Loading...
HomeMy WebLinkAboutB17-0027_A-401_1496780460.pdfTHERMOSTAT FOURPLEX WALL OUTLET TELEPHONE JACK DUPLEX WALL RECEPTACLE FLOOR DUPLEX RECEPTACLE TV / COAXIAL RECEPTACLE 220V WALL RECEPTACLE POWER/DATA PLAN LEGEND: TELEPHONE & DATA JACK IN-FLOOR TELEPHONE JACK DATA JACK T 1 POWER & COMMUNICATION PLAN KEY NOTES: NEW/RELOCATED OUTLET/DEVICE AS INDICATED. NEW KITCHEN APPLIANCE OUTLET AS INDICATED. COORDINATE LOCATION/ELEVATION WITH REQUIREMENTS OF APPLIANCES. NEW GFCI OUTLET. NEW POWER/DATA FOR A/V RACK AS REQUIRED. NEW/RELOCATED TV SETUP AS SHOWN, COORDINATE LOCATION/ ELEVATION WITH INTERIOR DESIGNER. NEW ELECTRIC FLOOR HEAT MAT, RE: ELECTRICAL AND PLUMBING DRAWINGS FOR SPECIFICATIONS AND ADDITIONAL INFORMATION. CONTRACTOR TO GPR SLAB PRIOR TO CHIPPING FLOOR FOR POWER FEED TO KITCHEN ISLAND POWER & COMMUNICATION PLAN GENERAL NOTES: 1. UNLESS OTHERWISE NOTED, ALL RECEPTACLES (POWER, TV, TELE/DATA) SHALL MATCH EXISTING ELEVATIONS AFF. 2. NOT ALL EXISTING ELECTRICAL OR COMMUNICATIONS DEVICES ARE SHOWN. THOSE SHOWN ARE FOR REFERENCE AND COORDINATION ONLY. 3. SYMBOLS MARKED WITH "E" INDICATE EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4. AT ALL RATED WALL ASSEMBLIES AS INDICATED ON PLANS WHERE NEW ELECTRICAL/LOW VOLTAGE IS INSTALLED , CONTRACTOR SHALL PROVIDE APPLICABLE FIRE-RATED ASSEMBLIES TO MAINTAIN RATING INTEGRITY AS REQUIRED. 5. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2 3 FLOOR FOURPLEX RECEPTACLE 4 5 6 7 ENTRY 100 DINING ROOM 102 KITCHEN 101 MASTER BATH 106 MASTER BED 105 BATH 2 111 BED 2 110 LIVING ROOM 104 POWDER 114 SKI CLOSET 115 MUD ROOM 113 BED 3 108 BATH 3 109 E E E E E E E E E E E E E E E E W D TV E TV TV WINE DW HOOD MW RANGE TV FRIDGE FREEZER DRAWERS W/ ICEMAKER E E E T E T T E E E E E E E E E E E E E E E E E E E E E E SITTING 103 HALLWAY 112 HALLWAY 107 T TV 2 1 1 1 1 5 3 3 3 3 2 2 2 2 2 3 3 1 6 6 6 1 1 1 1 5 4 7 5 WALL LEGEND: HATCH INDICATES EXISTING WALLS TO REMAIN. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT EXISTING WALLS FROM DAMAGE AND REPAIR AS REQ'D. HATCH INDICATES NEW WALL CONSTRUCTION. DIMENSIONS ARE TO FINISH FACE OF GYPSUM BOARD U.O.N. INTERIOR WALL CONSTRUCTION SHALL BE 20GA CFMF U.O.N. SCALE: 1/4" = 1'-0" 1 POWER & COMMUNICATION PLAN POWER & COMMUNICATION PLAN 08 OF 22 A-401 ISSUE DATE UNIT 9203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO VK CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED VK UNIT 9203 REMODEL SEAL & SIGNATURE: CLIENT: Tim & Nancy Buese Unit 9203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Duet Design Group, LLC 901 ACOMA SUITE 200 DENVER, CO 80204 t. 303-783-9327 miranda@duetdesigngroup.com MECH/PLUMBING ENGINEER: Rader Engineering PO BOX 8610 AVON, CO 80620 t. 970-845-7910 BryanH@raderengineering.com ELECTRICAL ENGINEER: C3S Incorporated 3212 WEST 45TH AVENUE DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com LIGHTING DESIGN: 186 Lighting Design Group, Inc. 1200 BANNOCK STREET DENVER, CO 80204 t. 303-534-5350 gmackell@186group.com KITCHEN DESIGN: exquisite kitchen design 601 SOUTH BROADWAY SUITE F DENVER, CO 80209 303-282-0382 mikalo@myekdesign.com 16-27 FOR PERMIT 5/5/2017 2/22/17 1 FOR CONSTRUCTION 5/5/17 1 06/06/17