Loading...
HomeMy WebLinkAboutF14-0066 product submittal.pdfVAIL VILLAGE WELCOME CENTER ADDITION & REMODEL VAIL, COLORADO PRODUCT SUBMITTALS THIS SET OF FIRE SPRINKLER SHOP SPECIFICATIONS AND HYDRAULIC CALCULATIONS HAVE BEEN REVIEWED AND FOUND TO BE ACCEPTABLE – N.I.C.E.T. IV #102055 SR. ENGINEERING TECHNICIAN – FIRE PROTECTION, NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNICIANS _________________________________________________ ________/________/__________ TIMOTHY N TROSTEL, JR – SET DATE PHOENIX AUTOMATIC SPRINKLER 7684 S. BRENTWOOD ST. LITTLETON, CO 80128 720.922.9231 PHONE Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 10 JULY 2010 TFP171 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Technical Services 800-381-9312 | +1-401-781-8220 www.tyco-fire.com General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan-cies such as banks, hotels, and shop-ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applica-ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following, • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo-spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli-cable approval agencies, the testing is not representative of all possible cor-rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit-ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech-nical Data Sheet TFP780. NOTICE The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli-cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu-facturer should be contacted with any questions. Model/Sprinkler Identification Number (SIN) TY1131: Upright 2.8K, 1/2˝ NPT TY1231: Pendent 2.8K, 1/2˝ NPT TY2131: Upright 4.2K, 1/2˝ NPT TY2231: Pendent 4.2K, 1/2˝ NPT TY3131: Upright 5.6K, 1/2˝ NPT TY3231: Pendent 5.6K, 1/2˝ NPT TY4131: Upright 8.0K, 3/4˝ NPT TY4231: Pendent 8.0K, 3/4˝ NPT TY4831: Upright* 8.0K, 1/2˝ NPT TY4931: Pendent* 8.0K, 1/2˝ NPT *Eastern Hemisphere Sales Only TFP171 Page 2 of 10 WRENCH (38,1 mm)(55,6 mm) 2-7/8" (73,0 mm) DIA. 1 3 1/2" NPT SSP DEFLECTOR FLATS STYLE 10 or 20RECESSEDESCUTCHEON 7/16" (11,1 mm) 5 4 2 6 7/16" MAKE-INNOMINAL (11,1 mm) 2-3/16" DEFLECTORSSU ESCUTCHEONPLATE SEATING (55,6 mm) SURFACE 1-1/2" 1/2"NPT NOMINALMAKE-IN 2-3/16" RECESSED PENDENTCROSS SECTION UPRIGHT PENDENT * * * FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT PENDENTCROSS SECTION UPRIGHT RECESSED PENDENT SSP DEFLECTOR 2-1/4"(57,2 mm) (39,7 mm)1-9/16" PLATE SEATINGSURFACE ESCUTCHEON 1/2"NPT WRENCH FLATS MAKE-INNOMINAL 7/16" (11,1 mm) MAKE-INNOMINAL (11,1 mm)7/16" 2-3/16"(55,6 mm) SSUDEFLECTOR 2 7 1 3 5 4 6 2-7/8" (73,0 mm) DIA. RECESSEDSTYLE 10 or 20 ESCUTCHEON 1/2" NPT * * * 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw 7 - Bushing 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw TFP171 Page 3 of 10 SSP DEFLECTOR WRENCH(55,6 mm) 1 3 1/2" NPT FLATS 5 4 2 6 7/16" (11,1 mm) SSU DEFLECTOR 7/16" 2-3/16" NOMINAL MAKE-IN (11,1 mm) NOMINAL MAKE-IN 1/2" NPT (38,1 mm) 2-7/8" (73,0 mm) DIA. STYLE 10 or 20ESCUTCHEON 2-3/16"(55,6 mm) 1-1/2" PLATE SEATING SURFACE RECESSED ESCUTCHEON PENDENTCROSS SECTION UPRIGHT RECESSED PENDENT * * * (39,7 mm)(57,2 mm) 1 3 3/4" NPT SSP DEFLECTOR 2-7/8" (73,0 mm) DIA. (12,7 mm) MAKE-INNOMINAL 5 4 2 2-1/4" 6 ESCUTCHEON1/2" (12,7 mm) 1/2" DEFLECTOR SSU NOMINALMAKE-IN 1-9/16" 2-5/16"(58,7 mm) PLATE SEATINGSURFACE3/4" NPT STYLE 30 or 40 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT * * * FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw TFP171 Page 4 of 10 † Registered Trademark of Dupont Technical Data ApprovalsUL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K=8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical CharacteristicsFrame. . . . . . . . . . . . . . . . . . .Bronze Button. . . . . . . . . . . . . .Brass/Copper Sealing Assembly. . . . . . . . .Beryllium Nickel w/Teflon† Bulb . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw. . . . . . . .Bronze Deflector. . . . . . . . . . .Copper/Bronze Bushing (K=2.8) . . . . . . . . . . .Bronze (39,7 mm)WRENCH(55,6 mm)3 1 DEFLECTOR1/2" NPT SSP FLATS DEFLECTOR (11,1 mm) NOMINAL 2 4 5 6 MAKE-IN 2-3/16" 7/16" 7/16" (11,1 mm) 1/2"NPT NOMINAL MAKE-IN SSU 2-1/4"(57,2 mm) 1-9/16" SECTION CROSS PENDENTUPRIGHT * * * FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa-tion rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Preven-tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB Sprinklers must be installed in accordance with the following instructions. NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin-kler held horizontally, a small air bub-ble should be present. The diameter of the air bubble is approximately 1/16 1 - Frame 3 - Sealing Assembly 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to orifice seat on frame.2 - Button 5 - Compression Screw inch (1,6 mm) for the 135°F/57°C and 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. Obtain a leak-tight 1/2 inch NPT sprin-kler joint by applying a minimum to maximum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with con-sequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch-eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. 1. Install Pendent sprinklers in the pendent position. Install upright sprinklers in the upright position. 