HomeMy WebLinkAboutB17-0027_E-300_1490802540.pdfS S BATH 3 109 BED 3 108 MUD ROOM 113 SKI CLOSET 115 POWDER 114 LIVING ROOM 104 BED 2 110 BATH 2 111 MASTER BED 105 MASTER BATH 106 KITCHEN 101 DINING ROOM 102 ENTRY 100 HALLWAY 107 SITTING 103 HALLWAY 112 TYP: LAMP DIMMER PLUGGED INTO HOT OUTLET FOR ON-SYSTEM LAMP CONTROL LED STRIP IN SHADE POCKET UNDER COUNTER SJS 48" 48" 48" 24" JS L4 A2 A1 A1 A1 L1 L3 C1 L1C L1C L1C L5 L3 L3 L3 A1 A2 A1 A2 A1 A1 A1 A1 L1C L3 L3 L1C L2 L2 L4 A2 L1 L1 A2 A2 A2 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A1 A1 A1 L5 A2 L1 L1 A1 A1 A1 A1 A1 A1 A1F A1 L2 L1 W W A2 A2 L5 L5 A2 A2 A1 A1 A2 A2 A2 A2 W W A2 A1 A1 A1 A1 A1 W W A2 A2 A1 A1 A1 A1 A1 A1 A2 P L5 L1 L1 L1 L1 A1 A1 A1 A2 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A1 A1 A1 A1 A1 A1 A1 A2 L4 A2 A2 A2 A1 A1 A1 A1 A1 A1 A1 A1 M1 SJS SJS SJS (E) S JSSJS SJS (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 101-00 101-01 114-00 114-01 114-02 113-02 113-01 115-00 115-01 115-02 108-01 108-00 110-01 110-00 114-03 112-00 114-04 100-00 100-01 102-01 110-02 108-02 105-01 105-02 105-05 105-04 105-03 105-06 105-07 105-08 105-09 105-10 103-11 104-01 104-07 104-08 106-00 106-01 106-02 106-03 106-04 106-05 106-06 106-08 106-09 106-07 108-03 110-03 101-02 110-04 108-04 100-02 109-00 109-01 109-02 109-03 109-04 111-00 111-01 111-02 111-03 FP-01 102-00 104-03 104-04 104-05 104-02 104-06 103-00 103-01 103-02 107-00 107-01 101-03 101-04 101-05 104-00 100-03 113-01 113-02 112-01 114-01 115-01 110-01 110-02 108-01 108-02 109-01 111-01 105-01 105-02 105-03 105-04 105-05 106-01 106-02 100-01 101-02 104-01 107-01 104-03 101-01 104-02 103-01 EXISTING LUMINAIRE AND CIRCUITRY TO REMAIN. (TYPICAL) NOTES: ALL LIGHTING IS SHOWN IS NEW U.O.N. DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED OR RELOCATED. (E) = EXISTING (R) = RELOCATED SPEAKER CIRCUIT NUMBER 1234 VERIFY IN FIELD VIF ADDITIONAL LIGHTING LEGEND SMOKE DETECTOR, EXISTING U.O.N. NEW RECESSED DOWNLIGHT THREE WAY SWITCH SINGLE POLE SWITCH WALL MOUNTED FIXTURE, EXISTING U.O.N. NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT SD RECESSED SPRINKLER HEAD, EXISTING U.O.N. WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N. EV EMERGENCY VOICE COMMUNICATION (EVC) SYSTEM SPEAKER CEILING OR WALL MOUNTED. EXISTING U.O.N. CEILING FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. RECESSED FIXTURE, EXISTING U.O.N. NEW WALL MOUNTED FIXTURE NEW RECESSED WALL WASH EXISTING EXHAUST FAN, NO CHANGE LOW VOLTAGE OR LED STRIP ACCESS PANEL DOOR JAMB SWITCH