable rubber face. The clapper makes contact with the valve seat ring which has access holes to the intermediate chamber of the valve. The clapper is contacted by the latch which is contacted by the diaphragm. In the set position, water supply pres- sure from upstream of the water supply control valve is maintained in the diaphragm chamber which holds the clapper in the closed/set position. The water is maintained in the diaphragm by one of the system release mechanisms. Upon the detection of an appropriate actuating event of the Preaction System (see system description on pages 2-3) the water supply pressure in the diaphragm chamber is released. This release allows the latch to move to its open position, permitting the clapper to pivot freely, thus allowing water into the system. Water will flow from all open sprinklers in the piping. Also, water enters the intermediate chamber of the valve through the holes in the seat ring. The water flows from the intermediate chamber to the alarm line thus activating the system alarms. These alarms will continue to sound until the flow of water is stopped. When the flow of water is stopped the spring assisted valve clapper returns to the closed position and the valve acts as an alarm check valve until the system is put back into service as a Preaction System. Manual Operation Any time the manual release handle is pulled water will be released from the diaphragm chamber and the valve will actuate, allowing water into the Preaction System. Water motor alarms and alarm pressure switches will activate. 30.85_9 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, grade 65-45-12. Clapper: Aluminum bronze UNS-C95500 Latch: Aluminum bronze UNS-C95500 Clapper Seal: Peroxide cured EPDM, ASTM D2000 Bushing and Seat O-rings: Nitrile Springs: Stainless steel (300 Series) Shafts: Stainless 17-4 Diaphragm: Peroxide cured EPDM with fabric reinforcement Bill of Materials 1 Valve Body 12 Cover Plate 2 Clapper 13 Cover Plate Gasket 3 Clapper Seal 14 Cover Plate Bolts* 4 Seal Ring 15 Latch 5 Seal Washer 16 Latch Spring 6 Seal Retaining Ring 17 Latch Shaft Bushing and O-Ring (Qty. 2) 7 Seal Assembly Bolt 18 Diaphragm 8 Bolt Seal 19 Diaphragm Cover 9 Clapper Spring 20 Diaphragm Cover Cap Screws (Qty. 8) 10 Clapper Shaft 21 Latch Shaft 11 Clapper Shaft Bushing and O-Ring (Qty. 2) 1 12 11 17 17 11 21 20 9 4 3 10 18 19 7 8 15 16 14 13 2 5 6 * NOTE: The 1½-inch/48.3-mm and 2-inch/60.3-mm valve sizes contain washers under the heads of the cover plate bolts. Exaggerated for clarity 30.85_10 30.85FIRE PROTECTION PRODUCTS – DEVICES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim TRIM PACKAGES Trim Packages Options: 1 Electric Activation with Redundant Solenoid Valve 2 Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Interlock Trim 3 Double-Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve 4 Double-Interlocked Pneumatic/Electric Activation with Redundant Solenoid valve and AutoConvert Dry Trim Trim packages include all required galvanized pipe and fittings. For trim package details and optional accessories, see pages 17-20 Actuators: • Series 776 Low-Pressure Actuator – The Series 776 Low-Pressure Actuator is pneumati- cally actuated and requires only 13 psi/90 kPa minimum air pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low air or gas pressure of 7 psi/48 kPa. Request submittal 30.46. • Series 767 Electric/Pneumatic Actuator – The Series 767 Electric/Pneumatic Actuator provides a single trip point for the pneumatic event and an integral electric actuator. This actuator requires only 13 psi/90 kPa minimum air pressure, regardless of the system sup- ply pressure. This actuator allows the system to operate with a low air or gas pressure of 7 psi/48 kPa. Request submittal 30.62. • Series 753-E Solenoid Valve – The Series 753-E Solenoid Valve is designed for use with systems that require electrical activation. Request submittal 