HomeMy WebLinkAboutDRB16-0421_A112_1478908294 (2).pdfDN
DN
1
2
3
5
6
7 7
8
9
10
11
12
13
14
15
16 17
G
G
H
H
D
D
E
E
C
C
B-1
B-1
B
B
A
A
RR
QQ
PP
NN
I
I
F
F
K
K
BB
AA
CC
DD
EE
HH
GG
FF
JJ
KK
5'-11"
NEW SECOND LEVEL ADA
BATHROOMS, SEE ENLARGED
PLANS, A408
A408
1
UUU
NEW ENTRY DOORS
BETWEEN GUEST GARAGE
AND LEVEL 2 LOUNGE; MIN
RATING 90 MIN.
ZZZ
NEW WALL, OPERABLE
WINDOWS, SLOPED GLAZING,
AND STOREFRONT SYSTEM
UNIT
201
UNIT
307LL
UNIT
203
UNIT
103UL
UNIT
107UL
UNIT
109UL
UNIT
109UL
UNIT
321LL
UNIT
202
UNIT
204
UNIT
206
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
BUILDING STANDARD
UTILITY DOOR
EXISTING OFFICE,
HOUSEKEEPING, AND
MECHANICAL SPACES TO
REMAIN
EXISTING LEVEL TWO (GUEST GARAGE) PARKING
REPLACE TRAFFIC COATING ON EXTERIOR
LANDINGS; REPAIR/REPAINT RAILINGS; COVER
GLULAM WITH COPPER AND COUNTER FLASH
UNDER TRAFFIC COATING
STAIR
02
STAIR
05
STAIR
06
STAIR
10
STAIR
09
STAIR
1
REPLACE TRAFFIC COATING
AND COMPOSITE DECKING ON
COVERED TERRACE
WD-04
WD-05
HM-12
BUILDING
STANDARD
UTILITY DOOR
BUILDING
STANDARD
UTILITY DOOR
HM-15
HM-14
HM-13
SD-05
HM-16
HM-17
HM-18 HM-21 WD-08
HM-20
HM-19
FUTURE MECH
21
CW-10
CW-07
CW-08
NEW STOREFRONT GLAZING
SYSTEM
ALL EXISTING FEATURES OF THE
CURRENT RESTROOMS TO BE
DEMOLISHED
STAIR
07
REFINISH
EXTERIOR OF
STAIR-07 WITH
ELASTOMERIC
PAINT
AV-801
1
AS-901
1
1016
1015
1017
1014
1018
AF-903
1
TILE (RA)
HARDROCK-SAND;
2X24, 4X24, & 6X32;
INSTALL AS DRAWN
AREA=140 S.F.
TILE (RA)
HARDROCK-SAND;
2X24, 4X24, & 6X32;
INSTALL AS DRAWN
AREA=56 S.F.
CARPET (PRICE 1)
MOHAWK GROUP-NEW VINTAGE;
REAWAKENED,COLOR TBD
HALF-LAP INSTAL.
AREA=3,560 S.F.
TILE (RA)
REFER TO ENLARGED PLAN
ON A-408
AREA =255 S.F.
AE-803
1
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
7/14/2016
9:18:06 AM
A112
LEVEL 2 FINISH
PLAN / DOORS /
COMMON SPACE
WINDOWS
VAIL
SPA
CONDOMINIUMS
MEW
MEW
02/19/2016
VSRP - 2016
710 W. LIONSHEAD
CIRCLE
1/16" = 1'-0"
1
LEVEL 2 FINISH PLAN -GMP G.C. SCOPE
No. Description Date
1 PROGRESS/PRICIN G 2 OCT
15
2 DRB REVIEW 12 OCT
15
3 PROGRESS/PRICIN G 2 23 DEC
15
4 CDs/PERMIT 21 JAN
16
5 CDs/PERMIT 2 19 FEB
16
6 TILE/CARPET SKETCH 16
JUNE
16
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS ARE FULLY SPRINKLERED PER NFPA-13.
SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVELS ARE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF EXISTING KNOX BOXES WITH FIRE
DEPT- 1 EXISTING BOXES ARE AT FDC LOCATIONS
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP AIR CONDITIONING UNITS UNITS
SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR
SIZE AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. ALL BUILDING UTILITY DOORS SHALL BE EITHER REPLACED
IN-KIND W/ REGARD TO RATINGS, HARDWARE, AND FINISHES, OR
KEPT AS-IS. DETERMINED CASE BY CASE - SEE LOCATIONS ON
PLANS
12. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICALLY
CONSTRUCTED TO MATCH EXISTING, U.N.O
13. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
14. (NOTE DELETED -NO NEW STEEL BEARING COLUMNS BEING
ADDED)
15. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATE OR MATCH EXISTING
16. REFER TO DETAILS FOR SPECIFIC OR PROPOSED FLOOR
TRANSITIONS
17. 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR
LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT
BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN
AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED
BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN.
CLEAR HEIGHT
18. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
19. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBL
20. ALL EXISTING GLU-LAMS ARE CONSIDERED NON-STRUCUTRAL
AND SHALL BE WRAPPED WITH WEATHER RESISTIVE BARRIER
AND BE CLAD WITH COPPER
21. ALL STOREFRONT AND SLOPED GLAZING TO HAVE .28 U-VALUE
22. ALL NEW RESIDENTIAL DOORS AND WINDOWS TO HAVE .30
U-VALUE
23. SPECIAL INSPECTIONS SHALL INCLUDE SITE-WELDED STEEL AT
ROOF CAPS, AND REBAR REINFORMENT AT POOL AREA
CONCRETE WORK
COMMON WINDOW LOCATIONS NOTED ON PLAN - SEE WINDOW PROVIDERS PACKAGE FOR MORE INFORMATION
SEE A603 FOR PG-01 INFORMATION
GMP FINISHES:
-CARPET AS CALLED OUT
-TILE AS CALLED OUT
-TRIM GLAZED
-REMOVE CROWN/REPAIR ADJACENT WALL/CEILING AREAS
-WALLS PAINTED
-DOORS REFINISHED AS DETERMINED BY OWNER
DRB
APPROVED
10/27/2016
12:00:00 AM