Loading...
HomeMy WebLinkAboutDRB16-0421_A111_1478908291 (2).pdfDN DN UP DN 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 G G H H D D E E C C B-1 B-1 B B A A RR QQ PP NN I I F F K K BB AA CC DD EE HH GG FF JJ KK LL MM NEW EXPOSED AGGREGATE POOL DECK WITH SNOWMELT 9'-0" 20'-0" 20'-0" 20'-0" 23'-0" 23'-0" 23'-0" 23'-0" 22'-9" 25'-7" 26'-8" 5'-0" 12'-0" 16'-0" 25'-6" 25'-6" 19'-7" 12'-8 3/4" 14'-10 1/4" 17'-0" 174'-10" 44'-7" 23'-0" 23'-0" 12'-0"5'-0" 14'-10 1/4"12'-8 3/4" 13'-0" 23'-0" A404 1 A405 1 A407 1 A401 1 A410 1 32'-7 1/4" 32'-8 1/4" RAMP DOWN RAMP DOWN UUU XXX ZZZ NEW ENTRY ROOF AND VESTIBULE NEW 90DEG HOLD OPEN DOORS FOR STAIRWELL TO LOBBY REMOVE WINDOWS IN STAIR TOWER; FRAME OPENING AND FINISH W/ TWO LAYERS GYP. INTERIOR AND PLYWOOD WITH WATER RESISTANT MEMBRANE EXTERIOR REMOVE WINDOWS IN STAIR TOWER; FRAME OPENING AND FINISH W/ TWO LAYERS GYP. INTERIOR AND PLYWOOD WITH WATER RESISTANT MEMBRANE EXTERIOR UNIT 111 UNIT 105 UNIT 113LL UNIT 109LL UNIT 107LL UNIT 103LL UNIT 101 UNIT 102 UNIT 104 UNIT 106 UNIT 115 REPLACE/REFURBISH BUILDING UTIILITY DOORS WITH IN-KIND HARDWARE AND RATING (TYP. FOR "BUILDING STANDARD UTILITY DOORS BUILDING STANDARD UTILITY DOOR BUILDING STANDARD UTILITY DOOR BUILDING STANDARD UTILITY DOORS BUILDING STANDARD UTILITY DOOR BUILDING STANDARD UTILITY DOOR CARPET CARPET STAIR 02 STAIR 05 STAIR 06 STAIR 09 STAIR 10 STAIR 01 WD-02 UNIT ABOVE 321 SD-02 SD-01 WD-03 SD-06 HM-01 WD-07 HM-04 HM-05 HM-03 SD-03 GD-01 GD-02 SD-04 SG-01 GD-03 HM-10 GD-04 HM-07 HM-06 HM-08 HM-02 HM-09 PG-01 BUILDING STANDARD UTILITY DOOR STAIR 07 WD-01 CW-09 ALL EXISTING FEATURES OF THE CURRENT LOCKERS ROOMS TO BE DEMOLISHED AV-8001AS-900 1 1004 1002 1008 1012 1011 1005 1006 1009 1010 1007 AF-902 1 CARPET (PRICE 1) MOHAWK GROUP-NEW VINTAGE; REAWAKENED, COLOR TBD HERRINGBONE INSTAL. AREA =106 S.F. (CARPET PRICE 1) MOHAWK GROUP-NEW VINTAGE; REAWAKENED,COLOR TBD HALF-LAP INSTAL. AREA =225 S.F. TILE (RA) HARDROCK-SAND; 2X24, 4X24, & 6X32; INSTALL AS DRAWN AREA=133 S.F. CARPET (RA) MOHAWK GROUP-NEW VINTAGE; REAWAKENED, COLOR TBD HALF-LAP INSTAL. AREA=540 S.F. TILE (RA) *REF. ENLARGED PLAN ON A-404 AND A-405 AREA =536 S.F. PEBBLE FLOOR (RA); GREY BLEND AREA=1,350 S.F. CARPET (PRICE 1) MOHAWK GROUP-NEW VINTAGE; REAWAKENED, COLOR TBD HALF-LAP INSTAL. AREA =210 S.F. TILE (RA) HARDROCK-SAND; 2X24, 4X24, & 6X32; INSTALL AS DRAWN AREA =1,172 S.F. AE-802 1 Scale Date Drawn By Checked By Project Number 1/16" = 1'-0" 7/14/2016 9:17:59 AM A111 LEVEL 1 FINISH PLAN / DOORS / COMMON SPACE WINDOWS VAIL SPA CONDOMINIUMS MEW MEW 02/19/2016 VSRP - 2016 710 W. LIONSHEAD CIRCLE 1/16" = 1'-0" 1 LEVEL 1 FINISH PLAN - GMP G.C. SCOPE GENERAL PLAN NOTES 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. 2. FURNITURE IS NIC, U.N.O. 3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES AND GARAGE AND OTHER UNCONDITIONED AREAS. 4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13. 5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL BE COORDINATED WITH STRUCTURAL. 7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE AND LOCATION. 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT PERPENDICULAR WALL SHALL BE 4" U.N.O. 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES & GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. BARRIER ON EXT. WHERE SIDING SHOWN). 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04. 11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON PLANS 12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY CONSTRUCTED TO MATCH EXISTING, U.N.O 13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM NOTED FROM FACE OF FINISH TO FACE OF FINISH. 14. (NOTE DELETED -NO NEW STEEL BEARING COLUMNS BEING ADDED) 15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR RATE OR MATCH EXISTING 16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR TRANSITIONS 17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBL 20. ALL EXISTING GLU-LAMS ARE CONSIDERED NON-STRUCUTRAL AND SHALL BE WRAPPED WITH WEATHER RESISTIVE BARRIER AND BE CLAD WITH COPPER 21. ALL STOREFRONT AND SLOPED GLAZING TO HAVE .28 U-VALUE 22. ALL NEW RESIDENTIAL DOORS AND WINDOWS TO HAVE .30 U-VALUE 23. SPECIAL INSPECTIONS SHALL INCLUDE SITE-WELDED STEEL AT ROOF CAPS, AND REBAR REINFORMENT AT POOL AREA CONCRETE WORK No. Description Date 1 PROGRESS/PRICIN G 2 OCT 15 2 DRB REVIEW 12 OCT 15 3 PROGRESS/PRICIN G 2 23 DEC 15 4 CDs/PERMIT 21 JAN 16 5 CDs/PERMIT 2 19 FEB 16 6 TILE/CARPET SKETCH 16 JUNE 16 COMMON WINDOW LOCATIONS NOTED ON PLAN - SEE WINDOW PROVIDERS PACKAGE FOR MORE INFORMATION SEE A603 FOR PG-01 INFORMATION GMP FINISHES: -CARPET AS CALLED OUT -TILE AS CALLED OUT -TRIM GLAZED -REMOVE CROWN/REPAIR ADJACENT WALL/CEILING AREAS -WALLS PAINTED -DOORS REFINISHED AS DETERMINED BY OWNER DRB APPROVED 10/27/2016 12:00:00 AM