Loading...
HomeMy WebLinkAboutB16-0254_E001_signed_1507144320.pdfSYMBOL DESCRIPTION DUPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT DUPLEX RECEPTACLE, SPLIT WIRED, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT SINGLE RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT GFCI RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT 'H' INDICATES HORIZONTAL MOUNT QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM GFCI QUADRAPLEX RECEPTACLE, NEMA 5-20R, MOUNT +18" AFF, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AND MOUNTING AS INDICATED BRANCH CIRCUIT HOMERUN, HATCH MARKS INDICATE TYPE AND NUMBER OF CONDUCTORS, DASHED LINES INDICATE UNDER FLOOR/GROUND ROUTING, PROVIDE 3#12 IN 3/4" CONDUIT UNLESS OTHERWISE INDICATED. INDICATES PHASE CONDUCTOR INDICATES NEUTRAL CONDUCTOR INDICATES GROUNDING CONDUCTOR NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MANUAL MOTOR STARTER MAGNETIC MOTOR STARTER COMBINATION STARTER/DISCONNECT MOTOR DUPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT QUADRAPLEX RECEPTACLE, NEMA 5-20R, FLUSH FLOOR MOUNT FLOOR BOX, FLUSH FLOOR, WITH (2) DUPLEX RECEPTACLES AND SPACE FOR (2) SINGLE GANG TELECOMMUNICATION OUTLETS FLOOR BOX, POKE-THRU TYPE WITH (2) DUPLEX RECEPTACLES AND SPACE FOR TELECOMMUNICATION OUTLETS JUNCTION BOX SYSTEM FURNITURE CONNECTION, WALL AND FLOOR MOUNT PANELBOARD, SURFACE MOUNT PANELBOARD, RECESS MOUNT TRANSFORMER, DRY TYPE PLUG LOAD CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM DUPLEX RECEPTACLE, NEMA 5-20R, CEILING MOUNT, SUBSCRIPT 'S' INDICATES CONTROLLED RECEPTACLE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SURFACE RACEWAY, DEVICES AS INDICATED PLUGMOLD, OUTLET EVERY 12" ON CENTER, ALTERNATE NEMA 5-15R RECEPTACLE WITH USB CHARGING PORT POWER LEGEND GENERAL DEMOLITION NOTES DEMOLITION DRAWINGS ARE PROVIDED AS REFERENCE ONLY. DEMOLITION DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD INVESTIGATION AND EXISTING DRAWINGS. VISIT THE PROJECT SITE AND BECOME FAMILIAR WITH EXISTING FIELD CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. CLEAN AND REPAIR ALL EQUIPMENT INDICATED FOR REUSE OR SALVAGE. DISPOSE OF, IN A LEGAL MANNER, ALL MATERIALS INDICATED FOR REMOVAL AND NOT INDICATED FOR REUSE OR SALVAGE. MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS AND FEEDERS NOT INDICATED FOR REMOVAL BUT MAY BE DISTURBED BY THE WORK. REROUTE CIRCUITS AS REQUIRED DUE TO THE WORK. EXISTING CONDUIT MAY BE ABANDONED IN THE WALLS, FLOOR SLAB, AND BELOW GRADE ONLY. REMOVE CONDUITS TO THE SURFACE OF THE WALL/FLOOR AND PATCH. REMOVE UNUSED CABLING AND CONDUCTORS ALL THE WAY BACK TO THE SOURCE. 1. 2. 3. 4. 5. 6. 