Loading...
HomeMy WebLinkAboutOTC14-0039 roof specifications color.pdf 1976-2014 THE ROOFING COMPANY 39 Your Mountain Roofing Experts YEARS OF 28 Ten Mie Drive I PO Box 29 I Granby,CO 80446 I vrnw theroofingco.cont j 97C-897-0104 EXCELLENCE THE ROOFING COMPANY Estimator: Filipp Eretnev P: 970-887-0104 F: 970-887-0106 E: Feretnevtu.�.theroofinoco.com Attn:Gerrad Brigham&Bryan/Jeanne Macsata Aspen Lane Duplex 2855 Aspen Lane,Vail CO 81657 VAIL 303-884-1860(Gerrad)970-445-7747(Bryan) gbrigham@eberls.com,bryanmacsata@comcast.net Proposal date:July 17,2014 BID PROPOSAL Section I-DaVinci Roofing: 1-Acquire permit from local authority. 2-Remove existing shake,built up low sloped roofing,clean up daily,and dispose of all debris.Boston vent will remain in place. 3-Install Grace Ice and Water Shield.Pricing includes 2-plies at ridge and transition as well as stripping in all flashing flanges.Price includes 24"wrap up roof to wall junctures at headwalls only.Install Vulca-sheild as a 2nd layer for Class"A"fire separation at all designated locations. 4-Install 24 GA factory painted steel flashings at eave,rake,and L style at roof to wall locations. Install new pipe boots and reinstall hotstacks.Install 16oz copper flashings only at sky lights and chimneys.Fabrication and installation to be done in accordance with industry standards. 5-Install DaVinci Multiwidth Shakes with 8 inch exposure at all designated locations.Includes all components. 6-Price includes Taxes,Insurance,and saftey protocol.Installation of DaVinci components to be done in accordance with industry standards. Cost $57,540.00 LOW SLOPED ROOF---Install Tamko"Awaplan"rubberized premium membrane with all components, including all flashings at low sloped roofing area.(Must be choosen with main option to complete full reroof) (Cost ADD $4,571.00 Install New 5/8 OSB at all roofing locations. 'Cost ADD $5,519.00 Install New 5/8 CDX at all roofing locations.CDX is a better and lighter product. ICost ADD $7,783.00 EXCLUSIONS:Unless Otherwise Specified Snow and Ice removal. Blocking,framing,or carpentry. Ventilation calculations. Snow retention. Gutters,downspouts,or heat cable. Siding removal and reinstalation at sidewalls.All DaVinci Components.Rake,Starter,Ridge,shakes. Winter Conditions:(November through March)priming of roof decks will be billed at$.35 per sq.ft.in addition to contract.Snow Removal at$50.00 per man hour. The Roofing Company-2 Year Water-Tight Warranty(NOT PROVIDED WITH OWNER SUPPLIED MATERIAL) Water-Tight Guarantee-The Roofing Company will warranty all workmanship against leaks for a period of(2)years. Please Note-steep roofing systems are not designed to protect against standing water. Any condition causing standing water on roof (ie.ice damming)would void the water-tight guarantee. Initial to //++��� Accept lb L "I 1 1 IJ it VIVM skis NVOROTlC« Firestone BBB PREiEnfOtQN(RAM etRLI NNGBRiNIZOCTg sos rs YEAR SYSTEM WARRANTEs II YFAlI f6URANn Carlisle SynTec INTELLIGENT ROO°r,Gy MONS Please see"Conditions of Contract"Addendum to Proposal for Payment Terms&Conditions-Please note All amounts due and owing beyond thirty(30)days from completion,as set forth herein,shall bear interest at rate of one and one-half percent(1%%)per month Note:TRC expects ventilation to be calculated and appropriate for proper air flow and does not accept any responsibility for ventilation,condensation,or damage caused thereof. By receipt of this proposal,proposal addressee acknowledges that The Roofing Company(LRC)has amassed significant time in assembling and reviewing documents (drawings,pictures,etc.),coordinating information,applying methodologies,calculating interpreted costs,and building the appropriate proposal to relate this disclosure.Client and TRC agree that this information as supplied in the proposal contains confidential details and trade secrets owned by TRC and thus the client agrees to keep this information and trade secrets confidential.Any disputes or damages recognized through non-compliance with this matter shall be governed by THE ROOFING COMPANY Your Mountain Roofing Experts INFORMATION REQUIRED FOR BILLING/PAYMENT PURPOSES. PLEASE PRINT Contractor if applicable Job Name (Physical Address) 2 855 4s e t VQci I CO/ V j 7 Job Location I Contact Name 13r a A4 (5cL4t /Oe rre 13113110-, (Person responsible for payn3asnts due) Mailing Address Billing Address if different Telephone Ci-t) `97O -Gym 42- ( d) 970 -1/14,5 -77447 Fax 970 -- — Z-SESY Email byl,r)nni ziJ qya I100.COM br(�a.n lY1Q.CS 0 eitniCQ54i Credit Card Info if using for payment �/ Type of card Card Number Expiration Date Signature authorizing payment by card date Special Billing instructions or request • According to the contract terms (unless otherwise agreed upon between parties in writing) a 50% down