HomeMy WebLinkAboutB17-0027_E-300_1496780520.pdfS
S
BATH 3
109
BED 3
108
MUD ROOM
113
SKI
CLOSET
115
POWDER
114
LIVING
ROOM
104
BED 2
110
BATH 2
111
MASTER
BED
105
MASTER
BATH
106
KITCHEN
101
DINING
ROOM
102
ENTRY
100
HALLWAY
107
SITTING
103
HALLWAY
112
UNDER COUNTER
SJS
48"
48"
48"
24"
FL1
A2F
A1F
A1F
L1
L3
C1
L3
L3
L3
A3 A3 A3 A3
L3
L3
L1C
A2F
L1
L1
A3
A3
A3 A3
A3
A3 S1
A3
L1
W
W
A2F
A3
A2F
A1F
A1F A2F
A2F A2F
A2F
W W
A3 S1
S1
A3 A3 A3
W W
A3
S1
S1
S1
A3
A2F
P
L1
L1
L1
A2F
A1F
A1F
A1F
A1F
A1F
A1F
A2
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1
A1
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A1F
A2F
A1F
A1F
A1F A1F A1F
A2F
L4
A2F
A2F
A2F
A1F
A1F
A1F
A1F
A1F A1F
A1F
A1F
SJS
SJS
(E) S
JSSJS
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
04
22
17
F-04
25
20
07
08
09
F-01
24
14
11
01
05
110-04
LD-01
18
28
F-02
F-03
19
FP-01
LD-04
LD-03
103-02
13
03
LD-02
113-01
113-02
112-01
114-01
115-01
110-01
110-02
108-01
108-02
109-01
111-01
105-01
105-02
105-03
105-04
105-05
106-01
106-02
100-01
101-02
104-01
107-01
104-03 101-01
104-02
103-01
EXISTING LUMINAIRE AND
CIRCUITRY TO REMAIN. (TYPICAL)
S1
A3
FL1 A3
A3
A3
A3
31
360° BACKLIT MIRROR
REGRESSED CLOCK
OUTLET FOR FUTURE
ART LIGHTS
30
VERIFY WALL KEYPAD
OR TABLETOP
A3
C1
15
C1 C1
16
INVERSE COVE AT FIRE
PLACE WALL TRANSITIONS
TO LED STRIP UPLIGHT AT
WINDOWS
LED TRIP TOEKICK
REGRESSED CLOCK
OUTLET FOR FUTURE
ART LIGHTS
06
TRIMLESS LINEAR LED STRIP
21
HOOD WITH INTEGRAL
LIGHTING AND
EXHAUST
26
SURFACE MOUNT DECORATIVE
TO BE COORDINATED WITH
ACCESS PANEL
27
A3
A3 A3 A3 A3
23
02
TO A1F & A2F.
ECOSYSTEM
L1C
TYPICAL FOR ALL SHALLOW CLOSETS: LENSED STRIPLIGHT
ABOVE DOOR HEADER, ON JAMB SWITCH. VERIFY IN FIELD
WHICH CLOSETS TO RECEIVE NEW FIXTURE.
LED STRIP UNDER
FLOATING VANITY
S
JS
FL1
SJS
A1F
A1F
HIDDEN LED STRIP TO
ILLUMINATE STONE
NOTES:
ALL LIGHTING IS SHOWN IS NEW U.O.N.
DASHED FIXTURES INDICATES EXISTING TO BE REMOVE / DEMOLISHED OR
RELOCATED.
(E) = EXISTING (R) = RELOCATED
SPEAKER
CIRCUIT NUMBER
1234
VERIFY IN FIELD
VIF
ADDITIONAL LIGHTING LEGEND
SMOKE DETECTOR, EXISTING U.O.N.
NEW RECESSED DOWNLIGHT
THREE WAY SWITCH
SINGLE POLE SWITCH
WALL MOUNTED FIXTURE, EXISTING U.O.N.
NEW SURFACE MOUNTED LIGHT FIXTURE/PENDANT
SD
RECESSED SPRINKLER HEAD, EXISTING U.O.N.
WALL MOUNTED SPRINKLER HEAD, EXISTING U.O.N.
EV EMERGENCY VOICE COMMUNICATION (EVC) SYSTEM
SPEAKER CEILING OR WALL MOUNTED. EXISTING U.O.N.
CEILING FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
RECESSED FIXTURE, EXISTING U.O.N.
