Loading...
HomeMy WebLinkAboutB16-0401_MEP-3_1483121133.pdf100/3 200/3 100/3 100/3 200/3 600/3 600/3 1200/3 M GF 100/3 200/3 200/3 T T (E) PANEL "HP2" (E) MDC - 480Y/277V, 3Ø, 4W, 1200A, T (E) PANEL "MC" 60/3 L E N (E) PANEL "EM" (E) PANEL "LL" (E) PANEL "HL" (E) 30 KVA TRANSFORMER T (E) PANEL "LP5" (E) PANEL "LP4" (E) 225 KVA TRANSFORMER (E) 112.5 KVA TRANSFORMER (E) 75 KVA TRANSFORMER (E) PANEL "LP2B" (E) PANEL "LP2-2A" (E) PANEL "LP2" (E) PANEL "LP2A" (E) PANEL "#1" T (E) PANEL "LP3" (E) PANEL "HP3" (E) 15 KVA TRANSFORMER T (N) PANEL "LP4" (N) 30 KVA TRANSFORMER 100/3 CHILLER ELEVATOR SPARE PANEL HP1 SPARE CHILLER CIRCULATION PUMPS POWER FEED FROM STANDBY GENERATOR NOT VERIFIED. (E) MANUAL TRANSFER SWITCH. INTERMEDIATE PARKING LEVEL UPPER PARKING LEVEL LOWER PARKING LEVEL (E) MAIN ELECTRICAL ROOM (E) MECHANICAL ROOM PROPOSED PARKING LEVEL ELECTRICAL SERVICE TO BUILDING. SCALE: NONE SINGLE LINE POWER DIAGRAM 1 (E) PANEL: HP2 FED FROM: VOLTAGE: 480Y/277V, 3 PHASE, 4 WIRE LOCATION: MECHANICAL ROOM BUS AMPACITY: 600A MOUNTING: SURFACE MAIN: ENCLOSURE: NEMA 3 AIC: CKT DESCRIPTION NOTES LOAD BREAKER PHASE BREAKER LOAD DESCRIPTION NOTES CKT NO VA TYPE POLE AMPS AMPS POLE TYPE VA NO 1 UNIT HEATER ABOVE 3 20 A 40 3 STEAMER MEN'S LOCKER RM. 2 3 B 4 5 C 6 7 CASCADE CAMP 1 20 A 20 1 PING PONG 8 9 RACQUETBALL COURT LIGHTS 1 20 B 20 1 SQUASH 10 11 SPINNING 1 20 C 20 1 PILATES 12 13 BASKETBALL COURT LIGHTS 1 20 A 30 3 HVAC E LEVEL SOUTH MECH. 14 15 BASKETBALL COURT LIGHTS 1 20 B 16 17 BASKETBALL COURT LIGHTS 1 20 C 18 19 HVAC D LEVEL MECH. RM. UNIT TO THE RIGHT 3 30 A 30 3 HVAC E LEVEL NORTH MECH. 20 21 B 22 23 C 24 25 HVAC D LEVEL MECH. RM. 3 30 A 30 3 SPARE 26 27 B 28 29 C 30 31 STEAMER WOMEN'S LOCKER RM. 3 40 A 40 3 SUB-PANEL LR - MEN'S SPA 32 33 B 34 35 C 36 37 SUB-PANEL LP4 - PARKING EXHAUST AND SUPPLY FANS 3 50 A 150 3 MAIN FOR PANEL HP3 TENNIS COURTS 38 39 B 40 41 C 42 LOAD TYPES CONNECTED LOAD (VA) SUBFEED PANEL DEMAND LOAD (VA) GENERAL NOTES: A B C TOTAL TOTAL FACTOR TOTAL A. LIGHTING 0 0 0 0 0 125% 0 B. RECEPTACLES 0 0 0 0 0 #DIV/0! (NEC 220) 0 SPECIFIC NOTES: MOTORS 0 0 0 0 0 100% 0 1. OWNER AND/OR CONTRACTOR LARGEST MOTOR 0 0 0 0 0 125% 0 SELECTED EQUIPMENT. FOR EQUIPMENT 0 0 0 0 0 100% 0 INFORMATION ONLY. COORIDATE APPLIANCES 0 0 0 0 0 0 0 ELECTRICAL REQUIREMENTS WITH TOTAL DEMAND LOAD (KVA) = 0.0 SYSTEM DESIGNER PRIOR TO ROUGH-IN. TOTAL DEMAND LOAD (A) = 0 2. (N) PANEL: LP4 FED FROM: HP2 VOLTAGE: 208Y/120V, 3 PHASE, 4 WIRE LOCATION: NORTHWST OF PARKING LEVEL BUS AMPACITY: 100A MOUNTING: SURFACE MAIN: M.L.O. ENCLOSURE: NEMA 3 AIC: CKT DESCRIPTION NOTES LOAD BREAKER PHASE BREAKER LOAD DESCRIPTION NOTES CKT NO VA TYPE POLE AMPS AMPS POLE TYPE VA NO 1 EF-1 3 20 A 20 3 SF-1 2 3 1490 B 1490 4 5 C 6 7 EF-2 3 20 A 20 3 SF-2 8 9 1490 B 