HomeMy WebLinkAboutB16-0031_A10.2_1480363022.pdfA4.3
A4.4
1
1
A4.1
A4.2
1
1
A4.5
2
A4.5
3
1
A5.5
1
A5.7
1
A5.6
2
A5.5
A4.5
1
1
A5.1
4
A5.5
2
A5.7
1
A5.2
1
A5.3
1
A5.4
2
A5.4
3
A5.5
1
A5.8
1
A5.9
MASTER CLOSET
102
MASTER
BEDROOM
105
MASTER BATH
103
SHOWER
FRONT ENTRY
101
LIVING ROOM
106
DINING ROOM
107
STAIR
116
KITCHEN
108
BREAKFAST
NOOK
110
HEARTH ROOM
111
POWDER
112
MUDROOM
113
GARAGE
114
OUTDOOR LIVING
ROOM
109
M
M
M
M
Q
Q
1
1
2
2
3
3
4
4
5
5 6
6 7
7 8
8 9
9
10
10 11
11 12
12
A
A
B
B
C
C
D
D
E
E
F
F
H
H
K
K
L
L
M
M
G1
G4
GD
GD
GC
GC
GA
GA
GB
GB
I I
J J
G5
G2
2' - 4" 3' - 6 1/2" 4' - 5 1/2" 15' - 0 1/2" 11 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4"
82' - 2"
13' - 2"8' - 6 1/2"1' - 9 1/2"
23' - 6"
1' - 3"
1' - 0"1' - 4"10" 12' - 3" 3' - 6" 2 3/8" 8' - 11 3/16" 6 5/16" 4' - 11 1/8" 3' - 0" 37' - 9"
17' - 4 1/2"
6' - 7 1/2"
5' - 9"
29' - 9"
G3
E
1
A5.10
Q
J-BOX J-BOX
M
M
M
M
M
M
M
A
A A
A
A
A
A A A A
A
A
A
A
Q Q
P
P
U
U
L
L
L
L
M
J-BOX
B
B B
B
A2
A A
A
A
FAN
11' - 6" 9' - 4 1/4"
F
FAN
A A
A A
U
U
U
U
B
B
B
B
B
B
B
B
B
B
B
B
L
B
B
B B B
B
B
FAN
A
CLG
FAN
B B
B B
L2
J-BOX J-BOX
J-BOX
A2
J-BOX
L2
B
Q2
Q2
A
A
C C C C
C
Q2
A
A
A 4" / 12"
Q
Q
Q
Q
Q
3' - 8 7/8"
6' - 0" 3' - 9 1/4" 5' - 7" 5' - 7"
9
A6.8
2' - 5 1/8" 2' - 5 1/8"
5' - 7" 5' - 7" 5' - 7" 5' - 7"
HEATSTRIP OUTDOOR HEATERS
DECK GUTTER
GAS
GAS
STEAM SHOWER . PROVIDE STEAM
GENERATOR AND ACCESS IN
STORAGE CLOSET/LOWER LEVEL
MECH. ACCESS HATCH FOR
MASTER BEDROOM A/C
EQUIPMENT.
GFI
GFI
FRIDGE
DOUBLE
OVEN
220
CNTR
DW
CNTR
DISP.
CNTR
DISP.
CNTR
RANGE
CNTR
HOOD
J-BOX
J-BOX
J-BOX
JS
J-BOX
J-BOX
J-BOX
LOW ON WALL FOR HEAT TAPE
J-BOX
J-BOX
LOW ON WALL FOR HEAT TAPE
GAS
TV ABOVE FIREPLACE
PROVIDE NICHE IN STONE VENEER
FOR TV BRACKET W/ POWER AND
CONNECTION
L
8X8 APPLIED WOOD BEAMS
8X8 APPLIED
WOOD BEAMS TV
GAS
DECK GUTTER
DECK GUTTER
7
A6.8
J-BOX FOR HEAT TAPE
L
L
3' - 8 5/8"
3' - 8 5/8" A
A A A A
FLOOR LAMPS
A
1' - 11" 1' - 11" 3' - 10"
EQ EQ F
A A
8X8 APPLIED
BEAMS
8X10 APPLIED
BEAMS
B
B
B
4' - 0"
4' - 2 1/16"4' - 2 1/16"4' - 2 1/16"4' - 2 1/16"4' - 2 1/16"4' - 2 1/16"
L
L
6"
6"
A3
A3 A3
A3
A A
C C
8X8 APPLIED
WOOD RAFTERS
K
K
K
K
K
K
K
K
K
K
K1
K1
AIR RETURN
RE: MECH. PLANS 3' - 9 1/4"
H
H
H
H
A3
A3
A3 A3
A3 A3 HSS8X4X.375
5 5/16"
A
A
J-BOX
4
A4.5
B.O. DECKING @ 10' - 9" AFF
B.O. GWB @ 9' - 6" AFF
B.O. DECKING @ 10' - 8 3/8"
B.O. GWB @ 10' - 8 1/2" AFF
B.O. GWB @ 9' - 0" AFF
B.O. GWB @ 8' - 10 5/8"
B.O. GWB @ 10' - 0" ABOVE CONC.