NEW WALL MOUNTED FIXTURE
NEW RECESSED WALL WASH
EXISTING EXHAUST FAN, NO CHANGE
LOW VOLTAGE OR LED STRIP
ACCESS PANEL
DOOR JAMB SWITCH
NEW RECESSED ADJUSTABLE ACCENT
KEYPAD
RF TABLETOP KEYPAD
RF LAMP DIMMER - PLUG INTO HOT OUTLET
NEW HANGING PENDANT OR CHANDELIER
RECESSED LINEAR LIGHT
SURFACE-MOUNTED LINEAR LIGHT 48"
W
P
S3 S
SJS GENERAL NOTES - LIGHTING
1. COORDINATE ALL LOCATIONS OF LUMINAIRES AND WALLBOX
CONTROLS WITH INTERIOR DESIGNER AND OWNER PRIOR TO
ROUGH-IN.
2. COORDINATE ALL CONTROLS WITH OWNER, INTERIOR DESIGNER,
AND CONTROLS REPRESENTATIVE.
3. VERIFY ALL VOLTAGES AND WATTAGES OF NEW LUMINAIRES PRIOR
TO ROUGH-IN. ENSURE ADDED LUMINAIRES TO EXISTING 120V
BRANCH LIGHTING CIRCUIT DO NOT EXCEED BREAKER CAPACITY
PER NEC.
4. COORDINATE ALL LUMINAIRE SPECIFICATIONS AND DIMMING
REQUIREMENTS WITH LUTRON REPRESENTATIVE PRIOR TO
PURCHASING TO ENSURE LUMINAIRES ARE COMPATIBLE WITH
EXISTING SYSTEM.
5. VERIFY MOUNTING HEIGHTS AND LOCATIONS OF NEW LUMINAIRES
WITH ARCHITECT / INTERIOR DESIGNER PRIOR TO ROUGH-IN.
6. REFER TO ARCHITECTURAL AND LIGHTING DESIGNER'S DRAWINGS
FOR FIXTURE SPECIFICATIONS. COORDINATE WITH LIGHTING
DESIGNER AND INTERIOR DESIGNER FOR EXACT LOCATIONS OF
LUMINAIRES PRIOR TO ROUGH-IN. THESE PLANS DO NOT PROVIDE
EXACT MOUNTING INFORMATION.
ISSUE DATE
UNIT 9203
FOUR SEASONS
RESORT & RESIDENCES
VAIL, CO
JMM
CHK BY:
SCALE:
SHEET:
JOB #:
DRW BY:
TITLE:
DATE:
COMMENT
AS NOTED
C3S, TNS
UNIT 9203
REMODEL
SEAL & SIGNATURE:
CLIENT:
Tim & Nancy Buese
Unit 9203
FOUR SEASONS VAIL
1 Vail Road
VAIL, CO 81657
ARCHITECT:
Creative Design Associates
434 BROADWAY, 5TH FLOOR
NEW YORK, NY 10013
t. 212-748-8900
WESTERN US
4700 E BROMLEY LN, SUITE 105
BRIGHTON, CO 80601
t. 646-747-2171
c. 917-756-0057
dsorenson@ralcompanies.com
INTERIOR DESIGN:
Duet Design Group, LLC
901 ACOMA SUITE 200
DENVER, CO 80204
t. 303-783-9327
miranda@duetdesigngroup.com
MECH/PLUMBING ENGINEER:
Rader Engineering
PO BOX 8610
AVON, CO 80620
t. 970-845-7910
BryanH@raderengineering.com
ELECTRICAL ENGINEER:
C3S Incorporated
1737 CENTRAL STREET SUITE 201
DENVER, CO 80211
t. 303-480-5144
theresa@c3sengineeringinc.com
LIGHTING DESIGN:
186 Lighting Design Group, Inc.
1200 BANNOCK STREET
DENVER, CO 80204
t. 303-534-5350
gmackell@186group.com
KITCHEN DESIGN:
exquisite kitchen design
601 SOUTH BROADWAY SUITE F
DENVER, CO 80209
303-282-0382
mikalo@myekdesign.com
16-27
1 FOR PERMIT
02/22/2017
2/22/17
OF 22
REVISION
5/5/17 1
LIGHTING PLAN
20E-300
SCALE: 1/4" = 1'-0" 1 LIGHTING PLAN - UNIT 9203
NOTE:
LUMINAIRES SELECTED BY LIGHTING DESIGNER AND INTERIOR DESIGNER. THIS INFORMATION APPEARS ON THIS SET FOR INFORMATION ONLY. FOR
CLARIFICATIONS, CONTACT LIGHTING AND INTERIOR DESIGNER.
1
1
06/06/17