Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
hydro analysis.pdf
Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 2Report Description: Light Hazard • • • • • Route 1 • • • • • PfPe Pv BL 1.0550 25.60 9.40 0.132243 15'-10 2.620102 0'-0 25.60 5.8 19.482 4'-0 7 0'-0 22.101 19'-10 150 Sprinkler 2T(2'-0) PfPe Pv BL 1.2910 52.78 12.94 0.188712 13'-6 3.4947 0'-0 22.101 5'-0 103 0'-0 25.595 18'-6 150 T(3'-0), E(2'-0) PfPe Pv BL 1.2910 82.13 20.13 0.427530 2'-10 1.227 103 0'-0 29.34 5.8 25.595 6 0'-0 26.822 2'-10 150 Sprinkler PfPe Pv BL 1.2910 111.32 27.28 0.750387 26'-6 29.656 6 0'-0 26.822 13'-0 4 0'-0 56.479 39'-6 150 5E(2'-0), T(3'-0) PfPe Pv BL 4.2600 111.32 2.51 0.003385 32'-0 5.008 4 0'-0 56.479 13.874 5 -32'-0 75.361 32'-0 120 BFP(-4.900) Pf Pe Pv FR 4.2600 111.32 2.51 0.003385 2'-7 3.009 5 -32'-0 75.361 1.119 2 -34'-7 79.489 2'-7 120 PRV(-3.000) Pf Pe Pv UG 4.2600 111.32 2.51 0.003385 14'-2 0.075 2 -34'-7 79.489 7'-11 6.142 3 -48'-9 85.705 22'-1 120 LtE(7'-11) Pf Pe Pv UG 4.2200 111.32 2.55 0.002665 50'-0 0.133 3 -48'-9 85.705 1 -48'-9 85.838 50'-0 140 Water Supply 211.32 100.00 Hose Allowance At Source 1 • • • • • Route 2 • • • • • Pf Pe Pv BL 1.0550 27.18 9.98 0.147786 0'-11 0.133104 0'-0 27.18 5.8 21.968 7 0'-0 22.101 0'-11 150 Sprinkler • • • • • Route 3 • • • • • PfPe Pv BL 1.0550 29.19 10.71 0.168554 6'-11 1.498101 0'-0 29.19 5.8 25.324 2'-0 6 0'-0 26.822 8'-11 150 Sprinkler T(2'-0) 1.51 4.87 150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.8/21/2014 Page 6AutoSPRINK® VR10 v10.0.55.0 2:44:27PM Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 2Report Description: Light Hazard Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve ZCap © M.E.P.CAD, Inc.8/21/2014 Page 7AutoSPRINK® VR10 v10.0.55.0 2:44:27PM