HomeMy WebLinkAboutB17-0027_A-301_1496780520.pdf1 CEILING PLAN KEY NOTES: REPLACE EXISTING DECORATIVE FIXTURE AS SELECTED BY DESIGNER. UTILIZE EXISTING ROUGH-IN LOCATION (U.O.N.) AND SWITCHING. NOT USED. EXISTING SWITCH BANK/KEYPAD/CONTROL LOCATION TO ACCOMMODATE NEW COMPONENTS AS SHOWN, COORDINATE RELOCATION IF REQUIRED, COMPONENTS AND FUNCTION WITH LIGHTING CONTROL VENDOR AND OWNER. PROPOSED KEYPAD/CONTROL LOCATION. COORDINATE LOCATION AND REQUIRED COMPONENTS WITH LIGHTING CONTROL VENDOR AND OWNER. COORDINATE WIRING REQT'S WITH EXISTING SYSTEM AND NEW FIXTURES. RELOCATE SUPPLY DIFFUSER AS REQUIRED, RECONNECT DUCTWORK TO SAME AIR HANDLING UNIT. NEW AND/OR RECONFIGURED RETURN AIR SLOT AS REQUIRED. CONSTRUCT IN SIMILAR FASHION TO EXISTING RETURN AIR OPENINGS AND MAINTAIN RETURN AIR REQUIREMENTS. NEW SUPPLY DIFFUSER, MAINTAIN EXISTING CFM AS REQUIRED. NEW RETURN AIR GRILLE IN FACE OF SOFFIT. NEW PERIMETER LIGHT COVE, RE: DETAIL 2/A-301. NEW REVERSE LIGHT COVE, RE: DETAIL 3/A-301. RECONFIGURE/RELOCATE FIRE SPRINKLER AS REQUIRED PER GENERAL NOTE #6. COORDINATE POWER & CONTROL REQUIREMENTS FOR NEW RANGE HOOD WITH KITCHEN DESIGNER. NEW EXTERIOR LOUVER FOR RANGE HOOD EXHAUST PER DRB APPROVAL #DRB17-0090. NEW EXTERIOR LOUVER FOR MAKE-UP AIR UNIT INTAKE PER DRB APPROVAL #DRB17-0090. CEILING PLAN GENERAL NOTES: 1. NEW LIGHTING AND LIGHTING CONTROL SYSTEM THROUGHOUT UNLESS NOTED OTHERWISE. COORDINATE REQUIRED WIRING WITH FIXTURES AND LIGHTING CONTROL SYSTEM. 2. SEE ELECTRICAL DRAWINGS FOR CIRCUITING. COORDINATE CIRCUITING AND CONTROLS WITH LIGHTING CONTROL VENDOR. 3. SEE LIGHTING PLANS SHEETS L-000 AND L-100 FOR ADDITIONAL LIGHTING AND CONTROLS INFORMATION. 4. FIRE SPRINKLER CHANGES SHALL BE DESIGNED BY THE FIRE SPRINKLER CONTRACTOR (ALL STATE FIRE PROTECTION) AND SUBMITTED BY DEFERRED SUBMITTAL IN ACCORDANCE WITH ALL TOWN OF VAIL AND BUILDING DEPARTMENT REQUIREMENTS. 5. CEILING HEIGHTS INDICATED ARE APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR WHERE APPLICABLE. 6. CONTRACTOR SHALL MAINTAIN REQUIRED ACCESS TO ALL ABOVE-CEILING EQUIPMENT, REORIENT/RELOCATE ACCESS PANELS AND/OR EQUIPMENT AS REQUIRED. 7. COORDINATE INTEGRATED MILLWORK LED LIGHTING INCL. OUTLET/TRANSFORMER LOCATIONS WITH KITCHEN DESIGNER. 2 3 4 6 7 5 8 9 10 11 12 13 9A ENTRY 100 DINING ROOM 102 KITCHEN 101 MASTER BATH 106 MASTER BED 105 BATH 2 111 BED 2 110 LIVING ROOM 104 POWDER 114 SKI CLOSET 115 MUD ROOM 113 BED 3 108 BATH 3 109 JS(E) JS(E) JS(E) SITTING 103 HALLWAY 112 HALLWAY 107 48" 24" A2F A1F A1F L1 L3 C1 L3 L3 L3 A3 ƒ %$&./,7 0,5525 L3 L3 L1C A2F L1 L1 A3 A3 A3 A3 A3 A3 S1 A3 L1 W W A2F A2F A1F A1F A2F A2F A2F A2F W W A3 S1 S1 A3 A3 A3 W W A2F L1 L1 L1 A2F A2F A1F A2F L4 A2F A2F A2F A1F A1F A1F FL1 FL1 FL1 FL1 C1 C1 A2F A1F A1F A1F C1 A3 A3 A3 A3 A3 A3 S1 S1 S1 A3 L1C A3 