HomeMy WebLinkAboutB17-0027_E-200_1490802540.pdfW D
GFCI
GFCI
GFCI
GFCIGFCI
GFCI
DW
RANGE
HOOD
GFCI
GFCI
GFCI GFCI
GFCI
BATH 3
109
BED 3
108
MUD ROOM
113
SKI
CLOSET
115
POWDER
114
LIVING
ROOM
104
BED 2
110
BATH 2
111
MASTER
BED
105
MASTER
BATH
106
KITCHEN
101
DINING
ROOM
102
ENTRY
100
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N) (N)
(N)
(N)
(R)
(N)
WINE
(N)
FRIDGE
GFCI
(N)
GFCI
(N)
(N)
MW
FREEZER
DRAWERS W/ ICE
MAKER
(N) GFCI
GFCI
(N)
GFCI (N)
S
HALLWAY
107
SITTING
103
HALLWAY
112
"CU-A" "FCU-B"
"EG-1"
EXHAUST
GRILL
"FCU-H"
SA-1"
SOUND
ATTENUATOR
"MAU-1"
"SF-1"
"KEH-1"
KITCHEN
EXHAUST
HOOD
"EG-1"
EXHAUST GRILLE
W/ VOLUME
CONTROL
"CU-A"
"CU-A"
"CU-A"
2
4
4a
2
FIREPLACE
2
10
(N)
7
6
PP CD10A-8
PP CD10A-2,4,6
PP CD10-14
1
PP CD10-24
PP CD10-29
1
1
8
S
(N)
PP CD10-27
1
PP CD10-30
1
PP CD10-42
1
PP CD10-38
1
PP CD10-26
1
PP CD10-16
1
PP CD10-1
1
"PP-CD10"
NEW
SUB-PANEL
"PP-CD10A"
3
9
2
5
(N)
HEAT MAT
PP CD10A-1
2
(N)
HEAT MAT
5
PP CD10A-3
FOURPLEX WALL OUTLET
TELEPHONE JACK
DUPLEX WALL RECEPTACLE
FLOOR DUPLEX RECEPTACLE
TV / COAXIAL RECEPTACLE
220V WALL RECEPTACLE
TELEPHONE & DATA JACK
IN-FLOOR TELEPHONE JACK
DATA JACK
HARDWIRE BOX LOCATION-AS NOTED, EXISTING
E
1. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS, ELEVATIONS,
DETAILS, ETC.. VERIFY MOUNTING HEIGHTS OF DEVICES AND ENSURE
MINIMUM 24" HORIZONTAL SEPARATION PER UBC IN FIRE RATED
DEMISING WALLS. PROVIDE FIRE-STOP OR ADDITIONAL RATED GYP
BOARD AS REQUIRED. COORDINATE WITH FIRE DEPT./INSPECTOR AND
G.C.
2. UNIT LIGHT FIXTURES TO BE SELECTED BY OWNER AND RATED FOR
INSULATED CEILINGS WHERE NEEDED. ENSURE PROPER LOCAL
SWITCHING. LIGHTING FURNISHED BY E.C. TO BE COORDINATED WITH
CEILING TYPES, MECHANICAL WORK, STRUCTURAL MEMBERS, ETC.
VERIFY FINISHES AND LOCATIONS OF CONTROLS.
3. COORDINATE PRE-WIRING OF T.V. COAX AND TELEPHONE JACKS WITH
G.C. AND OWNER. VERIFY ALL WALL LOCATIONS WITH ARCHITECT
PRIOR TO ROUGH-IN.
4. PROVIDE RECEPTACLE LOCATIONS AND SPACING PER N.E.C. 210-52
THROUGHOUT. FIELD ADJUSTMENTS / MEASUREMENTS ARE REQUIRED
TO COMPLY. COORDINATE ADDITIONAL STUD WALL BRACING IF
REQUIRED FOR RECEPTACLE PLACEMENTS WITH G.C. IF APPLICABLE,
VERIFY FLOOR OUTLET LOCATIONS WITH ARCHITECT. PROVIDE GFI
RECEPTACLES WHERE REQUIRED BY CODE PER NEC 210.8.
5. PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION IN DWELLING
UNITS PER NEC 210.12. FAMILY ROOMS, DINING ROOMS, LIVING
ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR
AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT
INTERRUPTER TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.
