HomeMy WebLinkAboutB17-0130_A0.6_1496783981.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS
WALL SYSTEMS:
FLOOR ASSEMBLIES:
F1-W VINYL PLANK ON EXISTING FLOOR ASSEMBLY
Vinyl plank installed per manufacturer's specifications,over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated
(exposure 1) wood structural panels over Pre-Manufactured floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.)
Install (1) layer 5/8" Type "x"gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S
of trusses.
F1-C CARPET ON EXISTING FLOOR ASSEMBLY
Carpet and pad, installed per manufacturer's specifications, over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated
(exposure 1) wood structural panels over Pre-Manufactured floor trusses at 24" o.c. maximum spacing (Re: Structural
Drawings.) Install (1) layer 5/8" Type "X" gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized
steel @ 16"o.c. on U/S of trusses.
C1 GYPSUM BOARD CEILING CONSTRUCTION
(1Hr-Rated) UL DESIGN NO. L521 & UL P533
5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses or joists.
(TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies.
CEILING SYSTEMS: NOTE: TO BE UPDATED UPON FINAL STRUCTURAL PLAN
FLOOR SYSTEMS: NOTE: TO BE UPDATED UPON FINAL STRUCTURAL PLAN
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies
prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both
architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound
and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.
NOTES
** Interior Walls Studs:
4 - 2x4 Wood Studs, 3 5/8" Metal Studs
6 - 2x6 Wood Studs, 6" Metal Studs
8 - 2x8 Wood Studs
RE: See wall tags for stud sizes.
**** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant
non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant
non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where
recommended by manufacturer. Maintain required fire-rating.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
RATED ASSEMBLIES (EXTERIOR):
W1-1 WOOD SIDING @ RATED EXTERIOR WALLS
Wood siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @
exterior face of 2x6 dimensional lumber studs w/ min. R-21 closed cell spray-in foam insulation between
studs. (1) layer 5/8" gypsum board @ interior face of studs. Interior finish will be paint or FRP panels,
see room finish schedule for finish. (Re: Structural for size and spacing of studs and sheathing).
W1-2 STUCCO @ RATED EXTERIOR WALLS
3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, 2x6 dimensional
lumber studs w/ R-21 closed cell spray-in foam insulation between studs. (1) layer 5/8" gypsum board
@ interior face of studs. (Re: Structural for size and spacing of studs and sheathing).
NON-RATED ASSEMBLIES (INTERIOR):
W2-4 GYPSUM BOARD PARTITION ON 2X4 DIMENSIONAL LUMBER STUDS (Non-Rated)
(1) Layer 5/8" gypsum board on each side of 2x4 dimensional lumber studs at non-bearing walls,
demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing).
W2-6 GYPSUM BOARD PARTITION ON 2X6 DIMENSIONAL LUMBER STUDS (Non-Rated)
(1) Layer 5/8" gypsum board on each side of 2x6 dimensional lumber studs at non-bearing walls,
demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing).
(1Hr-Rated), R-50
Note: Install ice and water 24" up at vertical wall interface. Typical.
Note: Install snow retention system and heat tape in accordance with manufacturer's instructions.
110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119),
ROOF SYSTEMS: NOTE: TO BE UPDATED UPON FINAL STRUCTURAL PLAN
2X6 DIMENSIONAL
LUMBER
INTERIOR
SELF FURRING LATH
EXTERIOR
1 LAYER ASPHALTIC
BUILDING PAPER
STRUCTURAL SHEATHING,
RE: STRUCTURE
W1-2
5/8" GYP. = 40 MIN.
FIRE RATING
(1-HOUR MIN.) :
3 COAT STUCCO SYSTEM
CLOSED CELL SPRAY-IN
INSULATION, R-21 MIN.
2X6 DIMENSIONAL
LUMBER
INTERIOR EXTERIOR
CLOSED CELL SPRAY-IN
INSULATION, R-21 MIN.
BUILDING WRAP
STRUCTURAL SHEATHING,
RE: STRUCTURE
W1-1
5/8" GYP. = 40 MIN.
FIRE RATING
(1-HOUR MIN.) :
VERTICAL SIDING
5/8" GYPSUM
WALL BOARD
0'-3 1/2"
W2-4
2X4 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
0'-5 1/2"
W2-6
2X6 DIMENSIONAL LUMBER,
SEE PLANS AND WALL TAG FOR
STUD SIZE, TYP.
SOUND BATTS
2X12 RAFTERS
RE: STRUCT DWGs
R49 INSULATION (RSF)
5/8" APA RATED ROOF SHEATHING
RE: STRUCT DWGs
ROOF FELT
ICE & WATER SHIELD
BUILT-UP ROOF
STRUCT STEEL
BEAM(s) w/
BLOCKING
1 1/8" T & G APA STURDIFLOOR PLYWOOD
RE: STRUCT. DWGS.
FLOOR FINISH
W8X
W10X
W8X
STRUCT STEEL FRAMING AT MAX 32"
O.C. - TYPICAL. RE: STRUCT. DWGS.
STEEL BAR JOISTS 12 1/8" DEEP @ 24" O.C.
4" CONC. ON METAL DECK
ACOUSTICAL PANEL CLG.
SUSPENDED FROM JOISTS
5/8" PLYWOOD SHEATHING
BUILT-UP ROOF
2 X 12 DIM LUMBER
R-49 INSULATION
STRUCT STEEL BEAM
ICE & WATER SHEILD
5/8" TYPE 'X'
GYPSUM BOARD
0'-3 1/2"
W3-4
2X4 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
EXTERIOR MATERIAL
TO MATCH EXISTING
ONE-HOUR RATED WALL
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
LOT 15 BIGHORN
SUBDIVISION
291 BRIDGE ST, UNIT R-1
VAIL, CO 81657
A0.6
WALL, FLOOR
& ROOF
ASSEMBLIES
PLAZA
LODGE R-1
Project
Number - 1547
04/20/17
PERMIT SET
3" = 1'-0"
2
WALL ASSEMBLY W1-2 - 3-COAT STUCCO
SYSTEM
3" = 1'-0"
3
WALL ASSEMBLY W1-1 - VERTICAL
SIDING
3" = 1'-0"
4
WALL ASSEMBLY W2-4 - 2X4
DIMENSIONAL LUMBER WALL
3" = 1'-0"
5
WALL ASSEMBLY W2-6 - 2X6
DIMENSIONAL LUMBER WALL
1 1/2" = 1'-0"
6
ROOF ASSEMBLY
1 1/2" = 1'-0" 7
3RD FLOOR ASSEMBLY
1 1/2" = 1'-0" 8
2ND FLOOR ASSEMBLY
1 1/2" = 1'-0" 9
DECK ASSEMBLY
3" = 1'-0"
10
WALL ASSEMBLY W3-4 - 2X4
DIMENSIONAL LUMBER WALL 1 HR Rated
06/06/17