CEILING PLAN KEY NOTES:
REPLACE EXISTING DECORATIVE FIXTURE AS SELECTED BY DESIGNER.
UTILIZE EXISTING ROUGH-IN LOCATION (U.O.N.) AND SWITCHING.
NOT USED.
EXISTING SWITCH BANK/KEYPAD/CONTROL LOCATION TO
ACCOMMODATE NEW COMPONENTS AS SHOWN, COORDINATE
RELOCATION IF REQUIRED, COMPONENTS AND FUNCTION WITH
LIGHTING CONTROL VENDOR AND OWNER.
PROPOSED KEYPAD/CONTROL LOCATION. COORDINATE LOCATION
AND REQUIRED COMPONENTS WITH LIGHTING CONTROL VENDOR
AND OWNER. COORDINATE WIRING REQT'S WITH EXISTING SYSTEM
AND NEW FIXTURES.
RELOCATE SUPPLY DIFFUSER AS REQUIRED, RECONNECT DUCTWORK
TO SAME AIR HANDLING UNIT.
NEW AND/OR RECONFIGURED RETURN AIR SLOT AS REQUIRED.
CONSTRUCT IN SIMILAR FASHION TO EXISTING RETURN AIR OPENINGS
AND MAINTAIN RETURN AIR REQUIREMENTS.
NEW SUPPLY DIFFUSER, MAINTAIN EXISTING CFM AS REQUIRED.
NEW RETURN AIR GRILLE IN FACE OF SOFFIT.
NEW PERIMETER LIGHT COVE, RE: DETAIL 2/A-301.
NEW REVERSE LIGHT COVE, RE: DETAIL 3/A-301.
RECONFIGURE/RELOCATE FIRE SPRINKLER AS REQUIRED PER GENERAL
NOTE #6.
COORDINATE POWER & CONTROL REQUIREMENTS FOR NEW RANGE
HOOD WITH KITCHEN DESIGNER.
NEW EXTERIOR LOUVER FOR RANGE HOOD EXHAUST
PER DRB APPROVAL #DRB17-0090.
NEW EXTERIOR LOUVER FOR MAKE-UP AIR UNIT INTAKE
PER DRB APPROVAL #DRB17-0090.
CEILING PLAN GENERAL NOTES:
1. NEW LIGHTING AND LIGHTING CONTROL SYSTEM THROUGHOUT
UNLESS NOTED OTHERWISE. COORDINATE REQUIRED WIRING
WITH FIXTURES AND LIGHTING CONTROL SYSTEM.
2. SEE ELECTRICAL DRAWINGS FOR CIRCUITING. COORDINATE
CIRCUITING AND CONTROLS WITH LIGHTING CONTROL
VENDOR.
3. SEE LIGHTING PLANS SHEETS L-000 AND L-100 FOR ADDITIONAL
LIGHTING AND CONTROLS INFORMATION.
4. FIRE SPRINKLER CHANGES SHALL BE DESIGNED BY THE FIRE
SPRINKLER CONTRACTOR (ALL STATE FIRE PROTECTION) AND
SUBMITTED BY DEFERRED SUBMITTAL IN ACCORDANCE WITH ALL
TOWN OF VAIL AND BUILDING DEPARTMENT REQUIREMENTS.
5. CEILING HEIGHTS INDICATED ARE APPROXIMATE AND SHOULD
BE VERIFIED BY CONTRACTOR WHERE APPLICABLE.
6. CONTRACTOR SHALL MAINTAIN REQUIRED ACCESS TO ALL
ABOVE-CEILING EQUIPMENT, REORIENT/RELOCATE ACCESS
PANELS AND/OR EQUIPMENT AS REQUIRED.
7. COORDINATE INTEGRATED MILLWORK LED LIGHTING INCL.
OUTLET/TRANSFORMER LOCATIONS WITH KITCHEN DESIGNER.
2
3
4
6
7
5
8
9
10
11
12
13
9A
ENTRY
100
DINING
ROOM
102
KITCHEN
101
MASTER
BATH
106
MASTER
BED
105
BATH 2
111
BED 2
110
LIVING
ROOM
104
POWDER
114
SKI
CLOSET
115
MUD ROOM
113
BED 3
108
BATH 3
109
JS(E)
JS(E)
JS(E)
SITTING
103
HALLWAY
112
HALLWAY
107
48"
24" A2F
A1F
A1F
L1
L3
C1
L3
L3
L3
A3
%$&./,7 0,5525
L3
L3
L1C
A2F
L1
L1
A3
A3
A3 A3
A3
A3
S1
A3
L1
W
W
A2F
A2F
A1F
A1F
A2F
A2F A2F
A2F
W W
A3 S1
S1
A3
A3
A3
W W
A2F
L1
L1
L1
A2F
A2F
A1F
A2F
L4
A2F
A2F
A2F
A1F
A1F A1F
FL1
FL1
FL1
FL1
C1 C1
A2F
A1F
A1F
A1F
C1
A3
A3
A3 A3 A3
A3
S1
S1 S1
A3
L1C
A3
S1
A3
A3
A3
A3
A3
A3 A3 A3
A3
A1F A1F
A1F
A1F A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F A1F
A1F A1F
SLOPE DN
1
1
11
ALIGN
ALIGN, TYP.
