HomeMy WebLinkAboutBermad FP-700-Engineering-final.pdfBERMAD Fire Protection 700 Series 700E Deluge Valve Data Description BERMAD 700E Deluge Valves are Y Type globe valves with integral unitized double chamber actuator that consists of one single moving assembly, which includes a diaphragm assembly, a flat seal disk and a stainless steel removable seat. These automatic water control valves are designed for high pressure service, in vertical or horizontal installations and are available in diameter sizes from 1½” to 16”; DN40 to DN400. The BERMAD 700E valves are used for water flow control in Deluge, Pressure Control Deluge, Preaction or Water/ Foam systems, and are manufactured from materials suitable for freshwater or alternative for seawater, foam concentrate or other corrosive fluids. The 700E Deluge Valve is held closed by system water pressure trapped in the control chamber. When the releasing system operates, pressure is released from the control chamber, and the seal disc opens to allow water to flow into the system. The 700E valve body design includes a single, full bore seat with unobstructed flow path, free of any in-line ribs, supporting cage, or stem guides. The 700E “Y Type” design provides high flow capabilities with minimum head loss. The integral unitized double-chambered actuator provides a combination of positive, immediate response with smooth hammer-free, drip-tight closing. The whole actuator can be easily removed for a quick in-line inspection and servicing. Valve actuation is accomplished by one moving assembly which includes a replaceable flat diaphragm, harnessed to the diaphragm assembly, a stainless steel stem and a flat seal disk assembly. The balanced seal-disk assembly with its resilient seal enables controlled actuation, high durability and perfect drip-tight sealing, even under harsh conditions. Accessories The BERMAD 700E Deluge Valve shall be trimmed with the original components and accessories per specification and in accordance with valve functions and applications. Where additional specifications and/or signaling devices are required for a specific application, refer to system data for the system used, and to the BERMAD data sheet and Installation, Operation & Maintenance for specific model required. Main Features ■ High Pressure Construction – 400 psi (28 bar) rating available ■ Integral unitized double chamber actuator with single moving assembly ■ In-line serviceable, field replaceable internals ■ Obstacle free, full bore ■ Available in corrosion resistant materials ■ Designed to be reset without opening the valve ■ Compatible with electric/hydraulic/pneumatic release and pressure control trim systems Approvals ■ UL Listed to UL 260 from 5 to 300 psi; 0.3 to 21 bar WP, 2” through 10”; DN50 through DN250 ■ ABS Approved for 300 psi; 21 bar WP, 1½” through 12”; DN40 through DN300 ■ Lloyd’s Register Type Approval for 300 psi; 21 bar WP, 1½” through 16”; DN40 through DN400 ■ Fire Test Certified to ISO 6182 part 5, 1½” through 16”; DN40 through DN400 Notes: 1. The 700E valve shall be trimmed with specific components & accessories. 2. The 700E valve must be installed and maintained in compliance with the most recent BERMAD publications. 1 BERMAD Fire Protection 700 Series700E Materials Specifications Construction Materials The BERMAD 700E valves are available in a variety of materials to ensure optimal suitability for a wide range of applications. For operation involving exposure to internal and/or external corrosive conditions, valves are constructed from corrosion-resistant materials making them suitable for use with seawater, brackish water, or corrosive environments such as seashore, petrochemical and other industrial facilities. Standard Configurations Item Number Description Firewater Valve 1 Cover Ductile Iron 2 