HomeMy WebLinkAboutB16-0031_A6.2_1480363170.pdfT.O. CONCRETE WALL
RE: SECTIONS
SLOPE TO DRAIN
GARAGE
EXTERIOR
CONC. SLAB W/ IN-FLOOR
RADIANT HEAT SLOPED
PER PLANS
10 MIL. VAPOR BARRIER TURNS UP
WALL MECH. FASTEN AND SEAL TO
WALL. SEAL ALL JOINTS AND
PENETRATIONS TYP. RE: SPEC
MIN R-10 RIGID FOAM INSULATION PANEL @
GARAGE LOCATIONS LESS THAN 1' - 0" BELOW
GRADE RE: SPEC OVER WATERPROOF
MEMBRANE. ALTERNATE COMBINATION
INSULATION / DRAINAGE MEDIUM MAY BE
PROPOSED PER SPEC.
GRAVEL BED PER SOILS ENGINEER, STRUCT
AND CIVIL DRAWINGS
SMART MEMBRANE VAPOR BARRIER RE: SPEC
5/8" GYP SHEATHING OR MOISTURE
RESISTANT DRYWALL
OUTSWING DOOR RE: DOOR SCHEDULE.
POUR SLAB AFTER ELECTRIC
CONDUIT IS INSTALLED
P.T. PLYWOOD OVER FOUNDATION
WATERPROOFING OVER CONCRETE
FOUNDATION & WITHIN 6" OF GRADE
RE:SPEC
ELECTRIC CLOSET
1/2" EXPANSION JOINT
NOTE: SEE 1 / A6.1 FOR TYPICAL
FOUNDATION NOTES
CONC. FOUNDATION BEYOND
1/2" P.T. PLYWOOD RAMSET TO
CONCRETE
NON PAPER-FACED GYP. SHEATHING
OVER CONCRETE
RE: STRUCT.
RE: STRUCT.
GRID
LINE
GRID
LINE
8" 5"
LINE OF STONE VENEER BEYOND
SLOPE
SLOPE
RE: STRUCT.
CONC. PATIO W/ SNOW MELT RE: PLANS
6" STEP
T&G WOOD SIDING @ INTERIOR OF
ELECTRICAL CLOSET.
36" BITUTHANE LAP OVER FOUNDATION
MIN. 12" AND CONT. UP PLYWOOD AND
WALL.
W.P. EPOXY LIQUID GRANITE FLOORING
OVER CONC. SLAB AND TURNS UP WALL
MIN. 6"
T.O. CONC.
RE: SECTIONS
INTERIOR
MUDROOM
GARAGE
GRID
LINE
RE: STRUCT.
2 1/4"
4' TYPICAL RE: STRUCT.
SEE 1 / A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
SEE 2/A6.1 FOR TYP.
GARAGE SLAB AND INT.
WALL ASSEMBLY
SLOPE
5/8" TYPE X GWB @ GARAGE
RE: STRUCT. 2 1/2" 5 1/2"
SLOPE
2 1/2" 4" MIN.
6" MAX 10" 5"
2"
1' - 0"
8 1/4" MAX
1' - 2 3/4"
2 1/4" TILE FLOOR ASSEMBLY.
RE: PLANS AND FINISH
SCHEDULE
5 1/2"
5 1/2" LVL FLOOR STRUCTURE
@ MUDROOM. RE: STRUCT.
VAPOR BARRIER RE: SPEC.
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR EXTERIOR
GRID
LINE
STRUCTURAL SLAB
RE: STRUCT.
RE: STUCT.
4' TYPICAL RE: STRUCT.
SLOPE PER PLANS
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
LIFT AND SLIDE DOOR RE: WINDOW SCHEDULE
W.P. MEMBRANE CONT. UNDER DOOR SILL
TURNS UP 1 1/2" VERTICAL OVER METAL
FLASHING @ BACK EDGE OF DOOR SILL.
METAL FLASHING UP CONC. WALL, UNDER
DOOR SILL AND TURNS UP 1 1/2" VERTICAL @
BACK EDGE OF DOOR SILL
SEE 2/A6.1 FOR TYP. PATIO
ASSEMBLY
RE: STRUCT. 1' - 6"
LEDGER RE: STRUCT.
7 1/2" 5 1/2"
CENTOR SCREEN RE: WINDOW SCHEDULE
INSULATION PANEL
RE: SPEC AND COVER SHEET
A6.6
1
SLOPE
7" 6"
2 1/2" AIR SPACE TYP.
2X4 WALL TYP.
1/2" 6" MAX 4" MIN.
10" 5"
2 1/2"
1' - 0"
8 1/4" MAX
3" WOOD FLOOR ASSEMBLY. RE: PLANS
3"
4" STEP
EXTERIOR
6" THICKEND CONC.
