HomeMy WebLinkAboutB16-0254_K302 - ENLARGED KITCHEN ELECTRICAL ROUGH IN PLAN_1507147357.pdfG
G
G D
D D
D
D D
KEY TO SYMBOLS AND ABBREVIATIONS
POUNDS PER SQUARE INCH
CUBIC FEET PER MINUTE
BRANCH TO CONNECTION
BRITISH THERMAL UNITS
PSI
AFF
BTU
CFM
BTC
ABOVE FINISH FLOOR
W
IW
FD
SR
FFD
FS
S
G
HW
CW
WASTE
STEAM RETURN
INDIRECT WASTE
FLOOR DRAIN
FUNNEL FLOOR DRAIN
FLOOR SINK
STEAM
COLD WATER
HOT WATER
GAS
SHOP WIRING
FIELD WIRING
CORD AND PLUG
DISCONNECT SWITCH
ELECTRIC CONNECTION EC
SWITCH
HORSEPOWER
KILOWATTS
DUPLEX RECEPTACLE
SINGLE RECEPTACLE
ELECTRIC LIGHT
PHASE
VOLTS
CYCLES
JUNCTION BOX
S
0
HP
KW
JB
V
CY
PH
SR
DR
REFRIGERATED PREP TABLE
DESCRIPTION
E-12
ITEM
4
E-5
E-6
E-7
E-8
E-9
E-11
E-10
KEY
E-2
E-1
E-4
E-3
ELECTRICAL ROUGH-IN KEY
1 120 1/4
PH. VOLTS HP KW
6.6 DR 12"
CONN. AMPS HT.
120
EVAPORATOR COIL (COOLER)
COMPRESSOR (COOLER)
WALK-IN COOLER(LIGHTS)
29.3
29.1
29 1 15.0 JB 108"
108"
JB 208 3 1.5
JB 120 1 4.4
(VERIFY W/SHOP DRAWINGS)
(VERIFY W/SHOP DRAWINGS)
(LOCATED ON ROOF BY MECH. CONTR.)
120 1 20.0 108"
JB EXHAUST HOOD
120 1 4" JB 5 HEAT LAMPS
18 EXHAUST HOOD (LIGHT SWITCH)
18 EXHAUST HOOD (FAN SWITCH)
54"
54"
THIS PLAN SHOWS ELECTRICAL REQUIREMENTS FOR FOOD SERVICE EQUIPMENT
EQUIPMENT. ELECTRICAN TO FURNISH ALL TRIM ACCESSORIES, DISCONNECTS,
ELECTRICAN TO ACCOMODATE ALL PREVAILING LOCAL ELECTRICAL CODES AS REQUIRED.
ELECTRICAN TO INSTALL AND INTERWIRE HOOD OR VENTILATOR VAPOR-PROOF
CONTRACTOR MUST MAKE ALLOWANCES FOR ANY APPLIED FINISH ADHERED TO
ELECTRICAN TO DO ALL ROUGHING AND MAKE ALL FINAL CONNECTIONS TO
CONTRACTORS,SWITCHES, RELAYS, ETC. AS REQUIRED.
ALL CONVENIENCE OUTLETS TO BE MOUNTED HORIZONTALLY.
ELECTRICAN TO FURNISH AND INSTALL CONDUITS AND SLEEVES FOR
ALL WIRING AND CONDUIT TO BE CONCEALED.
LIGHTS SUPPLIED BY KITCHEN EQUIPMENT CONTRACTOR.
ALL DIMENSIONS FOR CONNECTIONS TO THE FIXTURES SHOULD COME OUT OF
THE WALL OR PARTITION AT REAR. ALL DIMENSIONS ARE FROM FINISHED
CONNECTIONS FROM ALL HOODS TO EXHAUST SYSTEM.
AS REQUIRED FOR WALK-IN FREEZER.
ELECTRICAN TO INSTALL AND INTERWIRE COMPRESSOR AND EVAPORATOR
FLOOR, WALL OR COLUMNS.
REFRIGERATION AND SODA LINES.
ONLY. FOR ALL OTHER REQUIREMENTS, SUCH AS INTERIOR AND EXTERIOR
LIGHTING, TOILET FACILITIES, EXHAUST FANS, WALL OUTLETS AND
TELEPHONES, SEE ARCHITECTS PLAN.