payment is required before we can schedule work with the balance due upon completion. Payments in the form of a personal check are acceptable, or you may call our office at (970) 887-0104 to make arrangements for payment by Visa or MasterCard. The Roofing Company P.O. BOX 29, 29 TEN MILE DRIVE GRANBY, COLORADO 80446 970-887-0104 office-970-887-0106 fax = PAC-CLA1u►. Petersen Aluminum A Cardinal Red ♦ Colonial Red Burgundy A Terra Cotta A Sierra Tan A Mansard Brow' Apt Stone White A Granite A Sandstone A Almond ♦ Medium Bronze A Dark Bronze A*Slate Gray A Bone White A Musket Gray A; Charcoal Midnight Bronze Matte Black A*Cityscape Interstate Blue A Hemlock Green A Arcadia Green A Patina Green ♦Hunter Green .11J A*Military Blue Award Blue ♦Teal Hartford Green Forest Green ♦ Evergreen •Denotes PAC-CLAD Metallic Colors Denotes Energy Stare Colors ♦ Denotes PAC-CLAD Cool Colors Kynar 5003'or Hylar 500O'pre-finished galvanized steel and aluminum for roofing, curtainwall and storefront applications. +. Berkshire Blue A Slate Blue PAC-CLAD Metallic Colors •A*Zinc •A*Silver •AN'r Copper Penny •A` Aged Copper •A. Champagne •A.• Weathered Zinc PETERSEN ALUMINUM CORPORATION HQ:1005 Tonne Road 9060 Junction Drive 10551 PAC Road 350 73rd Ave.,NE,Ste 1 102 Northpoint Pkwy Ext, Bldg 1,Ste 100 Elk Grove Village,IL 60007 Annapolis Junction,MD 20701 Tyler,TX 75707 Fridley,MN 55432 Acworth,GA 30102 P:800-PAC-CLAD P:800-344-1400 P:800-441-8661 P:877-571-2025 P:800-272-4482 F:800-722-7150 F:301-953-7627 F:903-581-8592 F:866-901-2935 F:770-420-2533 PAC - CLAD' CALOR AVAILABIL Y PAC-CLAD 3 YEAR STEEL ALUMINUM ENERGY COLORS STANDARD REFLECTIVITY EMISSIVITY EXPOSURE SRI 24GA. 22GA. .032 .040 .050 .063 STAR Almond 0.56 0.83 0.57 64 4 J 4 4 4 • Arcadia Green 0.33 0.84 0.32 33 J 4 • Bone White 0.71 0.85 0.71 86 J 4 4 J J 4 • Cardinal Red 0.42 0.84 0.41 45 J J J Charcoal 0.28 0.84 0.28 27 4 J J E Cityscape 0.37 0.85 0.34 39 J J J 4 Colonial Red 0.34 0.85 0.33 35 4 J J 4 ° Dark Bronze 0.27 0.85 0.26 26 J J 4 J J J Evergreen 0.27 0.85 0.25 26 J 4 z Granite' 0.36 0.84 0.35 37 4 J 4 4 J ° Hemlock Green 0.30 0.85 0.31 30 J J 4 J • Hunter Green 0.26 0.84 0.26 24 J J Mansard Brown 0.26 0.84 0.24 24 J J J J J • Medium Bronze 0.30 0.85 0.29 30 J J J 4 4 4 ° Military Blue 0.29 0.84 0.28 28 J J Musket Gray 0.32 0.84 0.31 32 J J J J Patina Green 0.34 0.85 0.33 35 J J Sandstone 0.51 0.83 0.51 57 J 4 J 4 4 J Sierra Tan 0.38 0.85 0.35 40 J J J J 4 .. Slate Blue 0.25 0.84 0.27 23 J J Slate Gray 0.38 0.84 0.37 40 J J 4 4 4 .. Stone White 0.61 0.86 0.59 72 J J 4 4 J J Teal 0.26 0.85 0.26 24 J J Terra Cotta 0.37 0.84 0.37 39 4 J 4 • 4 PAC-CLAD METALLIC COLORS Aged Copper 0.27 0.83 0.25 25 4 4 4 Champagne 0.45 0.78 0.41 57 J 4 4 J • Copper Penny 0.45 0.82 0.42 49 J J J J Silver 0.53 0.80 0.51 59 J J J J Weathered Zinc 0.27 0.80 0.27 23 J J J " Zinc 0.30 0.85 0.30 30 J J J Galvalume Plus" 0.68 0.14 0.55 57 J PAC-CLAD STANDARD COLORS(DO NOT MEET COOL ROOF REQUIREMENTS) Award Blue J J J Berkshire Blue* 0.25 0.84 0.22 23 J • Burgundy J J J Forest Green J J 4 J J Hartford Green J J J J Interstate Blue J 4 J Matte Black J J .1 J J Midnight Bronze J PAC-CLAD,Metallic finishes are available from stock at a moderate extra cost.PAC-CLAD Copper Penny is a Non-Weathering finish. Solar Reflectance Index calculated according to ASTM C-1549. `Low Gloss/Low Sheen,full Kynar 500'1 or Hylar 500ff finish"Acrylic coated,non-Kynar Finish. Energystare Performance Criteria:Emissivity uses •Solvent Resistance:(NCCA procedure 11-18,no •Pencil hardness:(ASTM D 3363)-HB to 2H. ASTM C1371.Reflectivity uses ASTM C1549. comparable ASTM test)-Pass. •Specular Gloss(ASTM D 523)-At 60 degrees;Typical; Samples:These color reproductions are as accurate as •Humidity Resistance:(ASTM D 2247,Apparatus Al)-2,000 20-35(low gloss/tow sheen available). modem printing technology will permit.Free material samples hours,hot dipped Galvanized,or 3000 hours, •Abrasion Resistance:(ASTM D 968)-65x10 liters. are available on request. Aluminum: No field blisters. •Adhesion:(ASTM D 3359)-No loss of adhesion. Technical Data for Kynar 500./Hylar 5000'Coating: •Salt Spray Resistance:(ASTM B 117),3,000 hours, •Impact Resistance:(ASTM D 2794)-1/2"ball indenter, •Life Expectancy:20 years exposure:Chalk-rating of 8 or aluminum-No creep from scribe;no blisters.1000 hours, Gardner Impact tester:No cracking;no loss of adhesion. better.Color-<5AE(Hunter Units)change. hot dipped galvanized-creep from scribe not to exceed •Flame Test(ASTM E 84)-Class A coating •Accelerated Weathering:(ASTM G-23 Type EH Apparatus) 1/16";no blisters. Recycled Content:For information on recycled content, 5,000 hours:Chalk-rating of 8 or better.Color:s2AE •Chemical/Acid Pollution Resistance:(ASTM D 1308)-Pass. contact your PAC representative or visit (Hunter Units)color change. •Formability:(ASTM D 4145)-IT-3T,No loss of adhesion. www.pacgreeninlo.com PAC-CLAD'is a registered trademark of Petersen Aluminum Corporation,Kynar 500°is a registered trademark of Elf Atochem North America,Inc.Hylar 5000•is a registered trademark of Ausimont USA. 6/2010 r) . ....,_ .,,.. 