Loading...
HomeMy WebLinkAboutDRB16-0436_A1.01_1478904411.pdf EXTERIOR INTERIOR \ • __2/ I TOV STAMP PI; j6 11. fl._ 4 I7.1 il EXIST CEMENTITIOUS STUCCO 0 - ' N 1- c, W ..., DRB u z O ' APPROVED l •r R. - ' .i / 9/27/2016 `•+.' CONTINUOUS VAPOR RETARDER, .� 12:00:00 AM ...:..1. : ,. . + WRAP AND SEAL TO OPENING w EXISTING 2X 12 HEADER --- / r11 ,.. : EXTERIOR SHEATHING, EXISTING ; . � .;, PA1.01 WEATHER BARRIER, LAP OVER v� Is�': • -•::�n,., rW‘ 911Krar-"ilk 4t 1141- inW ,. MATCH EXIST MTL FLAHSING � V r - / EXISTING WINDOW Z � ;fir;+, � �' *Dip _ . 1H , ��'� REPAIR STUCCO AS i HEADER :6_ N '" ,, ^� _ NECESSARY TO MATCH ITZ O ►, '' . .� �,,.'x •. 1 \ EXISTING O . a�0 4 y��� , MATCH SIZE, COLOR t/) + 3 + .1r;. : • ....... �.....a..1 ✓ H AND PANELING OF w 8 ' W 0 1n O _'!�`'' EXISTING WINDOW z SLOPE Z ' �' ti+`" X SELF ADHERED FLASHING OVER ~ Z „.'■ • lag w . fr W NAIL FIN AND UNDER WEATHER ��(II Z O •K' e.. _ E co • .�.'�� o BARRIER, EXTEND UP 6" MIN, REF H IiuII�' V LU7 .- i + MI It- - Q 2 DETAIL 6/A1.01 XLu a = ;� A1.01 MTL FLASHING W/ DRIP, _ I (/) 62 Ce U o • - - . PAINT TO MATCH EXIST TRIM 0 I � j W O E 0 J X /^\ /^\ INSULATED SHIM SPACE 2 I iV Q * -2 en . J 1bil M r. Iii, U / \ / \ \ �f� 'd�5�''!Je''eT�e�crrr�u.Yr.���,�xpddpp�S� _� = 0 W Q 0� • / \ / \ x 7 �- �_ / \ / \ 2X WD TRIM MATCH oC Z O O V b ` - \ EXISTING, VIF Q Q ti) Z Lu ' 44 MATCH EXIST 1, o N i' 1 SEALANT G 1.0 to t I - M O -`"*�''..r�: : ' " "'`' ‘. A1.01 INTERIOR TRIM TO <. --z- �_: ""' 'OA MATCH EXISTING 7 = —8cy, C' .. es.?"moi.�'�r,. .- i [.� � .- N O Ql MATCH EXISTING WINDOW, RED LINES REPRESENT NEW REF 5/A1.01 > 3 O^ CONTROL JOINTS FOR 73e 81 col 5 EXISTING WINDOW STUCCO PATCH 4 WINDOW ELEVATION 1 ° U A1.01 1/2"=1'-0" 3 WINDOW HEAD DETAIL A1.01 NOT TO SCALE L ^N CD N Ln A1.01 3"=1'-0" N iv p EXTERIOR INTERIOR cn m° STAPLE TOP OF 12" PIECE OF SHEATHING PAPER ACROSS SILL, PERMANENTLY FASTEN NAILING FINS TO WALL FRAMING _ : ........ o J STEP STEP 5: EXIST CEMENTITIOUS STUCCO, I �--� V a EXTENDING 6" MIN HORIZ PAST ROUGH OPNG EA SIDE. (LET MATCH EXISTING BOTTOM HANG LOOSE) STEP 6: COVER NAILING FINS AT JAMBS W/6"WIDE SELF ADHERING b MODIFIED BITUMINOUS SHEET MEMBRANE WATERPROOFING CONTINUOUS VAPOR RETARDER, \- STEP 2: INSTALL PIECE OF SELF ADHERING MODIFIED BITUMINOUS SHEET WRAP AND SEAL TO OPENING :------------------ MEMBRANE WATERPROOFING ACROSS SILL, EXTENDING 6" MIN COVER NAILING FIN AT HEAD W/6"WIDE SELF ADHERING W Ii D Q HORIZ PAST ROUGH OPNG EA SIDE &6" MIN VERT ABOVE SILL AT STEP 7: MODIFIED BITUMINOUS SHEET MEMBRANE WATERPROOFING O :.; , V N JAMBS. WEATHER BARRIER, LAP OVER /1,1 6" NAILING FIN AND STEP 3. INSTALL ADDITIONAL PIECE OF SELF ADHERING MODIFIED /6" SELF-ADHERED FLASHING : BITUMINOUS SHEET MEMBRANE WATERPROOFING AT CORNERS SELF-ADHERING OF SILL MODIFIED BITUMINOUS 6" � �� REPAIR STUCCO AS SEAL ^� SHEET MEMBRANE /'i , NECESSARY TO MATCH ROUGH OPENING WATERPROOFING ' �� EXISTING 1 / li O . CONT BEAD OF SELF ADHERED FLASHING \ . 