ELECTRICAL NOTES:
120 1 15.0 12"
DR 7 HEATED PROOFER CABINET
120 1 12.0 DR 10 STOCK POT KETTLE
208 1 13.7 4"
DR 15 REFRIGERATED PREP TABLE
1.45
DOUBLE CONVECTION OVEN
17 1 (2)120
1/2
9.8 DR 24"/48"
18
3/4
REFRIGERATED EQUIPMENT STAND 1/5 DR 12"
2
E-13
E-14
E-15
120
EVAPORATOR COIL (FREEZER)
COMPRESSOR (FREEZER)
WALK-IN FREEZER(LIGHTS)
29.4
29.2
29 1 15.0 JB 108"
108"
JB 208 3 2.0
JB 208 1 12.4
(VERIFY W/SHOP DRAWINGS)
(VERIFY W/SHOP DRAWINGS)
(LOCATED ON ROOF BY MECH. CONTR.)
E-16
E-17
120 1 10.0 108" JB 41 FIRE SYSTEM
E-18
(VERIFY W/SHOP DRAWINGS)
(VERIFY W/SHOP DRAWINGS)
(VERIFY W/SHOP DRAWINGS)
(VERIFY W/SHOP DRAWINGS)
E-19
E-20
E-21
E-22
E-23
E-24
E-25
E-26
120 1 20.0 48"
DR CONVENIENCE OUTLET E-27
120 1 20.0 12"
DR CONVENIENCE OUTLET
PIZZA PREP REFRIGERATOR 20 1 120 1/2 13.0 DR 12"
DISHMACHINE 208 3 5.0 JB 14"
31
1 120 5.7
2.2 (EC TO INTERWIRE (2) UNITS)
1.8
(EC TO PROVIDE PENDANT CORD DN FROM CLG TO 36" AFF)
WORKTOP FREEZER 25 1 120 1/3 6.1 DR 12"
ICE MACHINE 27 1 120 15.2 JB 60"
31.3
DISHMACHINE (BOOSTER HEATER) 208 3 24.0 JB 14"
31
120 1 10.0 48"
JB 36 PIZZA OVEN (CONTROLS)
120 1 20.0 48"
DR DIGITAL MENU BOARD 38
E-28
208 1 10.2 JB
EXHAUST HOOD (EXHAUST FAN)
EXHAUST HOOD (MUA UNIT)
(LOCATED ON ROOF BY MECH. CONTR.)
(LOCATED ON ROOF BY MECH. CONTR.)
208 1 6.1 JB
3.0
2.0
18
E
19
E
10
E
25
E
26
E
9
E
2'-0"
13
E
27
E
5'-4"
27
E
1'-6"
12
E
1'-6"
27
E
2'-0"
11
E
5'-6"
27
E
2'-0"
27
E
3'-0"
4'-6"
2'-6"
2
E
4
E
10'-0"
4'-6"
3
E
2'-0"
6
E
1'-6"
7
E
27
E
12"
3'-0"
4'-0"
1
E
22
E
8
E
6'-0"
6'-6"
2'-0"
5
E
6
E
12" 2'-0"
2'-0"
2'-0"
1'-6"
17
E
16
E
15
E
14
E
1'-4"
2'-0"
20
E
21
E
5'-4"
23
E
2'-6"
24
E
1 A 2 3 4 5 6 A B C D E
1
3 4 5 6 2
COPYRIGHT 2016 BASKERVILL. USE OF THIS WORK IN WHOLE OR
IN PART IS FORBIDDEN WITHOUT EXPRESSED WRITTEN
CONSENT.
B C D E
DRAWING NO.
P.O. BOX 400, RICHMOND, VA 23218-0400
DRAWING TITLE
ISSUE
PROJECT
OWNER
®
9/18/2017
10:58:01 AM
ENLARGED KITCHEN
ELECTRICAL ROUGH
IN PLAN
THE WIDEWATERS
GROUP
2.160036.0
DOUBLETREE VAIL,
CO CONVERSION
GUESTROOMS &
PUBLIC SPACES
RENOVATION
08/04/2017 -
CONSTRUCTION
DOCUMENTS
K302
2211 N FRONTAGE
RD, VAIL, COLORADO
81657
SCALE: 1/4" = 1'-0" DRAWING REF: K100
3AENLARGED KITCHEN ELECTRICAL ROUGH-IN PLAN
10/04/17