7. LIGHTING LEGEND SYMBOL DESCRIPTION LIGHT FIXTURE LIGHT FIXTURE ON EMERGENCY/NON-SWITCHED POWER LIGHT FIXTURE, WALL MOUNT LIGHT FIXTURE, WALL MOUNT, ON EMERGENCY/NON-SWITCHED POWER LIGHT FIXTURE, POLE MOUNT EXIT SIGN, WALL MOUNT +90" AFF AND CEILING MOUNT, SHADED SIDE INDICATES FACE(S) OF SIGN, DIRECTIONAL CHEVRONS AS INDICATED EGRESS LIGHT WITH BATTERY PACK, WALL MOUNT +90" AFF OCCUPANCY SENSOR, DUAL TECHNOLOGY, CEILING MOUNT, OMNI-DIRECTIONAL AND DIRECTIONAL PHOTO CELL LIGHT SWITCH, 120/277-VOLT, 1HP RATED, MOUNT +46" AFF, SUBSCRIPT INDICATES TYPE OF SWITCH: 3 - 3-WAY 4 - 4-WAY D - DIMMING K - KEY OPERATED M - OCCUPANCY SENSOR P - PILOT LIGHT LIGHT SWITCH, LOW VOLTAGE, MOUNT +46" AFF, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM, SUBSCRIPT INDICATES TYPE OF SWITCH: 3 - 3-WAY 4 - 4-WAY D - DIMMING K - KEY OPERATED M - OCCUPANCY SENSOR P - PILOT LIGHT ROOM CONTROLLER, MOUNT IN ACCESSIBLE ABOVE CEILING SPACE, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM LOW VOLTAGE CABLING FOR LIGHTING CONTROL SYSTEM, REFER TO LIGHTING CONTROL SYSTEM DIAGRAM SYMBOL DESCRIPTION CCTV CAMERA KEYPAD, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE CARD READER, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE CARD READER WITH KEYPAD, MOUNT +46" AFF, PROVIDE 3/4" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE MAGNETIC LOCK ELECTRIC STRIKE ELECTRIC LOCK GLASS BREAK SENSOR SECURITY LEGEND SYMBOL DESCRIPTION TELECOMMUNICATIONS OUTLET, MOUNT +18" AFF, PROVIDE 1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING SPACE TELECOMMUNICATIONS OUTLET, FLUSH FLOOR MOUNT, PROVIDE 1" EMPTY CONDUIT WITH BUSHING TO ACCESSIBLE ABOVE CEILING SPACE SOUND SYSTEM SPEAKER, CEILING AND WALL MOUNT COAXIAL CABLE TELEVISION OUTLET, MOUNT +18" AFF INTERCOM STATION, MOUNT +46" AFF 19" EQUIPMENT RACK TELECOMMUNICATIONS OUTLET, CEILING MOUNT, PROVIDE 1" EMPTY CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE TELECOMMUNICATIONS LEGEND GENERAL NOTES PROVIDE WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL ORDINANCES, AND AS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. OBTAIN PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF THE WORK. PROVIDE LABOR, MATERIAL, AND OTHER SERVICES AS MAY BE NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. NOTIFY THE ARCHITECT/ENGINEER AND RESOLVE ANY ISSUES EXPERIENCED DURING THE COURSE OF THE WORK PRIOR TO EXECUTION OF THE WORK. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING ITEMS: A. LIGHT FIXTURES B. PANELBOARDS / CIRCUIT BREAKERS C. SAFETY SWITCHES D. TRANSFORMERS E. WIRING DEVICES F. CONDUCTORS G. CONDUIT H. ALL OTHER ITEMS SPECIFIED BY MODEL NUMBER ON DRAWINGS SHOP DRAWINGS MUST BE APPROVED BY ENGINEER PRIOR TO PURCHASE. IF A SUBSTITUTION IS PROPOSED, BE PREPARED TO PROVIDE SAMPLES FOR EVALUATION. PROVIDE MATERIAL WITHIN ONE YEAR OF MANUFACTURE, BEARING A U.L. LABEL, AND