HomeMy WebLinkAboutB17-0027_E-100_1490802540.pdfGFCI GFCI GFCI GFCIGFCI S F 3 S3 S3 S3 S 3 SGFCI GFCI S S S S GFCI S SS SS 3 S3SS S WD R MW S SS S GFCI MW OVEN S GFCI LC S LC S "PP-P9B" (CONDO) "PP-CD16" "PP-CD15" "PP-CD12" "PP-CD11" "PP-CD10" "PP-CD7" "PP-CD6" "PP-CD5" "PP-CD3" "PP-CD2" 1000 AMPS DISTRIBUTION PANEL "DP-DC2" 208/120V., 3ɸ, 4 WIRE ISC = 18,000 100A3P 100A3P 100A3P 100A3P 100A3P 225A3P 100A3P 100A3P 100A3P 200A3P 60A3P 100A3P 100A3P SPARE SPARE 1000A3P 30A3P 300 KVA TRANSFORMER "TR-5" 480/208/120V., 3ɸ, 4 WIRE (K-4 RATED) TO 500A3P BREAKER IN 3000 AMP MAIN SWITCHBOARD "MSB-B", 480/277V., 3ɸ, 4 WIRE UNIT 1024 UNIT 8203 UNIT 7203 UNIT 9203 "PP-CD10A" 70A3P (NEW) (NEW) 1 RECONNECT EXISTING LOAD ON CIRCUIT 37 TO BREAKER #1 RECONNECT EXISTING LOAD ON CIRCUIT 39 TO BREAKER #15, RELOCATE GFI BREAKER TO BREAKER #15 PROVIDE NEW BREAKER AS SHOWN. + # = =+ # # + (NEW) 1. DEMOLITION PLANS ARE FOR REFERENCE AND MAY NOT SHOW ALL ELECTRICAL DEVICES THAT NEED TO BE DEMOLISHED DUE TO FIELD CONDITION DURING THE ELECTRICAL SURVEY. FIELD VERIFY PRIOR TO PRICING. REFER TO ARCHITECTURAL AND MECHANICAL PLANS FOR ADDITIONAL INFORMATION PRIOR TO PRICING. 2. ELECTRICAL DEVICES SHOWN AS DASHED SHALL BE REMOVED. REMOVE CIRCUITRY, CONDUITS, AND BOXES. ENSURE CIRCUIT CONTINUITY TO RECEPTACLES THAT ARE EXISTING TO REMAIN AND MAY BE AFFECTED BY DEMOLITION. 3. COORDINATE WITH OWNER DISPOSAL OF EXISTING EQUIPMENT TO BE REMOVED AND IF ANY EQUIPMENT IS TO BE RETURNED TO OWNER PRIOR TO PRICING. 4. TURN OFF ALL UNUSED BREAKERS AND INDICATE "SPARE" ON UPDATED PANEL INDEXES. NOTE TO ELECTRICAL CONTRACTOR - DEMOLITION DETAIL NOTES - ONE LINE DIAGRAM: 1 ELECTRICAL CONTRACTOR SHALL VERIFY IN FIELD IF EXISTING FEED TO UNIT 9203 PANEL IS 225A3P. ISSUE DATE UNIT 9203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO JMM CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED C3S, TNS UNIT 9203 REMODEL SEAL & SIGNATURE: CLIENT: Tim & Nancy Buese Unit 9203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Duet Design Group, LLC 901 ACOMA SUITE 200 DENVER, CO 80204 t. 303-783-9327 miranda@duetdesigngroup.com MECH/PLUMBING ENGINEER: Rader Engineering PO BOX 8610 AVON, CO 80620 t. 970-845-7910 BryanH@raderengineering.com ELECTRICAL ENGINEER: C3S Incorporated 1737 CENTRAL STREET SUITE 201 DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com LIGHTING DESIGN: 186 Lighting Design Group, Inc. 1200 BANNOCK STREET DENVER, CO 80204 t. 303-534-5350 gmackell@186group.com KITCHEN DESIGN: exquisite kitchen design 601 SOUTH BROADWAY SUITE F DENVER, CO 80209 303-282-0382 mikalo@myekdesign.com 16-27 1 FOR PERMIT 02/22/2017 2/22/17 OF 22 ELEC. DEMO, ONE LINE, AND PNLS 18E-100 SCALE: 1/4" = 1'-0" 1 ELECTRICAL DEMOLITION PLAN - UNIT 9203 NOT TO SCALE 2 EXISTING (PARTIAL) ONE LINE DIAGRAM ALL DASHED LINES INDICATE EXISTING TO REMAIN U.O.N. ALL SOLID LINES INDICATE NEW EQUIPMENT ALL HIDDEN LINES INDICATE FUTURE EQUIPMENT. ALL SHADED AREAS INDICATE EXISTING TO BE REMOVED. 03/29/17