'mss .,_ , ri,",:, M-2,----41' 4 DAVINCI SHAKE. .. :. . -#- _ 0 DaVinci Multi-Width Shake recalls the �,,vikvatakiiiaitim ., craftsmanship and authenticity of natural, hand- ii �' �� ;,,. split cedar shakes, with durability and a 50-year - `- .„ warranty.The deep-grained, multi-width tiles ' `"s are available in six standard color blends. iii ��, ;-,071.7.»...; �,�__.-..,.'� .."____,...i._______IJti f r i 1 ---r ____i .....____, . .. I iw J { ' tit ._._,,.,u: Chesapeake Mountain � I ' -5.fr 111117 I 4... . eaal I Ill , i iI O New Cedar tahoe Weathered Gray Contact a DaVinci project specialist to learn more about how you can create your own color blend or custom color. www.davinciroofscapes.com NOTE:Printing reproduction o colors shown in this brochure may vary from actual product. Low Maintenance & Easy Installation DaVinci Multi-Width Shake polymer roofing tiles make installation easy—saving materials and cutting down on installation costs.With little to no upkeep and backed by DaVinci's 50-year warranty, DaVinci shake tiles are the perfect fit for your home for generations to come. A Safer & More Secure Roof DaVinci Multi-Width Shake has achieved the highest possible test ratings for fire, wind and impact giving you a more secure home for your family and has been approved and preferred by cities and subdivisions nationwide. DAVINCI MULTI-WIDTH SHAKE SPECIFICATION CHART Shingle Dimensions Widths 9",8',7',6',4" Thickness at Butt 5/8" Length 22" Thickness at Tip 1/4" HIP* RIDGE•STARTER 6" Hip&Ridge One-piece Hip&Ridge 12'Valley Shingle 12"Starter Pieces/ Bundle 20 10 10 20 Lineal Ft/Bundle 8,33' 8,33' 4.3" 20 Pieces/Lineal Ft 2.40• 2,40' 2.3* 1 •At recommended 7"exposure FIELD SHINGLES PER ROOFING SQUARE Coursing Roof Pitch Max.Exposure Bundles/Square Shingles/Square Weight I Square Straight 4:12 or greater 10" 8 200 304 lbs Staggered 4:12 or greater 9' 9 225 342 lbs Note 1:All calculations are based on using the recommended 3/B' gap between shingles. Note 2:Felt interlay is suggested on any pitch and required on pitches less than 6'in 12' PACKING AND SHIPPING INFORMATION #Shingles Weight Per Bundle* 25 38 lbs Per Pallet•• 1,200 1,824 lbs Per Truckload'•• 28,800 43,776 lbs All weights are approximate ••48 bundles per pallet 24 pallets per truckload TESTING SUMMARY Type of Test Standard Results Fire Test ASTM E 108 Class A Impact Test UL 2218 Class 4 Wind Test ASTM D 3161 Certified to 110MPH• Building Code Approvals:ICC-ES ESR 2119,Miami-Dade County,FL NOA No. 13-0107.01 and TDI 'Go to www.davinciroofscapes.com for the most up-to-date technical information. Toll Free: 800-328-4624 Phone: 913-599-0766 Fax:913-599-0065 MLMWSHcs-2/14 www.davinciroofscapes.com DA\ cI DaVinci shake Multi-Width Shake • Single-Width Shake NSTALLATION GUIDE DaVinci polymer shakes are carefully engineered to provide the authentic look of hand-split shakes with dramatically increased durability and resistance to fire and impact. Special care has been taken to make the product easy to install.By following these instructions, and using good installation practices,you will be assured a quality installation. NOTE TO INSTALLER / DaVinci Shake offers a 5/8"thick profile,yet remains lightweight, because ' ` the shakes have an engineered rib structure.When cutting shakes for valleys or at overhangs such as eaves and gable ends,the ribbed support structure on the underside of the shake needs to be hidden by standard metal flashings.In addition,DaVinci offers a 12"solid accessory tile that can be used in these areas and J :: :: ::::: :: :::::: :h1 ld t the d fl fng. tspecial 1. for accessories and installation at eaves(page 2), gable ends(page 4)and valleys(page 7). JOB SITE READY! DaVinci shake bundles are delivered to the construction site pre-collated with shingle widths and color variations in the ordered blend. This pre-planned distribution produces the right aesthetic effect every time. Collated bundles also simplify installation and save time by eliminating hand sorting on the job site. . tt�r1 l�{ l lti Multi-Width Shake Widths: 9",8", 7", 6",4" Length:22" Thickness at butt: 5/8" Single-Width Shake Widths:9" Length:22" Thickness at butt:5/8" This information is provided for the use of professional roofing contractors.This Installation Guide does not supersede local building codes which should always be followed.DaVinci Roofscapes®does not warranty or have any responsibility for installation of its products.The DaVinci Roofscapes Limited