Loading...
HomeMy WebLinkAboutB16-0031_A10.1_1480362930.pdfA4.3 A4.4 1 1 A4.1 1 A4.5 2 A4.5 3 1 A5.5 1 A5.7 1 A5.6 2 A5.5 A4.5 1 1 A5.1 4 A5.5 2 A5.7 1 A5.2 1 A5.3 2 A5.4 3 A5.5 1 A5.8 1 A5.9 BEDROOM #5 015 AV EQUIP. RM. 012 BATH #5 011 W.C. 010 HALLWAY 007 STORAGE 009 LAUNDRY ROOM 006 WINE RM. 003 WET STORAGE 004 FAMILY ROOM 001 MECHANICAL ROOM 008 EXERCISE EQUIPMENT STORAGE 017 POWDER 005 STAIRS 002 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F H H K K L L M M G1 G4 GD GD GC GC GA GA GB GB I I J J G5 G2 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 15' - 0 1/2" 11 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" 13' - 2"8' - 6 1/2"1' - 9 1/2" 23' - 6" 17' - 4 1/2" 6' - 7 1/2" 5' - 9" 1' - 9 1/2"8' - 6 1/2"13' - 2" 1' - 3" 1' - 0"1' - 4"10" 12' - 3" 3' - 6" 2 3/8" 8' - 11 3/16" 6 5/16" 4' - 11 1/8" 3' - 0" 37' - 9" 23' - 6" G3 1 A5.10 FAN FAN E Q Q H2 H2 FAN FAN U U D5 D5 A A A A A A A A A A A A A A A A A A A A A A5 L H2 H2 A A L A3 A3 CLG FAN L2 L2 Q2 Q2 FAN A A F H H H2 L2 L A A PROVIDE POWER FOR FUTURE LIGHTING DESIGN AND FUTURE COOLING PER MECH. SPEC. Q2 55" TV ABOVE FIREPLACE WOOD WRAPPED STEEL BEAMS RE: STRUCT. TV BATH #5 SHOWER 011B LED LIGHTING IN CABINETRY ON LIGHTING SYSTEM MS CNTR FRIDGE CNTR ICE MAKER CNTR PROVIDE POWER IN MECHANICAL ROOM PER MECHANICAL EQUIPMENT AND SPEC. B.O. SOFFIT @ 7 1/4" GAS OUTSIDE AIR INTAKE FOR KITCHEN MAKE UP AIR SYSTEM RE: MECH. SHALLOW FLOOR STRUCTURE ZONE FOR MECHANICAL DUCTS. RE: STRUCT.. AC UNIT COMPRESSOR PROVIDE POWER FOR MASTER BEDROOM A/C COMPRESSOR UNIT PER MECH. SPEC. PROVIDE POWER FOR POTENTIAL A/C/ @ MAKE UP AIR AND BEDROOM #3 PROVIDE POWER FOR AV EQUIPMENT PER AV CONSULTANT AND EQUIPMENT SPEC. CNTR 220 WASHER CNTR GFI GFI GFI 220 9 A6.7 FLOOR LAMPS 3' - 5 7/8" 3' - 5 7/8" A U 7"X9" ACTUAL 9"X9" ACTUAL A D9 (2) BUNK READING LIGHTS 1-HIGH; 1-LOW. D7 D7 F UPLIGHTS A2 A A A A A5 K K K1 4 A4.5 A A A B.O. SOFFIT @ 9' - 8 5/8" AFF B.O. GWB @ 9' - 0 3/4" AFF B.O. GWB @ 9' - 0 3/4" AFF B.O. GWB @ 9' - 0 3/4" AFF B.O. GWB @ 8' - 2 3/8" AFF B.O. GWB @ 8' - 3" AFF B.O. GWB @ 9' - 0 3/4" AFF (2) OUTLETS 1-HIGH; 1-LOW. TELEPHONE/ DATA G G A4.3 3 A4.2 1 Q 1 A5.11 4 7/8" PRE-WIRE SHADE POCKET FOR FUTURE MOTORIZED SHADE. INSTALL MANUAL SHADE. PRE-WIRE SHADE POCKET FOR FUTURE MOTORIZED SHADE. INSTALL MANUAL SHADE. JS 001 002 003 1 A8.1 1 A8.1 2' - 11 3/4" 2' - 11 3/4" 2' - 11 3/4" 2' - 11 3/4" K 1 7/8" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 9/16/2016 10:40:46 AM A10.1 LOWER LEVEL RCP CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS GENERAL NOTES: 1) EXTERIOR LIGHTING: 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 14 LIGHTS ARE ALLOWED. 14 EXTERIOR LIGHTS MORE THAN 18" ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES. (1) WALL MOUNTED HEVI LITE HL-340-LED SCONCE (TYPE E) LIGHTS PROVIDED @ THIS LEVEL (3) WAC LIGHTING WL-LED200 STEP LIGHT (TYPE Q) LIGHTS PROVIDED 1' - 0" ABOVE F.F. @ THIS LEVEL ________________________________________ 1 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE GRADE AT THIS LEVEL 2) (0) MOTORIZED SHADES SHOWN ON THIS LEVEL. 3) PROVIDE SHADE POCKETS @ ALL WINDOWS. 4) PRE-WIRE U.N.O. 1/4" = 1'-0" 1 LOWER LEVEL REFLECTED CEILING PLAN CLG FAN CLG FAN - UPATED GENERAL NOTE AND SHADE COUNT. - SWTCHES AND WIRING MODIFIED IN BEDROOM #5 - WINDOW TAGS ADDED No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16