B.O. GWB @ 9' - 6" AFF
B.O. GWB @ 10' - 8 1/2" AFF
11' - 1 1/2"
4
A6.8
10X10 WOOD
WRAPPED STEEL BEAM
RE: STRUCT
4
A8.1
7
A8.2
7
A8.1
1
A8.2
NO SHADE POCKET REQ'D @
MASTER SHOWER WINDOW.
PROVIDE FROSTED GLASS.
RE: WINDOW SCHEDULE
3
A6.8 TELEPHONE/
DATA
TELEPHONE/
DATA
TELEPHONE/
DATA
F
JS
G
G
A
A
A
A
A4.3 3
9' - 6"
5
A6.8
12
A8.1
Q
Q
TO LIGHTS @ LOWER LEVEL
Q
Q
Q
Q
Q
Q
Q
Q
LOCATE Q-LIGHT @
STEP FOR SAFETY
1
A5.11
NO PRE-WIRE FOR SHADE
POCKET. MANUAL SHADE
ONLY.
NO PRE-WIRE FOR SHADE POCKET.
MANUAL SHADE ONLY.
NO WIRE FOR SHADE
POCKET; MANUAL SHADE
ONLY
NO WIRE FOR
SHADE POCKET;
MANUAL SHADE
ONLY.
NO WIRE FOR
SHADE POCKET;
MANUAL SHADE
ONLY.
NO SHADE POCKET AT
DOOR. NO PRE-WIRE
AT DOOR.
A
FAN
103
102
101
104
105
106
107
108
109
110
111
112
113
114
115
116
117
K
10' - 8 3/8"
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
9/16/2016
10:40:53 AM
A10.2
MAIN LEVEL
RCP
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
GENERAL NOTES:
1) EXTERIOR LIGHTING:
1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 14 LIGHTS ARE ALLOWED. 14 EXTERIOR LIGHTS MORE THAN 18"
ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES.
(12) CEILING MOUNTED HEVI LITE HL-384 MONOPOINT (TYPE M) LIGHTS PROVIDED @ THIS LEVEL
(1) WALL MOUNTED HEVI LITE HL-340-LED SCONCE (TYPE E) LIGHTS PROVIDED @ THIS LEVEL
(13) WAC LIGHTING WL-LED200 STEP LIGHT (TYPE Q) LIGHTS PROVIDED LESS THAN 18" ABOVE F.F. @ THIS LEVEL
________________________________________
13 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE GRADE AT THIS LEVEL
2) (20) MOTORIZED SHADES SHOWN ON THIS LEVEL.
3) PROVIDE SHADE POCKETS @ ALL WINDOWS U.N.O.
4) PREWIRE FOR MOTORIZED SHADES @ ALL WINDOWS U.N.O.
1/4" = 1'-0"
1
MAIN LEVEL REFLECTED CEILING PLAN
- UPATED GENERAL NOTE AND
SHADE COUNT.
- SHADE POCKET NOTES ADDED
- MOTORIZED SHADE ADDED
- ART LIGHT ADDED IN MASTER BED
- WINDOW TAGS ADDED
No. Revision Date
Revision
Description
1 APRIL 26, 2016 ASI #1
5 AUGUST 12,
2016
ASI #5
11/28/16