Fifty-Year Warranty outlines its warranty responsibilities for the roofing materials it manufactures. For questions about DaVinci Shake or its application,contact DaVinci Roofscapes®,LLC 913-599-0766 or 800-DaVinci(800-328-4624)or www.davinciroofscapes.com Please be sure to check DaVinci's website for updates.Installation Guide is subject to change without notice. MLIGSH-06/14 Pg.1 of 10 INSTALLATION Decking Distance from butt-line Felt Interlay to felt is equal to twice DECKING the shingle exposure Shingle DaVinci Shake must be installed on a smooth flat surface(plywood or OSB); exposure - minimum 15/32"APA approved plywood or 7/16"approved OSB. It is necessary' 4r it that all previous roofing materials be removed prior to installation of DaVinci Shake.Imperfections in the decking may transmit through to finished roof. DRIP-EDGE Metal flashing is required on gable ends and eaves.An overhanging drip edge is recommended on gable ends to help mask the rib structure on the underside.An overhanging drip edge may also be used on eaves although non-overhanging drip edge styles are acceptable options. ,, 1-•' �► - Style D or Self-Adhered SELF-ADHERED MEMBRANE Style F Drip Edge . Membrane (Severe Climate Underlayment in accordance with Chapter 15 of the UBC) can be used Starter Course In areas where the average daily temperature in January is 25°F or lower or where ice buildup is possible,DaVinci requires self-adhered membrane be installed: from the bottom edge extending two feet above the exterior wall line on all eaves.The self-adhered membrane is required in all valleys regardless of average daily temperatures or the possibility of ice buildup. UNDERLAYMENT AND INTERLAYMENT Method 1: Class A installation One layer of GAF VersaShielde Fire—Resistant Roof Deck Protection(ESR-2053)in addition to required self-adhered membrane. Method 2: Class A Installation One layer Fontana VulcaSeal G40 in addition to required self-adhered membrane(This system is not recognized by ICC-ES). Method 3: Class C Installation The entire roof must be covered with an approved underlayment in addition required self-adhered membrane. Pitches below 6:12—DaVinci Shake should be installed with 30 lb felt interlay.Felt interlay is installed by rolling out 18" wide rolls of 30 lb felt at the same exposure as the shakes.The felt should be applied over the top portion of the shakes and extend onto the plywood sheathing so that the bottom edge of the felt is positioned at a distance above the butt equal to twice the weather exposure. So for an exposure of 10",start the layer of felt 20" above the butt line of the course below.If a class A installation is required the felt interlay must be used in addition to the other required underlayments.An alternative to using felt interlay is to use two layers of approved underlayment with their laps offset.If class A is required one of these layers may be GAF VersaShield or Fontana VulcaSeal G40. Note 1:Underlayment and Asphalt Shingles are listed Class A components of a listed roof deck assembly by an Approved Agency.The third party program in which products are certified,carry a label,and are listed in the directory of an agency accredited by the International Accreditation Service,Inc.(IAS),or by an accredited body that is a partner with IAS in a mutual recognition arrangement,pertaining to certification bodies and their compliance with ISO/IEC Guide 65,General Requirements for Bodies Operating Product Certification Systems. These underlayment and asphalt shingle components are to meet Class A Classification when tested to ASTM E108 or UL 790. Note 2:Underlayment and Asphalt Shingle components are to be installed with mechanical fasteners in accordance with the manufacturer's pub- lished installation instructions.Self-adhering or adhesive applied underlayment and asphalt shingle installtions are outside the scope of this listing. FASTENERS Tiles should be installed with nails long enough that they will penetrate through the roof deck by at least 3/16". In most instances, 13/4"roofing nails are acceptable. We recommend copper,stainless steel,or hot-dipped galvanized nails. Ring-shank nails should be used in high wind areas. STARTER COURSE Each starter tile should be installed so that it extends past the drip edge by approximately 1".If using overhanging drip edge,the starter shingle may overhang less if it is appropriate for the gutter system.The starter tiles should be installed with the DaVinci logo on top. The starter tiles should be spaced 3/8"apart as tiles will expand when warm.Each starter tile should be nailed with two approved nails on a line approximately 6" from the butt and 3/4" from outside edge. MLIGSH-06/14 c,Pg.2 of 10 INSTALLATION GETTING STARTED Use approved nails in each shake at or near nailing