HomeMy WebLinkAboutB16-0254_E101_signed_1506372180.pdfSD
F
F
F
F
FFF
F
SD
F
J
F
F
SB
SB SB SB F
J
F
D
D Dv D Dv D v
DDv
DD D D D
DDDDDD
J
F
F F K KKJ
KTTT
epo
F
F
K
F
F
F
J
MENS
ROOM
WOMENS
ROOM
MAINTENANCE
CURRENT
FITNESS
AREA
N.I.C.
N.I.C.
TIMBER FRAME ENTRY
STRUCTURE AND ROOF
TO BE REMOVED
26.1
26.10
26.11
TYPICAL
26.12
26.12
26.2
26.2
26.13
26.3
26.14
26.3
26.14
26.12
26.2
26.3
26.14
EXISTING TO
REMAIN PANEL
26.3
26.14
26.12
26.3
26.12
26.14
RECEPTION DESK
TO BE REMOVED
26.3 26.3
26.12 26.12
26.15 26.15
26.3
26.3
26.15
26.16
BENCH SEATING TO
BE REMOVED
26.3
26.17
26.3
26.14
26.12
26.3
26.14
26.3
26.14
26.12
RECEPTION DESK
TO BE REMOVED
26.3
26.14
26.12
26.5
26.5
26.18
26.12
THERAPY /
SPA
26.5
26.12
26.18
26.5
26.18
26.5
26.18
26.12
26.5
26.5
26.12
26.12
26.15
26.3
26.19
26.19
26.20
26.20
HOT TUB TO
BE REMOVED
26.3
26.2
26.21
26.22
26.3
26.14
26.12
SOFFIT TO BE
REMOVED
26.5
26.15
26.2
26.12
26.15
26.5
TYPICAL
26.24
26.23
COVE MOUNTED SPOT
LIGHTING TYPICAL
CENTRAL DATA AND
PHONE DEMARC
EQUIPMENT TO BE
RELOCATED BY OTHERS
26.3
26.5
26.5
26.5
26.27
26.28
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN
PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
9/19/2017
4:38:19 AM
DEMOLITION PLAN -
1st FLOOR
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/25/16 -
CONSTRUCTION
DOCUMENTS
E101
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/8" = 1'-0" DRAWING REF: E401a
6APOWER DEMOLITION PLAN - 1st FLOOR
KEYNOTES
26.18 DISCONNECT AND REMOVE RECEPTACLES AND WIRE BACK TO REUSABLE
LOCATION. CIRCUIT TO BE REUSED FOR NEW WORK IN THIS SAME AREA.
26.19 DISCONNECT AND REMOVE 200A SAUNA STEAM GENERATOR AND ALL
ASSOCIATED EQUIPMENT BACK TO SOURCE. CIRCUIT TO BE REUSED FOR NEW
42P 120/208 PANEL 'LLD'. CONTRACTOR TO VERIFY CIRCUIT TO REMAIN SIZE.
26.20 DISCONNECT AND REMOVE HOT TUB PUMPS, ALL ASSOCIATED EQUIPMENT AND
CONTROLS. EQUIPMENT AND CIRCUITS TO BE EXTENDED AND REUSED FOR NEW
HOT TUB RELOCATION.
26.21 DISCONNECT AND REMOVE HVAC DISCONNECTS FOR RELOCATION AS NEEDED.
26.22 DISCONNECT AND REMOVE ABANDONED MISCELLANEOUS ELECTRICAL DEVICES /
CONDUIT/EQUIPMENT AND WIRE BACK TO SOURCE.
26.23 DISCONNECT AND REMOVE AHU FOR REPLACEMENT WITH NEW UNIT.
CONTRACTOR TO VERIFY BREAKER AND WIRE SIZES AND REPLACE AS
REQUIRED.
26.24 DISCONNECT AND REMOVE INDOOR AIR HANDLERS, OUTDOOR CONDENSING
UNITS, DISCONNECTS AND WIRE BACK TO SOURCE. CIRCUITS TO BE REUSED
FOR NEW VAV BOXES. TYPICAL OF (3) UNITS.
26.27 DISCONNECT AND REMOVE CIRCUIT TO MAKE UP AIR UNIT ON ROOF BACK TO
SOURCE.
26.28 DISCONNECT AND REMOVE CIRCUIT FROM ROOF TOP UTILITY FAN BACK TO
REUSABLE LOCATION.
26.1 DISCONNECT AND REMOVE LIGHTING, CONDUIT AND WIRE BACK TO REUSABLE
LOCATION. LIGHTING CIRCUIT TO BE REUSED FOR NEW UNDER CANOPY
LIGHTING.
26.2 DISCONNECT AND REMOVE LIGHTING. CIRCUIT TO BE REUSED FOR NEW
LIGHTING IN SAME AREA. LIGHTING CIRCUITS TO BE ROUTED THRU NEW
LIGHTING CONTROLS / PANEL.
26.3 DISCONNECT AND REMOVE ALL LIGHTING, SWITCHING AND WIRE BACK TO
SOURCE. LIGHTING CIRCUITS TO BE ROUTED THRU NEW LIGHTING CONTROLS /
PANEL.
26.5 DISCONNECT AND REMOVE LIGHTING AND SWITCHING. REMOVE WIRE BACK TO
REUSABLE LOCATION. CIRCUIT TO BE REUSED FOR NEW LIGHTING WORK IN THIS
SAME AREA.
26.10 DISCONNECT AND REMOVE RECEPTACLE, CONDUIT AND WIRE BACK TO
REUSABLE LOCATION.
26.11 DISCONNECT AND REMOVE INFRARED HEATER AND WIRE BACK TO REUSABLE
LOCATION. HEATER AND CIRCUIT TO BE REUSED FOR NEW VALET LOCATION.
26.12 DISCONNECT AND REMOVE FIRE ALARM DEVICES AND WIRE BACK TO REUSABLE
LOCATION. DEVICES TO BE REUSED FOR NEW WORK.
26.13 DISCONNECT AND REMOVE 100A MCB PANELBOARD. REMOVE FEEDER BACK TO
REUSABLE LOCATION. PANEL TO BE RELOCATED AT NEW KITCHEN WALL FOR
NEWLY CONFIGURED BAR AREA. SEE POWER DRAWING E121 FOR NEW PANEL
LOCATION AND DESIGNATION.
26.14 DISCONNECT AND REMOVE ALL RECEPTACLES, DATA OUTLETS AND WIRE BACK
TO SOURCE.
26.15 DISCONNECT AND REMOVE RECEPTACLES AND WIRE BACK TO SOURCE.
26.16 DISCONNECT AND REMOVE RECESSED FLOOR BOXES, CONDUIT AND WIRE BACK
TO POINT OF REUSE FOR NEW RECESSED FLOOR BOXES.
26.17 DISCONNECT FIRE PLACE FOR DEMOLITION / REMOVAL. CIRCUIT TO BE REUSED
FOR NEW FIRE PLACE LOCATION. SEE E121 FOR ADDITION INFORMATION.
GENERAL PLAN NOTES
1. REMOVE ALL SPEAKERS, SWITCHING AND ALL ASSOCIATED SOUND SYSTEM EQUIPMENT
FROM THERAPY / SPA AND RETURN TO OWNER FOR REUSE IN NEW THERAPY / SPA
LOCATION.
1 8/25/2016 FOR CONSTRUCTION SET
10 9/15/17 CCD-06
09/07/2017
201709/0
09/25/17