Cover Bolt Stainless Steel 3 Cover Nut Stainless Steel 4 Separation Partition Ductile Iron 5 Stud Z.C. Plated Steel 6 Stud Nut Z.C. Plated Steel 7 Valve Body Ductile Iron 8 Spring S.S. 302 9 Removable Seat S.S. 304 10 Seal NBR (Buna-N) 11 Upper Plug (6-20”)Brass 12 Shaft Lock Nut S.S. 303 13 Shaft Nut S.S. 303 14 Diaphragm Washers S.S. 431 15 Diaphragm NBR (Buna-N) 16 Bearing Screw S.S. 303 17 Bearing Bronze 18 Shaft S.S. 303 19 Seal Disk S.S. 431 Specifications Castings ■ Ductile Iron to ASTM A536 65-45-12 (coated) ■ Cast Steel ASTM A216 Grade WCB (coated) ■ Nickel Aluminum Bronze ASTM B148 C95800 ■ Stainless Steel 316 ASTM A351 Grade CF8M ■ Super Duplex ASTM A890 Grade 5A ■ Hastelloy C-276 Bolting: ■ External Bolting: S.S.316 to ASTM A320 Gr.B8F Internal Wetted Parts: ■ Stainless Steel 303 ASTM A582 95B S30300A ■ Stainless Steel 304 ASTM A743 Grade CF8 ■ Stainless Steel 431 ASTM A743 Grade CA15M ■ Bronze ASTM B505 Grade C83600 ■ Internal Spring - S.S. 302 Optional Internal Wetted Parts: ■ Stainless Steel 316 ASTM A351 Grade CF8M ■ Nickel Aluminum Bronze ASTM B148 C95800 ■ Monel 400 ■ Super Duplex ASTM A890 Grade 5A ■ Hastelloy C-276 ■ Internal Spring - Inconel Elastomers (Diaphragm & Seals) ■ NBR, Polyamide fabric reinforced Nitrile (Buna-N), Temperature Rating 80°C ■ EPDM, Polyamide fabric reinforced Ethylene-Propylene, Temperature Rating 90°C Coating ■ Electrostatic Powder Coating Polyester ■ High Built Epoxy Fusion-Bonded with UV Protection, Anti-Corrosion ■ Color: Fire Red to RAL 3002 Note: Internal & External coating applied on Ductile Iron or Cast Steel Castings only. Material End Connection StandardInlet & Outlet Class & Type Max. working pressure psi bar Ductile Iron Flanged ANSI B16.42 #150RF 250 17.4 Flanged ANSI B16.42 #300RF 400 28 Flanged ISO 7005-2 PN 16 235 16 Flanged ISO 7005-2 PN 25 365 25 Grooved ANSI C606 300 400 25 Threaded BSP/NPT 300/PN25 400 25 C.Steel, SS316, Duplex & Hastelloy Flanged ANSI B16.5 #150RF 250 17.4 Flanged ANSI B16.5 #300RF 400 28 Flanged ISO 7005-2 PN16 235 16 Flanged ISO 7005-2 PN25 365 25 Threaded BSP/NPT 300/PN25 400 25 Ni-Al Bronze Flanged ANSI B16.24 #150RF 250 17.4 Flanged ANSI B16.24 #300RF 400 28 Flanged ISO 7005-2 PN 16 235 16 Flanged ISO 7005-2 PN25 365 25 Notes 1. Factory pressure testing: Each valve is tested at 1.6 of pressure rating.2. Water Temperature: 0.5 - 80ºC (33 - 122ºF)3. Standard flange facing: Raised Face (RF), Serrated Finish. Flat Face (FF) flanges available on request. Pressure Rating 2 1 2 3 4 5 6 7 8 9 10 9 19 18 17 16 15 14 13 12 11 BERMAD Fire Protection 700 SeriesFP 700E Flow & Hydraulic Data gpm Flow RatePressure Loss0.1 1.0 10 100 1,000 0.5 40 65 50 500 5,000 psi 15.0 12.5 10.0 7.5 5.0 2.5 1.5 50 75 100 250 500 750 1,000 2,500 20,00015,00010,0005,000 7,500 m3/h bar 11/2”21/2” 2” 50 80 3” 100 4” 150 6” 200 8” 250 10” 300 12” 350 14” 400 16” Flow Chart Flow Properties DN 40-50 65 80 100 150 200 250 300 350 400 Inch 1½"-2”2½"3"4"6"8"10"12"14"16"“Y”-TypeKv-Y 50 55 115 200 460 815 1,250 1,850 1,990 3,310 Cv-Y 58 64 133 230 530 940 1,440 2,140 2,300 3,820 K-Y 3.9 9.2 4.9 3.9 3.7 3.8 3.9 3.7 5.9 3.7 Leq-m, Y 10.3 33.4 21.6 23 37.5 53.9 70 85.6 159.9 112.7 Leq-feet, Y 33.8 109.5 70.8 75.6 123 176.9 229.5 280.8 524.5 369.6 AngleKv-A 55 61 127 220 506 897 1,375 2,035 2,189 3,641 Cv-A 64 70 146 250 580 1,040 1,590 2,350 2,530 4,210 K-A 3.2 7.6 4.0 3.2 3.1 3.1 3.2 3.1 4.9 3.0 Leq-m, A 8.5 27.6 17.8 19.0 37.0 44.6 57.8 70.7 132.1 93.1 Leq-feet, A 28 90.5 58.5 62.5 101.6 146.2 189.7 232 433.4 305.5 Valve flow coefficient, Kv or Cv Equivalent Pipe Length, Leq Flow resistance or Head loss coefficient, Cv = 1.155 Kv Where:Kv = Valve flow coefficient (flow in m3/h at 1bar Diff. Press.)Cv = Valve flow coefficient (flow in gpm at 1psi Diff. Press.)Q = Flow rate (m3/h ; gpm) ∆P = Differential pressure (bar ; psi) Gf = Liquid specific gravity (Water = 1.0) Kv(Cv)=Q Gf ∆P Leq=Lk.D K=∆H 2g V2Where:K = Flow resistance or Head loss coefficient (dimensionless) ∆H = Head loss (m ; feet)V = Nominal size flow velocity (m/sec ; feet/sec.)g = Acceleration of gravity (9.81 m/sec2 ; 32.18 feet/sec2) Where:Leq = Equivalent nominal pipe length (m ; feet)Lk = Equivalent length coefficient for turbulent flow in clean commercial steel pipe (SCH 40)D = Nominal pipe diameter (m; feet) Note: The Leq values given are for general consideration only. Actual Leq may vary somewhat with each of the valve sizes. 3 BERMAD Fire Protection 700 SeriesFP 700E Dimensions & Weights Size DN mm (inch)40 (1½”)50 (2”)65 (2½”)80 (3”)100 (4”)150 (6”)200 (8”)250 (10”)300 (12”)350 (14”)400 (16”)ANSI #150, ISO PN 16L (mm)10 205 222 250 320 415 500 605 725 733 990 LG(4)(mm)---250 320 415 500 ---- W (mm) 165 165 178 200 223 320 390 480 550 550 740 R (mm) 78 83 95 100 115 143 172 204 242 268 300 La (mm) 124 124 149 152 190 225 265 320 396 400 450 ha (mm) 85 85 109 102 127 152 203 219 273 279 369 Hy (mm) 239 244 257 305 366 492 584 724 840 866 1,108 Ha (mm) 227 227 241 281 342 441 545 633 777 781 1,082 Weight Y (kg) 10.6 10.6 13 22 37 75 125 217 370 381 846 Weight A (kg) 10 10 12 21.5 35 71 118 205 350 370 800 ANSI #300, ISO PN 25L (mm)210 210 222 264 335 433 524 637 762 767 1,024 W (mm) 165 165 185 207 250 320 390 480 550 570 740 R (mm) 78 83 95 105 127 159 191 223 261 295 325 La (mm) 124 124 149 159 200 234 277 336 415 419 467 ha (mm) 85 85 109 109 127 165 216 236 294 299 386 Hy (mm) 239 244 257 314 378 508 602 742 859 893 1,133 Ha (mm) 227 227 251 287 650 454 558 649 796 801 1,099 Weight Y (kg) 12.2 12.2 15 25 43 85 146 245 410 434 900 Weight A (kg) 11.5 11.5 13.5 23 41 81 138 233 390 421 855 Portsa (1) (mm)½½½½½½½½½½½ b (1) (mm) ½½½½½½½½½½½ c (1) (mm) ¾¾¾¾¾2 2 2 2 2 2 d (2) (optional)(mm) ¾¾1½1½2 2 2 2 2 2 2 Control Vol. (3)(Liter) 0.125 0.125 0.125 0.3 0.45 2.15 4.5 8.5 12.4 12.4 29.9 MetricSi Flanged d L & LG R Hy a cb a La Ha a ha cb a b c W b c Y Body Type Angle Body Type (1) (a), (b), (c) are NPT thread ports (2) (d) is BSPT threaded Optional drain port (3) (Control Volume) is Control Chamber Displacement Volume of liquid pushed when valve opens (4) LG for Grooved ends (see available sizes) 4 BERMAD Fire Protection 700 SeriesFP 700E Dimensions & Weights Size (inch)1½”2”2½”3”4”6”8”10”12”14”16”ANSI #150, ISO PN 16L (inch)8.1 8.1 8.3 9.8 12.6 16.3 19.7 23.8 28.5 28.9 39.0 LG(4)(inch)---9.8 12.6 16.3 19.7 ---- W (inch) 6.1 6.1 7.0 7.9 8.8 12.6 15.4 18.9 21.7 21.7 29.1 R (inch) 3.1 3.3 3.7 3.9 4.5 5.6 6.8 8.0 9.5 10.6 11.8 La (inch) 4.9 4.9 5.9 6.0 7.5 8.9 10.4 12.6 15.6 15.7 17.7 ha (inch) 3.3 3.3 4.3 4 5 6 8 8.6 10.7 11 14.5 Hy (inch) 9.4 9.6 10.1 12 14.4 19.4 23 28.5 33.1 34.1 43.6 Ha (inch)8.9 8.9 9.9 11.1 13.5 17.4 21.5 24.9 30.6 30.7 42.6 Weight Y (Lbs.)23 23 29 49 82 165 276 478 816 840 1,865 Weight A (Lbs.) 22 22 27 47 77 157 260 452 772 216 1,764 ANSI #300, ISO PN 25L (inch)8.3 8.3 8.7 10.4 13.2 17 20.6 25.1 30 30.2 40.3 W (inch) 6.5 6.5 7.3 8.1 9.8 12.6 15.4 18.9 21.7 22.4 29.1 R (inch) 3.1 3.3 3.7 4.1 5 6.3 7.5 8.8 10.3 11.6 12.8 La (inch) 4.9 4.9 5.9 6.3 7.9 9.2 10.9 13.2 16.3 16.5 18.4 ha (inch) 3.3 3.3 4.3 4.3 5.3 6.5 8.5 9.3 11.6 11.8 15.2 Hy (inch) 9.4 9.6 10.1 12.4 14.9 20 23.7 29.2 33.8 35.2 44.6 Ha (inch)8.9 8.9 9.9 11.3 13.8 17.9 22 25.6 31.3 31.5 43.3 Weight Y (Lbs.) 27 27 33 55 95 187 322 540 904 957 1,984 Weight A (Lbs.) 25 25 30 51 90 179 304 514 860 928 1,88 Portsa (1) (inch)½½½½½½½½½½½ b (1) (inch) ½½½½½½½½½½½ c (1) (inch) ¾¾¾¾¾2 2 2 2 2 2 d (2) (optional)(inch) ¾¾1½1½2 2 2 2 2 2 2 Control Vol. (3)(Gal.) 0.04 0.04 0.04 0.08 0.12 0.57 1.19 2.25 3.28 3.28 7.88 EnglishUS Flanged d L & LG R Hy a cb a La Ha a ha cb a b c W b c Y Body Type Angle Body Type (1) (a), (b), (c) are