Loading...
HomeMy WebLinkAboutF14-0056 data sheets.pdf Fire Sprinkler Equipment Submittals For Vail Four Seasons Unit #1021 1 Vail Road Vail, CO 81657 Edward Kolecke NICET Level III # 94588 Worldwide Contacts www.tyco-fire.com Series RFII — 5.6 K-factor “Royal Flush II” Concealed Pendent SprinklersQuick & Standard Response, Standard Coverage Page 1 of 4 MARCH 2013 TFP181 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal-lation of sprinkler systems and com-ponents. Improper handling and in-stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur-ing a flat cover plate designed to con-ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar-eas such as hotel lobbies, office build-ings, churches, and restaurants. Each sprinkler includes a Cover Plate/Retainer Assembly and a Sprinkler/Support Cup Assembly. The separa-ble, two-piece assembly design pro-vides the following benefits: • Allows installation of the sprinklers and pressure testing of the fire pro-tection system prior to installation of a suspended ceiling or applica-tion of the finish coating to a fixed ceiling. • Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. • Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea-sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- stallation or finish. The tip of the Pro-tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push-ing the ceiling product against the Pro-tective Cap. When ceiling installation is complete, the Protective Cap is re-moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) “Royal Flush II” Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. NOTICE The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli-ance with this document and with the applicable standards of the National Fire Protection Association, in addi-tion to the standards of any authori-ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain-ing their fire protection system and de-vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 — 3 mm bulb TY3551 — 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri-teria section. • TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif-icate No. G4090007), and NYC Ap-proved (MEA 353-01-E) as Quick Response. • TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. • TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFP181 Page 2 of 4 Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . Bronze Support Cup. . . . . . . . . . . . . .Chrome Plated SteelGuide Pins .........Stainless SteelDeflector.................BronzeCompression Screw. . . . . . . . . Brass Bulb ......................GlassCap.............Bronze or CopperSealing Assembly. . . . . . . . .Beryllium Nickel w/ TEFLONCover Plate. . . . . . . . . . . . . . . . BrassRetainer . . . . . . . . . . . . . . . . . . BrassEjection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Sprinklers are intended for fire protec-tion systems designed in accordance with the standard installation rules rec-ognized by the applicable Listing or Approval agency; for example, UL List-ing is based on NFPA 13 and VdS Ap-proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro-tection Products at the following office: Enschede, NetherlandsTelephone: 31-53-428-4444Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. NOTICE Do not use the Series RFII in applica-tions where the air pressure above the ceiling is greater than that be-low. Down drafts through the Sprin-kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector — supported by the Guide Pins — then drops down to its operational position. The glass bulb contains a fluid that ex-pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. SPRINKLER/SUPPORT CUPASSEMBLY COVER PLATE/RETAINERASSEMBLY GUIDEPINS (2) DEFLECTOR (DROPPED POSITION) COMPRESSION SCREW DEFLECTOR SUPPORT CUP WITH ROLL FORMED THREADS FRAME 1/2" NPT CAP BULB SEALINGASSEMBLY RETAINER WITH THREAD DIMPLES