1490 10 11 C 12 13 EF-3 3 20 A 20 3 ` SF-3 14 15 1490 B 1490 16 17 C 18 19 DRY SYSTEM COMPRESSOR 1 20 A 20 1 CO/NO2 CONTROL PANEL 20 21 POWER @ ROOF 1 20 B 20 1 SPARE 22 23 SPARE 1 20 C 20 1 SPARE 24 25 SPARE 1 20 A 20 1 SPACE 26 27 SPACE B 1 SPACE 28 29 SPACE C 1 SPACE 30 31 SPACE A 1 SPACE 32 33 SPACE B 1 SPACE 34 35 SPACE C 1 SPACE 36 37 SPACE A 1 SPACE 38 39 SPACE B 1 SPACE 40 41 SPACE C 1 SPACE 42 LOAD TYPES CONNECTED LOAD (VA) SUBFEED 'GH1L' PANEL DEMAND LOAD (VA) GENERAL NOTES: A B C TOTAL TOTAL FACTOR TOTAL A. LIGHTING 0 0 0 0 0 125% 0 B. RECEPTACLES 0 0 0 0 0 #DIV/0! (NEC 220) 0 SPECIFIC NOTES: MOTORS 0 0 0 0 0 100% 0 1. OWNER AND/OR CONTRACTOR LARGEST MOTOR 0 0 0 0 0 125% 0 SELECTED EQUIPMENT. FOR EQUIPMENT 0 0 0 0 0 100% 0 INFORMATION ONLY. COORIDATE APPLIANCES 0 0 0 0 0 0 0 ELECTRICAL REQUIREMENTS WITH TOTAL DEMAND LOAD (KVA) = 0.0 SYSTEM DESIGNER PRIOR TO ROUGH-IN. TOTAL DEMAND LOAD (A) = 0 2. PROVIDE 4" CONCRETE SHOPKEEPING PAD BENEATH (N) TRANSFORMER. (N) NEMA1 DISCONNECT ADJACENT TRANSFORMER. (3)#8, #10G, 1"C M POINT OF TEMPORARY METERING REQ'D TO VERIFY RESERVE CAPACITY OF (E) PANEL 'HP2' TO SUPPORT. SEE SCOPE OVERVIEW NOTS SHEET MEP-1. INSTALL (N) BREAKER IN (E) 'HP2' TO SERVE (N) PARKING LEVEL. TRANSFORMER PRIMARY VOLTAGE - 480V DELTA XFMR KVA SECONDARY VOLTAGE - 120/208V WYE GROUNDING ELECTRODE CONDUCTOR FEEDER BREAKER WIRE SIZE CONDUIT SIZE FLA FLA CONDUIT SIZE WIRE SIZE MAIN BREAKER 50A/3P 3 #8, #10 G. 1" 36 30 83 2" 4 #2, #8 G. 100A/3P #8 LOAD FOR DRY SYSTEM COMPRESSOR IS AN ASSUMPTION AT THIS TIME. LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING LAMP WATTS VOLT MANUFACTURER CATALOG NUMBER NOTES QUANT. TYPE W3 WALL MOUNTED LED PARKING LOT FIXTURE WITH INTEGRAL PHOTOCELL AND TYPE 3 DISTRIBUTION WALL LED 209W 277V LITHONIA DSX1LED 60C 1000 4K T3M MVOLT PER DBLXD /DLL127F1.5JU S1 4' LED VAPOR TIGHT FIXTURE SURFACE LED 42W 277V LITHONIA VAP 4000LM FST WD MVOLT 40K 90CRI S1E 4' LED VAPOR TIGHT FIXTURE WITH INTEGRAL EMERGENCY BATTERY PACK SURFACE LED 62W 277V LITHONIA VAP 6000LM FST WD MVOLT 40K 90CRI /BSL722C GENERAL NOTES: A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. B. ALL FINISHES SHALL BE SELECTED BY THE OWNER/OPERATOR PRIOR TO PURCHASING FIXTURES. SPECIFIC NOTES: 1. EXTERIOR LIGHTS SHALL HAVE INTEGRAL PHOTOCELL TO ENSURE THEY DO NOT OPERATE DURING THE DAY AND BY EXTERNAL MOTION SENSOR TO ALLOW FOR AUTOMATIC OPERATION. 2. EXIT SIGN SHALL BE PROVIDED WITH INTEGRAL BATTERY AND WIRED USING UNSWITCHED LIGHTING BRANCH CIRCUIT CONDUCTOR TO ALLOW FOR CONTINUOUS OPERATION AND CHARGING. 3. EXIT SIGNS SHALL BE WALL MOUNTED TO FLUCH ELECTRICAL BOX, 6" ABOVE THE TOP OF THE DOOR FRAME. (303) 900-8782 PO Box 3699, Evergreen, CO 80437 STBENGR.COM INFO@STBENGR.COM 1295 WESTHAVEN DRIVE VAIL, CO 81657 12/30/16