Loading...
HomeMy WebLinkAboutB16-0254_E401a_signed_1507144320.pdfJ J J J J J J J J J J M M kp J J J J CR DL CR 26.32 LD- 1 SKI BOOT REMOVAL AREA 110 VESTIBULE 101 LOBBY LOUNGE WITH CONNECTIVITY ZONE 102 ? ? CHECK-IN 107 LOBBY BAR 103 TYPICAL OF (3) R3 R2E R1E R2 R2 R2 R1E R2 R2 R2 R2 R3 R3 R3 R3 R3 R3 R3 R3 R3 R3E R3 R3E R3 R3 R3 R3E R3 R3 LD- 3 X1 CONNECT TO CORRIDOR LIGHTING CIRCUIT 26.43 26.44 R2 TYPICAL 26.45 26.43 LD- 5 LD- 4 LD- 8 R4 R4 6A E401a C3 TYPICAL ACROSS TOP 26.35 LD- 2 LD- 6 26.58 26.58 TYPICAL TYPICAL OF (3) BOH MASTER LIGHTING KEYPAD R4 R4 1 E401a C4 C4 26.38 26.37 26.33 LTG-401 LTG-403 LTG-402 X2 X2 X3 X2 26.61 TYPICAL C5 X3 +96" R2E R2E 26.62 X2 X1 R3 MAIN FLOOR 100' - 0" 2ND FLOOR 114' - 2" 02_SECOND FLOOR -1 112' - 0" 01_MAIN FLOOR 100' - 0" 02_SECOND FLOOR -1 112' - 0" 2ND FLOOR - REFLECTED CEILING PLAN 114' - 2" C4 C3 26.35 26.36 MAIN FLOOR 100' - 0" 2ND FLOOR 114' - 2" O 02_SECOND FLOOR -1 112' - 0" 01_MAIN FLOOR 100' - 0" 02_SECOND FLOOR -1 112' - 0" 2ND FLOOR - REFLECTED CEILING PLAN 114' - 2" FP1 26.60 TYPICAL OF (80) 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 9/19/2017 4:39:09 AM ENLARGED FLOOR PLAN - LOBBY/LOUNGE/BAR LIGHTING THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E401a 2211 N FRONTAGE RD, VAIL, COLORADO 81657 SCALE: 1/4" = 1'-0" DRAWING REF: E111 4AENLARGED FLOOR PLAN - LOBBY/LOUNGE/BAR KEYNOTES 26.32 PROVIDE OCCUPANCY/VACANCY SWITCHING EQUAL TO LUTRON MAESTRO MS-Z101. 26.33 PROVIDE RECESSED JUNCTION BOXES AND LIGHTING CIRCUIT THRU NEW LIGHTING CONTROLS. INSTALL PENDANT LIGHTING SUPPLIED BY OTHERS AND MAKE ALL FINAL CONNECTIONS. 26.35 PROVIDE LED TAPE ACROSS TOP OF BAR MILLWORK EQUAL TO FIXTURE LISTED IN SCHEDULE. SEE MILLWORK DRAWINGS A606 AND A607 FOR ADDITIONAL INFORMATION. FIELD COORDINATE SWITCHING. 26.36 PROVIDE LED TAPE TO UNDERSIDE OF BAR COUNTER TOP MILLWORK EQUAL TO FIXTURE LISTED IN SCHEDULE. SEE MILLWORK DRAWINGS A606 AND A607 FOR ADDITIONAL INFORMATION. INFORMATION. FIELD COORDINATE SWITCHING. 26.37 PROVIDE POWER TO FOCAL LIGHTING. PROVIDE 16'-0" OF LENGTH LIGHTING EQUAL TO FIXTURE SCHEDULE AT 14'-6" AFF. LIGHTING TO BE SWITCHED BT BREAKER AT PANEL. 26.38 PROVIDE LED TAPE AT REGISTRATION DESK MILL WORK. SEE DRAWING A605 FOR ADDITIONAL INFORMATION. FIELD COORDINATE SWITCHING. 26.43 CONNECT AHEAD OF SWITCHING AS NIGHT LIGHT. 26.44 PROVIDE CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. 26.45 CONNECT TO AVAILABLE 20A 1P 120V CIRCUIT MADE AVAILABLE DURING DEMOLITION OR PROVIDE MATCHING AIC 20A 1P CIRCUIT BREAKER IN AVAILABLE SPACE OF EXISTING PANELBOARD AS NEEDED. FIELD VERIFY PANEL DESIGNATIONS AND CIRCUIT AVAILABILITY. 26.58 PROVIDE JUNCTION BOXES AND LIGHTING CIRCUIT THRU NEW LIGHTING CONTROLS. INSTALL PENDANT LIGHTING SUPPLIED BY OTHERS AND MAKE ALL FINAL CONNECTIONS. 26.60 PROVIDE RECESSED LED SQUARE PUCK LIGHTS AT FIREPLACE FACADE AS MANUFACTURED BY THE VOLT LIGHTING GROUP. CONTACT BILL AT 800-789-3810. SEE ARCHITECTS DRAWING A401D FOR ADDITIONAL INFORMATION. 26.61 PROVIDE EGRESS LIGHTING EQUAL TO FIXTURE LISTED IN FIXTURE SCHEDULE ON EXPOSED ROOF TRUSS AT @ 21'-0" AFF. PAINT CONDUIT TO MATCH. 26.62 EXTEND AND CONNECT TO EXTERIOR LIGHTING CIRCUIT. SCALE: 1/4" = 1'-0" DRAWING REF: E401a 6AENLARGED BAR LIGHTING DETAIL Notes: Total Est. Demand... 17 A Total Conn. Current: 17 A Power 3900 VA 100.00% 3900 VA Total Est. Demand: 6186 VA Other 0 VA 0.00% 0 VA Total Conn. Load: 6186 VA Lighting 2286 VA 100.00% 2286 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 23 A 29 A 5 A Total Load: 2514 VA 3119 VA 552 VA 19 20 17 18 15 16 13 14 11 12 9 CORRIDORS 140A, 140, 140B LTS 20 A 1 662... 312... 1 20 A PREFUNCTION 152 LIGHTING 10 7 ELEV LOBBY 140A, 107C LIGHTS 20 A 1 445... 465... 1 20 A LOBBY LOUNGE LIGHTING 8 5 VESTIBULE 101 LIGHTING 20 A 1 52 VA 500... 1 20 A FRONT DESK FOCAL WALL LIGHTS 6 3 LBY/LOUNGE RECESSED LTS 20 A 1 624... 152... 1 20 A CHECK-IN DESK LIGHTNIG 4 1 LBY/LOUNGE PENDANT LIGHTING 20 A 1 150... 104... 1 20 A SKI BOOT REMOVAL AREA 110 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: Surface Wires: 4 Mains Rating: 100 A Supply From: Phases: 3 Mains Type: Location: LUGGAGE ROOM 118 Volts: 120/208 Wye A.I.C. Rating: Branch Panel: LD 1 8/25/2016 FOR CONSTRUCTION SET 4 11/07/2016 ASI #2 6 1/09/2017 CCD-03 10 9/15/17 CCD-06 LOBBY DIMMING SCHEDULE SCALE: 1/4" = 1'-0" DRAWING REF: E401a 1ENLARGED FIREPLACE LIGHTING DETAIL 09/07/2017 201709/0 10/04/17