NEW RECESSED ADJUSTABLE ACCENT KEYPAD RF TABLETOP KEYPAD RF LAMP DIMMER - PLUG INTO HOT OUTLET NEW HANGING PENDANT OR CHANDELIER RECESSED LINEAR LIGHT SURFACE-MOUNTED LINEAR LIGHT 48" W P S3 S SJS GENERAL NOTES - LIGHTING 1. COORDINATE ALL LOCATIONS OF LUMINAIRES AND WALLBOX CONTROLS WITH INTERIOR DESIGNER AND OWNER PRIOR TO ROUGH-IN. 2. COORDINATE ALL CONTROLS WITH OWNER, INTERIOR DESIGNER, AND CONTROLS REPRESENTATIVE. 3. VERIFY ALL VOLTAGES AND WATTAGES OF NEW LUMINAIRES PRIOR TO ROUGH-IN. ENSURE ADDED LUMINAIRES TO EXISTING 120V BRANCH LIGHTING CIRCUIT DO NOT EXCEED BREAKER CAPACITY PER NEC. 4. COORDINATE ALL LUMINAIRE SPECIFICATIONS AND DIMMING REQUIREMENTS WITH LUTRON REPRESENTATIVE PRIOR TO PURCHASING TO ENSURE LUMINAIRES ARE COMPATIBLE WITH EXISTING SYSTEM. 5. VERIFY MOUNTING HEIGHTS AND LOCATIONS OF NEW LUMINAIRES WITH ARCHITECT / INTERIOR DESIGNER PRIOR TO ROUGH-IN. 6. REFER TO ARCHITECTURAL AND LIGHTING DESIGNER'S DRAWINGS FOR FIXTURE SPECIFICATIONS. COORDINATE WITH LIGHTING DESIGNER AND INTERIOR DESIGNER FOR EXACT LOCATIONS OF LUMINAIRES PRIOR TO ROUGH-IN. THESE PLANS DO NOT PROVIDE EXACT MOUNTING INFORMATION. ISSUE DATE UNIT 9203 FOUR SEASONS RESORT & RESIDENCES VAIL, CO JMM CHK BY: SCALE: SHEET: JOB #: DRW BY: TITLE: DATE: COMMENT AS NOTED C3S, TNS UNIT 9203 REMODEL SEAL & SIGNATURE: CLIENT: Tim & Nancy Buese Unit 9203 FOUR SEASONS VAIL 1 Vail Road VAIL, CO 81657 ARCHITECT: Creative Design Associates 434 BROADWAY, 5TH FLOOR NEW YORK, NY 10013 t. 212-748-8900 WESTERN US 4700 E BROMLEY LN, SUITE 105 BRIGHTON, CO 80601 t. 646-747-2171 c. 917-756-0057 dsorenson@ralcompanies.com INTERIOR DESIGN: Duet Design Group, LLC 901 ACOMA SUITE 200 DENVER, CO 80204 t. 303-783-9327 miranda@duetdesigngroup.com MECH/PLUMBING ENGINEER: Rader Engineering PO BOX 8610 AVON, CO 80620 t. 970-845-7910 BryanH@raderengineering.com ELECTRICAL ENGINEER: C3S Incorporated 1737 CENTRAL STREET SUITE 201 DENVER, CO 80211 t. 303-480-5144 theresa@c3sengineeringinc.com LIGHTING DESIGN: 186 Lighting Design Group, Inc. 1200 BANNOCK STREET DENVER, CO 80204 t. 303-534-5350 gmackell@186group.com KITCHEN DESIGN: exquisite kitchen design 601 SOUTH BROADWAY SUITE F DENVER, CO 80209 303-282-0382 mikalo@myekdesign.com 16-27 1 FOR PERMIT 02/22/2017 2/22/17 OF 22 LIGHTING PLAN 20E-300 SCALE: 1/4" = 1'-0" 1 LIGHTING PLAN - UNIT 9203 NOTE: LUMINAIRES SELECTED BY LIGHTING DESIGNER AND INTERIOR DESIGNER. THIS INFORMATION APPEARS ON THIS SET FOR INFORMATION ONLY. FOR CLARIFICATIONS, CONTACT LIGHTING AND INTERIOR DESIGNER. 03/29/17