2. With pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 3. Tighten the sprinkler into the sprin-kler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With reference to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1, 2, 3, 4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY1231)* Figure 6 135°F/57°C Orange 1, 2, 4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231)** Figure 7 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57°C Orange 1, 2 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)** Figure 9 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED WHITE*** POLYESTER LEAD COATED 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY3231)** Figure 11 135°F/57°C Orange 1, 2, 3, 4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Orange 1, 2, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1, 2, 3, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) or Style 40 (3/4” NPT) 3/4” Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2” NPT) or Style 30 (3/4” NPT) 1/2” Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor-dance with the following instructions. 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica-ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. 2. Tighten the sprinkler into the sprin-kler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Fig-ure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. 3. After ceiling installation and finish-ing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Exercise care to avoid damage to sprinklers before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Replace sprinklers that: • were modified or over-heated. • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. • are leaking or exhibiting visible signs of corrosion. • were exposed to corrosive products of combustion but have not oper-ated, if you cannot easily remove combustion by-products with a cloth. • have a cracked bulb or have lost liq-uid from the bulb. Refer to the Instal-lation section in this data sheet. SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS CHROME PLATED WHITE POLYESTER LEAD COATED 2.8 1/2” NPT PENDENT (TY1231) and UPRIGHT (TY1131)75 PSI (12,1 BAR)N/A RECESSED PENDENT (TY1231) 4.2 1/2” NPT PENDENT (TY2231) and UPRIGHT (TY2131)175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) 5.6 1/2” NPT PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) OR 175 PSI (12,1 BAR) (SEE NOTE 1) 175 PSI (12,1 BAR) RECESSED PENDENT (TY3231)N/A 8.0 3/4” NPT PENDENT (TY4231) and UPRIGHT (TY4131)175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED PENDENT (TY4231)N/A 8.0 1/2” NPT PENDENT (TY4931) and UPRIGHT (TY4831)175 PSI (12,1 BAR)175 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE TFP171 Page 8 of 10 Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin-kler condition and the long-term integ-rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Responsibility lies with the owner for the inspection, testing, and mainte-nance of their fire protection system and devices in compliance with this document, as well as with the appli-cable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic-tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec-ommended to be inspected, tested, and maintained by a qualified Inspec-tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam-age to the sprinklers -before, during, and after installation. Sprinklers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT (57,2 mm)2-1/4" DIA. (73,0 mm)2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm)5/8±1/4" (3,2 mm) 13/16" (20,6 mm) 1-5/16" (33,3 mm) PLATEMOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB (12,7±3,2 mm)1/2±1/8" 2-1/4" DIA.(57,2 mm) (73,0 mm)2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1-1/16" (27,0 mm) 1-5/16" (33,3 mm) PLATEMOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT (57,2 mm)2-1/4" DIA. (73,0 mm)2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm)5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT (12,7±3,2 mm)1/2±1/8" 2-1/4" DIA.(57,2 mm) (73,0 mm)2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1" (25,4 mm) 1-1/4" (31,8 mm) PLATE MOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRB SERIES FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT (57,2 mm)2-1/4" DIA. (73,0 mm)2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SERIES SURFACE FACE OF FITTING (15,9±6,4 mm)5/8±1/4" (3,2 mm) 3/4" (19,1 mm) 1-1/4" (31,8 mm) PLATEMOUNTING 1/8" 1/4" (6,4 mm) 3/4" (19,1 mm) TY-FRB (12,7±3,2 mm)1/2±1/8" 2-1/4" DIA.(57,2 mm) (73,0 mm)2-7/8" DIA. SPRINKLER MOUNTING CLOSURE SURFACE FACE OF FITTING (3,2 mm) 1" (25,4 mm) 1-1/4" (31,8 mm) PLATEMOUNTING 1/8" 1/4" (6,4 mm) 1/2" (12,7 mm) TY-FRBSERIES FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA.(73,0 mm) 2-1/4" DIA.(57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (12,7±3,2 mm)1/2±1/8" 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) MOUNTING PLATE (3,2 mm)1/8" 1/2" (12,7 mm) 1/4" (6,4 mm) SERIES TY-FRB FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8" DIA.(73,0 mm) 2-1/4" DIA.