HomeMy WebLinkAboutB17-0027_A-300_1496780520.pdf1 CEILING PLAN DEMO KEY NOTES: EXISTING DECORATIVE FIXTURE TO BE REPLACED IN SAME LOCATION. EXISTING SWITCH BANK/KEYPAD/CONTROL LOCATION TO BE REMOVED, RELOCATED AND/OR RECONFIGURED RE: REFLECTED CEILING PLAN 1/A-301 AND LIGHTING PLAN L-100. NOT USED. EXISTING SUPPLY DIFFUSER TO BE RELOCATED AND/OR RECONFIGURED AS SHOWN ON 1/A-301. EXISTING RETURN AIR SLOT TO BE REMOVED/ RECONFIGURED AS REQUIRED, RE: REFLECTED CEILING PLAN 1/A-301 AND MECHANICAL PLANS FOR ADD'L. INFORMATION. REMOVE KITCHEN CEILING THROUGHOUT AND SALVAGE ALL LIGHT FIXTURES FOR POSSIBLE REUSE OR STORAGE PER OWNER'S DIRECTION. REMOVE AND RELOCATE SPRINKLER HEADS AS REQUIRED AT AREAS OF CEILING DEMOLITION. SEE GENERAL NOTE #4. SOFFIT TO REMAIN. CEILING PLAN DEMO GENERAL NOTES: 1. UNLESS OTHERWISE NOTED, CONTRACTOR SHALL REMOVE ALL EXISTING LIGHT FIXTURES, MAKING EVERY EFFORT TO AVOID DAMAGE. REMOVE ALL CIRCUITRY BACK TO PANEL OR REUSE AS NECESSARY FOR NEW LIGHTING LAYOUT. STORE LIGHT FIXTURES IN OWNER PROVIDED SECURE STORAGE ON RESORT SITE. 2. AT LOCATIONS OF GYPSUM CEILING DEMO, CONTRACTOR SHALL MAKE EVERY EFFORT TO AVOID DAMAGING SYSTEMS, ASSEMBLIES, FIREPROOFING, ETC. ABOVE THE CEILING. CEILING GRID WIRE TIES TO STRUCTURE SHOULD BE MAINTAINED FOR RE-USE WHERE POSSIBLE. 3. CONTRACTOR SHALL REMOVE ALL CEILING MILLWORK AND MAKE EVERY EFFORT TO AVOID DAMAGE TO MILLWORK.. STORE MILLWORK ON RESORT SITE IN SECURE AREA, COORDINATE LOCATION WITH ENGINEERING DEPARTMENT. 4. FIRE SPRINKLER CHANGES SHALL BE DESIGNED BY THE FIRE SPRINKLER CONTRACTOR (ALL STATE FIRE PROTECTION) AND SUBMITTED BY DEFERRED SUBMITTAL IN ACCORDANCE WITH ALL TOWN OF VAIL AND BUILDING DEPARTMENT REQUIREMENTS. 5. CEILING HEIGHTS INDICATED ARE APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR WHERE APPLICABLE. 2 3 4 5 6 7 8 ENTRY 100 DINING ROOM 102 MASTER BATH 106 MASTER BED 105 BATH 2 111 BED 2 110 LIVING ROOM 104 BED 3 108 BATH 3 109 LC LC JS(E) LC JS(E) JS(E) LAUNDRY (E) 113 POWDER 114 KITCHEN (E) 103 MEDIA (E) 101 HALLWAY 107 HALLWAY 112 6 4 5 4 4 1 5 7 7 7 7 7 7 1 1 1 1 8 8 8 8 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5 WALL LEGEND: DASHED LINES INDICATE WALLS/DOORS/MILLWORK TO BE DEMOLISHED, CONTRACTOR SHALL MAKE EVERY EFFORT TO REMOVE MILLWORK FOR RE-USE. IN ADDITION, ALL ELECTRICAL, LOW VOLTAGE, PLUMBING, HVAC, ETC. SHALL BE REMOVED/ TERMINATED AND DISPOSED OF AS REQUIRED BY GOVERNING CODES. RE-USE EXISTING CIRCUITS AND/OR JUNCTION BOX LOCATIONS AS INDICATED IN CONSTRUCTION DRAWINGS. HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D. SMOKE DETECTOR, EXISTING U.O.N. NEW RECESSED DOWNLIGHT THREE WAY SWITCH SINGLE POLE SWITCH WALL MOUNTED FIXTURE, EXISTING U.O.N. NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT CEILING PLAN LEGEND: RECESSED SPRINKLER HEAD, EXISTING U.O.N. WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N. EMERGENCY VOICE COMMUNICATION (EVC) SYSTEM SPEAKER CEILING OR WALL MOUNTED. EXISTING U.O.N. CEILING FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. NEW WALL MOUNTED FIXTURE NEW RECESSED WALL WASH EXISTING EXHAUST FAN, NO CHANGE LOW VOLTAGE OR LED STRIP ACCESS PANEL DOOR JAMB SWITCH JS NEW RECESSED ADJUSTABLE ACCENT KEYPAD RF TABLETOP KEYPAD RF LAMP DIMMER - PLUG INTO HOT OUTLET NEW HANGING PENDANT OR CHANDELIER RECESSED LINEAR LIGHT SURFACE-MOUNTED LINEAR LIGHT 48" W P SCALE: 1/4" = 1'-0" 1 DEMO REFLECTED CEILING PLAN DEMO REFLECTED CEILING PLAN 05 OF 22 A-300 ISSUE DATE UNIT 9203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO VK CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED VK UNIT 9203 REMODEL SEAL & SIGNATURE: CLIENT: Tim & Nancy Buese Unit 9203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Duet Design Group, LLC 901 ACOMA SUITE 200 DENVER, CO 80204 t. 303-783-9327 miranda@duetdesigngroup.com MECH/PLUMBING ENGINEER: Rader Engineering PO BOX 8610 AVON, CO 80620 t. 970-845-7910 BryanH@raderengineering.com ELECTRICAL ENGINEER: C3S Incorporated 3212 WEST 45TH AVENUE DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com LIGHTING DESIGN: 186 Lighting Design Group, Inc. 1200 BANNOCK STREET DENVER, CO 80204 t. 303-534-5350 gmackell@186group.com KITCHEN DESIGN: exquisite kitchen design 601 SOUTH BROADWAY SUITE F DENVER, CO 80209 303-282-0382 mikalo@myekdesign.com 16-27 FOR PERMIT 5/5/2017 2/22/17 1 FOR CONSTRUCTION 5/5/17 1 1 06/06/17