LISTED FOR ITS INSTALLED APPLICATION. PROVIDE MAJOR COMPONENTS OF THE ELECTRICAL SYSTEM BY THE SAME MANUFACTURER. USE MOUNTING HEIGHTS INDICATED ON THE LEGEND EXCEPT WHERE INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS ARE MEASURED FROM THE MIDDLE OF WALL MOUNTED DEVICES AND FROM THE BOTTOM OF PENDENT MOUNTED DEVICES. ASSEMBLE, HANG, AND CONNECT LIGHTING FIXTURES FURNISHED COMPLETE WITH SOCKETS, TRIM HANGERS, SUPPORTS, ETC, AS REQUIRED FOR A COMPLETE INSTALLATION. MOUNT LIGHT FIXTURES SUPPORTED INDEPENDENTLY OF SUSPENDED CEILING COMPONENTS. PROVIDE "LOCKING" TYPE DEVICES ON CIRCUIT BREAKERS CONNECTED TO EMERGENCY LIGHTING, NIGHT LIGHTING, FIRE ALARM, AND SECURITY SYSTEMS. IN FINISHED SPACES: FLUSH MOUNT LIGHT SWITCHES, RECEPTACLES, AND TELECOMMUNICATIONS OUTLETS, ROUTE RACEWAYS CONCEALED. PROVIDE MOTOR OVERLOAD DEVICES IN STARTERS BASED ON NAMEPLATE RATING ON THE MOTORS BEING INSTALLED. PROVIDE "HACR" TYPE CIRCUIT BREAKERS FOR CIRCUITS THAT SERVE HEATING, AIR CONDITIONING, OR REFRIGERATION EQUIPMENT. PROVIDE MINIMUM #10 NEUTRAL CONDUCTOR FOR MULTI-WIRE RECEPTACLE BRANCH CIRCUITS. PROVIDE SPLICES IN OUTLET OR JUNCTION BOXES ONLY. PROVIDE UPDATED TYPE WRITTEN CIRCUIT DIRECTORY IN PLASTIC SLEEVE FOR EACH PANELBOARD AFFECTED BY THE WORK. PROVIDE U.L. APPROVED FIRE STOP SYSTEMS FOR PENETRATIONS THROUGH FIRE AND SMOKE PARTITIONS TO MAINTAIN THE RATING OF THE PARTITION. BOX-IN DEVICES ON FIRE/SMOKE PARTITIONS WITH FIRE RATED MATERIAL. PROVIDE "AS-BUILT" DRAWINGS TO THE OWNER AT CONTRACT CLOSEOUT. GUARANTEE WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER OWNER ACCEPTANCE. PERFORM ALL WORK IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (2014) AND 2015 INTERNATIONAL BUILDING CODE. SEE ARCHITECTURAL TITLE SHEET T001 FOR ADDITIONAL CODE REQUIREMENTS. CONTRACTOR SHALL COMPLY WITH AND MAINTAIN A COPY OF (2015) FIRE PROTECTION CODE AND NFPA 241-2000 "STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" ON SITE. NOTIFY CONSTRUCTION MANAGER, OWNER , FIRE DEPARTMENT, AND AUTHORITY HAVING JURISDICTION A MINIMUM OF SEVEN DAYS PRIOR TO ANY FIRE ALARM OR SPRINKLER SYSTEM SERVICE INTERRUPTION. PROVIDE FIRE WATCH IN ACCORDANCE WITH FIRE PREVENTION CODE (2012), PARAGRAPH 901.7. SERVICE INTERRUPTIONS SHALL BE CONFINED TO TIMES WHEN THE BUILDING IS NORMALLY UNOCCUPIED. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. SYMBOL DESCRIPTION FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, MOUNT STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN +96" AFF. STROBE CANDELA RATING AS INDICATED FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, MOUNT STROBE LENS NOT LESS THAN +80" AFF AND NOT MORE THAN + 96" AFF. STROBE CANDELA RATING AS INDICATED FIRE ALARM MANUAL PULL STATION, MOUNT +46" AFF FIRE ALARM SMOKE