Loading...
HomeMy WebLinkAboutB17-0130_A0.6_1496783981.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS WALL SYSTEMS: FLOOR ASSEMBLIES: F1-W VINYL PLANK ON EXISTING FLOOR ASSEMBLY Vinyl plank installed per manufacturer's specifications,over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. F1-C CARPET ON EXISTING FLOOR ASSEMBLY Carpet and pad, installed per manufacturer's specifications, over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. C1 GYPSUM BOARD CEILING CONSTRUCTION (1Hr-Rated) UL DESIGN NO. L521 & UL P533 5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses or joists. (TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies. CEILING SYSTEMS: NOTE: TO BE UPDATED UPON FINAL STRUCTURAL PLAN FLOOR SYSTEMS: NOTE: TO BE UPDATED UPON FINAL STRUCTURAL PLAN Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. NOTES ** Interior Walls Studs: 4 - 2x4 Wood Studs, 3 5/8" Metal Studs 6 - 2x6 Wood Studs, 6" Metal Studs 8 - 2x8 Wood Studs RE: See wall tags for stud sizes. **** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where recommended by manufacturer. Maintain required fire-rating. Refer to Structural Drawings for Bearing Walls and Shear Walls. RATED ASSEMBLIES (EXTERIOR): W1-1 WOOD SIDING @ RATED EXTERIOR WALLS Wood siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @ exterior face of 2x6 dimensional lumber studs w/ min. R-21 closed cell spray-in foam insulation between studs. (1) layer 5/8" gypsum board @ interior face of studs. Interior finish will be paint or FRP panels, see room finish schedule for finish. (Re: Structural for size and spacing of studs and sheathing). W1-2 STUCCO @ RATED EXTERIOR WALLS 3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, 2x6 dimensional lumber studs w/ R-21 closed cell spray-in foam insulation between studs. (1) layer 5/8" gypsum board @ interior face of studs. (Re: Structural for size and spacing of studs and sheathing). NON-RATED ASSEMBLIES (INTERIOR): W2-4 GYPSUM BOARD PARTITION ON 2X4 DIMENSIONAL LUMBER STUDS (Non-Rated) (1) Layer 5/8" gypsum board on each side of 2x4 dimensional lumber studs at non-bearing walls, demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). W2-6 GYPSUM BOARD PARTITION ON 2X6 DIMENSIONAL LUMBER STUDS (Non-Rated) (1) Layer 5/8" gypsum board on each side of 2x6 dimensional lumber studs at non-bearing walls, demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). (1Hr-Rated), R-50 Note: Install ice and water 24" up at vertical wall interface. Typical. Note: Install snow retention system and heat tape in accordance with manufacturer's instructions. 110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), ROOF SYSTEMS: NOTE: TO BE UPDATED UPON FINAL STRUCTURAL PLAN 2X6 DIMENSIONAL LUMBER INTERIOR SELF FURRING LATH EXTERIOR 1 LAYER ASPHALTIC BUILDING PAPER STRUCTURAL SHEATHING, RE: STRUCTURE W1-2 5/8" GYP. = 40 MIN. FIRE RATING (1-HOUR MIN.) : 3 COAT STUCCO SYSTEM CLOSED CELL SPRAY-IN INSULATION, R-21 MIN. 2X6 DIMENSIONAL LUMBER INTERIOR EXTERIOR CLOSED CELL SPRAY-IN INSULATION, R-21 MIN. BUILDING WRAP STRUCTURAL SHEATHING, RE: STRUCTURE W1-1 5/8" GYP. = 40 MIN. FIRE RATING (1-HOUR MIN.) : VERTICAL SIDING 5/8" GYPSUM WALL BOARD 0'-3 1/2" W2-4 2X4 DIMENSIONAL LUMBER @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. SOUND BATTS 5/8" GYPSUM WALL BOARD 0'-5 1/2" W2-6 2X6 DIMENSIONAL LUMBER, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. SOUND BATTS 2X12 RAFTERS RE: STRUCT DWGs R49 INSULATION (RSF) 5/8" APA RATED ROOF SHEATHING RE: STRUCT DWGs ROOF FELT ICE & WATER SHIELD BUILT-UP ROOF STRUCT STEEL BEAM(s) w/ BLOCKING 1 1/8" T & G APA STURDIFLOOR PLYWOOD RE: STRUCT. DWGS. FLOOR FINISH W8X W10X W8X STRUCT STEEL FRAMING AT MAX 32" O.C. - TYPICAL. RE: STRUCT. DWGS. STEEL BAR JOISTS 12 1/8" DEEP @ 24" O.C. 4" CONC. ON METAL DECK ACOUSTICAL PANEL CLG. SUSPENDED FROM JOISTS 5/8" PLYWOOD SHEATHING BUILT-UP ROOF 2 X 12 DIM LUMBER R-49 INSULATION STRUCT STEEL BEAM ICE & WATER SHEILD 5/8" TYPE 'X' GYPSUM BOARD 0'-3 1/2" W3-4 2X4 DIMENSIONAL LUMBER @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. SOUND BATTS EXTERIOR MATERIAL TO MATCH EXISTING ONE-HOUR RATED WALL 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 LOT 15 BIGHORN SUBDIVISION 291 BRIDGE ST, UNIT R-1 VAIL, CO 81657 A0.6 WALL, FLOOR & ROOF ASSEMBLIES PLAZA LODGE R-1 Project Number - 1547 04/20/17 PERMIT SET 3" = 1'-0" 2 WALL ASSEMBLY W1-2 - 3-COAT STUCCO SYSTEM 3" = 1'-0" 3 WALL ASSEMBLY W1-1 - VERTICAL SIDING 3" = 1'-0" 4 WALL ASSEMBLY W2-4 - 2X4 DIMENSIONAL LUMBER WALL 3" = 1'-0" 5 WALL ASSEMBLY W2-6 - 2X6 DIMENSIONAL LUMBER WALL 1 1/2" = 1'-0" 6 ROOF ASSEMBLY 1 1/2" = 1'-0" 7 3RD FLOOR ASSEMBLY 1 1/2" = 1'-0" 8 2ND FLOOR ASSEMBLY 1 1/2" = 1'-0" 9 DECK ASSEMBLY 3" = 1'-0" 10 WALL ASSEMBLY W3-4 - 2X4 DIMENSIONAL LUMBER WALL 1 HR Rated 06/06/17