Loading...
HomeMy WebLinkAboutF14-0055 data sheets.pdf The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Standard Spray Bulletin 014 Rev. LBulletin 014 Rev. L Model F1FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Upright Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Pendent Model F1FR56LL & F1FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhütung GmbH 5. *NSF Certified to NSF/ANSi Standard 61 Annex G 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56, F1FR56LL, Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall RecessedPendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. 2. Technical data: Models Discharge Coeffi cient Response Thread Size Max. Working Pressure Min. Working Pressure Temperature Rating Finish F1FR56 **F1FR56LL(1)K 5.6 Quick Response 1/2” NPT (R1/2) 175 PSI 7 PSI See “Temperature Ratings” Table. See “Finish Table” F1FR42 **F1FR42LL(1) F1FRXLH K 4.2 F1FR28 K 2.8 (1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Defl ector Load Screw *Pintle Cup Washer Bulb DZR Brass QM Brass **Low Lead Brass CDA Alloy 260, CDA Alloy 220 orCDA Alloy510 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 651 or CDA Alloy 693 Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape Glass Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. Model F1FR42, F1FRXLH Upright Pendent ConventionalUpright Model F1FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Nominal K Factor Sprinkler Approval Sprinkler Identifi cation Number (SIN) Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1)1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 2, 3, 4, 6 RA1425 (1)(2)(3)(4)RA1414(1)(2)(3)(4) 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1 RA1423 (1)(4)RA1413(4) 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) 1 RA1421 (1)(4)RA1411(4) Conventional-Install in Upright or Pendent Position 15mm (1)1/2” NPT (R1/2) 5.6 80 57mm 3, 4, 6 RA1475 (3) (1) cULus listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. (3) Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant 3. Model F1FR56LL & F1FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Nominal K Factor Sprinkler Approval Sprinkler Identifi cation Number (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1)1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 5 RA1415 7/16” (11mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1, 5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark Model F1FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifi ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler Identifi cation Numbers (SIN)US Metric ½” (15mm) ½” NPT (R1/2) 5.6 80 2.25” (57mm) 1, 2, 3 RA1485(2)(3)15mm ½” NPT (R1/2) 5.6 80 2.25” (57mm) 3 (1) (1) LPC Approval is for pendent position only. (2) cULus Listed corrosion resistant (Polyester coated) sprinkler. (3) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Sprinkler Type Defl ector to Ceiling Distance (Min. - Max.) Upright 4” (102mm) - 12” (305mm) Pendent 4” (102mm) - 12” (305mm) Vertical Sidewall Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 F1 or F2 Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model F1FR56, F1FR42, F1FRXLH & F1FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Size K Factor Sprinkler Height Sprinkler Identifi cation Number (SIN)US Metric 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1414 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1413 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model F1FR56LL & F1FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifi ce Thread Size K Factor Sprinkler Height Sprinkler Identifi cation Number (SIN)US Metric 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1415 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions 4.*DuPont Registered Trademark 5. Model F1FR56 Quick Response Horizontal Sidewall Sprinkler Defl ector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal Orifi ce Thread Size Nominal K Factor Sprinkler Height Approval Organizations and Type of Approval Sprinkler Identifi cation Numbers (SIN)US Metric Light Hazard Ordinary Hazard ½” (15mm) ½” NPT (R1/2) 5.6 80 2.63” (67mm) 1, 2 1 RA1435 (1)(2)(3) (1) cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) Polyester coated FM approved sprinkler. (3) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with F1, F2 or FP escutcheons for “Light Hazard” only. While FM limits use for the same hazard with the F2 escutcheon only. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifi ce “K” Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identifi cation Number(SIN)US Metric Sprinkler Cover ½” (15mm) 5.6 80 ½” NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 4 (1), 6 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1 RA1414 ½” (15mm) 5.6 80 ½” NPT F1FR 200°F/93°C 165°F/74°C 150°F/65°C Green 1 RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2” [12,7mm] adjustment. Model F1FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifi ce “K” Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identifi cation Number(SIN)US Metric Sprinkler Cover ½” (15mm) 5.6 80 ½” NPT F1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1, 5 RA1414 *DuPont Registered Trademark Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model F1 or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½” orifice, ½” NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the F1FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- gagement. A choice of two cover plate assemblies provide either 1/2” (13mm) or 5/8” (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 25/8” (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. 6. *DuPont Registered Trade Mark Figure 1 Figure 2 Temperature Ratings Classifi cation Sprinkler Temperature Max. Ambient Temp.Bulb Color °C °F Ordinary Ordinary Intermediate Intermediate High (1) 57 68 79 93 141 135 155 175 200 286 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Orange Red Yellow Green Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 – cULus permits use with F1, F2 or FP escutcheons for “light hazard” only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate (1) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6)White Painted Special Application Finishes Sprinkler Escutcheon Cover plate (1) Electroless Nickel PTFE(Teflon®)*(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass(3)Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6)Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. (7) cULus listed Corrosion Resistant Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. *DuPont Registered Trademark • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09 /14 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.