4
3
4
4
3
3
3
3
4
4
4
4
4
3
4
4
3
4
4
4
4
4 4
11
9 9 9
9A
8
10
10
10
10 5 5 7
7 5
66
6
7
12
13
4
6
CENTER OVER
LAVATORY
LINE OF VANITY BELOW
9
TRANSITION FROM REVERSE COVE
DETAIL (3/A-301) TO PERIMETER
COVE DETAIL (2/A-301) AT EDGE
OF FIREPLACE WALL
9A
WALL LEGEND:
HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D.
HATCH INDICATES NEW WALL CONSTRUCTION. DIMENSIONS ARE TO FINISH FACE OF GYPSUM BOARD U.O.N. INTERIOR WALL CONSTRUCTION SHALL BE 20GA
CFMF U.O.N.
SMOKE DETECTOR, EXISTING U.O.N.
NEW RECESSED DOWNLIGHT
THREE WAY SWITCH
SINGLE POLE SWITCH
WALL MOUNTED FIXTURE, EXISTING U.O.N.
NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT
CEILING PLAN LEGEND:
RECESSED SPRINKLER HEAD, EXISTING U.O.N.
WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N.
EMERGENCY VOICE COMMUNICATION (EVC) SYSTEM
SPEAKER CEILING OR WALL MOUNTED. EXISTING U.O.N.
CEILING FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
NEW WALL MOUNTED FIXTURE
NEW RECESSED WALL WASH
EXISTING EXHAUST FAN, NO CHANGE
LOW VOLTAGE OR LED STRIP
ACCESS PANEL
DOOR JAMB SWITCH JS
NEW RECESSED ADJUSTABLE ACCENT
KEYPAD
RF TABLETOP KEYPAD
RF LAMP DIMMER - PLUG INTO HOT OUTLET
NEW HANGING PENDANT OR CHANDELIER
RECESSED LINEAR LIGHT
SURFACE-MOUNTED LINEAR LIGHT
48"
W
P
ALIGN CENTER
OF FIXTURE AND
VALANCE
CONTINUE WALL
FINISH TO CEILING
ALIGN TOP OF
FIXTURE AND
VALANCE
L1 LED
STRIP LIGHT
MATTE WHITE
FINISH, TYP.
4" 1"
1"
MATTE WHITE
FINISH, TYP.
L1 LED
STRIP LIGHT
SKIM-COAT CONC.
9'-1" A.F.F.
GYP. CEILING
8'-8" A.F.F.
SKIM-COAT CONC.
9'-1" A.F.F.
GYP. CEILING
8'-8" A.F.F.
SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN
REFLECTED CEILING
PLAN
06 OF 22
A-301
ISSUE DATE
UNIT 9203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
VK
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
VK
UNIT 9203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Tim & Nancy Buese
Unit 9203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Duet Design Group, LLC
901 ACOMA SUITE 200
DENVER, CO 80204
t. 303-783-9327
miranda@duetdesigngroup.com
MECH/PLUMBING ENGINEER:
Rader Engineering
PO BOX 8610
AVON, CO 80620
t. 970-845-7910
BryanH@raderengineering.com
ELECTRICAL ENGINEER:
C3S Incorporated
3212 WEST 45TH AVENUE
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
LIGHTING DESIGN:
186 Lighting Design Group, Inc.
1200 BANNOCK STREET
DENVER, CO 80204
t. 303-534-5350
gmackell@186group.com
KITCHEN DESIGN:
exquisite kitchen design
601 SOUTH BROADWAY SUITE F
DENVER, CO 80209
303-282-0382
mikalo@myekdesign.com
16-27
FOR PERMIT
5/5/2017
2/22/17
1
FOR CONSTRUCTION
5/5/17
1
1
1
SCALE: 3" = 1'-0"
2 PERIMETER LIGHT COVE DETAIL
SCALE: 3" = 1'-0" 3 REVERSE LIGHT COVE DETAIL
1
1
1
06/06/17