(57,2 mm) MOUNTING SPRINKLER CLOSURE SURFACE FITTING FACE OF (15,9±6,4 mm)5/8±1/4" MOUNTING PLATE 1-5/16" (33,3 mm) 13/16" (20,6 mm) (3,2 mm)1/8" 3/4" (19,1 mm) 1/4" (6,4 mm) SERIES TY-FRB FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS(END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS(END "B" USED FOR3/4" NPT MODELS) RECESS WRENCH PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREAFIGURE 14 W-TYPE 6 SPRINKLER WRENCH FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin-kler condition and the long-term integ-rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. Copyright © 2007-2010 Tyco Fire Suppression & Building Products. All rights reserved. TFP171 Page 10 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod-ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com-ponents which have been subject to misuse, improper installation, corro-sion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Associa-tion, and/or the standards of any other Authorities Having Jurisdiction. Mate-rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP’s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete infor-mation supplied by Buyer or Buyer’s representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam-ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP’s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer-chantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materi-als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread ConnectionsSpecify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*). Sprinkler WrenchSpecify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. * Refer to Technical Data Sheet TFP770. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS P/N 57 – XXX – X – XXX SPRINKLER FINISH 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) MODEL/SIN 330 2.8K UPRIGHT (1/2”NPT)TY1131 331 2.8K PENDENT (1/2”NPT)TY1231 340 4.2K UPRIGHT (1/2”NPT)TY2131 341 4.2K PENDENT (1/2”NPT)TY2231 370 5.6K UPRIGHT (1/2”NPT)TY3131 371 5.6K PENDENT (1/2”NPT)TY3231 390 8.0K UPRIGHT (3/4”NPT)TY4131 391 8.0K PENDENT (3/4”NPT)TY4231 360 8.0K UPRIGHT (1/2”NPT)TY4831* 361 8.0K PENDENT (1/2”NPT)TY4931* * Eastern Hemisphere sales only. Series DS-1 Dry-Type Sprinklers Quick Response, Standard Coverage 5.6 K-factor, 3/4 and 1-Inch NPT Page 1 of 10 OCTOBER 2010 TFP510 IMPORTANTAlways refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and in-stallation of sprinkler systems and components. Improper handling and installation can permanently dam-age a sprinkler system or its compo-nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Technical Services 800-381-9312 | +1-401-781-8220 www.tyco-fire.com General Description The TYCO Series DS-1, 5.6 K-factor, 3/4 and 1-Inch NPT, Quick Response, Standard Coverage, Dry-Type Sprink-lers are decorative, 3-mm glass bulb automatic sprinklers de signed for com-mercial use. Dry-Type Sprinklers are typically used where: • pendent sprinklers are re quired on dry pipe systems that are exposed to freezing tempera tures; for example, sprinkler drops from un heated por-tions of buildings. • sprinklers and/or a portion of the con-necting piping are exposed to freezing temperatures; for example, sprinkler drops from wet sys tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors. • sprinklers are used on sys tems that are seasonally drained to avoid freezing; for example, vacation areas. NOTICE The Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica-ble standards of the National Fire Protection Association, in addition to the standards of any authorities hav ing jurisdiction. Failure to do so may impair the performance of these de vices. Owners are responsible for maintain ing their fire protection system and de vices in proper operating condition. The in-stalling contractor or sprinkler manu-facturer should be contacted with any questions. The Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers (SINs) 3/4-Inch NPT: TY3935 - Pendent TY3735 - Horizontal Sidewall 1-Inch NPT: TY3235 - Pendent TY3135 - Upright TY3335 - Horizontal Sidewall TFP510 Page 2 of 10 1-INCH NPT TY3235 Pendent with Standard Recessed Escutcheon (Figure 4) TY3235 Pendent with Standard Escutcheon (Figure 3) with Deep Escutcheon (Figure 5) without Escutcheon (Figure 6) TY3135 Upright without Escutcheon (Figure 7) TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling Distance of 4 to 12 inches (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C)Orange 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 155°F (68°C)Red 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 175°F (79°C)Yellow 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 200°F (93°C)Green 1, 2, 3 1, 2 1, 2, 3 1, 2 1*, 2*, 3**1*, 2* 286°F (141°C)Blue N/A 1, 2, 3 1, 2 1*, 2*, 3** 1*, 2* TABLE B 1-INCH NPT AND ISO 7-R1, SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (maximum order length of 48 inches). 4. The Upright Sprinkler without an Escutcheon (TY3135) is available in 1-Inch NPT only. * Light and Ordinary Hazard Occupancies Only / ** Light Hazard Occupancies Only / N/A - Not Available TABLE A 3/4-INCH NPT, SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 3/4-INCH NPT TY3935 Pendent with Standard Recessed Escutcheon (Figure 4) TY3935 Pendent with Standard Escutcheon (Figure 3) with Deep Escutcheon (Figure 5) without Escutcheon (Figure 6) TY3735 Horizontal Sidewall with Top of Deflector-to-CeilingDistance of 4 to 12 inches (100 to 300 mm) with Standard Escutcheon (Figure 8) with Deep Escutcheon (Figure 9) without Escutcheon (Figure 10) Temperature Rating Bulb Color Code Finish Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester Natural Brass Chrome Plated White Polyester 135°F (57°C)Orange 1, 2 1, 2 1*, 2* 155°F (68°C)Red 1, 2 1, 2 1*, 2* 175°F (79°C)Yellow 1, 2 1, 2 1*, 2* 200°F (93°C)Green 1, 2 1, 2 1*, 2* 286°F (141°C)Blue N/A 1, 2 1*, 2* Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches). * Light and Ordinary Hazard Occupancies Only / N/A - Not Available TFP510 Page 3 of 10 WATERTUBE VENT HOLE GUIDE TUBE SEALING PLUG WITH DEFLECTOR SPRING ASSEMBLY FRAME 3 mm BULB INSERT YOKE SCREW INLET CASING BULB COMPRESSION SEAT INLETBAND WATER TUBE VENT HOLE GUIDE TUBE 3 mm BULB INSERT SPRING SCREW INLET SEALING PLUG WITH CASING DEFLECTOR BULB YOKE COMPRESSION SEAT ASSEMBLY FRAME SPRINGPLUG INLETBAND FIGURE 2 SERIES DS-1, 1-INCH NPT AND ISO 7-R1, QUICK RESPONSE DRY-TYPE SPRINKLER ASSEMBLY FIGURE 1 SERIES DS-1, 3/4-INCH NPT, QUICK RESPONSE DRY-TYPE SPRINKLER ASSEMBLY Technical Data ApprovalsUL and C-UL ListedFM Approved Refer to Tables A and B. Maximum Working Pressure175 psi (12,1 bar) Inlet Thread Connection3/4-Inch NPT1-Inch NPT or ISO 7-R1 Discharge CoefficientK = 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature RatingsRefer to Tables A and B. FinishesSprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated, Chrome Plated, Brass Plated Physical Characteristics Inlet. . . . . . . . . . . . . . . . . . . . . Copper Plug . . . . . . . . . . . . . . . . . . . . Copper Yoke . . . . . . . . . . . . . .Stainless Steel Casing . . . . .Galvanized Carbon Steel Insert . . . . . . . . . . . . . . . . . . Bronze Bulb Seat . . . . . . . . . . .Stainless Steel Bulb . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . .Bronze Deflector . . . . . . . . . . . . . . . . Bronze Frame . . . . . . . . . . . . . . . . . . .Bronze Guide Tube . . . . . . . . .Stainless Steel Water Tube . . . . . . . . .Stainless Steel Spring . . . . . . . . . . . . .Stainless Steel Plug Spring*. . . . . . . . .Stainless Steel Sealing Assembly . . . . . . . . Beryllium Nickel w/Teflon** Escutcheon . . . . . . . . .Carbon Steel Patents U.S.A. Patent No. 5,188,185 *For 3/4-Inch NPT only **Registered trademark of DuPont TFP510 Page 4 of 10 FIGURE 5 TY3235 AND TY3935 PENDENTWITH DEEP ESCUTCHEON ORDER LENGTHS: INCREMENTS 4-1/4" ± 1/8"(108,0 ± 3,2 mm) IN 1/4" (6,4 mm) (12,7 to 1168,4 mm)1/2" to 46" FACE OFCEILING (88,9 mm)3-1/2" DIA. 2-1/2" DIA.(63,5 mm) FITTING FACE OF SPRINKLER CRITERIA SECTION) (REFER TO DESIGNSPRINKLER FITTING FIGURE 6 TY3235 AND TY3935 PENDENTWITHOUT ESCUTCHEON FIGURE 3 TY3235 AND TY3935 PENDENTWITH STANDARD ESCUTCHEON FIGURE 4 TY3235 AND TY3935 PENDENT WITH STANDARD RECESSED ESCUTCHEON 2-1/4" DIA.(57,2 mm) 1-3/8" ± 1/8"(34,9 ± 3,2 mm) 2-7/8" DIA.(73,0 mm) IN 1/4" (6,4 mm) 3-3/4" to 48" INCREMENTS (95,3 to 1219,2 mm) ORDER LENGTHS: SPRINKLERFACE OF FITTING CEILING FACE OF CRITERIA SECTION)(REFER TO DESIGNSPRINKLER FITTING ORDER LENGTHS: (69,9 to 1219,2 mm)2-3/4" to 48" IN 1/4" (6,4 mm) INCREMENTS FITTING FACE OF SPRINKLER SPRINKLER FITTING(REFER TO DESIGN CRITERIA SECTION) (76,2 mm)3" DIA. 1-3/4" DIA.(44,5 mm) (55,6 ± 3,2 mm)2-3/16" ± 1/8" CEILINGFACE OF SPRINKLERFACE OF FITTING (127,0 to 1219,2 mm) INCREMENTS IN 1/4" (6,4 mm) ORDER LENGTHS: 5" to 48" DEFLECTOR TO CEILING 1-3/4" (44,5 mm)MINIMUM SPRINKLER FITTING(REFER TO DESIGNCRITERIA SECTION) FIGURE 7 TY3135 UPRIGHT WITHOUT ESCUTCHEON— 1-INCH NPT ONLY — TOP OF DEFLECTOR CRITERIA SECTION)(REFER TO DESIGNSPRINKLER FITTING SPRINKLERFITTING FACE OF IN 1/4" (6,4 mm) INCREMENTS (127,0 to 1219,2 mm)5" to 48"ORDER LENGTHS: TFP510 Page 5 of 10 Operation When the TYCO Series DS-1 Dry-Type Sprinkler is in service, water is prevent-ed from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass Bulb contains a fluid that ex-pands when ex posed to heat. When the rated tem perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex pand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprin kler to activate and flow water. Design Criteria The TYCO Series DS-1 Sprinklers are intended for use in fire sprinkler sys-tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler FittingsInstall the 3/4 or 1-inch NPT Series DS-1 Dry-Type Sprinklers in the 3/4 or 1-inch NPT outlet or run of the follow-ing fittings: • malleable or ductile iron threaded tee fittings that meet the dimensional re-quirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125). Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprin-kler can contact the interior of the el-bow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figures 12 and 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1-inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water-filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. 3.5° 5/16"(7,9 mm)CENTERLINE OF WATERWAY (76,2 mm)3" DIA. 1-3/4" DIA.(44,5 mm) FITTING SPRINKLERFACE OF SPRINKLER FITTING CRITERIA SECTION)(REFER TO DESIGN 4" ± 1/8"(101,6 ± 3,2 mm) 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: SURFACE MOUNTINGFACE OF (88,9 mm)3-1/2" DIA. 2-1/2" DIA.