30.32. - Redundant solenoid made by alternate manufacturer required by LPCB Approval Optional accessories: • Series 746-LPA Dry Accelerator – The Series 746-LPA Dry Accelerator can be used on pneumatic release systems to improve response time. Request submittal 30.64. • Series 760 Water Motor Alarm – The Series 760 Water Motor Alarm is a mechanical device that sounds when a sustained flow of water occurs (such as with an open sprinkler). Request submittal 30.32. • Series 75B Supplemental Alarm Device – The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Request submittal 30.33. • Series 75D Water Column Kit – The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Request submittal 30.34. • Air Compressor • Air Maintenance Trim Assembly • Fire Alarm Control Panel (FACP) 30.85_11 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A F AIR SUPPLY REQUIREMENTS The required air pressure for Series 769 FireLock NXT Preaction Valves is 13 psi/90 kPa minimum, regardless of the system supply pressure. Air pressures should be kept below 18 psi/124 kPa, unless a Series 746-LPA Dry Accelerator is installed. Systems with air pressures higher than 18 psi/124 kPa may require the addition of a Series 746-LPA Dry Accelerator. If multiple Series 769 FireLock NXT Preaction Valves are installed with a common air supply, isolate the systems with a spring-loaded, soft-seated ball check valve to ensure air integrity for each system. Good practice is to include a ball valve for isolation and service of each individual system. Set the air pressure to the required system air pressure. Air pressure differing from the required sys- tem air pressure could reduce system operation response time. The engineer/system designer is responsible for sizing the compressor so that the entire system is charged to the required air pressure within 30 minutes. DO NOT oversize the compressor to provide more airflow. An oversized compressor will slow down or possibly prevent valve operation. If the compressor fills the system too fast, it may be necessary to restrict the air supply. Restricting the air supply will ensure that air being exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is being exhausted. COMPRESSOR SIZING 0 2 4 6 8 10 12 SYSTEM CAPACITY (in gallons)REQUIRED FLOW RATE (CFM)COMPRESSOR REQUIREMENTS 55030050800105013001550180020 psi/138 kPa 13 psi/90 kPa 30.85_12 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A BASE OR RISER-MOUNTED COMPRESSORS For base or riser-mounted compressors, the recommended air pressure of 13 psi/90 kPa is the “on” or “low” pressure setting for the compressor. The “off” or “high” pressure setting should be 18 psi/124 kPa. When a base or riser-mounted air compressor supplies air to a Series 769 FireLock NXT Preaction Valve, do not install the Victaulic Series 757 Regulated Air Maintenance Trim Assembly (AMTA). In this case, the airline of the compressor connects to the valve trim at the air manifold (refer to the applicable trim drawing). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with Pressure Switch should be installed. For information on the Series 757 Regulated Air Maintenance Trim Assembly, see publication 30.35. For information on the Series 757P Air Maintenance Trim Assembly, see publication 30.36. NOTE: The Series 757P AMTA must NOT be used in any system installed with a Series 746-LPA Dry Accelerator, unless a tank and an air regulator are added. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor p rovides the the greatest protection for systems. When shop air or a tank-mounted air compressor is used, the Series 757 Regulated AMTA must be installed. The Series 757 Regulated AMTA provides proper air regulation from the air reservoir to the sprinkler system. For tank-mounted air compressors, the recommended air pressure of 13 psi/90 kPa should be used as the set point for the air regulator. The “on” pressure of the compressor should be at least 5 psi/ 34 kPa above the set point of the air regulator. SHOP AIR OR TANK-MOUNTED AIR COMPRESSORS 30.85_13 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A SERIES 757 REGULATED AIR MAINTENANCE TRIM ASSEMBLY 1 6 5 4 2 3 Bill of Materials 1 ⁄"/3.2 mm Restrictor 2 Slow Fill Ball Valve (Normally Open) 3 Air Regulator 4 Strainer (100 Mesh) 5 Spring-Loaded, Soft-Seated Ball Check Valve 6 Fast Fill Ball Valve (Normally Closed) SERIES 757P AIR MAINTENANCE TRIM ASSEMBLY WITH PRESSURE SWITCH NOTICE • Victaulic recommends a maximum of two Series 769 FireLock NXT Preaction Valves per Series 757 Regulated AMTA NOTICE • Victaulic recommends a maximum of two Series 769 FireLo ck NXT Preaction Valves per Series 757P AMTA with Pressure Switch. Exaggerated for clarity Exaggerated for clarity 5 2 12 7 8 15 10 16 9 6 4 1 13 3 14 11 TOSYSTEM FROM COMPRESSOR Bill of MaterialsItem Qty. Description 1 1 Restrictor (½-inch NPT) 2 1 Strainer (½-inch NPT) 3 1 Swing Check (½-inch NPT) 4 1 Slow-Fill Ball Valve (Normally Open) 5 1 Spring-Loaded, Soft-Seated Check Valve 6 1 Pressure Switch 7 2 Compression Fitting, Straight (¼-inch NPT x ¼-inch Tube) 8 1 Copper Tubing (¼-inch OD) 9 11 Close Nipple (½-inch NPT x 1.13) 10 1 Nipple (½-inch NPT x 4.00) 11 1 90° Female Elbow (½-inch NPT) 12 4 Female Tee (½-inch NPT) 13 3 Union (½-inch NPT) 14 2 Reducing Bushing (½-inch NPT x ¼-inch NPT) 15 1 Fast-Fill Ball Valve (Normally Closed) 16 1 Pressure Switch Isolation Ball Valve (Normally Open - Lockable) 30.85_14 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A COMPRESSOR REQUIREMENTS AND SETTINGS FOR SERIES 769 FIRELOCK NXT PREACTION VALVES INSTALLED WITH SERIES 746-LPA DRY ACCELERATORS A tank-mounted air compressor with a Series 757 Regulated AMTA must be used to supply air to a Series 769 FireLock NXT Preaction Valve installed with a Series 746-LPA Dry Accelerator. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection, since air can be supplied continuously to the sprinkler system for an extended time period. In addition, a properly-sized tank-mounted air compressor prevents clogging of the dry accelerator’s orifice. Set the air regulator of the Series 757 Regulated AMTA to a minimum of 0.9 Bar/13 psi. The air regulator of the Series 757 Regulated AMTA is a relief-type design. Any pressure in the system that is above the set point of the air regulator will be released. Therefore, charging the air regulator above the set point could cause premature operation of a valve installed with a Series 746-LPA Dry Accelerator. 1. Air supervisory pressure switches are required for preaction systems and must be set according to the following notes. NOTE: Switches for Vic-Quick Risers are pre-set at the factory. • a. Wire the air supervisory pressure switches to activate a low-pressure alarm signal. NOTE: In addition, the local authority having jurisdiction may require a high-pressure alarm. Contact the local authority having jurisdiction for this requirement. • b. Set the air supervisory pressure switches to activate at 0.1 – 0.3 Bar/2 – 4 psi below the minimum air pressure required (but not lower than 0.7 Bar/10 psi). • c. Wire the alarm pressure switch to activate a water flow alarm. • d. Set the alarm pressure switch to activate on a pressure rise of 0.3 – 0.6 Bar/4 – 8 psi above the pressure required. • e. System also includes a low water alarm pressure switch that is factory set and trips on falling pressure of less than 124 kPa/18 psi. Trip level can be field adjusted higher if necessary. SETTINGS FOR AIR SUPERVISORY PRESSURE SWITCHES AND ALARM PRESSURE SWITCHES The remote system test valve (inspector’s test connection) should contain a normally closed valve, which can be opened to simulate the operation of a sprinkler. The remote system test valve (inspector’s test connection) should be located at the most hydrauli- cally demanding location in the release system. NOTE: Multiple restrictions on the remote system test valve (inspector’s test connection) may slow the air decay rate and cause the system to respond slower than required. The remote system test valve (inspector’s test connection) should terminate with an orifice equal to the smallest orifice in the releasing system. The remote system test valve (inspector’s test connection) is used to ensure that water reaches the most remote part of the system within the required time. REMOTE SYSTEM TEST VALVE REQUIREMENTS 30.85_15 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With: - Electric Activation with Redundant Solenoid Valve - Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve - Double Interlocked Pneumatic/Electric Activation with Redundant Solenoid Valve and AutoConvert Dry Trim www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A 10 From WaterSupply 2 3 1 18 20 19 14 17 19 15 16 21 22 To System 24 26 23 To Drip Cup Locationor Drain To Drip CupLocationor Drain Standard Conguration Assembly (See Exploded View on Opposite Page) Note 1 Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open - Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve (Normally Closed - Lockable) 12 Diaphragm-Charge-Line Pressure Gauge (0-25 Bar/0-350 psi) 13 Series 749 Auto Drain 14 Air Supervisory Pressure Switch 15 System Pressure Gauge (0-16 Bar with Mark Pointers) 16 Water Supply Main Drain Valve - Flow Test 17 Water Supply Pressure Gauge (0-25 Bar/0-350 psi) 18 Drain Connection Kit 19 Gauge Valve 20 System Main Drain Valve 21 Series 755 Manual Pull Station 22 Series 748 Ball Check Valve 23 Solenoid Valve 24 Low Water Pressure Switch 25 Water Motor Alarm Shutoff Valve (Normally Open - Lockable)* 26 Series 753-E Solenoid Valve * Item 33, water motor alarm shutoff valve, can be closed to prevent water from flowing into the Series 760 Water Motor Alarm during conditions that are not favorable for the alarm to sound (i.e. during a trip test). Exaggerated for clarity 30.85_16 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Electric Release with Redundant Solenoid Valve (Optional accessories also shown) www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A Exaggerated for clarity Standard Conguration Assembly (See Exploded View on Page 18)10 Series 767 Electric/Pneumatic Actuator and Redundant Solenoid Assembly(See Exploded View on Page 18) From WaterSupply 2 3 1 20 22 21 16 19 21 17 18 23 24 To System 32 Note 1 Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open - Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve (Normally Closed - Lockable) 12 Diaphragm-Charge-Line Pressure Gauge (0-25 Bar/0-350 psi) 13 Series 749 Auto Drain 14 Series 767 Electric/Pneumatic Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-16 Bar with Mark Pointers) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-25 Bar/0-350 psi) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve 25 Series 746-LPA Dry Accelerator (Optional/Sold Separately) 26 Upper Chamber Strainer (100 Mesh) for Series 767 Electric/Pneumatic Actuator 27 Upper Chamber Pressure Gauge for Series 767 Electric/Pneumatic Actuator 28 Auto Vent for Series 767 Electric/ Pneumatic Actuator 29 Upper Chamber Inlet Restrictor (0.8-mm/.032-inch) for Series 767 Electric/ Pneumatic Actuator 30 Upper Chamber Check Valve (6.4-mm/¼-inch) for Series 767 Electric/Pneumatic Actuator 31 Solenoid Valve 32 Low Water Pressure Switch 33 Water Motor Alarm Shutoff Valve (Normally Open - Lockable)* * Item 33, water motor alarm shutoff valve, can be closed to prevent water from flowing into the Series 760 Water Motor Alarm during conditions that are not favorable for the alarm to sound (i.e. during a trip test). See Standard Configuration Assembly detail on page 18. Note 1: Connection point for the Series 75D Water Column Device Kit 30.85_17 30.85FIRE PROTECTION PRODUCTS – DEVICES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Double-Interlocked, Electric/Pneumatic