SLAB EDGE SLOPED PER
SITEPLAN
2" RIGID R-10 INSULATION UNDER SLAB
RE: SPEC
APPROX. 1' - 6" CONC. APRON
VERIFY PAVER
THICKNESS W/ FINAL
SPECIFICATIONS
SLOPE
2" SAND BED WITH RADIANT HEAT TUBING
(2) #5 REBAR
GROUT UNDER 11" SOLDIER
COURSE CONC. PAVER
BORDER
CONC. PAVER BORDER
6"
T.O. PLYWOOD
RE: PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
4' TYPICAL RE: STRUCT
T.O. CONC.
RE: PLANS
T.O. CONC.
RE: PLANS
SLOPE
RE: STRUCT.
SLOPE
1/2"
7 1/2" 5 1/2"
6" MIN
6" MAX 6" MAX 4" MIN.
10" 5"
RE: STRUCT.
2 1/2"
SEE 1/A6.1 FOR TYPICAL W.P.
FOUNDATION ASSEMBLY
SEE 1/A6.1 FOR TYPICAL
STONE VENEER ASSEMBLY
1' - 0"
3"
8 1/4" MAX 3" FINISH FLOOR ASSEMBLY
RE: PLANS
GRID
LINE
INTERIOR OF GARAGE EXTERIOR
FINISHED WALL
BEYOND
RE: STRUCT.
RE: STRUCT.
SLOPE
CONC. WALKWAY W/
SNOW MELT RE:
SPEC.
SLOPE
SEE 2/A6.1 FOR TYP. GARAGE
FOUNDATION ASSEMBLY
SEE 2/A6.1 FOR TYP.
GARAGE SLAB
ASSEMBLY
6" STEP
BED DOOR THRESHOLD IN (2) ROWS OF
CONT. BUTYL SEALANT
6 1/2"
7 1/2"
2" INSULATION.
RE: SPEC AND
COVER SHEET
1" RIGID FOAM
INSULATION
14"
RE: STRUCT.
COORDINATE ELEVATION OF DRAIN WITH
PERIMETER DRAIN SYSTEM @
FOUNDATION WALLS CHECK WITH
STRUCTURAL RE: DRAIN BELOW FOOTING
ELEVATION
2"
INTERIOR OF GARAGE
EXTERIOR
2X TRIM BOARD AT GARAGE DOOR
JAMB BEYOND
RE: STRUCT.
RE: STRUCT.
2" RIGID UNDER CONC. SLAB
5" HEATED CONC. SLAB SLOPE TO DRAIN
W.P. MEMBRANE CONT. FROM B.O.
FOOTING TO T.O. CONC.
SLOPE
CONC. FOUNDATION FOOTER RE: STRUCT.
TYP. FOUNDATION DRAINAGE SYSTEM
PER SOILS REPORT, SPEC & CIVIL
DRAWINGS
GRID
LINE
SLOPE GARAGE SLAB AT THRESHOLD
HEATED DRIVEWAY CONC. SLAB RE: STRUCT.
FLAGSTONE BORDER
MIRADRAIN DRAIN DRAINAGE MEDIUM.
MIRADRAIN IS CONT. @ WALL AND TOP OF
FOOTING
RE: SPEC
2" RIGID R-10 INSULATION PROVIDE
HIGH COMPRESSIVE STRENGTH RE:
SPEC.
0' - 1"
DOWEL SLABS TOGETHER RE: STRUCT.
GARAGE DOOR
PROVIDE GASKET AT B.O. GARAGE DOOR
3"
SEE 2/A6.2 FOR TYP. PATIO ASSEMBLY
8" 5"
10 MIL VAPOR BARRIER
COORDINATE ELEVATION OF DRAIN WITH
PERIMETER DRAIN SYSTEM @
FOUNDATION WALLS CHECK WITH
STRUCTURAL RE: DRAIN BELOW FOOTING
ELEVATION
5"
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1 1/2" = 1'-0"
9/16/2016
10:37:07 AM
A6.2
FOUNDATION
DETAILS
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0"
2
FOUNDATION DETAIL @ ELECTRICAL
CLOSET
1 1/2" = 1'-0"
1
FOUNDATION DETAIL @ GARAGE AND
LOWER LEVEL
1 1/2" = 1'-0"
3
FOUNDATION DETAIL @ LIFT AND SLIDE
DOOR THRESHOLD
1 1/2" = 1'-0"
4
SAND SET PAVER DRIVEWAY BORDER
DETAIL
1 1/2" = 1'-0"
5
FOUNDATION DETAIL W/ JOIST BEARING
ON CONC. WALL
1 1/2" = 1'-0"
7
FOUNDATION DETAIL @ GARAGE MAN
DOOR THRESHOLD
1 1/2" = 1'-0"
6
FOUNDATION DETAIL @ GARAGE DOOR
THRESHOLD
- DETAILS UPDATED PER
STRUCTURAL COORDINATION
No. Revision Date
Revision
Description
1 APRIL 26, 2016 ASI #1
5 AUGUST 12,
2016
ASI #5
11/28/16