Loading...
HomeMy WebLinkAboutB16-0031_A5.6_1480363135.pdfMAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" LOWER LEVEL FINISHED FLOOR 1' - 6 1/4" T.O. PLATE @ 9' - 1 7/8" 1 A5.1 4 A5.5 1 A5.2 1 A5.3 1 A5.4 T.O. PLATE @ 12' - 3" LINE OF EXISTING GRADE POWDER 112 STAIR 116 FRONT ENTRY 101 MASTER BEDROOM 105 MASTER BATH 103 BEDROOM #5 015 STORAGE 009 LAUNDRY ROOM 006 FAMILY ROOM 001 2 1/2" / 12" 6" / 1 2 " B.O. HEADER @ 9' - 0 3/8" BATHROOM #2 218 A6.10 1 1 A5.9 B.O. STRUCT. @ 10' - 9 3/4" AFF A6.7 2 A8.1 1 A6.3 3 A8.1 6 4 002 3 002 39 115 42 115 50 115 38 115 1 2 3 4 5 6 7 8 9 10 11 12 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 15' - 0 1/2" 11 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" 6" / 12" B.O. CEILING @ 9' - 6" AFF T.O. MAT SLAB @ 2 1/2" B.O. HEADER @ 7' - 6 3/4" A6.11 3 12 A8.1 A6.4 1 10' - 5" 12' - 0" T.O. STRUCTURE @ 38' - 9 3/4" T.O. STRUCTURE @ 39' - 5 7/8" 10" B.O. CEILING @ 9' - 6" AFF 32' - 9 3/4" B.O. STRUCT. @ 9' - 1 3/8" AFF FINISH TO FINISH 9' - 0 3/4" 5 002 6 A7.8 B.O. CELING @ 9' - 6" AFF T.O. TOPPING SLAB @ 8" T.O. MAT SLAB @ 2' - 1 1/4" T.O. TOPPING SLAB @ 2' - 2 3/4" 4" BATHROOM EXHAUST VENTS. RE: MECH. FINISH TO FINISH 10' - 8 1/2" T.O. CONC. @ 4' - 8 1/8" 1/4" / 12" T.O. STL. BEAM @ 38' - 0 5/8" W12X19 W16X36 W10X39 W10X39 W18X65 T.O. STL. BEAM @ 11' - 6" T.O. STL. BEAM @ 11' - 6" T.O. STL. BEAM @ 11' - 6" T.O. STL. BEAM @ 34' - 7 5/8" B.O. CEILING @ 10' - 2" AFF B.O. CEILING @ 9' - 0" AFF B.O. HEADER @ 9' - 6 3/4" T.O. CONC. TO B.O. STRUCT. 9' - 2 1/8" T.O. PLATE @ 11' - 2 1/2" T.O. PLATE @ 11' - 9" B.O. SOFFIT @ 8' - 3 1/8" ABOVE CONC. 11.2° B.O. HEADER @ 7' - 11 3/4" A6.8 8 T.O. C-CHANNEL @ 10' - 3 1/4" T.O. C-CHANNEL @ 11' - 1 3/8" C10X15.3 C10X15.3 SEE SHEET A9.7 FOR INTERIOR ELEVATION OVER FRAMING 4' - 0" OVER FRAMING OVER FRAMING BEDROOM #3 FAN COIL FOR A/C LOCATED ABOVE LAUNDRY ROOM RE: MECH PLANS AND RCP FOR IN-CEILING ACCESS HATCH LOCATION. 2' - 6" 28 T.O. CONC. @ 3' - 6 1/4" T.O. CONC. LEDGE @ 2' - 11 1/4" T.O. CONC. @ 5' - 3 1/4" 1/8" / 12" 1/8" / 12" 1/8" / 12" B.O. CEILING @ 9' - 6" AFF 4' - 1" 2' - 1 1/4" 1' - 10 3/4" 1' - 9" B.O. HEADER @ 10' - 4 7/8" 9 A6.7 1' - 1" PRE-WIRE SHADE POCKET FOR FUTURE MOTORIZED SHADE. INSTALL MANUAL SHADE. 1 3/4" 7 1/2" 4 1/4" 3' - 0 5/8" 1' - 9 1/16" 3 5/16" 11' - 7" 8' - 2 9/16" 10 1/2" 2 3/8" 34' - 9 1/8" 1 1/2" W14X22 Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 9/16/2016 10:36:03 AM A5.6 BUILDING SECTIONS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1/4" = 1'-0" 1 Section 10 No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16