HomeMy WebLinkAboutB17-0027_A-201_1496780460.pdf1
CONSTRUCTION KEY NOTES:
NEW BUILT-IN CLOSET SYSTEM.
NEW VANITY AND LAVATORY.
NEW WATER CLOSET IN NEW LOCATION AS SHOWN.
CONTRACTOR SHALL GPR AND INVESTIGATE SLAB PRIOR TO
CHIPPING FOR NEW OR RELOCATED PLUMBING.
REUSE EXISTING WASHER/DRYER.
NEW COUNTERTOPS, CABINETRY, SINK AND FAUCET.
NEW RANGE, WOLF MODEL #DF486G
NEW CUSTOM RANGE HOOD WITH BEST PK2245 LINER AND
INTERNAL BLOWER, RE: MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
NEW REFRIGERATOR, SUBZERO MODEL #IC-30R-LH
NEW WINE COOLER, SUBZERO MODEL #IW-18-LH
NEW FREEZER DRAWERS, SUBZERO MODEL #ID-30FI
NEW DISHWASHER, ASKO MODEL #D5526XXLFI
NEW MICROWAVE, WOLF MODEL #MS24
NEW COUNTERTOPS, SINK, CABINETRY AND FINISHES.
NEW FIREPLACE, TOWN AND COUNTRY MODEL # TCWS.54CE3,
REUSE EXISTING FLUE AND REPOSITION GAS SUPPLY AS REQUIRED.
COORDINATE EXACT LOCATION WITH INTERIOR DESIGNER.
NEW SHOWER AND LAVATORIES. CONTRACTOR SHALL GPR AND
INVESTIGATE SLAB PRIOR TO CHIPPING FOR NEW OR RELOCATED
PLUMBING.
NEW VANITY.
NEW WATER CLOSET IN SAME LOCATION.
NEW FINISHES THROUGHOUT.
NEW ELECTRIC FLOOR HEAT MAT, RE: PLUMBING AND ELEC.
DRAWINGS FOR ADDITIONAL INFORMATION.
NEW LINEN CLOSET.
NEW EXTERIOR LOUVER FOR RANGE HOOD EXHAUST
PER DRB APPROVAL #DRB17-0090.
NEW EXTERIOR LOUVER FOR MAKE-UP AIR UNIT INTAKE
PER DRB APPROVAL #DRB17-0090.
RECESSED SHOWER SHELVING, RE: INTERIOR DESIGN
ELEVATIONS FOR ADD'L. INFORMATION
CONSTRUCTION GENERAL NOTES:
1. INSTALL NEW FLOORING THROUGHOUT, RE: I.D. DRAWINGS FOR
MATERIALS AND LIMITS. INSTALL IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS.
2. CONTRACTOR SHALL USE 5/8" TYPE "X" DRYWALL THROUGHOUT.
DRYWALL FINISHES SHALL MATCH EXISTING; I.E.-LEVEL 4 FINISH AS
DEFINED BY THE GYPSUM ASSOCIATION GA-214-96.
3. AT ALL RATED WALL ASSEMBLIES AS INDICATED ON PLANS,
CONTRACTOR SHALL REPAIR/MAINTAIN RATING INTEGRITY AS
REQUIRED.
4. UNLESS OTHERWISE NOTED AT NEW DOOR LOCATIONS, JAMB SHALL
BE LOCATED 6" FROM HINGE SIDE.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
19
20
21
22
ENTRY
100
DINING
ROOM
102
KITCHEN
101
MASTER
BATH
106
MASTER
BED
105
BATH 2
111
BED 2
110
LIVING
ROOM
104
POWDER
114
SKI
CLOSET
115
MUD ROOM
113
BED 3
108
BATH 3
109
SITTING
103
HALLWAY
112
HALLWAY
107
1
1
1
1
1
2
2
3
3
100.1
115.1
105.1
105.2
106.1
106.3
106.2
109.1
108.1
108.2
110.2
110.1
111.1
113.1
112.1
114.1
4
5
8
9
6
7
10
12 11
13
14
CL
CL
ALIGN
ALIGN
15
15
16 16
17 17
18
18
18
18
19
19
19
19
C
L
ALIGN
ALIGN
CL
CL
CL
ALIGN
ALIGN
ALIGN
ALIGN
CL
NEW EXTERIOR LOUVERS PER
DRB APPROVAL #DRB17-0090
20
21
ALIGN
22
22
22
WALL LEGEND:
HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D.
HATCH INDICATES NEW WALL CONSTRUCTION. DIMENSIONS ARE TO FINISH FACE OF GYPSUM BOARD U.O.N. INTERIOR WALL CONSTRUCTION SHALL BE 20GA
CFMF U.O.N.
SCALE: 1/4" = 1'-0"
1
FLOOR PLAN
FLOOR PLAN
04 OF 22
A-201
ISSUE DATE
UNIT 9203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
VK
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
VK
UNIT 9203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Tim & Nancy Buese
Unit 9203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Duet Design Group, LLC
901 ACOMA SUITE 200
DENVER, CO 80204
t. 303-783-9327
miranda@duetdesigngroup.com
MECH/PLUMBING ENGINEER:
Rader Engineering
PO BOX 8610
AVON, CO 80620
t. 970-845-7910
BryanH@raderengineering.com
ELECTRICAL ENGINEER:
C3S Incorporated
3212 WEST 45TH AVENUE
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
LIGHTING DESIGN:
186 Lighting Design Group, Inc.
1200 BANNOCK STREET
DENVER, CO 80204
t. 303-534-5350
gmackell@186group.com
KITCHEN DESIGN:
exquisite kitchen design
601 SOUTH BROADWAY SUITE F
DENVER, CO 80209
303-282-0382
mikalo@myekdesign.com
16-27
FOR PERMIT
5/5/2017
2/22/17
1
FOR CONSTRUCTION
5/5/17
1
1
1
1
1
1
1
1
1
1
1
1
1
1
06/06/17