(63,5 mm) 4-13/16" ± 1/8"(122,2 ± 3,2 mm) 3.5° 5/16"(7,9 mm)CENTERLINE OF WATERWAY FACE OF SPRINKLERFITTING 1/2" to 45-3/4" (12,7 to 1162,1 mm)IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS:FACE OF MOUNTINGSURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN 3.5°5/16"(7,9 mm) CENTERLINEOF WATERWAY FITTING SPRINKLER FACE OF 2-1/4" (57,2 mm) DEFLECTOR TO 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: MINIMUM MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN FIGURE 8 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH STANDARD ESCUTCHEON FIGURE 9 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH DEEP ESCUTCHEON FIGURE 10 TY3335 AND TY3735 HORIZONAL SIDEWALL WITHOUT ESCUTCHEON TFP510 Page 6 of 10 For wet pipe system installations of the 1-inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1" x 1" NPT Female Adapter (P/N 80145) • 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249). For wet pipe system installations of the the 3/4-inch NPT Series DS-1 Sprinklers connected to CPVC pip-ing, use in the 3/4" x 3/4" NPT Female Adapter (P/N 80142). For dry pipe system installations, use only the side outlet of maximum 2-1/2-inch reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Otherwise, use the con-figuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(a) 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length, Inches (mm)(b) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C)4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C)14 (355)4 (100)1 (25) -20°F (-29°C)14 (355)6 (150)3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C)20 (510)10 (255)6 (150) -60°F (-51°C)20 (510)10 (255)6 (150) Notes: (a) For protected area temperatures that occur between values listed above, use the next cooler temperature. (b) These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C MINIMUM RECOMMENDED LENGTHS OF EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS NOTICE Do not install the Series DS-1 Dry-Type Sprinkler into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: • Failure of the sprinkler to operate prop-erly due to formation of ice over the inlet Plug or binding of the Inlet Plug. • Insufficient engagement of the Inlet pipe threads with consequent leakage. DrainageIn accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem-peratures must be pitched for proper drainage. Exposure LengthWhen using Dry Sprinklers in wet pipe sprinkler systems to protect areas sub-ject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the connecting pipes due to conduction. The exposed bar-rel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insula-tion that is exposed to the heated area. Refer to Figure 11 for an example. Clearance SpaceIn accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when connecting an area subject to freez-ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to tem-perature differences between two ar-eas, the potential for the formation of condensation in the sprinkler and sub-sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP510 Page 7 of 10 FIGURE 12 SPRINKLER FITTING IN HEATED AREA SIDEOUTLETPLUGGED TO WETSYSTEM FITTING(SEE DESIGN CRITERIASECTION) SPRINKLERDSB-2INTENDED FOR FREEZER STRUCTURES HEATED AREA INSULATED FREEZERSTRUCTURE (ENDS ON OPPOSINGSIDES OF STRAP TIES BOOT) ADHESIVE SHOWN WITH STANDARD ESCUTCHEON DS-1 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER (SEE DESIGN CRITERIASECTION) FACE OFSPRINKLER FITTING LENGTH EXPOSURE DSB-2 INTENDEDFOR FREEZERSTRUCTURES HEATED AREA FIGURE 11 EXPOSURE LENGTH FIGURE 13 SPRINKLER FITTING IN UNHEATED AREA RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 INTENDEDFOR FREEZERSTRUCTURES FITTING(SEE DESIGN CRITERIASECTION) SPRINKLER AREA SUBJECTTOFREEZING FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER INSULATED FREEZER STRUCTURE (ENDS ON OPPOSING SIDES OF STRAP TIES BOOT) ADHESIVE SHOWN WITH STANDARD ESCUTCHEON DS-1 1-3/4" DIA.(44,5 mm) CLEARANCE HOLE DSB-2 BOOT TFP510 Page 8 of 10 Installation The TYCO Series DS-1 Dry-Type Sprinklers must be installed in accor-dance with the following instructions. NOTICE The Series DS-1 Dry-Type Sprinkler must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important re-quirements regard ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin-kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 286°F (141°C) rating. • Obtain a leak-tight 3/4-inch NPT sprin-kler joint by applying a minimum-to-maximum torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). • Obtain a leak-tight 1 inch NPT sprin-kler joint by applying a minimum-to-maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright posi-tion. The deflector of a pendent or upright sprin kler must be parallel to the ceiling. Install horizontal sidewall sprin-klers in the horizontal position with their centerline of waterway perpen-dicular to the back wall and paral-lel to the ceiling. Ensure the word “TOP” on the De flector faces the ceiling. 2. With a non-hardening pipe-thread sealant such as Teflon1 tape applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. 3. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing (Figures 1 and 2) • the W-Type 7 Sprinkler Wrench on the Wrench Flat (Figure 16). 1 Registered trademark of DuPont Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching meth-od noted above. Sprinkler remov-al is easier when a non-hardening sealant was used and torque guide-lines were followed. After removal, inspect the sprinkler for damage. 