NPT thread ports (2) (d) is BSPT threaded Optional drain port (3) (Control Volume) is Control Chamber Displacement Volume of liquid pushed when valve opens (4) LG for Grooved ends (see available sizes) 5 BERMAD Fire Protection 700 SeriesFP 700E Installation, Operation & Maintanence Electric Pneumatic Hydraulic Electric Pneumatic Hydraulic Valve Closed (Set Position) Line pressure applied to the upper control chamber of the valve creates a superior force that moves the valve to the closed position and provides drip tight sealing. Valve Open (Operating Conditions) Releasing the pressure from the upper control chamber to atmosphere or some other lower pressure zone causes the line pressure acting on the seal disc to move the valve to the open position. Proper operation of the 700E Deluge Valves depends upon their trim being installed in accordance with the appropriate trim configuration. Notes: ■ Wet pilot height should not exceed “Maximum Elevation Above Valve” (see data for specific model). ■ Any deviation in trim size or arrangement may adversely affect the proper operation of the deluge valve. ■ All the pilot system devices, must be UL Listed and compatible with the particular deluge system. Refer to current “UL Listed Fire Protection Equipment Directory”. Warning: The deluge valve and trim must be installed only in areas where they will not be subject to freezing temperatures. Installation Instructions 1. Allow enough room around the valve assembly for any adjustments and future maintenance. 2. Before the valve is installed, flush the pipeline to remove any dirt, scale, debris, etc. Not flushing the line may result in the valve’s becoming inoperable. 3. Install the valve in the pipeline so that the valve flow arrow appearing on the body casting is pointing in the desired direction. Ensure that the valve is positioned so that the actuator assembly can be easily removed for future maintenance. 4. Ensure that the Control Trim is mounted properly and all other components are positioned correctly as per illustration. 5. After installation in the main line, carefully inspect/ correct any damaged accessories, piping, tubing, or fittings. Ensure that there are no leaks. 6. Install the components comprising the Deluge Trim Package in their proper positions in compliance with all instructions, drawings, and technical specifications describing the BERMAD Deluge Valve, according to the relevant illustration. 7. All additional accessories, although not packed together with the BERMAD Deluge Valve, must be installed as shown in the relevant P&ID and other illustrations. Operation Principle of Operation The BERMAD 700E Deluge Valve (assembled with specific trim) is suitable for systems that include adequate detecting and piping systems with open nozzles. The deluge valve prevents water from entering system piping until required. The deluge valve is kept closed by pressure applied to the upper control chamber through a restricted priming line. In the SET position, the water pressure supplied through the priming line is trapped in the upper control chamber of the deluge valve by a check valve, and by the normally closed release device. The pressure trapped in the upper control chamber of the deluge valve presses the valve seal disk down, thereby sealing the valve and keeping the system piping dry. Under conditions of FIRE, when the pressure is released from the upper control chamber by the opening of the automatic releasing device or by manual release, the deluge valve opens and allows the inlet supply water to flow through the valve and into the system piping and alarm devices. Warning: Whenever the handle of the Manual Emergency Release is pulled, pressure is released from the upper control chamber, the deluge valve will open, and water will flow into system piping