Release Trim with Redundant Solenoid Valve (Optional accessories also shown) To Optional Water Motor Alarm To DiaphragmHousing From Water Supply From DiaphragmHousing To Lower Port of Water Supply Main Drain Valve From Alarm Port of Preaction Valve Body When a supplemental alarm device is required, remove plug and attach alarm feed here When installing a Manual Pull Station, remove plug and connect to tting To Drip Cup Locationor Drain Location To Drip Cup Locationor Drain 11 13 6 12 8 4 7 9 5 Exploded View of StandardConguration Assembly To Drain Connection Assembly or Drain LocationTo System Actuator Exploded View of Series 767 Electric/Pneumatic Actuatorand Redundant Solenoid Assembly From SystemAir Feed 25 28 NOTE: When installing the optional Series 746-LPA Dry Accelerator, relocate the auto vent to the location of the indicated plug. 15 When installing a Manual Pull Station, remove plug and connect to tting. To Drip Cup Locationor Drain From StandardConguration AssemblyLocation To Drip Cup Locationor Drain 27 29 30 26 31 14 To System MainDrain Valve 21 33 25a 25b 30.85_18 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Exploded Views: - Series 767 Electric/Pneumatic Actuator and Redundant Solenoid Assembly - Standard Configuration Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A Exaggerated for clarity From WaterSupply 2 3 1 18 20 19 14 17 19 15 16 10 21 22 To System 24 30 32 Standard Conguration Assembly (See Exploded View on Opposite Page) AutoConvert Trim Assembly (See Exploded View on Opposite Page) Note 1 Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open - Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve (Normally Closed - Lockable) 12 Diaphragm-Charge-Line Pressure Gauge (0-25 Bar/0-350 psi) 13 Series 749 Auto Drain 14 Air Supervisory Pressure Switch 15 System Pressure Gauge (0-16 Bar with Mark Pointers) 16 Water Supply Main Drain Valve - Flow Test 17 Water Supply Pressure Gauge (0-25 Bar/0-350 psi) 18 Drain Connection Kit 19 Gauge Valve 20 System Main Drain Valve 21 Series 755 Manual Pull Station 22 Series 748 Ball Check Valve 23 Series 746-LPA Dry Accelerator (Optional/Sold Separately) 24 Series 753-E Solenoid Valve 25 Latching Solenoid Assembly 26 Braided Stainless Steel Flex Hose 27 Series 776 Low-Pressure Actuator 28 AutoConvert Assembly Air Pressure Gauge (0-5.5 Bar/0-80 psi with Retard) 29 Strainer 30 Solenoid Valve 31 Water Motor Alarm Shutoff Valve (Normally Open - Lockable)* 32 Low Water Pressure Switch 33 AutoConvert Assembly Pre-Set Air Pressure Switch * Item 31, water motor alarm shutoff valve, can be closed to prevent water from flowing into the Series 760 Water Motor Alarm during conditions that are not favorable for the alarm to sound (i.e. during a trip test). Note 1: Connection point for the Series 75D Water Column Device Kit 30.85_19 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Electric Autoconvert Dry Trim with Redundant Solenoid Valve (Optional accessories also shown) www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A To Optional Water Motor Alarm 31 To DiaphragmHousing From Water Supply From DiaphragmHousing To Drain Connection Assembly or Drain Remove this plug when installing an optional pressure switch. To Lower Port of Water Supply Main Drain Valve From Alarm Port of Preaction Valve Body When a supplemental alarm device is required, remove plug and attach alarm feed here To Drip Cup Locationor Drain LocationTo Drip Cup Locationor Drain Exploded View of AutoConvertTrim Assembly To System Main Drain Valve From SystemAir Feed The exible hose can be re-oriented, as required, by rotating the ½-inch NPT tee 90° From Series 753-ESolenoid Valve When installing an optional Dry Accelerator, re-locate the gauge, as indicated. Replace the ¼-inch NPT close nipple with a ¼-inch NPT x 2-inch nipple to ensure clearance between the gauge and ball valve.26 