Loading...
HomeMy WebLinkAboutB17-0027_E-200_1496780520.pdfW D GFCI GFCI GFCI GFCIGFCI GFCI DW RANGE HOOD GFCI GFCI GFCI GFCI GFCI BATH 3 109 BED 3 108 MUD ROOM 113 SKI CLOSET 115 POWDER 114 LIVING ROOM 104 BED 2 110 BATH 2 111 MASTER BED 105 MASTER BATH 106 KITCHEN 101 DINING ROOM 102 ENTRY 100 (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (R) (N) WINE (N) FRIDGE GFCI (N) GFCI (N) (N) MW FREEZER DRAWERS W/ ICE MAKER (N) GFCI GFCI (N) GFCI (N) S HALLWAY 107 SITTING 103 HALLWAY 112 "CU-A" "FCU-B" "EG-1" EXHAUST GRILL "FCU-H" SA-1" SOUND ATTENUATOR "MAU-1" "SF-1" "KEH-1" KITCHEN EXHAUST HOOD "EG-1" EXHAUST GRILLE W/ VOLUME CONTROL "CU-A" "CU-A" "CU-A" 2 4 4a 2 FIREPLACE 2 10 (N) 7 6 PP CD10A-8 PP CD10A-2,4,6 PP CD10-14 1 PP CD10-24 PP CD10-29 1 1 8 S (N) PP CD10-27 1 PP CD10-30 1 PP CD10-42 1 PP CD10-38 1 PP CD10-26 1 PP CD10-16 1 PP CD10-1 1 "PP-CD10" NEW SUB-PANEL "PP-CD10A" 3 9 2 5 (N) HEAT MAT PP CD10A-1 2 (N) HEAT MAT 5 PP CD10A-3 11 FOURPLEX WALL OUTLET TELEPHONE JACK DUPLEX WALL RECEPTACLE FLOOR DUPLEX RECEPTACLE TV / COAXIAL RECEPTACLE 220V WALL RECEPTACLE TELEPHONE & DATA JACK IN-FLOOR TELEPHONE JACK DATA JACK HARDWIRE BOX LOCATION-AS NOTED, EXISTING E 1. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS, ELEVATIONS, DETAILS, ETC.. VERIFY MOUNTING HEIGHTS OF DEVICES AND ENSURE MINIMUM 24" HORIZONTAL SEPARATION PER UBC IN FIRE RATED DEMISING WALLS. PROVIDE FIRE-STOP OR ADDITIONAL RATED GYP BOARD AS REQUIRED. COORDINATE WITH FIRE DEPT./INSPECTOR AND G.C. 2. UNIT LIGHT FIXTURES TO BE SELECTED BY OWNER AND RATED FOR INSULATED CEILINGS WHERE NEEDED. ENSURE PROPER LOCAL SWITCHING. LIGHTING FURNISHED BY E.C. TO BE COORDINATED WITH CEILING TYPES, MECHANICAL WORK, STRUCTURAL MEMBERS, ETC. VERIFY FINISHES AND LOCATIONS OF CONTROLS. 3. COORDINATE PRE-WIRING OF T.V. COAX AND TELEPHONE JACKS WITH G.C. AND OWNER. VERIFY ALL WALL LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. 4. PROVIDE RECEPTACLE LOCATIONS AND SPACING PER N.E.C. 210-52 THROUGHOUT. FIELD ADJUSTMENTS / MEASUREMENTS ARE REQUIRED TO COMPLY. COORDINATE ADDITIONAL STUD WALL BRACING IF REQUIRED FOR RECEPTACLE PLACEMENTS WITH G.C. IF APPLICABLE, VERIFY FLOOR OUTLET LOCATIONS WITH ARCHITECT. PROVIDE GFI RECEPTACLES WHERE REQUIRED BY CODE PER NEC 210.8. 5. PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION IN DWELLING UNITS PER NEC 210.12. FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. VERIFY WITH LOCAL AUTHORITY HAVING JURISDICTION IF EXISTING BRANCH CIRCUITS SHALL COMPLY WITH NEC 210.12. 6. ALL CLOSET LIGHTING SHALL COMPLY WITH NEC 410.16. 7. ALL ELECTRICAL DEVICES AND LIGHT FIXTURE MOUNTING HEIGHTS SHALL COMPLY TO THE "FAIR HOUSING ACT": DUPLEXES +15" A.F.F., SWITCHES AT +46" A.F.F. VERIFY WITH OWNER. 