1i SEALANT AT HEAD13Y �'+ - 11 AND JAMBS UNDER OVER NAIL FIN AND UNDER O ( WEATHER BARRIER, � v '�' �-° � '� NAILING FINS OF w WINDOW) REF DETAIL 6/A1.01 z / �w? SELF ADHERING } + � MODIFIED SEALANT H BITUMINOUS SHEET u - , I " "" v' WATERPROOFING 6" 2X WOOD TRIM, MATCH EXIST w SHEATHING PAPER �: INSULATED SHIM SPACE 11 6" IPIQ STARTER STRIP 12"+ 2 LA STEP 8: INSTALL L-SHAPED METAL FLASHING W/ DRIP OVER WINDOW HEAD �1 see KUM W COLORED SEALANT& • - — — c.: STEP 9: INSTALL SHEATHING PAPER SHINGLE STYLE OVER WALL BACKER ROD, MATCH EXISTING 0 _— I rr i SHEATHING gp u U STEP 4: APPLY CONT BEAD OF SEALANT AT EXTERIOR SIDE OF HEAD & SEALANT Zi O o JAMBS. INSTALL WINDOW FROM INTERIOR . WINDOW TO HAVE COLLAPSIBLE NAILING FIN. MAKE SURE FIN IS TIGHT TO EXTERIOR INTERIOR TRIM, Q SHEATHING. TEMPORARILY FASTEN THRU JAMBS ONLY (NOT MATCH EXIST W J THRU SILL) // / ' MATCH EXISTING WINDOW, W O REF 5/A1.01 \/ Ce O N TEMPORARY !I[_1101111 LAP SHEATHING WINDOW JAMB DETAIL J J N FASTENERS PAPER OVER METAL A1.01 3"=1'-0" FLASHING ' \ > t EXTERIOR INTERIOR W O •4 l 'L ' I TUCK BOTTOM OF / O U SHEATHING PAPER UNDER STARTER � ' _ STRIP (SEE STEP 1) � // MATCH EXISTING WINDOW , REF 5/A1.01 - - I NTERIOR TRIM, MATCH EXIST i J ISSUED FOR: 1/40 SEALANT INSULATED SHIM SPACE No. DATE COMMENT % A 09/15/16 DRB EXTERIOR WALL & WATERPROOFING NOTES COLORED SEALANT& ' ��� • BACKER ROD, MATCH EXIST SLOPE -r-t- 1. FOR TYPICAL WALL CONTRUCTION SEE EXTERIOR WALL ASSEMBLES. MATERIALS LISTED ON THESE DETAILS SUPERCEDE MATERIAL CALL-OUTS PERTAINING TO TYPICAL CONDITIONS EVEN WHEN NOT KEYED. MTL FLASHING SET IN 2. WATERPROOFING & FLASHING DETAILS SHOWN ON THIS SHEET ARE TYPICAL FOR THIS PROJECT, AND ARE TO APPLY TO TYPICAL CONDITIONS EVEN WHEN CONT SEALANT I NOT KEYED. 2X WOOD TRIM, MATCH EXIST 3. TYPICALLY, ANY SHEET COMPONENT OF THE BUILDING WATERPROOFING SYSTEM (ROOFING, FLASHING, SHEATHING PAPER, BELOW GRADE WATERPROOF M \ EMBRANE, ETC) SHALL TUCK UP UNDERNEATH THE WATERPROOFING SHEET COMPONENT ABOVE AND OVERLAP THE WATERPROOFING SHEET COMPONENT MTL FLASHING UNDER NAIL FIN, BELOW WITH A 3" MIN LAP WRAP OPENING I' DOOR & WINDOW ( I I. 4. EXTERIOR DOOR, WINDOW, & LOUVER ROUGH OPNGS SHALL BE FLASHED WITH SELF ADHESIVE WATERPROOFING MEMBRANE PER DETAIL 1, THIS SHEET v �/ I. ... SEALANT SCHEDULES 0 � I 5. METAL FLASHING, WHERE EXPOSED TO PUBLIC VIEW, SHALL BE PREFINISHED, GALVANIZED METAL FLASHING, OR COPPER AS CALLED FOR, AT ALL < S ''4 AND DETAILS TRANSITIONS INCLUDING BUT NOT LIMITED TO: ROOF TO WALL, WALL TO BALCONY CAP, WALL TO WALL, ROOF TO ROOF. w 0 REPAIR STUCCO AS FLEXIBLE FLASHING, WRAP U •.; p OPENING, EXTEND 12" BELOW I-- .'* NECESSARY TO MATCH SILL, REF DETAIL 6/A1.01EXISTING i PROJECT No. DATE z : 20162476 09/15/16 WEATHER BARRIER, DRAWN BY CHK BY TRV BY 6 WINDOW FLASHING DETAILS WRAP OPENING ; JBR TL A1.01 NOT TO SCALE CONTINUOUS VAPOR RETARDER SHEET No. WRAP AND SEAL TO OPENING : '� o A1 . 01 SCALE: AS SHOWN 1 WINDOW SILL DETAIL A1.01 3"=1'-0"