Loading...
HomeMy WebLinkAboutB17-0130_A1.2_1496783970.pdfUP F C B D A.1 A 1a 3a 2a 1 A6.2 1 A6.1 1 A6.3 309 SF BEDROOM 1 1 208 SF BEDROOM 2 2 125 SF BEDROOM 3 3 BEDROOM 4 4 110 SF BEDROOM 5 5 E X1 H G 1A 2A 3A 6A 5A 7A 8A 9A 10A 11A 12A S2a S1a X2 F.1 A3.3 6 A3.3 1 A3.4 1 5a 6a 184 SF DINING 2 6 98 SF KITCHEN 2 7 80 SF ENTRY 2 8 216 SF LIVING 9 44 SF BATH 3 10 44 SF BATH 4 11 W2-4 W2-4 W2-4 W2-4 W2-4 W2-4 W3-4 S3a X3 14A 3a 4a 1a 2a 4A 13A Common Circulation Adjacent Unit Adjacent Unit Adjacent Unit W2-4 W2-4 W2-6 W2-4 10' - 0" 15' - 0" 6' - 6 1/2" 6' - 7" 6' - 5" W1-1 4EX 2EX 5EX 6EX 7EX 3.00° W1-1 W1-1 W1-1 W3-4 W2-4 W2-4 W1-1 W1-1 W1-1 W1-1 15' - 0" 8' - 2 1/2" 10' - 4 1/2" 10' - 10 1/2" 11' - 4 1/2" 12' - 0 1/2" .3' - 0" 18' - 1 1/2" 1EX 15A 3EX W2-4 W2-4 4' - 0 1/2" 11' - 0 1/2" 12' - 9" 7' - 5" 6' - 1" .6' - 1" 7' - 4" 14EX 54 SF BATH 5 27 54 SF BATH 6 102 NEW WALLS EXISTING WALLS WALL LEGEND WALLS TO BE DEMOLISHED PLAN NORTH TRUE NORTH 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 LOT 15 BIGHORN SUBDIVISION 291 BRIDGE ST, UNIT R-1 VAIL, CO 81657 A1.2 2ND FLOOR PROPOSED PLAZA LODGE R-1 Project Number - 1547 04/20/17 PERMIT SET 1/4" = 1'-0" 1 2ND FLOOR PROPOSED PROPERTY LINE PROPERTY LINE PROPERTY LINE 1. PROTECT ALL EXISTING BUILDING COMPONENTS (WALLS, DOORS, WINDOWS, CEILINGS, ETC.) NOTED TO REMAIN DURING DEMOLITION & NEW CONSTRUCTION. 2. CONTRACTOR SHALL VERIFY ALL ROOF AREAS TO BE REMOVED ALONG WITH EXTERIOR WALLS AND PROVIDE SUPPORT AND SHORING AS REQUIRED. GENERAL NOTES 1. PROVIDE NEW SPIRAL STAIR TO CONNECT 2ND FLOOR & 3RD FLOOR. RE: STRUCT DWGS FOR FLOOR FRAMING. 2. PROVIDE NEW KITCHEN CABINETS AND APPLIANCES. 3. PROVIDE NEW BATHROOMS WITH NEW FIXTURES AND PLUMBING. RE: MECH / PLMBG. DWGS. 4. PROVIDE NEW SLIDING GLASS DOOR ASSEMBLIES WITH MINIMUM U-VALUE OF 0.30. RE: A9.1 WINDOW SCHEDULE. 5.PROVIDE NEW EXTERIOR DECK. 6. PROVIDE NEW LOW-HEIGHT WALLS AND/OR RAILINGS AT NEW BALCONY DECKS - TYPICAL. 7. PROVIDE NEW WINDOWS WITH MINIMUM U VALUE OF 0.30 - TYPICAL. RE: A9.1 WINDOW SCHEDULE. 8. PROVIDE NEW GAS FIREPLACE WITH DIRECT VENTING AND NEW FINISHES AT FIREPLACE. 9. EXISTING EXTERIOR WALLS TO REMAIN. PROVIDE NEW SIDING TO MATCH NEW CONSTRUCTION - TYPICAL. 10. REMOVE EXISTING EXTERIOR SIDING AT THIS WALL. PROVIDE NEW INTERIOR FINISHES AS REQUIRED. 11. PROVIDE FINISH AT CIRCULATION SIDE OF WALL TO MATCH EXISITNG ADJACENT FINISHES. 12. PATCH & REPAIR DECK AT AREA OF DECK REMOVAL. MATCH EXISTING ADJACENT CONSTRUCTION. 13. EXISTING DECK TO REMAIN UNCHANGED. 14. PROVIDE BALCONY DECK DRAINS. FIELD VERIFY EXACT LOCATION AND NUMBER. ALL DRAINS SHALL BE CONNECTED DIRECTLY TO STORM SEWER. KEY NOTES 1 2 7 8 3 3 3 4 4 9 4 7 7 9 7 5 6 6 10 11 12 14 14 13 14 9 06/06/17