HomeMy WebLinkAboutFP3.pdfB.O. FINISHED CEILING @ 45' - 2 1/2"
GARAGE
113
MUDROOM
111
ENTRY
101
STAIRS
102
DINING ROOM
103
LIVING ROOM
110
KITCHEN
104
PANTRY
OFFICE
105
MASTER
BEDROOM
107
MASTER CLOSET
108
MASTER BATH
109
SHOWER
109B
W.C.
2 1/2" / 12"
2 1/2" / 12"
2 1/2" / 12"
2 1/2" / 12"
B.O. FINISHED CEILING @ 57' - 4 1/4"
B.O. FINISHED CEILING @ 55' - 5 3/8"
B.O. FINISHED CEILING @ 54' - 11 3/8"
J-BOX FOR DOWNSPOUT
DISPOSAL
HOT AND COLD
HOSE BIB
B.O. FINISHED CEILING @ 57' - 2 3/8"
B.O. STEEL BEAM @ 60' - 0 5/8" B.O. STEEL BEAM @ 60' - 11 5/8"
B.O. STEEL BEAM @ 63' - 4 3/4"
B.O. STEEL BEAM @ 55' - 7 1/4"
B.O. STEEL BEAM @ 57' - 2 5/8"
B.O. STEEL BEAM @ 57' - 3"
B.O. STEEL BEAM @ 59' - 10 3/8"
B.O. FINISHED CEILING @ 56' - 2 1/2"
B.O. FINISHED CEILING @ 56' - 2 1/2"
2 1/2" / 12"
B.O. FINISHED CEILING @ 54' - 11 1/4"
B.O. FINISHED CEILING @ 49' - 4 1/2"
SIM
DA Name: 2
DA Area: 480.80
exterior
exterior
54 heads for this project
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
JSPIWðߛ/PLQPðߜRIIORRUDUHDRYHU
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at at the base of the riser.
Hose stream allowance of is included in the above.
2 Master Suite
Harman Res 2722 Cortina Lane
0.1
IWð
107.6 gpm 125.4 psi
Res
4
Wet
19 ft/s
0 gpm
107.6 gpm
0 gpm
0 gpm
0 gpm
107.6 gpm
0 gpm
107.6 gpm
125.4 psi
136.9 psi
11.5 psi
3 6 15
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -5151 Bannock St.
Denver, CO 80216
303-291-1012
303-383-5023 FAX
firesprinkler@afssco.com
A FIRE SPRINKLERDESIGN COMPANY
Vail Fire & Emergency Services
04/07/15