To Drip Cup Locationor Drain 28 29 23 9 25 27 19 11 13 6 12 8 4 7 9 5 Exploded View of StandardConguration Assembly 19 19 33 To AutoConvert Trim Assembly To Series 753-E Solenoid Valve 23a 23b 30.85_20 30.85FIRE PROTECTION PRODUCTS – DEVICES FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Exploded View of Auto Convert Trim Assembly (Optional accessories also shown) www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A Exaggerated for clarity Bill of Materials 1 Series 769 FireLock NXT Preaction Valve 2 FireLock Rigid Coupling 3 Water Supply Main Control Valve 4 Drain Swing Check Valve 5 Drip Cup with Cap 6 Alarm Pressure Switch 7 Series 729 Drip Check Valve 8 Diaphragm-Charge-Line Ball Valve (Normally Open - Lockable) 9 3-in-1 Strainer/Check/Restrictor Assembly 10 Series 760 Water Motor Alarm (Optional/Sold Separately) 11 Alarm Test Ball Valve (Normally Closed - Lockable) 12 Diaphragm-Charge-Line Pressure Gauge (0-25 Bar/0-350 psi) 13 Series 749 Auto Drain 14 Series 767 Electric/Pneumatic Actuator 15 Air Manifold 16 Air Supervisory Pressure Switch 17 System Pressure Gauge (0-16 Bar with Mark Pointers) 18 Water Supply Main Drain Valve - Flow Test 19 Water Supply Pressure Gauge (0-25 Bar/0-350 psi) 20 Drain Connection Kit 21 Gauge Valve 22 System Main Drain Valve 23 Series 755 Manual Pull Station 24 Series 748 Ball Check Valve 25 Series 746-LPA Dry Accelerator (Optional/Sold Separately) 26 Upper Chamber Strainer (100 Mesh) for Series 767 Electric/Pneumatic Actuator 27 Upper Chamber Pressure Gauge for Series 767 Electric/Pneumatic Actuator 28 Auto Vent for Series 767 Electric/ Pneumatic Actuator 29 Upper Chamber Inlet Restrictor (0.8-mm/.032-inch) for Series 767 Electric/ Pneumatic Actuator 30 Upper Chamber Check Valve (6.4-mm/¼-inch) for Series 767 Electric/Pneumatic Actuator 31 Latching Solenoid Module 32 Braided Stainless Steel Flex Hose 33 Series 776 Low-Pressure Actuator 34 AutoConvert Assembly Air Pressure Gauge (0-5.5 Bar/0-80 psi with Retard)35 Strainer36 Water Motor Alarm Shutoff Valve (Normally Open - Lockable)* 37 Low Water Pressure Switch 38 Solenoid Valve 39 AutoConvert Assembly Pre-Set Air Pressure Switch* Item 36, water motor alarm shutoff valve, can be closed to prevent water from flowing into the Series 760 Water Motor Alarm during conditions that are not favorable for the alarm to sound (i.e. during a trip test). 10 From WaterSupply 2 3 1 20 22 21 16 19 21 17 18 23 24 To System 37 Standard Conguration Assembly (See Exploded View on Page 18) AutoConvert Trim Assembly (See Exploded View on Page 18) Series 767 Electric/Pneumatic Actuator with Redundant Solenoid Valve Assembly (See Exploded View on Page 18) Note 1 Note 1: Connection point for the Series 75D Water Column Device Kit See Standard Configuration Assembly detail on page 18. 30.85_21 30.85FIRE PROTECTION PRODUCTS – DEVICES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_A FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769Double-Interlocked, Electric/Pneumatic Autoconvert Dry Trim with Redundant Solenoid Valve (Optional accessories also shown) 30.85 FireLock NXT™ Actuated Valve with LPCB Approved Preaction Trim SERIES 769With Preaction TrimGrooved x Grooved 30.85FIRE PROTECTION PRODUCTS – DEVICES For complete contact information, visit www.victaulic.com 30.85 5780 REV A UPDATED 7/2010 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE WARNING •Thisproductmustbeinstalledbyanexperienced,trainedinstaller, in accordance with the instructions provided with each valve. These instructions contain important information. Failuretofollowtheseinstructionsmayresultinseriouspersonalinjury, propertydamage,orvalveleakage. If you need additional copies of this product literature or the valve installationinstructions,orifyouhaveanyquestionsaboutthesafe installationanduseofthisdevice,contactVictaulicCompany,P.O. Box31,Easton,PA18044-0031USA,Telephone:001-610-559-3300. WARNING