EJECTION SPRING SOLDER TABS (3) COVER PLATE THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Installation The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Sprinklers must be installed in accor-dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin-kler held horizontally, a small air bub-ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min-imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In-let with consequent leakage or impair-ment of the sprinkler. Do not attempt to compensate for in-sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin-kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap-plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and TFP181 Page 3 of 4 COVER PLATEPROFILE DEPTHDIMENSION B 1/2" (12,7 mm) THREADED ADJUSTMENTD FACE OFSPRINKLERFITTING MANUFACTURER PRESET GAP 3/32" (2,4 mm) FACE OF CEILING, RETAINING RING MOUNTING SURFACE SPRINKLER SUPPORT CUP ASSEMBLY CLEARANCE HOLEDIAMETERDIMENSION C DEFLECTOR IN DROPPED POSITION 3/16" to 11/16" (4,8 to 17,5 mm) REFERENCE COVER PLATE RETAINER ASSEMBLY COVER PLATEDIAMETERDIMENSION A A: 3-1/4 inches (82,6 mm)C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) B: 3/16 inches (4,8 mm)D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS FRAME ARM SUPPORTCUP 7/8" (23 mm)SQUARE ACCEPTS1/2" SOCKETDRIVE ALIGNARROWS WITHFRAME ARMS FIGURE 3 RFII SPRINKLER WRENCH CLEARANCEHOLE FIGURE 4 DISPOSABLE PROTECTIVE CAP Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear-ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. NOTICE As long as the Protective Cap remains in place, the system is considered “Out of Service”. Step 6. After the ceiling has been com-pleted with the 2-1/2 inch (63,5 mm) di-ameter clearance hole and in prepa-ration for installing the Cover Plate/Retainer Assembly, remove and dis-card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac-cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As-sembly sufficiently to contact the ceil-ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 Care and Maintenance The TYCO Series RFII 5.6 K-fac-tor, “Royal Flush II” Concealed Pen-dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys-tem from the proper authorities and notify all personnel who may be affect-ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera-tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be-tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil-ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak-ing or exhibiting visible signs of corro-sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other-wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam-age to the sprinklers - before, during, and after installation. Sprinklers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be re-placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in-stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re-place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) SUPPORTCUP SPRINKLER AIR AND DUST SEALCOVER PLATE LIP OF RETAINER FACE OFCEILING ORIENTSEALBEVEL ASSHOWNCOVERPLATERETAINERASSEMBLY FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) If you must remove a sprinkler, do not reinstall it or a replacement without re-installing the Cover Plate/Retainer As-sembly. If a Cover Plate/Retainer As-sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in-spection, testing, and maintenance of their fire protection system and devic-es in compliance with this document, as well as with the applicable stan-dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori-ties having jurisdiction. Contact the in-stalling contractor or sprinkler manu-facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor-dance with local requirements and/or national code. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, “Royal Flush II” Pendent Sprin-klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C)200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be-low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) ....56-792-0-135 56-792-0-165 Brass ..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) ....56-792-3-135 56-792-3-165 Signal White (RAL9003) ....56-792-4-135 56-792-4-165 Jet Black (RAL9005) ....56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 (a) For use with 155°F (68°C) sprinklers. (b) For use with 200°F (93°C) sprinklers. (c) Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. Superior Coating Dyna-Thread – M-COAT products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products are coated with M-COAT, an advanced MIC coating that is FM approved for use American Made Able to meet “Buy American” requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread – M-COAT pipe is manufactured to meet ASTM A-135, Type E Grade A, is in compliance with NFPA-13 and all sizes are rated at 300 psi working pressure. Dyna-Thread – M-COAT is UL and cUL listed for wet, dry deluge and pre-action sprinkler systems and FM approved for use in wet systems. Dyna-Thread – M-COAT can be hot dip galvanized** to meet FM requirements for use in dry systems. Dyna-Thread – M-COAT is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved and plain end fittings. • Exceptional hydraulics • Lightweight and easy to install • Available factory roll grooved • M-COAT ID • UL and cUL listed • FM approved Combining the safety and longevity of Sch-40 with quality and hydraulic advantages. Dyna-Thread® – M-COAT® pipe is the full line Schedule 40 replacement with the same CRR of Schedule 40, 1.00, providing Dyna-Thread – M-COAT with the same life expectancy as Sch-40. With outstanding hydraulic capabilities, Dyna-Thread – M-COAT is a more widely accepted product substitution than lightwall threadable pipe when Sch-40 is specified. Dyna-Thread – M-COAT’s inside diameter is up to 3.6% larger than Sch-40 and provides improved hydraulics. When used in combination with Dyna-Flow pipe, down sizing of pipe and related components often occurs, thereby reducing costs. The consistent quality of steel used to make Dyna-Thread – M-COAT facilitates smooth threading and lower maintenance costs. Increased strength and lighter weight allows Dyna-Thread – M-COAT to reduce installation fatigue and makes it ideal for retro-fit applications. Dyna-Thread® – M-COAT ® Full Line Schedule 40 Replacement Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 ©2013 Atkore International, Inc. All Rights Reserved. STP-S3-3M-1301 Dyna-Thread – M-COAT NPS Nominal I.D.Wt.Wt. (H20 Filled)CRR CRR In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m Unthreaded Threaded 1”1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 –– 1¼”1.408 1.870 2.54 9.50 1.00 32 35.8 2.8 3.78 –– 1½”1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 4.79 –– 2”2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 –– ** Must be ordered in 10 bundle increments Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE SIZE (in) WEIGHT (lbs/ft) I.D. (in) BUNDLE SIZE 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS NOMINAL PIPE SIZE (in) SCHEDULE 40 EDDYTHREAD 40 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail:sales@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-000 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 90° elbow Nominal Size Anvil ItemNumber Universal Number Max. Working Pressure Dimensions- In.