4. After installing the ceiling or wall and applying a celing finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry-Type Sprinklers must be maintained and ser-viced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys-tems from the proper authorities and notify all personnel who may be affect-ed by this action. Absence of the outer piece of an es-cutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Figures 1 and 2) to indicate if the Dry-Type Sprinkler is remaining dry. Evi-dence of leakage from the Vent Hole in-dicates potential leakage past the Inlet seal and the need to remove the sprin-kler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec-tion system control valve and drain the system before removing the sprinkler. Exercise care to avoid dam age before, during, and after instal lation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cov-er plates with factory-painted units. Non-factory applied paint can adverse-ly delay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: • were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. • were modified or over-heated. • have cracked bulbs or have lost liquid from the bulbs. Refer to the Installation Section in this data sheet. • are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the in spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protec tion Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing con-tractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom-mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local re-quirements and/or national codes. RECESSWRENCH FLAT WRENCH WITH SPRINKLER ENGAGEMENTIN TO ENSURE WRENCHING AREA PUSH WRENCH FIGURE 16 W-TYPE 7 SPRINKLER WRENCH TFP510 Page 9 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are war ranted solely to the original Buyer for ten (10) years against defects in mate rial and workman-ship when paid for and properly in-stalled and maintained under normal use and service. This warranty will ex-pire ten (10) years from date of ship-ment by TFSBP. No warranty is given for products or com ponents manu-factured by companies not affiliated by ownership with TFSBP or for prod-ucts and components which have been subject to misuse, improper in-stallation, corrosion, or which have not been installed, maintained, modi-fied or repaired in accordance with ap-plicable Standards of the National Fire Protection Association, and/or the stan-dards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod ucts. TFSBP shall not be responsible for sprinkler system design errors or inac curate or incomplete information sup plied by Buyer or Buyer’s repre sentatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam-ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of mer-chantability and fitness for a particular purpose. This limited warranty sets forth the ex-clusive remedy for claims based on fail-ure of or defect in products, materi als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex-tent permitted by law. The invalidity, in whole or part, of any portion of thiswar-ranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product name and Part Number (P/N). Dry-Type SprinklersSpecify this dry-type sprinkler as follows: • Model/SIN from Page 1 • Quick Response, Standard Cover age, Dry-Type Sprinkler • Deflector Style • 5.6 K-Factor • Order Length Dry-Type Sprinklers are furnished based upon Order Length as mea-sured per Figures 3 through 10. After taking the measurement, round it to the nearest 1/4 inch increment. • Inlet Connection: 3/4-inch NPT, 1-inch NPT, or ISO 7-R1 • Temperature Rating • Sprinkler Finish • Escutcheon Style and Finish, as applicable • Part Number (P/N) from Table C The Upright Sprinkler without an Escutcheon (TY3135) is available in 1-Inch NPT only. Part Numbers are for 3/4-inch and 1-inch NPT stand ard order sprin-klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Sprinkler WrenchSpecify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Sprinkler BootSpecify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002. This Part Number includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive. The quantity of adhesive is sufficient for installing one Boot. TFP510 Page 10 of 10 Copyright ©2009 - 2010 Tyco Fire Suppression & Building Products. All rights reserved. TABLE C PART NUMBER SELECTION SERIES DS-1, 3/4 AND 1-INCH NPT, QUICK RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS (Use Prefix “I” for ISO 7-R1 Connection; for example, I-60-361-1-180) P/N 60 – XXX – X – XXX NOTES (1). Escutcheon Finish applies to sprinklers provided with escutcheons. (2). 286°F (141°C) temperature rating applies to non-recessed sprinkler assemblies. (3). Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. SAMPLE ORDER LENGTHS (3) 055 5.50” 082 8.25” 180 18.00” 187 18.75” 372 37.25” 480 48.00” MODEL/SIN 01 Pendent with Standard Escutcheon (3/4" NPT)TY3935 (Figure 3) 02 Pendent with Deep Escutcheon (3/4" NPT)TY3935 (Figure 5) 03 Pendent with Standard Recessed Escutcheon (3/4" NPT)TY3935 (Figure 4) 04 Pendent without Escutcheon (3/4" NPT)TY3935 (Figure 6) 05 Sidewall with Standard Escutcheon (3/4" NPT) TY3735 (Figure 8) 06 Sidewall with Deep Escutcheon (3/4" NPT) TY3735 (Figure 9) 07 Sidewall without Escutcheon (3/4" NPT) TY3735 (Figure 10) 36 Pendent with Standard Escutcheon (1" NPT)TY3235 (Figure 3) 33 Pendent with Deep Escutcheon (1" NPT)TY3235 (Figure 5) 37 Pendent with Standard Recessed Escutcheon (1" NPT)TY3235 (Figure 4) 32 Pendent without Escutcheon (1" NPT)TY3235 (Figure 6) 34 Sidewall with Standard Escutcheon (1" NPT) TY3335 (Figure 