location shown on the shakes(see page 10).Nails may be placed lower than the indicators as long as the tile above it covers the nail.Once the starter tiles are in place,begin installing shakes in the lower left corner(or lower right corner for a left-handed roofer).The shakes should be flush with the starter tiles on the outer(rakes) and lower(eaves)edges.DaVinci recommends a minimum 3/8"gap between shakes. Two methods of installation are available: 1.Straight: in which the exposure of each shake is kept consistent 2. Staggered: in which the exposure varies by a maximum of 1"on adjacent shakes Use the alignment indicator at the top of each shake to help manage the exposure.An exposure of between 9"or 10" is acceptable for straight courses and 9" for staggered courses.As you progress up the roof,be careful not to damage shakes a ready in place.Put something,perhaps a piece of cardboard or cut shake, under toe irons(scaffolding brackets)to avoid scratching or marring the shake already installed below. STRAIGHT COURSING Install the shakes one at a time starting in the lower left hand Straight Coursing on DaVinci Shake at a 10"Exposure corner if right handed or lower right hand corner if left handed.The first course of shakes should be laid directly on 42" the starter tiles with the butt of the shake flush with the butt Nail of the starter tile.The shakes should be installed individually • • •/holes\• • • • with two nails in or near the defined areas.The shakes should 32" be laid individually with a rack type system,also known as rack-style,stair-stepping,or pyramiding;to prevent same size shake directly on top of another.The shakes should be laid with an approximate 3/8"gap between each shake.The gaps — — — — — — — — — —22" between shakes on adjacent courses should offset by a minimum 1%2".To assure proper horizontal alignment we recommend that chalk lines be snapped frequently.These chalk lines should be placed on the underlayments so that the shakes are aligned by the tips of the tiles rather than the butts. It Chalk lines should be snapped on underlayment with the tips of 3/8"Gap between each shingle the shakes following the lines.Do not snap lines on DaVinci Shake or use red chalk as the chalk may permanently discolor the shake. Staggered Coursing on DaVinci Shake at a 9" Exposure STAGGERED COURSING Staggering the courses is accomplished by laying the shakes — 40„ Nail in 9" courses with every other shingle lowered 1". holes An example of how to accomplish this is as follows: • ' �• Step 1: Lay the first course of shakes flush on top of the starter.Then snap a horizontal line 9"above the tips of the shakes you just installed or 31"from the eave line(butt of • the shake you just laid). —22" Step 2: The first shake on second course should be 9" installed putting the tip of the shake on the chalk line.The next or adjacent shake should be 1" below the line.The • third shake should be on the line;the fourth shake should 9„ be below the line.This continues in the same pattern all \ the wayacross the roof one shingle tipon the line and between Gap g each the next 1" below the line. shingle Pg.3 of 10 MLIGSH-06/14 INSTALLATION STRAIGHT COURSING (Continued) ,-: _:-• , .Atot Step 3: Snap another horizontal line 9"above the line you chalkedll in Step 2 or 40"above the butt of the first course of shakes.Start laying :I �,� shakes as in Step 2 with the first shake tip on the line and the next % shake tip about 1"below the line. �,4'-_,,,411r / it f Step 4: Continue up the roof in this manner.Every course does not i- '/(/ 00 need to be chalked.As roofers begin to understand the concept,they may use alignment indicators to accomplish the stagger.However,we do recommend frequent horizontal chalking to assure correct alignment. Chalk lines should be snapped on underlayment with the tips of the shakes following the lines.Do not snap lines on DaYinci Shake or use Field Shakes should extend red chalk as the chalk may permanently discolor the shake. '/<"past the overhang drip Single-Width 9" Shake Installation Tip:4 'h"or 5"setback pattern edge on gable ends(rakes). Method 1:A 5"setback pattern is recommended.In this method, starting from the bottom course,each 9"shake is set back 5"from GABLE ENDS/RAKES the shake on the adjacent course.This pattern is most easily established by using a roofing hammer with gauge set at 5':Once the pattern has Cutting DaVinci Shakes at gable ends,or where a course been established the setback should be checked occasionally. terminates can almost always be avoided by choosing from the Method 2:A 4'/"pattern may also be used.In this method,starting five different shake sizes and adjusting the spacing between from the bottom course,each 9"shake is set back 4'/i'from the shake shakes. In the rare case when