(mm)Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840000004 DB90033 500 1.50 1.50 0.6220345038.10 38.10 0.28 11⁄4 840000012 DB90044 500 1.75 1.75 0.90 32 3450 44.45 44.45 0.41 11⁄2 840000020 DB90055 500 1.94 1.94 1.20 40 3450 49.276 49.276 0.54 2 840000038 DB90066 500 2.25 2.25 1.85 50 3450 57.15 57.15 0.84 B A 90° elbow Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-002 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing 90° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 x 1⁄2 840001036 DB90031 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.201 x 3⁄4 840001044 DB90032 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 840001051 DB90041 500 1.34 1.53 0.6432 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 840001069 DB90042 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 840001077 DB90043 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 840001085 DB90053 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 840001093 DB90054 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.492 x 1⁄2 840001101 DB90061 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 840001119 DB90062 500 1.60 1.97 1.2450 x 20 3450 40.64 50.03 0.56 2 x 1 840001127 DB90063 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 840001135 DB90064 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 840001143 DB90065 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 A B reducing 90° elbow Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. 45° elbow Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions-Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840002133 DB45033 500 1.12 1.12 0.46 25 3450 28.44 28.44 0.2111⁄4 840002141 DB45044 500 1.29 1.29 0.73 32 3450 32.76 32.76 0.33 11⁄2 840002158 DB45055 500 1.43 1.43 0.9240345036.32 36.32 0.42 2 840002166 DB45066 500 1.68 1.68 1.50 50 3450 42.67 42.67 0.68 A B45° elbow Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-003 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. Straight tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B In. (mm)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840003164 DT333 500 1.50 1.50 0.85 25 3450 38.10 38.10 0.39 11⁄4 840003172 DT444 500 1.75 1.75 1.22 32 3450 44.45 44.45 0.55 11⁄2 840003180 DT555 500 1.94 1.94 1.55 40 3450 49.27 49.27 0.70 2 840003198 DT666 500 2.25 2.25 2.45 50 3450 57.15 57.15 1.11 B AA Straight tee Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-004 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 11⁄2 x 11⁄4 x 1 840004428 DT543 500 1.65 1.58 1.80 1.2540 x 32 x 25 3450 41.91 40.13 45.72 0.5711⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.9040 x 32 x 50 3450 54.86 53.34 51.30 0.8611⁄2 x 11⁄2 x 1⁄2 840004444 DT551 500 1.41 1.41 1.16 1.1540 x 40 x 15 3450 35.81 35.81 29.46 0.5211⁄2 x 11⁄2 x 3⁄4 840004451 DT552 500 1.52 1.52 1.75 1.2440 x 40 x 20 3450 38.61 38.61 44.45 0.5611⁄2 x 11⁄2 x 1 840004469 DT553 500 1.65 1.65 1.80 1.3040 x 40 x 25 3450 41.91 41.91 45.72 0.5911⁄2 x 11⁄2 x 11⁄4 840004477 DT554 500 1.82 1.82 1.88 1.4840 x 40 x 32 3450 46.23 46.23 47.75 0.6711⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.9840 x 40 x 50 3450 54.86 54.86 51.30 0.902 x 1 x 2 840004493 DT636 500 2.25 2.02 2.25 2.1550 x 25 x 50 3450 57.15 51.31 57.15 0.982 x 11⁄4 x 2 840004501 DT646 500 2.25 2.10 2.25 2.3050 x 32 x 50 3450 57.15 53.34 57.15 1.042 x 11⁄2 x 1⁄2 840004519 DT651 500 1.49 1.41 1.88 1.5050 x 40 x 15 3450 37.85 35.81 47.75 0.682 x 11⁄2 x 3⁄4 840004527 DT652 500 1.60 1.52 1.97 1.6250 x 40 x 20 3450 40.64 38.61 50.04 0.732 x 11⁄2 x 1 840004535 DT653 500 1.73 1.65 2.02 1.6450 x 40 x 25 3450 43.94 41.91 51.31 0.742 x 11⁄2 x 11⁄4 840004543 DT654 500 1.90 1.82 2.10 1.8050 x 40 x 32 3450 48.26 46.23 53.34 0.822 x 11⁄2 x 11⁄2 840004550 DT655 500 2.02 1.94 2.16 2.0050 x 40 x 40 3450 51.31 49.28 54.86 0.912 x 11⁄2 x 2 840004568 DT656 500 2.25 2.16 2.25 2.3550 x 40 x 50 3450 57.15 54.86 57.15 1.072 x 2 x 1⁄2 840004576 DT661 500 1.49 1.49 1.88 1.6050 x 50 x 15 3450 37.85 37.85 47.75 0.732 x 2 x 3⁄4 840004584 DT662 500 1.60 1.60 1.97 1.6850 x 50 x 20 3450 40.64 40.64 50.04 0.762 x 2 x 1 840004592 DT663 500 1.73 1.73 2.02 1.8550 x 50 x 25 3450 43.94 43.94 51.31 0.842 x 2 x 11⁄4 840004600 DT664 500 1.90 1.90 2.10 2.0450 x 50 x 32 3450 44.45 42.42 44.45 0.932 x 2 x 11⁄2 840004618 DT665 500 2.02 2.02 2.16 2.1850 x 50 x 40 3450 44.45 42.42 44.45 0.992 x 2 x 21⁄2 -DT667 500 2.60 2.60 2.39 3.6150 x 50 x 65 3450 44.45 42.42 44.45 1.6421⁄2 x 2 x 3⁄4 -DT762 500 1.74 1.60 2.32 2.2865 x 50 x 20 3450 44.45 42.42 44.45 1.03 reducing tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachABC In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs.(kg) 1 x 1⁄2 x 1 840004196 DT313 500 1.50 1.36 1.50 0.6425 x 15 x 25 3450 38.10 34.54 38.10 0.291 x 3⁄4 x 1 840004204 DT323 500 1.50 1.45 1.50 0.7325 x 20 x 25 3450 38.10 36.83 38.10 0.331 x 1 x 1⁄2 840004212 DT331 500 1.26 1.26 1.36 0.7125 x 25 x 15 3450 32.00 32.00 34.54 0.321 x 1 x 3⁄4 840004220 DT332 500 1.37 1.37 1.45 0.7625 x 25 x 20 3450 34.80 34.80 36.83 0.341 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.9825 x 25 x 32 3450 42.41 42.41 40.13 0.441 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.1625 x 25 x 40 3450 45.72 45.72 41.91 0.5311⁄4 x 1 x 1⁄2 840004253 DT431 500 1.34 1.26 1.53 0.8232 x 25 x 15 3450 34.04 32.00 38.86 0.3711⁄4 x 1 x 3⁄4 840004261 DT432 500 1.45 1.37 1.62 0.9032 x 25 x 20 3450 36.83 34.80 41.15 0.4111⁄4 x 1 x 1 840004279 DT433 500 1.58 1.50 1.67 1.0032 x 25 x 25 3450 40.13 38.10 42.42 0.4511⁄4 x 1 x 11⁄4 840004287 DT434 500 1.75 1.67 1.75 1.0832 x 25 x 32 3450 44.45 42.42 44.45 0.4911⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.4232 x 25 x 40 3450 47.75 45.72 46.22 0.6411⁄4 x 11⁄4 x 1⁄2 840004303 DT441 500 1.34 1.34 1.53 0.8632 x 32 x 15 3450 34.04 34.04 38.86 0.3911⁄4 x 11⁄4 x 3⁄4 840004311 DT442 500 1.45 1.45 1.62 0.9232 x 32 x 20 3450 36.83 36.83 41.15 0.4211⁄4 x 11⁄4 x 1 840004329 DT443 500 1.58 1.58 1.67 0.9532 x 32 x 25 3450 40.13 40.13 42.42 0.4311⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.4532 x 32 x 40 3450 47.75 47.75 46.22 0.6611⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.7532 x 32 x 50 3450 53.34 53.34 48.26 0.7911⁄2 x 1 x 1⁄2 840004352 DT531 500 1.41 1.34 1.66 0.9540 x 25 x 15 3450 35.81 34.04 42.16 0.4311⁄2 x 1 x 3⁄4 840004360 DT532 500 1.52 1.37 1.75 1.1440 x 25 x 20 3450 38.61 34.80 44.45 0.5211⁄2 x 1 x 1 840004378 DT533 500 1.65 1.50 1.80 1.1740 x 25 x 25 3450 41.91 38.10 45.72 0.5311⁄2 x 1 x 11⁄4 840004386 DT534 500 1.82 1.67 1.88 1.3440 x 25 x 32 3450 46.23 42.42 47.75 0.6111⁄2 x 1 x 11⁄2 840004394 DT535 500 1.94 1.80 1.94 1.4540 x 25 x 40 3450 49.28 45.72 49.28 0.6611⁄2 x11⁄4 x 1⁄2 840004402 DT541 500 1.41 1.34 1.66 1.0540 x 32 x 15 3450 35.81 34.04 42.16 0.4811⁄2 x11⁄4 x 3⁄4 840004410 DT542 500 1.52 1.45 1.75 1.1540 x 32 x 20 3450 38.61 36.83 44.45 0.52 C BA reducing tee Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-005 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. bull head tee Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. Each A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 1 x 1 x 11⁄4 840004238 DT334 500 1.67 1.67 1.58 0.9825 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2 840004246 DT335 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 11⁄2 840004295 DT435 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 11⁄2 840004337 DT445 500 1.88 1.88 1.82 1.45 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 11⁄4 x 11⁄4 x 2 840004345 DT446 500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.7911⁄2 x 11⁄4 x 2 840004436 DT546 500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 2 840004485 DT556 500 2.16 2.16 2.02 1.9840 x 40 x 50 3450 54.86 54.86 51.30 0.90 C BA bull head tee Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-006 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. croSS Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions Approx. Wt. EachAB In. (mm)In. (mm)PSI (kPa)PSI (kPa)In. (mm)In. (mm)Lbs. (kg) 1 840006647 DX033 500 1.50 1.50 0.98 25 3450 38.10 38.10 0.4411⁄4 840006654 DX044 500 1.75 1.75 1.50 32 3450 44.45 44.45 0.68 11⁄2 840006662 DX055 500 1.94 1.94 1.9040345049.27 49.27 0.86 2 840006670 DX066 500 