VERIFY WITH LOCAL AUTHORITY HAVING JURISDICTION IF EXISTING
BRANCH CIRCUITS SHALL COMPLY WITH NEC 210.12.
6. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC 410.16.
7. ALL ELECTRICAL DEVICES AND LIGHT FIXTURE MOUNTING HEIGHTS
SHALL COMPLY TO THE "FAIR HOUSING ACT": DUPLEXES +15" A.F.F.,
SWITCHES AT +46" A.F.F. VERIFY WITH OWNER.
8. FOR NEW RECEPTACLES, PROVIDE TAMPER RESISTANT RECEPTACLES
THROUGHOUT DWELLING UNIT AS REQUIRED BY NEC 406.12
9. PROVIDE ACCURATE AND LEGIBLE PANEL INDEXES IDENTIFYING
SPECIFIC PURPOSE OR USE OF CIRCUIT BREAKERS PER NEC 408.4.
NOTE: UNLESS OTHERWISE NOTED, ALL NEW RECEPTACLES
SHALL MATCH EXISTING ELEVATIONS (AFF)
NOTE: NOT ALL EXISTING RECEPTACLES ARE SHOWN. THOSE SHOWN
ARE FOR REFERENCE AND ARE IN THE AREA OF CONSTRUCTION.
DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED
OR RELOCATED.
DETAIL NOTES - POWER:
ADDITIONAL LEGEND - POWER:
GENERAL NOTES - POWER:
1 RE-USE EXISTING CIRCUITRY MADE AVAILABLE THROUGH
DEMOLITION / RELOCATION.
CONNECT TO EXISTING 120V. RECEPTACLE / CIRCUIT.
NEW LOCATION FOR POWDER ROOM RECEPTACLE.
RE-CONNECT TO EXISTING 120V. CIRCUIT.
NEW HEAT MAT IN MASTER BATHROOM. RE-USE EXISTING
CIRCUIT (PP-CD10-40)
PROVIDE ADD ALTERNATE PRICING: NEW HEAT MAT IN
SHOWER. CONNECT TO EXISTING HEAT MAT CIRCUIT IN
MASTER BATHROOM.
NEW HEAT MAT IN THIS BATHROOM.
NEW MAKE UP AIR UNIT. 208V., 3ɸ, 16KW.
NEW SUPPLY FAN "SF-1" 120V., 1ɸ, 301 WATTS. REFER TO
MECHANICAL DRAWINGS FOR INTERLOCKING INFORMATION
WITH "MAU-1" AND "KEH-1".
"KEH-1" 120V., 1ɸ, 8.5 AMPS
PROVIDE NEW FLUSH MOUNTED PANEL "PP-CD10A".
PROVIDE 18 CIRCUITS PANEL. COORDINATE LOCATION WITH
OWNER AND ARCHITECT.
EXISTING FIREPLACE TO BE REPLACED WITH NEW FIREPLACE
UNIT. RE-USE EXISTING CIRCUITS FOR IGNITER. COORDINATE
EXACT REQUIREMENTS WITH VENDOR PRIOR TO DEMOLITION
AND INSTALLATION.
(N) = NEW FIXTURE (R) = RELOCATED
2
3
4
4a
FLOOR FOURLEX RECEPTACLE
5
6
7
8
9
10
ISSUE DATE
UNIT 9203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
JMM
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
C3S, TNS
UNIT 9203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Tim & Nancy Buese
Unit 9203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Duet Design Group, LLC
901 ACOMA SUITE 200
DENVER, CO 80204
t. 303-783-9327
miranda@duetdesigngroup.com
MECH/PLUMBING ENGINEER:
Rader Engineering
PO BOX 8610
AVON, CO 80620
t. 970-845-7910
BryanH@raderengineering.com
ELECTRICAL ENGINEER:
C3S Incorporated
1737 CENTRAL STREET SUITE 201
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
LIGHTING DESIGN:
186 Lighting Design Group, Inc.
1200 BANNOCK STREET
DENVER, CO 80204
t. 303-534-5350
gmackell@186group.com
KITCHEN DESIGN:
exquisite kitchen design
601 SOUTH BROADWAY SUITE F
DENVER, CO 80209
303-282-0382
mikalo@myekdesign.com
16-27
1
FOR PERMIT
02/22/2017
2/22/17
OF 22
POWER PLAN
19E-200
SCALE: 1/4" = 1'-0"
1
POWER PLAN - UNIT 9203
03/29/17