cutting is required, shakes should on the adjacent course.This method requires that the pattern be straight be cut so that the factory edge faces out on the gable end. vertically as well as horizontally because the breaks between shakes on alternate course are aligned.With this method we recommend frequent Single-Width Shake Installation Tip vertical chalk lines so that the pattern may be checked regularly. The shakes are all 9"wide so must be cut at gable ends and any abutments.The 9" shakes should be cut so that the factory edge is GAP on the outside. The recommended gap between shakes is 3/8"with a minimum 3/16"gap required.The number of shingles per square for DaVinci CUTTING Shake is based on the assumption of 3/8"spacing between shakes. DaVinci Slate may be cut with a utility knife and straight edge. If spacing is less,more shingles per square will be required. It may also be cut effectively with a circular saw. Carbide tooth AVOID "CRACK ON CRACK" blades are recommended for maximum blade life. The gap between two shingles in one course should always line up 1'/"or more from the gap between two shingles in the course below. -` - ,f r 4F Correct , r Y F COLOR AND WIDTH VARIATION Incorrect DaVinci multi-width field shakes come in five widths: 9",8'; 7',6" and 4". Each bundle contains a mixture of 25 l shakes and includes a pre-collated assortment of widths and �____-�__ colors needed for each color blend. Single-Width Valore shakes ` • come in a single 9"width with 20 shakes per bundle. DaVinci il , Roofscapes recommends that the shakes should generally be l' ._--- �...� installed as they come out of the bundles.Keep in mind there `��� must be 1'/" side lap maintained and installation must be in a riii! iiii,iir i iit ill • rack or pyramid style. MLIGSH-06/14g1Q INSTALLATION ONE-PIECE HIP AND RIDGE APPLICATION:•HIP AND RIDGE PREPARATION DaVinci one-piece hip and ridge shakes have an optimum appearance when used on pitches of 12:12 or less. Steeper pitches may cause outside edge to lift and it is recommended the conventional two-piece hip and ridge method be used for pitches greater than 12:12.Roofing nails that penetrate through the roof deck and exceed it by 3/16" should be used. RIDGE VENT APPLICATION If using a continuous ridge vent we recommend a rigid shingle roll-over type. Once the continuous vent is installed, prepackaged 12"DaVinci One-Piece Hip and Ridge shingles should be installed in accordance with the standard hip and ridge installation instructions below. Special caution should be used when cutting the decking on the ridge to assure adequate nailing for the ridge pieces. DAVINCI ONE-PIECE HIP AND RIDGE SHINGLE INSTALLATION • DaVinci Shake one-piece hip and ridge should be installed at a 10"exposure with two roofing nails in each piece. • A pair of 6" shakes should be used as a starter course underneath the first piece of hip and ridge.These 6"tiles should be cut so that they are approximately 5"widths and they should also be cut in length so that they don't extend beyond the top of the second course of field tiles.If preferred on the bottom of a hip the two 6"DaVinci Shakes may be placed upside down so that the rib structure on the underside is not visible. • When installing the hip and ridge attempt to nail in areas where the underneath shakes offer support.It is not necessary to nail precisely in the nailing circles.This is especially important on hips.Roofing nails that penetrate through the roof deck by 3/16" should be used. _r qY -# k 1_ \\, -4NN-,.. ..., i I , ..-- ,</iN.'..s'N'-.. : i )„,.--- , < i),...,,,, N'N '..,, ,,.., . 1 ,7's4 I. a •. ,,,,. \ ...,..., i ..,,,.. NR./1 I ‘ . . • ., , L.,..:„:„.,._:,:.,,,, -'1'.. T.,...,...7.>"........,"' ',..;: :1/4....,.........../ . . ,,,,...s..1 .// 1 \ 0#7.-".. r>"'... 1 4111 12"DaVinci Shake 10"exposure �`'� f One-Piece Hip and Ridge } MLIGSH-06/14 Pg.5 of 10 INSTALLATION TWO-PIECE HIP AND RIDGE APPLICATION: HIP AND RIDGE PREPARATION After installing field shakes,hips and ridges should be prepared by installing a minimum 6"wide piece of non-corrosive metal,UV stable EPDM or equivalent over the hips and ridges. This metal or EPDM should extend at least three inches from the center point on each side of the hip or ridge. RIDGE VENT APPLICATION If using a continuous ridge vent we recommend a rigid shingle roll-over type.When installing continuous ridge vent,care should be taken to insure joints in ridge vent are water tight. Once the continuous vent is installed,prepackaged 6"DaVinci hip and ridge shakes should be installed in accordance with the standard hip and ridge installation instructions below. Caution should be used when cutting the decking on the ridge to assure adequate nailing for the ridge pieces.Roofing nails that penetrate through the roof deck and exceed it by 3/16"should be used. TWO-PIECE HIP AND RIDGE SHINGLE APPLICATION The bottom piece of hip and ridge should be cut so the tip does not extend past the butt of the second course.If preferred on the bottom of a hip,two 6"DaVinci Shake cut 5"wide placed upside down can be used as an under course.This will prevent the rib structure from being seen on the underside.These shakes that make up a hip and ridge unit should be installed with a ten-inch exposure.Using a chalk line to assure straightness,the prepackaged 6"hip and ridge should be installed one piece at a time so that the butts of two shingles are adjacent and the inside edges touch. Non-corrosive metal \, ks r i ./ , . j , / • . 