2.25 2.25 2.95 50 3450 57.15 57.15 1.34 11⁄4 x 1 840007678 DX043 500 1.58 1.67 1.27 32 x 25 3450 40.13 42.41 0.58 11⁄2 x 1 840007686 DX053 500 1.65 1.80 1.48 40 x 25 3450 41.91 45.72 0.67 2 x 1 840007694 DX063 500 1.73 2.02 2.10 50 x 25 3450 43.94 51.30 0.95 BB A A croSS Ductile Iron Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 03.03.06-00 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF Cast & Ductile Iron Fittings ® Material SpecificationS Ductile iron threaded fittings are UL & ULC Listed & Factory Mutual Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-2. Dimensions conform to ASMe B6.3 Class 50. Threads are NPT per ANSI/ASMe B.20.. Notice: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened three turns beyond hand tight, but no more than four turns. capS Nominal Size Anvil Item Number Universal Number Max. Working Pressure Dimensions A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 840005615 DCP003 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 840005623 DCP004 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 840005631 DCP005 500 1.33 0.60 40 3450 33.78 0.272840005649DCP006 500 1.45 0.91 50 3450 36.83 0.41 A cap Ductile Iron FP-4.12 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: The MT-30 mechanical tee serves the same function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space and for easier installation in tight places.The MT-30 is ideal for direct connections with sprinkler heads and drop nipples. The MT-90 is the BSPT equivalent. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE J429 Gr. 2, zinc plated complete with hex flanged lock nuts conforming to ASTM A-563 Gr. A or B of SAE J995 Gr. 2. THREADS: NPT per ANSI/ASME B1.20.1. COATINGS: q Zinc Electroplated q Other available options: Example: RAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000. q Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. FIG. MT-30 Threaded Mechanical Branch Tee For Listings/Approval Details and Limitations,visit our website at www.anvilintl.com orcontact an Anvil® Sales Representative. FP-4.12 MT-30 THREADED MECHANICAL BRANCH TEE Nominal Size O.D.Hole Dimensions Max.WorkingPressures Dimensions Approx.Wt. Ea.Min. Diameter Max. Diameter A B C TTake-out In./DN(mm)In./mm In./mm In./mm PSI/bar In./mm In./mm In./mm In./mm Lbs./Kg 11⁄4 x 1⁄2 1.660 x 0.840 13⁄16 15⁄16 300 21⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 12 42.4 x 21.3 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 3⁄4 1.660 x 1.050 13⁄16 15⁄16 300 21⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 19 42.4 x 26.7 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 1 1.660 x 1.315 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 15⁄8 1.1 32 x 25 42.4 x 33.7 30 33 20.7 58 89 57.2 41 0.5 11⁄2 x 1⁄2 1.900 x 0.840 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 13⁄4 0.8 40 x 12 48.3 x 21.3 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 3⁄4 1.900 x 1.050 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 13⁄4 0.9 40 x 19 48.3 x 26.7 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 1 1.900 x 1.315 13⁄16 15⁄16 300 23⁄8 31⁄2 21⁄4 13⁄4 1.1 40 x 25 48.3 x 33.7 30 33 20.7 61 89 57.2 48 0.5 2 x 1⁄2 2.375 x 0.840 13⁄16 15⁄16 300 21⁄2 33⁄4 21⁄4 2 0.9 50 x 12 60.3 x 21.3 30 33 20.7 64 95 57.2 51 0.4 2 x 3⁄4 2.375 x 1.050 13⁄16 15⁄16 300 21⁄2 33⁄4 21⁄4 2 0.9 50 x 19 60.3 x 26.7 30 33 20.7 64 95 57.2 51 0.4 2 x 1 2.375 x 1.315 13⁄16 15⁄16 300 25⁄8 33⁄4 21⁄4 2 1.1 50 x 25 60.3 x 33.7 30 33 20.7 67 95 57.2 50 0.5 21⁄2 x 1⁄2 2.875 x 0.840 13⁄16 15⁄16 300 23⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 12 73.0 x 21.3 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 3⁄4 2.875 x 1.050 13⁄16 15⁄16 300 23⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 19 73.0 x 26.7 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 1 2.875 x 1.315 13⁄16 15⁄16 300 27⁄8 41⁄4 21⁄4 21⁄4 1.1 65 x 25 73.0 x 33.7 30 33 20.7 73 108 57.2 56 0.5 For dry pipe systems and freezer applications lubrication of the gasket is required,Gruvlok® Xtreme™ Lubricant is required. BSP equivalent is available as a MT-90. s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Note: Tighten nuts alternately to a recommended torque of 18-22 ft.