HomeMy WebLinkAboutB16-0254_E407_signed_1506372240.pdf3 3 G D D D D D D G G J J J J J J J J KITCHEN 151 DISHWASHING 106 B K K- 14 26.65 26.66 26.67 B K K- 17 height height 34" 68" 65" KITCHEN 151 K- 1 K- 5 K- 9 34" K- 13 K- 15 K- 19 K- 21 K- 23 K- 25 K- 27 K- 29 K- 31 K- 33 K- 35 K- 37 K- 39 K- 28,30 K- 47,49,51 K- 41,43,45 26.114 26.115 26.116 B- 12 +44" B- 14 K- 53 1 A 2 3 4 5 6 A B C D E 1 3 4 5 6 2 COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN CONSENT. B C D E DRAWING NO. P.O. BOX 400, RICHMOND, VA 23218-0400 DRAWING TITLE ISSUE PROJECT OWNER ® 9/19/2017 4:39:18 AM ENLARGED KITCHEN DETAILS AND PANELBOARD SCHEDULE THE WIDEWATERS GROUP 2.160036.0 DOUBLETREE VAIL, CO CONVERSION GUESTROOMS & PUBLIC SPACES RENOVATION 08/25/16 - CONSTRUCTION DOCUMENTS E407 2211 N FRONTAGE RD, VAIL, COLORADO 81657 12 9/15/17 CCD-07 KEYNOTES 26.65 PROVIDE 2X4 LAY-IN LIGHTING EQUAL TO LITHONIA 2ALT4 5000LM MVOLT. 26.66 PROVIDE 2X2 LAY-IN LIGHTING EQUAL TO ETI 54309141. 26.67 PROVIDE 1X2 LAY-IN LIGHTING EQUAL TO PIXI FLT12R27MD1622A. 26.114 PROVIDE SINGLE POINT CONNECTION TO DISH MACHINE CONTROL PANEL. FEED WITH (3) #10, (1) #10 GND-3/4" CONDUIT AND FLEXIBLE CONNECTION. 26.115 PROVIDE SINGLE POINT CONNECTION TO DISH MACHINE BOOSTER HEATER. FEED WITH (3) #3, (1) #8 GND- 1 1/4"C. 26.116 PROVIDE POWER TO MENU BOARD. VERIFY CONNECTION TYPE AND HEIGHT IN FIELD. SCALE: 3/8" = 1'-0" DRAWING REF: E111 3AENLARGED KITCHEN LIGHTING PLAN SCALE: 3/8" = 1'-0" DRAWING REF: E1216AENLARGED KITCHEN POWER PLAN Notes: Receptacle 2520 VA 100.00% 2520 VA Total Est. Demand... 151 A Power 10616 VA 100.00% 10616 VA Total Conn. Current: 151 A Other 1580 VA 100.00% 1580 VA Total Est. Demand: 54517 VA Lighting 369 VA 100.00% 369 VA Total Conn. Load: 54517 VA HVAC 9126 VA 100.00% 9126 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 143 A 147 A 165 A Total Load: 17149 VA 17578 VA 19790 VA 53 KITCHEN FIRE SUPPRESSION 20 A 1 500... 0 VA 1 20 A SPARE 54 51 720... 0 VA 1 20 A SPARE 52 49 720... 0 VA 1 20 A SPARE 50 47 COOLER CONDENSING UNIT 15 A 3 720... 0 VA 1 20 A SPARE 48 45 816... 0 VA 1 20 A SPARE 46 43 816... 0 VA 1 20 A SPARE 44 41 FREEZER CONDENSING UNIT 15 A 3 816... 42 39 COOLER EVAPORATOR COIL 15 A 1 528... 40 37 KITCHEN 151 WALK-IN FREEZER 15 A 1 120... 38 35 KITCHEN 151 WALK-IN COLLER 15 A 1 120... 36 33 KITCHEN 151 RECEPTACLE 20 A 1 180... 34 31 KITCHEN 151 RECEPTACLE 20 A 1 180... 32 29 KITCHEN 151 RECEPTACLE 20 A 1 180... 129... 30 27 KITCHEN 151 RECEPTACLE 20 A 1 180... 129... 2 20 A FREEZER EVAPORATOR COIL 28 25 KITCHEN 151 RECEPTACLE 20 A 1 180... 800... 26 23 KITCHEN 151 RECEPTACLE 20 A 1 180... 800... 24 21 KITCHEN 151 RECEPTACLE 20 A 1 180... 800... 3 90 A DISHMACHINE BOOSTER HEATER 22 19 KITCHEN 151 RECEPTACLE 20 A 1 180... 210... 20 17 KITCHEN 151 HEAT LAMP / TABLE 20 A 1 158... 210... 18 15 KITCHEN 151 RECEPTACLE 20 A 1 360... 210... 3 35 A DISHMACHINE 16 13 KITCHEN 151 RECEPTACLE 20 A 1 180... 369... 1 20 A KITCHEN LIGHTING 14 11 SHUNT TRIP -- -- 0 VA 210... 12 9 KITCHEN 151 RECEPTACLE 20 A 1 180... 210... 10 7 SHUNT TRIP -- -- 0 VA 210... 3 35 A RTU-A1 LOCATED ON ROOFTOP 8 5 KITCHEN 151 RECEPTACLE 20 A 1 180... 940... 6 3 SHUNT TRIP -- -- 0 VA 940... 4 1 KITCHEN 151 RECEPTACLE 20 A 1 180... 940... 3 15 A MAU-1 LOCATED ON ROOFTOP 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure: Type 1 MCB Rating: Mounting: Surface Wires: 4 Mains Rating: 200 A Supply From: LLF Phases: 3 Mains Type: Location: KITCHEN 151 Volts: 120/208 Wye A.I.C. Rating: Branch Panel: K 09/07/2017 201709/0 09/25/17