Loading...
HomeMy WebLinkAboutB17-0385_Download File_1510688093.pdfPage 1 of 4 9/26/2017 Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: Liles Residence 2440 Chamonix Lane Vail, CO 81657 All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F System Layout: Single Panel = 5.48ft tall X 3.26ft wide Panel Arrangement: see layout below; all in the portrait position, mounted flush to the south facing roof Meter is located the east side of the garage. PV production meter to be located adjacent to the HCE meter. Inverter to be located in the garage. Net Meter, Production Meter 11/14/17 Page 2 of 4 9/26/2017 Calculations 11.4kW System Size (STC)  38 Hanwha Q.PEAK-G4.1 300 solar modules @ 300watts  38 SolarEdge P320 Optimizers  1 SolarEdge SE10000A-US inverter (3 strings of 13/13/12 modules/optimizers per inverter)  Mounting Equipment: Unirac with S5! clamps  Monitoring: SolarEdge Remote Energy Monitoring System  Fixed array tilt angle: 9.46°  Array azimuth: 155º (where 180º is south)  Estimated annual power production: 16,359kWh Maximum PV System Voltage: 690.7 Voc = 39.76V/module 39.76V x 1 module = 39.76V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.28%/°C (-65C° x (-.0028C°)) = .182% ((.182% x 39.76V) x 1 panels) + 39.76V = 47V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.77A 9.77A x 1.25 = 12.2A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) SE10000A-US inverter limit 30.5A combined string Inverter Output Circuit Current: 690.8 (A)(3) 42A @ 240V 11/14/17 Page 3 of 4 9/26/2017 Conductor Sizing Pass Thru Box from Optimizers to Inverter (combined strings per inverter): SE10000A-US inverter limit 30.5A combined string 30.5A x 1.25 = 38.1A #8 THWN-2 Table 310.16 55A (90ºC column) No Conduit fill adjustment Table 310.15 (B)(3)(a) No temperature correction factor Table 310.15 (B)(2)(b) Inverter to PV Production Meter and Service Panel: Nameplate maximum continuous output current: 425A @ 240V 42A x 125% = 52.5A 210.19 (A)(1) #8 THWN-2 Table 310.16 55A (75ºC column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 60A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop 11/14/17 Page 4 of 4 9/26/2017 11/14/17 Q.PEAK-G4.1 295-305 1 APT test conditions: Cells at -1500 V against grounded, with conductive me- tal foil covered module surface, 25 °C, 168 h 2 See data sheet on rear for further information. Q.ANTUM ULTRA SOLAR MODULE ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.Q™) YIELD SECURITY 174 modules tested Best polycrystalline solar module 2014 Q.PRO-G2 235 MOD:27898 photon.info/laboratory    Quality Tested ID. 40032587 high reliability low degradation frequent product surveillance The new high-performance module Q.PEAK-G4.1 is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM Ultra. The world-record cell design was developed to achieve the best perfor- mance under real conditions – even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an effi ciency rate of up to 18.6 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti-PID Technology1, Hot-Spot-Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certifi ed for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC. MAXIMUM COST REDUCTIONS Up to 10 % lower logistics costs due to higher module capacity per box. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings 11/14/17 UL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class A Specifications subject to technical changes © Hanwha Q CELLS Q.PEAK-G4.1_270-280_2016-07_Rev02_NA At least 97 % of nominal power during first year. Thereafter max. 0.6 % degradation per year. At least 92 % of nominal power up to 10 years. At least 83 % of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2). Hanwha Q CELLS America Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE IRRADIANCE [W/m²]RELATIVE EFFICIENCY [%] 200 400 600 800 1000 110 100 90 80 Irradiance [W/m²] Relative efficiency [%]Format 65.7 in × 39.4 in × 1.26 in (including frame) (1670 mm × 1000 mm × 32 mm) Weight 41.45 lb (18.8 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminum Cell 6 × 10 monocrystalline Q.ANTUM solar cells Junction box 2.60-3.03 in × 4.37-3.54 in × 0.59-0.75 in (66-77 mm × 111-90 mm × 15-19 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (-) ≥ 39.37 in (1000 mm) Connector Multi-Contact MC4 or MC4 intermateable, IP68 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS [V] 1000 (IEC) / 1000 (UL) Safety Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating C (IEC) / TYPE 1 (UL) Design load, push (UL)2 [lbs/ft2] 75 (3600 Pa) Permitted module temperature on continuous duty − 40 °F up to +185 °F (− 40 °C up to +85 °C) Design load, pull (UL)2 [lbs/ft2] 55.6 (2666 Pa)2 see installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Number of Modules per Pallet 32 Number of Pallets per 53' Container 32 Number of Pallets per 40' Container 26 Pallet Dimensions ( L × W × H ) 68.7 in × 45.3 in × 46.1 in (1745 × 1150 × 1170 mm) Pallet Weight 1435 lbs (651 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 15 5 2520 0 10 YEARS 97 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) DETAIL A 0.630" (16 mm) 0.335" (8.5 mm)0.965" (24.5 mm) Junction bo× Product label 38.58" (980 mm)65.7" (1670 mm) 4 × Fastening points (DETAIL A) Cable withconnectors Frame 5.90" (150mm) 39.4" (1000 mm) 37.44" (951 mm) 1.26" (32 mm) 8 × Drainage holes 6 × Grounding points ø 0.177" (4.5 mm) 39.37" (1000 mm) 13.6“(345 mm) ELECTRICAL CHARACTERISTICS POWER CLASS 295 300 305 MINIMUM PERFORMANCE AT STANDARD TESTING CONDITIONS, STC1 (POWER TOLERANCE +5 W / -0 W) MinimumPower at MPP2 PMPP [W] 295 300 305 Short Circuit Current* ISC [A] 9.70 9.77 9.84 Open Circuit Voltage* VOC [V] 39.48 39.76 40.05 Current at MPP* IMPP [A] 9.17 9.26 9.35 Voltage at MPP* VMPP [V] 32.19 32.41 32.62 Efficiency2 η [%] ≥ 17.7 ≥ 18.0 ≥ 18.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3 MinimumPower at MPP2 PMPP [W] 218.1 221.8 225.5 Short Circuit Current* ISC [A] 7.82 7.88 7.94 Open Circuit Voltage* VOC [V] 36.92 37.19 37.46 Current at MPP* IMPP [A] 7.20 7.27 7.35 Voltage at MPP* VMPP [V] 30.30 30.49 30.67 11000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 %3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ CertifiedUL 1703 (254141) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC α [% / K] + 0.04 Temperature Coefficient of VOC β [% / K] − 0.28 Temperature Coefficient of PMPP γ [% / K] − 0.39 Normal Operating Cell Temperature NOCT [°F] 113 ± 5.4 (45 ± 3 °C) 11/14/17 www.solaredge.us    Up to 25% more energy PV power optimization at the module-level 11/14/17    P300 (for 60-cell modules) P320 (for high-power 60-cell modules) P400 (for 72 & 96-cell modules) P405 modules) INPUT Rated Input DC Power 400 405 W Absolute Maximum Input Voltage 48 80 Maximum DC Input Current % % II Maximum Output Current Maximum Output Voltage 85 EMC RoHS Yes Maximum Allowed System Voltage %    8 25 25 50 Maximum Power per String 5250 W Yes 11/14/17 11/14/17 11/14/17