-lbs. (25-30 Nm) on pipe wall less than schedule 10 (Din 2440) or 23-27 ft.-lbs. (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. FIG. MT-30 Threaded Mechanical Branch Tee OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 90 www.tolco.com Revision 3/1/2007 Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21⁄2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31⁄8 25⁄8 400 11 3/4 3/8 8mm or 10mm 31⁄8 21⁄2 400 11 1 3/8 8mm or 10mm 33⁄8 25⁄8 400 12 11⁄4 3/8 8mm or 10mm 33⁄4 27⁄8 400 13 11⁄2 3/8 8mm or 10mm 37⁄8 27⁄8 400 14 2 3/8 8mm or 10mm 41⁄2 3 400 15 21⁄2 3/8 10mm 55⁄8 41⁄8 600 27 3 3/8 10mm 57⁄8 4 600 29 31⁄2 3/8 10mm 73⁄8 51⁄4 600 34 4 3/8 10mm 73⁄8 5 1000 35 5 1/2 12mm 91⁄8 61⁄4 1250 66 6 1/2 12mm 101⁄8 63⁄4 1250 73 8 1/2 12mm 131⁄8 83⁄4 1250 136 Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330 Customer Service •800.786.5266 www.tolco.com 72 www.tolco.com Revision 5/24/2001 ™ ®a brand of Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Visit Hilti Online US www.us.hilti.com Canada www.ca.hilti.com Listings/Approvals ICC-ES (International Code Council) Evaluation Report No. 5264 COLA (City of Los Angeles) Research Report No.25350 FM (Factory Mutual) 4.3.7.4 Installation Instructions 4.3.7.5 Ordering Information 4.3.7.3 Technical Data Average Ultimate Loads, lb (kN)Allowable Loads, lb (kN) 4000 psi Concrete Hollow Core 4000 psi Concrete Hollow Core Length Bit Size 1 (27.6 MPa) (Spancrete) (27.6 MPa) (Spancrete) Desc. in.(mm)in. Tension Shear Tension Shear Tension Shear Tension Shear HDI-P 3/8 3/4 (19.1) 1/2 1900(8.5)3000(13.3)2100 (9.3)4000 (17.8)380 (1.7)600 (2.7)420(1.9)800 (3.6) 1. Set depth gauge on drill. 2. Hammer-drill hole. 3. Clean hole. 4. Insert anchor. 5. Insert setting tool and strike with hammer until anchor is fully set. 6. Collar of setting tool will leave an indentation on flange of anchor when properly expanded. HDI-P Anchor Item No. Description Box Qty 00283611 HDI-P 3/8 100 Setting Tools for HDI-P Anchors Item No.Description 00283611 HSD-G 3/8" – 3/4" Setting Tool w/ hand guard 00253784 HST-P 3/8" – 3/4" Setting Tool 1 For Hilti matched tolerance carbide tipped drill bits, see section 8.4.1. The Hilti HDI-P Drop-In anchor is an internally threaded, flush mounted expansion anchor for solid and hollow concrete. Product Features • Optimized 3/4" anchor length to allow reliable fastenings in hollow core panels,precast plank & post tensioned slabs • Shallow drilling enables fast installation • Lip provides flush installation, consistent anchor depth and easy rod alignment • Setting tool leaves mark on flange when anchor is set properly to enable inspection & verification of proper expansion Guide Specifications Expansion Anchor Expansion anchors shall be flush or shell type and zinc plated in accordance with ASTM B 633, SC 1,Type III. Anchors shall be Hilti HDI-P anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits.Install anchors in accordance with manufacturer’s recommendations. 4.3.7.2 Material Specifications The HDI-P is manufactured from mild carbon steel, which is zinc plated for corrosion protection in accordance with ASTM B 633, SC 1,Type III HDI-P Drop-In Anchor 4.3.7 Mechanical Anchoring Systems 185Hilti,Inc.(US)1-800-879-8000 I Product Technical Guide 2004 I Hilti (Canada) Corporation 1-800-363-4458 4.3.7 HDI-P 4.3.7.1 Product Description 4.3.7.2 Material Specifications 4.3.7.3 Technical Data 4.3.7.4 Installation Instructions 4.3.7.5 Ordering Information 4.3.7.1 Product Description HDI-P Specification Table