DETECTOR, CEILING MOUNT FIRE ALARM HEAT DETECTOR, CEILING MOUNT FIRE ALARM DUCT SMOKE DETECTOR FIRE ALARM TAMPER SWITCH FIRE ALARM FLOW SWITCH FIRE ALARM PRESSURE SWITCH FIRE ALARM MONITOR MODULE FIRE ALARM CONTROL MODULE FIRE ALARM VISIBLE NOTIFICATION APPLIANCE, CEILING MOUNT, STROBE CANDELA RATING AS INDICATED FIRE ALARM VISIBLE/AUDIBLE NOTIFICATION APPLIANCE, CEILING MOUNT, STROBE CANDELA RATING AS INDICATED MAGNETIC DOOR HOLD OPEN DEVICE FIRE ALARM LEGEND 1P SINGLE POLE 2P DOUBLE POLE 3P THREE POLE 1PH SINGLE PHASE 3PH THREE PHASE A AMPERES AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AMP AMPERE AUTO AUTOMATIC A/V AUDIO / VISUAL AWG AMERICAN WIRE GAUGE BFC BELOW FINISHED CEILING BFG BELOW FINISHED GRADE C CONDUIT CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CF COMPACT FLUORESCENT CKT CIRCUIT C/T CURRENT TRANSFORMER CU COPPER DEMO DEMOLITION DISC DISCONNECT ELEC ELECTRICAL ELTG EXTERIOR LIGHTING EM EMERGENCY EQ EQUIPMENT FA FIRE ALARM FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FC FOOT CANDLE FT FEET FVNR FULL VOLTAGE NON-REVERSING G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTING GFI GROUND FAULT INTERRUPTING GND GROUND HP HORSE POWER IAW IN ACCORDANCE WITH ILTG INTERIOR LIGHTING IN INCHES KCMIL KILO CIRCULAR MILLS KVA KILO VOLT AMPS KW KILO WATTS KWH KILO WATT HOURS LED LIGHT EMITTING DIODE LTG LIGHTING LTS LIGHTS MCC MOTOR CONTROL CENTER MISC MISCELLANEOUS MTD MOUNTED MTR MOTOR N NEUTRAL NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NO. NUMBER P/BD PANELBOARD PR PRESENT TO REMAIN PRI PRIMARY PVC POLYVINYL CHLORIDE PWR POWER RCPT RECEPTACLE RL RELOCATED SEC SECURITY SW SWITCH SWBD SWITCH BOARD TELECOM TELECOMMUNICATIONS TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS W/ WITH XFER TRANSFER XFMR TRANSFORMER ABBREVIATIONS S S J SF SF T C C S SD H TS FS PS M C F F F KP CR M PC M M G S H S H S H PC I I I S H RATED WALL LEGEND SYMBOL DESCRIPTION NON-RATED PARTITION NON-RATED SMOKE RESISTIVE PARTITION 1 HOUR FIRE BARRIER 1 HOUR SMOKE COMPARTMENT BARRIER 2 HOUR FIRE BARRIER 2 HOUR SMOKE COMPARTMENT BARRIER 2 HOUR FIRE BARRIER 3 HOUR SMOKE COMPARTMENT BARRIER CK ML ES EL 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 9/19/2017 4:38:13 AM LEGEND, SPECS, LIGHTING FIXTURE SCHEDULE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E001 2211 N FRONTAGE RD, VAIL, COLORADO 81657 LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER MODEL VOLTAGE LAMPS INPUT WATTS MOUNTING COMMENTS QTY TYPE WATTS C1 FEELUX ELS203000K-120 120 1 LED 20 W 20 COVE BALLROOM COVE THRU CONTROLS.VERIFY LENGTH OF RUN. PROVIDED BY CONTRACTOR C2 FEELUX ELS103000K-120 120 1 LED 10 W 10 COVE BALLROOM COVE THRU CONTROLS.VERIFY LENGTH OF RUN. PROVIDED BY CONTRACTOR C3 VOLT LIGHTING GROUP PH3K-24V 