1 ' ' \. \ e'''C • • 6 i N 1‘,/,: ,., s.. it', i s_ .„,.-\ , .1, F 7....,,,,,,.. ,..,, . of V=. ' �" t LW exposure - 6"DaVinci Shakes MLIGSH-06/14 C Pg.6 of 10 INSTALLATION VALLEYS Because DaVinci Shake has a rib-structure on the underside*,care must be used when installing DaVinci Shake in valleys. Open or closed valley systems may be used with variants of each system.Whether installing an open or a closed valley system, valley metal should be made from 24"stock of copper,minimum .019 aluminum,or minimum 28-gauge clad steel.DaVinci requires self-adhered membrane be used in all valleys. *A 12"solid shake accessory tile is available. OPEN VALLEYS If open valleys are preferred, be aware that the cut edge of the tile may be seen.Location of the valley,roof pitch and height of roof should be considered in determining if the cut tiles will have an acceptable appearance. Option A:In many cases,with steeper pitched roofs,it is acceptable to Option A install a"W"valley and cut the DaVinci Shake on an angle parallel and Single Diverter Valley Metal 2W'from the center diverter.Keep in mind that the cut rib structure of the 7" shakes may be visible from the ground with some roof pitches. DaVinci offers 12"solid tiles if the rib structure or open area under DaVinci iov_" shakes is a concern. Option B Option B: Double"W"valley.This should be made from 24" stock that Twin Diverter Valley Metal is broken in the middle without diverter to look like a"V': Additionally, there should be a"W"(diverter)on either side 2W'from the center line. / I'%" (See Diagram)DaVinci Shake should be cut and laid against the diverters on either side to mask the rib structure. to° Valley metal(Option A or B) Valley metal broken from 24"stock. The top corner of the shake closest to Self-adhered membrane is the center of the valley should be cut required in all valleys. off at a 45°angle. Use wider shakes adjacent to valley where possible. Nail as far from center as • practical.Try to not nail 'A 1 . / closer than 5"from center. Y I` ' • . / • \ . \ _ . 1 :p_,. -C1..''r r 7- --- 4. MLIGSH-06/14 O.P- of 0 INSTALLATION CLOSED VALLEYS A closed valley can be achieved by using valley metal option(A or B).In our preferred method,option A,valley metal with a single, narrow-based diverter in the middle is used and the DaVinci Shakes are cut and butted to the diverter.An alternate is to use standard"W"valley with the shakes butted against the diverter.Wider shakes should be used as valley cuts in order to ensure that nailing be kept at least 5"from center or as far from center as possible. Option A Option A: Install valley with a standing seam in the middle and Standing Seam Valley Metal place already-cut DaVinci Shake against center standing seam. i w \ lo%:"-11" Option B: It is acceptable to install a"W"valley and place an Option B all ready-cut DaVinci Shake against center diverter.Metal should be Single Diverter Valley Metal broken with a diverter at least 11/4"tall. 1 ya„ ta'i" Valley metal broken from 24"stock. Valley metal(Option A or B) The top corner of the shake closest to Self-adhered membrane is the center of the valley should be cut required in all valleys. off ata 45°angle. Use wider shakes adjacent to ' valley where possible. Nail as far from center as �' practical.Try to not nail rr` /° closer than 5"from center. MLIGSH-06/14 ( Pg.8 of 10 SPECIAL ISSUES FLASHING i . 4. y. fFold down Flashing should be used in all areas , ,. counter flashing where the roof abuts a vertical wall, '•- ,.,r....>r over step flashing. dormer,chimney,skylight or other s structural protrusions. Fasten flashing ry ' ,4___------ to roof. Use the step flashing method,with - . copper,a minimum of 28-gauge clad Succeeding steel,or a minimum .019 aluminum ,, flashing pieces flashing.The flashing should extend 14"long with 4"overlap. 4"upvertical walls. - - -- First piece of Counter i ! Flashing flashing is 14" Apron Flashing - � Mini Jr ,f mum Lengths VENTILATION7- l4' ../1 „.