and alarm devices. Installation 6 BERMAD Fire Protection 700 SeriesFP 700E Installation, Operation & Maintanence Placing in Service/Resetting The deluge valve and the control trim shall be Placed in Service with accordance to the most recent IOM procedures for the specific model. After all relevant instructions are performed, slowly open the supply-isolating valve and check that no water flows into the system. The system is now operational and in stand-by mode. Maintenance Bermad Deluge Valves require no lubrication, no packing tightening, and require a minimum of maintenance. Removing the System from Service Warning: When taking a deluge system out of service, a fire patrol should be established in the system area. If automatic fire alarm signaling equipment is utilized, the proper authority should be notified that the system is being removed from service. The insuring body and owner’s representative should also be notified when the system is being taken out of service. Removal Instructions 1. Shut off the main supply-isolating valve. 2. Close the priming line valve to the deluge valve control chamber. 3. Open all drain valves. 4. Release the water pressure from the control chamber of the deluge valve by pulling the manual emergency release. 5. Place "Fire Protection System Out of Service" signs in the area protected by the system. Inspection and Testing 1. Warning:Do not turn off the water supply to make repairs without placing a roving fire patrol in the area covered by the system. The patrol should continue until the system is back in service. 2. Prior to turning off any valves or activating any alarms, notify local security guards and the central alarm station, if used, to avoid signaling a false alarm. 3. The deluge valve and the control trim shall be maintained with accordance to the most recent IOM procedures for the specific model. A periodic test schedule should be established also with accordance to the site conditions and owner regulations. 4. Take all additional measures as required by NFPA-25 “standard for the inspection, testing, and maintenance of water-based fire protection systems”. 5. The system should be checked weekly for “Normal Conditions”. 6. Clean the priming strainer prior to any resetting of the deluge valve. 7. The deluge valve must be activated at full flow at least annually. Take all necessary precautions to drain water and prevent damage in the area protected by the system. 8. After about five years of operation, replacement of diaphragm and other elastomers is recommended. Remove the actuator and disassemble it. Clean the seat area from sediments, clean the control tubing entry holes, and install a new diaphragm and other elastomers in place. Spare Parts 1. The Diaphragm and the Seals are the only spare parts needed for the main deluge valve, see attached “Valve Disassembly and Parts Breakdown” illustration. 2. It is not recommended to store spare rubber parts for long periods (rubber in improper storage conditions can harden and crack). 3. Contact your Bermad representative and order new rubber parts when required. 7 BERMAD Fire Protection 700 Series Bearing Assembly Shaft Diaphragm Washer O-Ring Diaphragm Spacer Disk Diaphragm Washer Nut Indicator Lock Nut Cover Disk Bolt Cover Plug (6” and up) O-Ring Eye Nut Bearing Screw Disk Separation Partition Bolt Stud Nut Locking Screw Seal Disk Assembly Seal Disk Wash. Screw Seal SealDisk O-Ring Spring Nut Actuator Assembly Screw Removable Seat Nut Y Body Type Angle Body Type FP 700E Parts Valve Disassembling Parts Breakdown bermadfire@bermad.com • www.bermad.com © Copyright 2007-2012 Bermad CS Ltd. All Rights Reserved. The information contained in this document is subject to change without notice. BERMAD shall not be liable for any errors contained herein. PT7PE04-DATA 09.2012 8