120 1 LED 10 W 10 MILL WORK PROVIDED BY CONTRACTOR. C4 VOLT LIGHTING GROUP PL3K-24V 120 1 LED 10 W 10 MILL WORK PROVIDED BY CONTRACTOR C5 PHILIPS LEDALITE 24G8LCGAG1611EB 120 1 LED 17 W SURFACE PROVIDED BY CONTRACTOR WITH END CAPS C6 COMMERCIAL ELECTRIC 54261141 120 1 LED 30 W 32 SURFACE PROVIDED BY CONTRACTOR F1 PHILIPS DAY-BRITE 2TG20L8302FS12FUNV 120 1 LED 23 W 72 RECESSED PROVIDED BY CONTRACTOR. F1E PHILIPS DAY-BRITE 2TG20L8302FS12FUNVEMLED 120 1 LED 23 W 25 RECESSED PROVIDED BY CONTRACTOR FP1 VOLT LIGHTING GROUP CUSTOM SQUARE "PUCK" 120 1 LED 11 W 15 RECESSED PROVIDED BY CONTRACTOR. CONTACT VOLT LIGHTING GROUP L1 COOPPER LIGHTING S23DR 2L30 SR 8 120 DD S1 120 1 LED 11 RECESSED PROVIDED BY CONTRACTOR. L1E COOPPER LIGHTING S23DR 2L30 SR 8 120 DD S1 120 1 LED 11 RECESSED PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP LTG-401 TECH LIGHTING PETRONA 700PTNA 120 22 LED 100 W 100 PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. LTG-402 EUROFASE 20446-024 120 1 GU10 50 W 50 PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE LAMPING. LTG-403 120 22 W PENDANT SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE LAMPING. LTG-600 120 0 W SUPPLIED BY OTHERS AND INSTALLED BY CONTRACTOR. CONTRACTOR TO ALSO PROVIDE LAMPING. P1 COOPER LIGHTING S23DIP 2L30 TGRID 8 DD S1EM S93S 120 1 LED 11 PENDANT PROVIDED BY CONTRACTOR WITH REMOTE MOUNT EMERGENCY BACK-UP R1 PHILIPS LIGHTOLIER P6RD10NZ10UVB / P6RD830VB / P6RDCC 120 1 LED 7 W 10 RECESSED PROVIDED BY CONTRACTOR R1E PHILIPS LIGHTOLIER P6RD10NZ10UVBEM/ P6RD830VB / P6RDCC 120 1 LED 7 W 10 PENDANT PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP R2 PHILIPS LIGHTOLIER P6RD15NZ10UVB / P6RD830VB / P6RDCC 120 1 LED 12 W 16 RECESSED PROVIDED BY CONTRACTOR R2E PHILIPS LIGHTOLIER P6RD15NZ10UVBEM / P6RD830VB / P6RDCC 120 1 LED 12 W 16 RECESSED R3 PHILIPS LIGHTOLIER P6RD20NZ10UVB / P6RD830VB / P6RDCC 17 W R3E PHILIPS LIGHTOLIER P6RD20NZ10UVEMB / P6RD830VB / P6RDCC 120 1 LED 17 W 16 RECESSED PROVIDED BY CONTRACTOR WITH EMERGENCY BACK-UP R4 PHILIPS LIGHTOLIER CP4RN / CP4RBO7830W 120 1 LED 11 W 11 RECESSED PROVIDED BY CONTRACTOR S1 SPA AREA WALL SCONCE SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL. S2 PUBLIC RESTROOMS SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL. S3 GUESTROOM LOFTS SUPPLIED BY OTHER 120 1 LED 10 W 15 SURFACE CONTRACTOR TO VERIFY HEIGHT AND INSTALL. SR1 NICOR D-SERIES DLR56 2709-120-3K-BL 120 1 LED 11 W 15 RECESSED PROVIDED BY CONTRACTOR FIXTURE TO BE BLACK AND DIMMING. SR2 LITHONIA 5G1MB LED M6 120 1 LED 11 W 15 RECESSED WALL WASHING, BLACK AND DIMMING. PROVIDED BY CONTRACTOR. X1 DUALLITE HCX X2 LITHONIA AFN DB X3 LITHONIA AFN DB FWD 0 W 1 8/25/2016 FOR CONSTRUCTION SET 4 11/07/2016 ASI #2 10 9/15/17 CCD-06 09/07/2017 201709/0 10/04/17