8. FOR NEW RECEPTACLES, PROVIDE TAMPER RESISTANT RECEPTACLES THROUGHOUT DWELLING UNIT AS REQUIRED BY NEC 406.12 9. PROVIDE ACCURATE AND LEGIBLE PANEL INDEXES IDENTIFYING SPECIFIC PURPOSE OR USE OF CIRCUIT BREAKERS PER NEC 408.4. NOTE: UNLESS OTHERWISE NOTED, ALL NEW RECEPTACLES SHALL MATCH EXISTING ELEVATIONS (AFF) NOTE: NOT ALL EXISTING RECEPTACLES ARE SHOWN. THOSE SHOWN ARE FOR REFERENCE AND ARE IN THE AREA OF CONSTRUCTION. DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED OR RELOCATED. DETAIL NOTES - POWER: ADDITIONAL LEGEND - POWER: GENERAL NOTES - POWER: 1 RE-USE EXISTING CIRCUITRY MADE AVAILABLE THROUGH DEMOLITION / RELOCATION. CONNECT TO EXISTING 120V. RECEPTACLE / CIRCUIT. NEW LOCATION FOR POWDER ROOM RECEPTACLE. RE-CONNECT TO EXISTING 120V. CIRCUIT. NEW HEAT MAT IN MASTER BATHROOM. RE-USE EXISTING CIRCUIT (PP-CD10-40) PROVIDE ADD ALTERNATE PRICING: NEW HEAT MAT IN SHOWER. CONNECT TO EXISTING HEAT MAT CIRCUIT IN MASTER BATHROOM. NEW HEAT MAT IN THIS BATHROOM. NEW MAKE UP AIR UNIT. 208V., 3ɸ, 16KW. NEW SUPPLY FAN "SF-1" 120V., 1ɸ, 301 WATTS. REFER TO MECHANICAL DRAWINGS FOR INTERLOCKING INFORMATION WITH "MAU-1" AND "KEH-1". "KEH-1" 120V., 1ɸ, 8.5 AMPS PROVIDE NEW FLUSH MOUNTED PANEL "PP-CD10A". PROVIDE 18 CIRCUITS PANEL. COORDINATE LOCATION WITH OWNER AND ARCHITECT. EXISTING FIREPLACE TO BE REPLACED WITH NEW FIREPLACE UNIT. RE-USE EXISTING CIRCUITS FOR IGNITER. COORDINATE EXACT REQUIREMENTS WITH VENDOR PRIOR TO DEMOLITION AND INSTALLATION. EXISTING STEAM GENERATOR IN MASTER BATH TO BE REMOVED AND REPLACED WITH NEW UNIT "SGU-1". REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 208V., 1PH, 15 KW. REFER TO PANEL INDEXES FOR ADDITIONAL INFORMATION. (N) = NEW FIXTURE (R) = RELOCATED 2 3 4 4a FLOOR FOURLEX RECEPTACLE 5 6 7 8 9 10 11 ISSUE DATE UNIT 9203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO JMM CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED C3S, TNS UNIT 9203 REMODEL SEAL & SIGNATURE: CLIENT: Tim & Nancy Buese Unit 9203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Duet Design Group, LLC 901 ACOMA SUITE 200 DENVER, CO 80204 t. 303-783-9327 miranda@duetdesigngroup.com MECH/PLUMBING ENGINEER: Rader Engineering PO BOX 8610 AVON, CO 80620 t. 970-845-7910 BryanH@raderengineering.com ELECTRICAL ENGINEER: C3S Incorporated 1737 CENTRAL STREET SUITE 201 DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com LIGHTING DESIGN: 186 Lighting Design Group, Inc. 1200 BANNOCK STREET DENVER, CO 80204 t. 303-534-5350 gmackell@186group.com KITCHEN DESIGN: exquisite kitchen design 601 SOUTH BROADWAY SUITE F DENVER, CO 80209 303-282-0382 mikalo@myekdesign.com 16-27 1 FOR PERMIT 02/22/2017 2/22/17 OF 22 REVISION 5/5/17 1 POWER PLAN 19E-200 SCALE: 1/4" = 1'-0" 1 POWER PLAN - UNIT 9203 1 1 06/06/17