S1 A3 A3 A3 A3 A3 A3 A3 A3 A3 A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F A1F SLOPE DN 1 1 11 ALIGN ALIGN, TYP. 4 3 4 4 3 3 3 3 4 4 4 4 4 3 4 4 3 4 4 4 4 4 4 11 9 9 9 9A 8 10 10 10 10 5 5 7 7 5 66 6 7 12 13 4 6 CENTER OVER LAVATORY LINE OF VANITY BELOW 9 TRANSITION FROM REVERSE COVE DETAIL (3/A-301) TO PERIMETER COVE DETAIL (2/A-301) AT EDGE OF FIREPLACE WALL 9A WALL LEGEND: HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D. HATCH INDICATES NEW WALL CONSTRUCTION. DIMENSIONS ARE TO FINISH FACE OF GYPSUM BOARD U.O.N. INTERIOR WALL CONSTRUCTION SHALL BE 20GA CFMF U.O.N. SMOKE DETECTOR, EXISTING U.O.N. NEW RECESSED DOWNLIGHT THREE WAY SWITCH SINGLE POLE SWITCH WALL MOUNTED FIXTURE, EXISTING U.O.N. NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT CEILING PLAN LEGEND: RECESSED SPRINKLER HEAD, EXISTING U.O.N. WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N. EMERGENCY VOICE COMMUNICATION (EVC) SYSTEM SPEAKER CEILING OR WALL MOUNTED. EXISTING U.O.N. CEILING FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. NEW WALL MOUNTED FIXTURE NEW RECESSED WALL WASH EXISTING EXHAUST FAN, NO CHANGE LOW VOLTAGE OR LED STRIP ACCESS PANEL DOOR JAMB SWITCH JS NEW RECESSED ADJUSTABLE ACCENT KEYPAD RF TABLETOP KEYPAD RF LAMP DIMMER - PLUG INTO HOT OUTLET NEW HANGING PENDANT OR CHANDELIER RECESSED LINEAR LIGHT SURFACE-MOUNTED LINEAR LIGHT 48" W P ALIGN CENTER OF FIXTURE AND VALANCE CONTINUE WALL FINISH TO CEILING ALIGN TOP OF FIXTURE AND VALANCE L1 LED STRIP LIGHT MATTE WHITE FINISH, TYP. 4" 1" 1" MATTE WHITE FINISH, TYP. L1 LED STRIP LIGHT SKIM-COAT CONC. 9'-1" A.F.F. GYP. CEILING 8'-8" A.F.F. SKIM-COAT CONC. 9'-1" A.F.F. GYP. CEILING 8'-8" A.F.F. SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN REFLECTED CEILING PLAN 06 OF 22 A-301 ISSUE DATE UNIT 9203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO VK CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED VK UNIT 9203 REMODEL SEAL & SIGNATURE: CLIENT: Tim & Nancy Buese Unit 9203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Duet Design Group, LLC 901 ACOMA SUITE 200 DENVER, CO 80204 t. 303-783-9327 miranda@duetdesigngroup.com MECH/PLUMBING ENGINEER: Rader Engineering PO BOX 8610 AVON, CO 80620 t. 970-845-7910 BryanH@raderengineering.com ELECTRICAL ENGINEER: C3S Incorporated 3212 WEST 45TH AVENUE DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com LIGHTING DESIGN: 186 Lighting Design Group, Inc. 1200 BANNOCK STREET DENVER, CO 80204 t. 303-534-5350 gmackell@186group.com KITCHEN DESIGN: exquisite kitchen design 601 SOUTH BROADWAY SUITE F DENVER, CO 80209 303-282-0382 mikalo@myekdesign.com 16-27 FOR PERMIT 5/5/2017 2/22/17 1 FOR CONSTRUCTION 5/5/17 1 1 1 SCALE: 3" = 1'-0" 2 PERIMETER LIGHT COVE DETAIL SCALE: 3" = 1'-0" 3 REVERSE LIGHT COVE DETAIL 1 1 1 06/06/17