8) 43 Sidewall with Deep Escutcheon (1" NPT) TY3335 (Figure 9) 44 Sidewall without Escutcheon (1" NPT) TY3335 (Figure 10) 38 Upright without Escutcheon (1" NPT)TY3135 (Figure 7) SPRINKLER FINISH ESCUTCHEON FINISH (1) 1 NATURAL BRASS WHITE 4 WHITE POLYESTER WHITE 9 CHROME PLATED CHROME 0 CHROME PLATED WHITE 2 NATURAL BRASS BRASS PLATED TEMPERATURE RATINGS (2) 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) MODEL DD-1 MODEL DD-1 Wiliag™ Condensate Drain Features and Benefits • Ready to Install • No Power Machine for Repair • Eliminates Searching for Materials • Eliminates Potential Leaks • Eliminates Labor of Fabrication •Classic Look of a Professional Job •Net Weight Only 6.25 lbs. • Overall Length 24" (615 mm) • Turning Radius 2.5" (64 mm) Technical Data • Volume: 0.1875 gallons • Standard Working Pressure of 175 psi • Valve type and manufacturer may vary • Length: 24" (615 mm) • Turning radius 2.5" (64 mm) • Shipping weight: 6.26 pounds • U.S. Patent number 6,102,066 General Description The DD-1 Condensate Drain is a pre-man- ufactured drum drip for installation in Dry- Pipe, Deluge and Pre-Action Automatic Sprinkler Systems. The DD-1 Condensate Drain is made from Electric-Resistance-Welded Carbon and Alloy Steel Mechanical Tubing, ASTM A513. After the machining process is complete, the 1" male outlets shall have a wall thickness greater than or equal to 0.133 inches and an O.D. of 1.315 inches. Other drains are usually constructed from various parts that must be assembled at the time of installation. There is no comparison in the quality and look of the DD-1 Condensate Drain and it is quick and easy to install. (Always refer to Technical Data Sheet for complete description of all Listing criteria, design parameters, installation instructions, care and maintenance guidelines, and our Limited Warranty.) MODEL DD-1 Tyco Fire Products Technical Services Ph: 800-791-9312 Fax: 800-791-5500 www.Tyco-Fire.com Tyco Fire Products reserves the right to change product design and specifications 2 without notice. Copyright © 2004 Tyco Fire Products LP. All rights reserved. Printed in USA /DD-1/4M/CPI/09-04 Wiliag is a registered trademark of The Wiliag Company. Tyco is a registered trademark of Tyco and/or its affiliates in the United States and/orother countries. All other brand names, product names, or trademarks belong to their respective holders. 2.50 inches 24.0 inches1" Shut Off Valve1" Shut Off Valve1" Plug The Wiliag™ Condensate Drain includes: • One condensate barrel • Two 1" shut off valves (valve manufacturer may vary) • One 1" plug Traditional Field Generated Drum-Drip Ordering Procedure Contact your local distributor for availability. Model DD-1: Specify: Model DD-1 Condensate Drain P/N 52-380-1-001 S5 - 3 Galvanized Pipe Superior Coating Specifications & Approvals American Made Schedule-10/Schedule-40 product can be “hot-dip” galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000” in diameter is coated with our new Antibacterial For- mula, “ABF”. In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (11⁄4"– 8") pipe and Sch-40 (1"– 21⁄2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Fully Listed and FM Approved Sprinkler Pipe Schedule-10®/Schedule-40® Meets “Buy American” requirement and is available through distributors in the USA, Canada and Mexico. Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (H2O Filled) Pcs/ Wt/Lift (21')Wt/Lift (24')Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11⁄4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11⁄2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21⁄2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. Wt. Wt. (H2O Filled) Pcs/ Wt/Lift (21')Wt/Lift (24')Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11⁄4" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11⁄2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21⁄2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 FM Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 11350 Norcom Rd. • Philadelphia, PA 19154 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 Page 19 C.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 Cast iron threaded fittings are UL, ULC listed and factory mutual approved for 300 psi service. Gray iron per ASTM A126 class B. Dimensions conform to ANSI B16.4 class 125 except plugs conform to ASME B16.14. Threads are NPT per ANSI/ASME B1.20.1. CAST IRON 90 DEGREE ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CB90033 300 1.50 1.50 0.95 1 1/4 CB90044 300 1.75 1.75 1.34 1 1/2 CB90055 300 1.94 1.94 1.80 2 CB90066 300 2.25 2.25 2.90 2 1/2 DIMENSIONS CAST IRON STRAIGHT TEE NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CT333 300 1.50 1.50 1.21 1 1/4 CT444 300 1.75 1.75 1.87 1 1/2 CT555 300 1.94 1.94 2.51 2 CT666 300 2.25 2.25 3.96 DIMENSIONS CAST IRON RED. COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST IRON 45 DEGREE ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CB45033 300 1.12 1.12 0.84 1 1/4 CB45044 300 1.29 1.29 1.40 1 1/2 CB45055 300 1.43 1.43 1.80 2 CB45066 300 1.68 1.68 2.79 DIMENSIONS CAST IRON RED. 90 DEG. ELBOW NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 1/2X1 CB90053 300 1.65 1.80 1.51 DIMENSIONS 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 CAST IRON PLUGS NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 