Loading...
HomeMy WebLinkAboutFP4.pdfCLOSET 201 B.O. STEEL BEAM @ 67' - 8 1/2" B.O. STEEL BEAM @ 67' - 2 7/8" B.O. STEEL BEAM @ 70' - 4 1/4" B.O. STEEL BEAM @ 65' - 0 3/4" B.O. STEEL BEAM @ 63' - 4 3/4" J GARAGE LOFT 013E BEDROOM 013C F shower DA Name: 1 DA Area: 379.30 exterior 54 heads for this project This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area JSPIWðߛ/PLQPðߜRIIORRUDUHDRYHU - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 1 Upper Level Harman Res 2722 Cortina Lane 0.1 IWð 109.1 gpm 125.3 psi Res 4 Wet 19.11 ft/s 0 gpm 109.1 gpm 0 gpm 0 gpm 0 gpm 109.1 gpm 0 gpm 109.1 gpm 125.3 psi 136.9 psi 11.7 psi 3 6 15 ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@afssco.com A FIRE SPRINKLERDESIGN COMPANY Vail Fire & Emergency Services 04/07/15