Loading...
HomeMy WebLinkAboutB16-0031_A2.3_1480362964.pdfUTI LI T Y EASEMENT 20.00' GGGGGGGGGGGGG GGG G G GGGGGGG T T TT TT TTTT TTTT T X XXXXX XX XX XX XXXXXX XX XX8310 BOOTH CREEK DRI VE (40' R.O.W) LOT 9 LOT 7LOT 8TRACT C N 14°39'30" W113.67' S 75°20'30" W125.00' N 14°39'30" W110.53' S 58°19'45" W11.15' C1C2 02 04 06 08 12 140204 06 06 06 0608 CS P P PE12' E08' E06' E08' E06' E04' E02' E02' E04' E02' E14' E14' E12' E06' E06' 06 T GGGG GGGGG GGGGG G G XX E10' E10' CORE DRILL #1 (2) LARGE SPRUCE TREES TO BE REMOVED (4) ASPEN TREES TO BE REMOVED (5) ASPEN TREES TO BE REMOVED 3 CONIFER TREES TO BE REMOVED (3) ASPEN TREES TO BE REMOVED (1) CONIFER TREES TO BE REMOVED 100 YEAR FLOOR PLAIN LINE PHONE PEDESTAL PHONE PEDESTAL W W W W W W E E E E E G G G S S S S S S S S PHONE PEDESTAL PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LI NE ELECTRICAL TRANSFORMER DISCHARGE SITE DRAINAGE AND DAY LIGHT DOWN SPOUT DRAIN PIPE. PROVIDE COBBLE DISCHARGE AREA TO PREVENT EROSION. DAYLIGHT FOUNDATION PERIMETER DRAIN @ 8300.5' LI MIT OF DISTURBANCE LIMIT OF DISTURBANCE LIMIT OF DISTURBANCE NEW GAS LINE CONNECTION EDGE OF EXI STI NG ROAD WATER TAP CONNECTION LINE OF SITE DISTANCE REQUIREMENTS - FORWARD PARKING IS PROPOSED, THEREFOR THERE SHOULD BE NO SITE OBSTRUCTIONS WITHIN 10' FROM EDGE OF PAVEMENT AND 250' IN EACH DIRECTION. 15' SIDE SETBACK 2 0' FR O N T S E T B ACK 20' FRONT SETBACK 15' SIDE SETBACK 15' REAR SETBACK BUILDING FOOT PRINT OF EXISTING HOUSE LIMITS OF DISTURBANCE WATERFALL CLIFFS GORE RANGE GORE RANGE BUILDING FOOTPRINT OF EXISTING HOUSE LIMITS OF DISTURBANCE SILT FENCE INSTALLED AT LIMITS OF DISTURBANCE ALONG DOWNHILL SECTIONS OF SITE PER LANDSCAPE ARCHITECTS REQUIREMENTS. PROPOSED ELECTRICAL METER LOCATION PROPOSED UNIT WATER SERVICE LINE T T T T T T LINE OF EXISTING DRIVEWAY NEW 4" WATER SERVICE LINE CONNECTS TO "T" TO CURB STOP EXISTING TELEPHONE LINE TO BE ABANDONED PROPOSED GAS METER LOCATION EXISTING MARKED GAS LINE PROPOSED CURBSTOP AT PROPERTY LINE BUILDING FOOTPRINT OF PROPOSED HOUSE BUILDING FOOTPRINT OF PROPOSED HOUSE W W W W W W (8) DECIDUOUS TREES TO BE REMOVED GENERAL NOTES: 1) LIMITS OF DISTURBANCE AND FENCING TO BE PLACED AT THE DRIP EDGE OF TREES OR AS APPROVED BY ARBORIST. 2) PRIOR TO DEMOLITION ALL EXISTING UTILITIES WILL BE TURNED OFF AND DISCONNECTED AS FOLLOWS: CONTRACTOR TO BE RESPONSIBLE FOR COORDINATING THE DISCONNECT OF ALL UTILITIES WITH THE APPROPRIATE UTILITY COMPANIES / DEPARTMENTS. ELECTRICAL: TO BE DISCONNECTED AT EXISTING METER LOCATION AT THE NORTH EAST SIDE OF LOT. DESIGN BUILD SUBCONTRACTOR WILL PROVIDE NEW LARGER AMPERAGE SERVICE TO REPLACE THE EXISTING SERVICE. PHONE: TO BE DISCONNECTED AT PHONE PEDESTAL AT THE NORTH WEST CORNER OF LOT. NEW SERVICE TO BE RUN IN CONDUIT TO HOUSE. CABLE: TO BE DISCONNECTED AT TV BOX LOCATION BEYOND THE NORTH WEST CORNER OF THE LOT. WATER: TO BE TURNED OFF AT EXISTING WATER VALVE AS NOTED ON SURVEY. NEW 4" WATER SERVICE LINE CONNECTS TO NEW CURB STOP AT PROPERTY LINE. NEW WATER SERVICE TO BE PROVIDED AS NOTED ON MECHANICAL/ PLUMBING DRAWINGS. GAS: TO BE TURNED OFF AT EXISTING GAS VALVE. GAS LINE TO BE CUT JUST SOUTH OF THE VALVE (HOUSE SIDE OF VALVE). NEW SERVICE TO BE PROVIDED AS NOTED ON MECHANICAL/PLUMBING DRAWINGS. SEWER: APPROXIMATE LOCATION OF SEWER LINE IS SHOWN ON SHEET A2.0. NEW SEWER LINE CONNECTS TO EXISTING EAGLE RIVER WATER AND SANITATION DISTRICT SEWER LINE BEYOND THE SOUTH WEST CORNER OF THE PROPERTY. 3) PROVIDE CONSTRUCTION FENCE AROUND PROPERTY AT LIMIT OF DISTURBANCE SHOWN ON DEMO PLAN. 4) PROVIDE SILT FENCING AT DOWNHILL AREAS OF PROPERTY. 5) SITE TO RE RE-GRADED TO PRE-CONSTRUCTION EXISITING GRADE IF PROPOSED STRUCTURE IS NOT CONSTRUCTED. 6) SITE TO BE REVEGITATED TO NATIVE CONDITION IF PROPOSED STRUCTURE IS NOT CONSTRUCTED. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 9/16/2016 10:31:46 AM A2.3 DEMO PLAN CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1/8" = 1'-0" 1 DEMO PLAN 0' 4' 8' 16' 32' NORTH No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16