1 1/4 CPL004 300 1.36 0.44 1 1/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 CB90077 300 2.70 2.70 4.75 2 1/2 CT777 300 2.70 2.70 6.45 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 Page 20 C.I. THREADED FITTINGS For fire protection services request submittal GRS 1.3 CAST IRON CROSS NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CX033 300 1.50 1.50 1.54 1 1/4 CX044 300 1.75 1.75 2.40 1 1/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 DIMENSIONS CAST IRON REDUCING TEE NOMINAL ITEM MAX. WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1X3/4 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 1 1/2X1X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 1/2X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 DIMENSIONS 2x2x2 1/2 CT667 300 2.60 2.60 2.39 5.10 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 Main Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service •800.786.5266 www.tolco.com 86 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. •(21/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric ABLoad Lbs. Length 1/2 3/8 8mm or 10mm 3 1/8 25/8 400 11 3/4 3/8 8mm or 10mm 3 1/8 21/2 400 11 1 3/8 8mm or 10mm 3 3/8 25/8 400 12 11/4 3/8 8mm or 10mm 3 3/4 27/8 400 13 11/2 3/8 8mm or 10mm 3 7/8 27/8 400 14 2 3/8 8mm or 10mm 4 1/2 3 400 15 21/2 3/8 10mm 5 5/8 41/8 600 27 3 3/8 10mm 5 7/8 4 600 29 31/2 3/8 10mm 7 3/8 51/4 600 34 4 3/8 10mm 7 3/8 5 1000 35 5 1/2 12mm 9 1/8 61/4 1250 66 6 1/2 12mm 10 1/8 63/4 1250 73 8 1/2 12mm 13 1/8 83/4 1250 136 Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 951.737.5599 •Fax: 951.737.0330 Customer Service •800.786.5266 www.tolco.com 72 www.tolco.com Revision 5/24/2001 ™ ®a brand of Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10’ lengths Material — Carbon Steel Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 Page 4 Note: Screws must be installed with appropriate nut driver to comply with warranty WOOD — Sammys Item# Model Shk Lgth Shk Dia BoxQty Weight (per 100) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST100 1 1/4 100 5.00 1000 22 GST200 2 1/4 100 6.50 1000 23 GST300 3 1/4 100 7.50 1000 24 GST600 6 1/4 50 9.00 500 WOOD • 1/4" Rod (Vertical Mount) Use #14 NutDriver (Item#100) Approvals Item# Model Shk Lgth Shk Dia FM Test Load, lb. UL Test Loadlb. UL/FM Pipe Size Actual Pullout Box Qty 10 GST.75 3/4 1/4 564# -6 Ply 100 NFPA 11 GST10 1 1/4 210# -7/16 OSB 670# -3/4" Ply 100 UL•FM•NFPA 12 GST20 2 1/4 940# 850# 3/4-2 1/2 1760# - Fir 100 UL•NFPA 27 GST25-380 2 1/2 3/8 1500# 4 2113# -Fir 50 UL•FM•NFPA 13 GST30 3 1/4 1475# 1500# 3/4-4 2060# - Fir 100 NFPA 403 GST40 4 1/4 2180# -Fir 50 NFPA 14 GST60 6 1/4 2230# -Fir 50 WOOD • 3/8" Rod (Vertical Mount) Use #14 NutDriver (Item#100) Item# Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight (per 100) Case Qty 8GST2 2 1/4 1760# -Fir 50 7.00 500 06 GST2.5-380 2 1/2 3/8 2113# -Fir 50 10.00 500 15 GST3 3 1/4 2275# -Fir 50 10.50 500 16 GST4 4 1/4 2180# -Fir 50 10.60 500 17 GST6 6 1/4 2230# -Fir 50 10.95 500 WOOD • 1/2" Rod (Vertical Mount) Use #14SWNutDriver (Item#101) qqqqq Wood Flooring Wood Joist rrrrrDouble Sheetrock Ceiling qqqqq Minimum 2” imbedment into base material for NFPA 13 compliance Not less than 2” nominal width (1 1/2”)Not less than3” nominal thickness (2 1/2”)(depth or side of vertical member)For vertical use. Install in center of lower face. Installation per NFPA 13 Consult truss manufacturer for recommended installation point. TJI Joist / Truss #14 (Item #100-black) Sammys 1/4”, 3/8” rod #14SW (Item #101-red) Sidewinders & Sammys 1/2” rod UL Listings and CAD Drawings are available at www.SammySuperScrew.com * * *Pre-drilling may be required for items #27 and #06. Tools available on page 9. Page 5Note: Screws must be installed with appropriate nut driver to comply with warranty WOOD —Sidewinders Item # Model Shk Lgth Shk Dia Actual Shear/Pullout BoxQty Weight (per 100) Case Qty 4016 SWG100 1 1/4 100 7.50 1000 300 SWG200 2 1/4 1725# -Fir 100 8.00 1000 WOOD • 1/4" Rod(Horizontal Mount) Use #14SWNutDriver (Item#101) Approvals Item # Model Shk Lgth Shk Dia UL Test Loadlb. UL/FM Pipe Size Actual Shear/Pullout BoxQty Weight (per 100) C 18 SWG10 1 1/4 100 6.00 UL•NFPA 19 SWG20 2 1/4 1250# 3 1725# -Fir 100 7.00 UL•NFPA 26 SWG25-380 2 1/2 3/8 1500# 4 2249# -Fir 50 10.25 25 SWG30 3 1/4 50 8.50 WOOD • 3/8" Rod (Horizontal Mount) Use #14SWNutDriver (Item#101) #14SW (Item #101-red) Sidewinders & Sammys 1/2” rod SHEETROCK — Toggle Item# Model Shk Lgth Shk Dia Actual Pullout Pkg Qty Weight (per 100) Case Qty 70 SST30 3 1/4 450# Lath & Plaster 404# 2 Layers 5/8 Rock 50 12.00 500 SHEETROCK • 3/8" Rod (Vertical Mount) Use #14 NutDriver (Item#100) Minimum 2 1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Not less than 2” nominal width (1 1/2”) up to 3 1/2” pipe; not less than 3” nominal width 4” & 5” pipe Installation per NFPA 13 Floor Joist rrrrr TJI Joist / Truss Consult truss manufacturer for recommended installation point. Item# Model Shk Lgth Shk Dia Actual Pullout BoxQty Weight (per 100) Case Qty 71 SST300 3 1/4 450# Lath & Plaster 404# 2 Layers5/8 Rock 50 12.00 500 SHEETROCK • 1/4" Rod (Vertical Mount) Use #14 NutDriver (Item#100) qqqqq Prestressed Concrete #14 (Item #100-black) Sammys 1/4”, 3/8” rod *Pre-drilling may be required for item #26. Tools available on page 9. *