CEILING PLAN DEMO KEY NOTES:
EXISTING DECORATIVE FIXTURE TO BE REPLACED IN SAME LOCATION.
EXISTING SWITCH BANK/KEYPAD/CONTROL LOCATION TO BE
REMOVED, RELOCATED AND/OR RECONFIGURED RE: REFLECTED
CEILING PLAN 1/A-301 AND LIGHTING PLAN L-100.
NOT USED.
EXISTING SUPPLY DIFFUSER TO BE RELOCATED AND/OR
RECONFIGURED AS SHOWN ON 1/A-301.
EXISTING RETURN AIR SLOT TO BE REMOVED/ RECONFIGURED AS
REQUIRED, RE: REFLECTED CEILING PLAN 1/A-301 AND MECHANICAL
PLANS FOR ADD'L. INFORMATION.
REMOVE KITCHEN CEILING THROUGHOUT AND SALVAGE ALL LIGHT
FIXTURES FOR POSSIBLE REUSE OR STORAGE PER OWNER'S DIRECTION.
REMOVE AND RELOCATE SPRINKLER HEADS AS REQUIRED AT AREAS
OF CEILING DEMOLITION. SEE GENERAL NOTE #4.
SOFFIT TO REMAIN.
CEILING PLAN DEMO GENERAL NOTES:
1. UNLESS OTHERWISE NOTED, CONTRACTOR SHALL REMOVE ALL
EXISTING LIGHT FIXTURES, MAKING EVERY EFFORT TO AVOID
DAMAGE. REMOVE ALL CIRCUITRY BACK TO PANEL OR REUSE
AS NECESSARY FOR NEW LIGHTING LAYOUT. STORE LIGHT
FIXTURES IN OWNER PROVIDED SECURE STORAGE ON RESORT
SITE.
2. AT LOCATIONS OF GYPSUM CEILING DEMO, CONTRACTOR
SHALL MAKE EVERY EFFORT TO AVOID DAMAGING SYSTEMS,
ASSEMBLIES, FIREPROOFING, ETC. ABOVE THE CEILING.
CEILING GRID WIRE TIES TO STRUCTURE SHOULD BE MAINTAINED
FOR RE-USE WHERE POSSIBLE.
3. CONTRACTOR SHALL REMOVE ALL CEILING MILLWORK AND
MAKE EVERY EFFORT TO AVOID DAMAGE TO MILLWORK..
STORE MILLWORK ON RESORT SITE IN SECURE AREA,
COORDINATE LOCATION WITH ENGINEERING DEPARTMENT.
4. FIRE SPRINKLER CHANGES SHALL BE DESIGNED BY THE FIRE
SPRINKLER CONTRACTOR (ALL STATE FIRE PROTECTION) AND
SUBMITTED BY DEFERRED SUBMITTAL IN ACCORDANCE WITH
ALL TOWN OF VAIL AND BUILDING DEPARTMENT
REQUIREMENTS.
5. CEILING HEIGHTS INDICATED ARE APPROXIMATE AND SHOULD
BE VERIFIED BY CONTRACTOR WHERE APPLICABLE.
2
3
4
5
6
7
8
ENTRY
100
DINING
ROOM
102
MASTER
BATH
106
MASTER
BED
105
BATH 2
111
BED 2
110
LIVING
ROOM
104
BED 3
108
BATH 3
109
LC
LC
JS(E)
LC
JS(E)
JS(E)
LAUNDRY (E)
113
POWDER
114
KITCHEN (E)
103
MEDIA (E)
101
HALLWAY
107
HALLWAY
112
6
4 5 4
4
1
5
7
7
7 7 7 7
1
1
1
1
8 8
8
8
4
2
2
2 2 2
2
2
2
2
2
2
2
2
2
2
2
2
2
5
WALL LEGEND:
DASHED LINES INDICATE WALLS/DOORS/MILLWORK TO BE DEMOLISHED, CONTRACTOR SHALL MAKE EVERY EFFORT TO REMOVE MILLWORK FOR RE-USE. IN
ADDITION, ALL ELECTRICAL, LOW VOLTAGE, PLUMBING, HVAC, ETC. SHALL BE REMOVED/ TERMINATED AND DISPOSED OF AS REQUIRED BY GOVERNING CODES.
RE-USE EXISTING CIRCUITS AND/OR JUNCTION BOX LOCATIONS AS INDICATED IN CONSTRUCTION DRAWINGS.
HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D.
SMOKE DETECTOR, EXISTING U.O.N.
NEW RECESSED DOWNLIGHT
THREE WAY SWITCH
SINGLE POLE SWITCH
WALL MOUNTED FIXTURE, EXISTING U.O.N.
NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT
CEILING PLAN LEGEND:
RECESSED SPRINKLER HEAD, EXISTING U.O.N.
WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N.
EMERGENCY VOICE COMMUNICATION (EVC) SYSTEM
SPEAKER CEILING OR WALL MOUNTED. EXISTING U.O.N.
CEILING FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
NEW WALL MOUNTED FIXTURE
NEW RECESSED WALL WASH
EXISTING EXHAUST FAN, NO CHANGE
LOW VOLTAGE OR LED STRIP
ACCESS PANEL
DOOR JAMB SWITCH
JS
NEW RECESSED ADJUSTABLE ACCENT
KEYPAD
RF TABLETOP KEYPAD
RF LAMP DIMMER - PLUG INTO HOT OUTLET
NEW HANGING PENDANT OR CHANDELIER
RECESSED LINEAR LIGHT
SURFACE-MOUNTED LINEAR LIGHT
48"
W
P
SCALE: 1/4" = 1'-0" 1
DEMO REFLECTED CEILING PLAN
DEMO REFLECTED
CEILING PLAN
05 OF 22
A-300
ISSUE DATE
UNIT 9203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
VK
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
VK
UNIT 9203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Tim & Nancy Buese
Unit 9203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Duet Design Group, LLC
901 ACOMA SUITE 200
DENVER, CO 80204
t. 303-783-9327
miranda@duetdesigngroup.com
MECH/PLUMBING ENGINEER:
Rader Engineering
PO BOX 8610
AVON, CO 80620
t. 970-845-7910
BryanH@raderengineering.com
ELECTRICAL ENGINEER:
C3S Incorporated
3212 WEST 45TH AVENUE
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
LIGHTING DESIGN:
186 Lighting Design Group, Inc.
1200 BANNOCK STREET
DENVER, CO 80204
t. 303-534-5350
gmackell@186group.com
KITCHEN DESIGN:
exquisite kitchen design
601 SOUTH BROADWAY SUITE F
DENVER, CO 80209
303-282-0382
mikalo@myekdesign.com
16-27
FOR PERMIT
5/5/2017
2/22/17
1
FOR CONSTRUCTION
5/5/17
1
1
06/06/17