HomeMy WebLinkAboutB16-0401_MEP-4_1483121135.pdfSYSTEM DESCRIPTION THE SYSTEM CONSISTS OF THREE EXHAUST FANS (EF-1, 2 & 3) AND THREE SUPPLY FANS (SF-1, 2 & 3) EQUIPPED WITH TWO SPEED MOTORS AND MOTOR OPERATED DAMPERS TO PROVIDE CODE REQUIRED VENTILATION PER 2015 IMC. EXHAUST FANS AND SUPPLY FANS SHALL BE CONTROLLED BY MACURCO DVP-120M ADDRESSABLE DETECTION AND VENTILATION CONTROL PANEL. WALL MOUNTED CARBON MONOXIDE (CO) AND NITROGEN DIOXIDE (NO2) SENSORS, MACURCO CM-6 AND TX-6-ND RESPECTIVELY, PROVIDE ELECTRONIC SIGNALS TO THE CONTROL PANEL FOR EXHAUST AND SUPPLY FAN STAGING AND CONTROL. OPERATION CONTINUOUS VENTILATION: THE LOW SPEED CONTACT FOR SHALL BE WIRED TO A WALL MOUNTED ON/ OFF WALL SWITCH ADJACENT TO CONTROL PANEL FOR MINIMUM CONTINUOUS OPERATION WHEN SPACE IS USED AS A PARKING STRUCTURE FOR CODE COMPLIANCE. FIRST STAGE VENTILATION: FIVE (5) CO SENSORS AND FIVE (5) NO2 SENSORS SPACED EVENLY IN THE SPACE SHALL BE SET TO LOW CONCENTRATION FAN RELAY ACTUATION SETTINGS, 35 PPM AND 2.5 PPM RESPECTIVELY. UPON DETECTION OF GAS, NORMALLY CLOSED MOTOR OPERATED DAMPERS SHALL PARTIALLY OPEN (60%) AND EXHAUST AND SUPPLY FANS SHALL RUN ON LOW SPEED. SECOND STAGE VENTILATION: THE OTHER FIVE (5) CO SENSORS AND FIVE (5) NO2 SENSORS SHALL BE SET TO HIGH CONCENTRATION FAN ACTUATION RELAY SETTINGS, 100 PPM AND 5 PPM RESPECTIVELY. UPON DETECTION OF GAS, PARTIALLY OPEN MOTOR OPERATED DAMPERS SHALL FULLY OPEN (100%) AND EXHAUST AND SUPPLY FANS SHALL RUN ON HIGH SPEED. PROVIDE MOTOR OPERATED DAMPERS WITH END SWITCH AND WIRE HIGH AND LOW SPEED START/ STOP SIGNALS THROUGH END SWITCH TO NOT ALLOW FAN TO OPERATE WITHOUT PROOF DAMPER IS OPEN. MACURCO GAS DETECTION EQUIPMENT HAS BEEN ESTABLISHED AS BASIS OF DESIGN. IF A SUBSTITUTE IS SUBMITTED, CONTRACTOR SHALL PROVIDE SUBMITTALS AND SHOP DRAWINGS TO ENGINEER FOR REVIEW AND VERIFICATION OF EQUIVALENCY. OPERATIONAL INTENT FOR PARKING GARAGE VENTILATION SYSTEM BI DAMPER POSITION OPEN/CLSD BO DAMPER END SWITCH BI LOW SPD FAN START/STOP BI HIGH SPD FAN START/STOP HORN/STROBE INTEGRAL TO CONTROLLER. CONTROL PANEL, BASED ON MACURCO DVP-120M HIGH CONCENTRATION LIMIT BO LOW CONCENTRATION LIMIT BO HIGH CONCENTRATION LIMIT LOW CONCENTRATION LIMIT AI AI AO NO2 CO AO AO NO2 CO AO SENSOR COMBO. TWO SEPARATE UNITS MOUNTED 60" AFF, TYP OF 10 (20 TOTAL SENSORS). BASED ON MACURCO CM-6 FOR CARBON MONOXIDE AND MACURCO TX-6-ND FOR NITROGEN DIOXIDE. 5 PAIRS OF SENSORS ARE SET TO LOW DETECTION LEVELS AND ENABLE LOW SPEED VENTILATION. REMAINING SENSORS ARE SET TO HIGHER THRESHOLD AND ENABLE HIGH SPEED VENTILATION. DAISY CHAIN SENSOR WIRING PER MFR. REQUIREMENTS. SCALE: NONE CONTROLS FLOW DIAGRAM 1 MEP-4 APPLIES TO: EXHAUST FAN, TYP 3. SUPPLY FAN, TYP 3. M SCALE: NONE (E) ROOF FAN DEMOLITION 2 MEP-4 SCALE: NONE (N) ROOF FAN INSTALLATION 3 MEP-4 M REMOVE (E) GRILLE AT LOCATIONS SCHEDULED TO RECEIVE SUPPLY FAN. REMOVE (E) ROOF FAN AND PREPARE FOR (N) ADAPTER FOR UPRIGHT (VERTICAL) INSTALLATION. PROVIDE (N) DOUBLE WALL W/ 2" INSULATION, CUSTOM CURB ADAPTER WITH FULLY WELDED SEAMS TO TRANSITION (E) ROOF PENETRATION TO ALLOW FOR (N) FAN INSTALLATION ON TYPICAL LEVEL CURB SURFACE. INSTALL (N) SINGLE DEFLECTION AERO BLADE GRILLE (BASED ON TITUS 271) TO DIRECT FLOW STRAIGHT DOWN, FOR SUPPLY FANS ONLY. ROOF (N) CURB ADAPTER (N) EXHAUST/SUPPLY FAN MOTORIZED DAMPER ROOF (303) 900-8782 PO Box 3699, Evergreen, CO 80437 STBENGR.COM INFO@STBENGR.COM 1295 WESTHAVEN DRIVE VAIL, CO 81657 12/30/16