HomeMy WebLinkAbout11_APP-PolyflexG-PDS.pdf F V POLYFLEX® Ga. cg O. PRODUCT DESCRIPTION % 0. Polyflex G membranes are premium, polyester reinforced APP modified bitumen roofing membranes specially designed for heat-welded applications. Constructed with premium POLYFLExG Atactic Polypropylene resins, and incorporating superior polyester reinforcing, Polyflex G provides an exceptionally durable roofing product which is easy to install and will provide long-term weathering performance. With a granulated surface (available in several colors) and a polyolefin 1 WHITE MO backing, Polyflex G exceeds all minimum ASTM standards for tensile strength, puncture • resistance and flexibility. Polyflex G membranes can also be used as flashing membranes in all applicable specifications, in accordance with recommended installation practices. 'a.s mm USES • Heat-welded cap sheet • Applied directly over an acceptable substrate or as part of a multi-ply system • New roofing, re-roofing, re-cover and for flashing details PRODUCT DATA Coverage(Nominal) 100 sq ft FEATURES AND BENEFITS Weight(Approx) 1 10lbs Roll Size 32'10"x 39 3/s" (10m x 1m) • Exceptional weathering characteristics Rolls/Pallet 20 • Puncture and tear resistant • Low-temp flexibility, exceptional tensile strength and elongation properties APPLICABLE STANDARDS TECHNICAL DESCRIPTION • ASTM D 6222 Type I • Miami Dade Code Compliance TEST METHOD PROPERTY TYPICAL • Factory Mutual Approved VALUE • UL Classified for use in class A, B or C roofs, as listed in the latest UL"Roofing ASTM D5147 Thickness, typical, mm (mils) 4.5 (1 80) Materials and Systems Directory" • ICC ESR-2018 ASTM D5147 Peak Load @ 23+/-2°C (73.4+/-3.6°F), MD 8.8 (50) • TDI and XMD, min, kN/m (lbf/in.) ASTM D5147 Elongation @ 23+/-2°C (73.4+/-3.6°F), MD 23 � '°� and XMD, min (%) �SII07 '"o c 4L us ASTM D5147 Tear Strength @ 23+/-2°C (73.4+/-3.6°F), 311 (70) min, N (Ibf) ASTM D5147 Low Temperature Flexibility, max, °C 1°F) 0(32) PRODUCT WARRANTY Polyglass USA, Inc. commercial roofing ASTM D5147 Granule Embedment, g 2 membranes can be backed with a manufacturer's warranty for up to 20 years when used as part of an approved,multi-ply roofing system. Please see your Polyglass USA, Inc. Sales or Technical AVAILABLE COLORS Representative for specifications and details. Top surface granule protection is available in a variety of colors such as: WATERPROOFING MATERIALS AND INSULATING SYSTEMS Black Buff Chestnut Grey Slate Oak [POLYGLAISS® Q White Red Blend Pine Green Heather Blend WeatherwoodMAPE/' GROUP /141(1° Va4le 1-800-222-9782 Copyright©201 1 by Polyglass U.S.A.,Inc.and all rights are reserved www.polyglass.com •dition Dale:08/11•Doc#Polyllee G h Lo POLYFLEX® G a APPLICATION INSTRUCTIONS Polyflex G is intended to be used as the primary weathering surface in new or re-roof applications. Polyflex G is to be applied as the outermost layer of a multi-ply roof system over a compatible Polyglass base or inner ply sheet. Polyflex G may be applied directly to non-combustible substrates. • Apply over clean, dry, dust and debris-free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When re-roofing, remove all prior roofing materials down to a clean debris-free substrate and properly close-off all abandoned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devices. • Wood decks shall have all joints blocked and properly supported. • Ensure the fire rating of the assembly over any combustible substrate. • Ensure the installation of Polyflex G does not prevent the ventilation of existing construction. • Do not apply over shingles or any granulated surface. • While installing Polyflex G: 1 . Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Install with traditional torch roofing techniques ensuring proper heating of the roofing material as not to expose the reinforcement. 4. Do not heat the substrate. 5. Position successive rolls providing a minimum 6" end lap and 3" side lap. Asphalt bleed out shall be 1/4" to 3/8" on all seams. 6. Laps shall be rolled with a 6"-wide roller immediately after heat welding. • Details and flashing may be installed using Polyflex G with torch applied techniques. Do not use cold adhesives or hot asphalt. Check project details for proper installation requirements. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.com General Line: (888)410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions?technical@polyglass.com Product Disclaimer.Unless otherwise incorporated into or part of a supplemental manufacturer's warranty, Polyglass warrants its product(s)against manufacturing defects in its product that directly results in leakage for a period of 5 years. Refer to material safety data sheet(MSDS)for specific data and handling of our products.All WATERPROOFING MATERIALS AND INSULATING SYSTEMS data furnished refers to standard production and is given in good faith within the applicable POLYGLASS® Q manufacturing and testing tolerances. G MAPET G R Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time with- u out prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products Vaale under conditions beyond its own control. 1-800-222-9782 For most current product data and warranty information, visit www.polyglass.com www.polyglass.com