- In some climatic regions of the country,proper ventilation is crucial to the performance of a roofing i /- system.Proper ventilation is especially important in cold climates where modern houses are well 4•' insulated and weather-tight.We suggest you follow standard building practices in your area and meet all national and local building codes.A continuous ridge vent combined with proper intake or eave ventilation is an especially effective ventilation system,and one that we highly recommend. Continuous Vent SNOW GUARDS }.' ;, , _ One square foot of .,� __ vent for every 300 square feet of attic. Snow guards should be considered in all geographic _------2-7 17-- areas where accumulating snow fall is possible. V' •• _ A`— 1.Most kinds of brass,copper,or clad aluminum f snow guard systems work well with DaVinci. / 'J� r!, \. Rocky Mountain Snow Guards,Inc. is good source -_j r j,_ , for further information about snow guards.Contact • . • {A,. \ them at www.rockymountainsnowguards.com / .'/ r � C or call 877-414-7606.It is recommended that snow i ;, f ice- guards be installed during the installation of the " . :'_ y j, �� a r;y _ DaVinci roof although retro-fit snow guards are Z. /, � ` /f r available for previouslyinstalled DaVinci roofs. a /, Details regarding installation remain the _ - -- --I . a---- responsibility '�responsibility of the installer and the customer. --` _ 'rte Soffit Vents -----7---_ __; ' lir For additional information please see Q&A Guide to Snow Guards at www.davinciroofscapes.com/technical-downloads.php. Consult with your local contractor to determine if snow guards would be appropriate for your project. DaVinci makes no representations or warranties about the propriety of snow guard installation on any given project. Rather,the decision to install snow guards rests solely with the end user. Pg.9 of 10 MLIGSH-06/14 PRODUCT FEATURES EXPOSURE ROOF PITCH COURSING INTERLAY MAX.EXPOSURE Exp,:. Less than 3:12 Not Recommended Align less than 6:12 Staggered Required* 9" less than 6:12 Straight Required* 10" 6:12 or greater Staggered Recommended 9" 6:12 or greater Straight Recommended 10" I j Felt interlay is suggested on any pitch and required on pitches less than 6"in 12'.' I *If two layers of Fontana VulcaSeal is used interlay is not required. 5 . t l'. • ! ;�ura • ) . ,,i NAILING Each shake should be applied with two copper,non-corrosive stainless steel, or hot-dipped galvanized,3/8"head x 1'/4"length nails in most instances. Roofing nails that penetrate through the roof deck and exceed it by 3/16" should be used. Shakes can be nailed by hand or with a pneumatic nail gun. i Don't overdrive nails or drive nails at an angle.Keep the nail head flush with 1 i the surface of the shingle to avoid creating"craters"which can collect moisture 1 • i t4 1 : , and can also prevent the exposed end of the shingles from laying flat. ' ,I 1 ' i Use these alignment guides with the top edge of the previous row of shakes to control the exposure. • i CUTTING DaVinci Shake can be cut with a utility knife and straight edge. QUICK REFERENCE Electrical circular saws(carbide blade,two teeth per inch)or cordless circular saws(a minimum of 18 volts is recommended) • Don't overdrive or install nails at an angle may also be used. • Always leave a gap between all tiles Please note:DaVinci Shake is made flat,should be stored flat and • Vertical,always install up the roof not one row must not be installed unless it is flat and in its original form.If shakes across the roof at a time are not stored flat and become twisted or curled, lay them flat in a • Install over a clean plywood deck only warm place and they will return to their original flatness.Damaged • Never use red chalk shake should never be installed. • Cut edges always go to the inside along rake edges or gable ends ELECTRO-GALVINIZED NAILS • Install snowguards in any snow prone area DaVinci recommends the use of copper,stainless steel,or hot-dipped galvanized nails.We realize however that in many ISSUE DAVINCI ACCEPTABLE climatic regions nail corrosion is not a factor in the long-term RECOMMENDS ALTERNATIVES performance of the roof system.Therefore DaVinci Roofscapes Valley Copper 28-gauge clad metal supports the use of Electro-galvanized nails and a system using Flashing Copper 28-gauge clad metal those nails will be in compliance with the DaVinci Fifty-year Limited Warranty.The exception to that is that if the nails fail, Eaves Flashing Copper 28-gauge clad metal any portion of the warranty associated with wind performance Nails Non-Corrosive Hot-dipped would be void. Stainless Steel Galvanized For questions about DaVinci Shake or its application,contact DaVinci Roofscapese,LLC 913-599-0766 or 800-DaVinci(800-328-4624)or www.davinciroofscapes.com Please be sure to check DaVinci's website for updates.Installation Guide is subject to change without notice. MLIGSH-06/14 c` Pg.10 of 10