HomeMy WebLinkAboutB17-0224_A4.1_1508449980.pdfMAIN LEVEL
8369' - 6"
UPPER LEVEL
8380' - 6"
BASEMENT
8358' - 6"
2
A4.5
GARAGE PLATE
8395' - 0"
GARAGE LEVEL
8386' - 0"
5
A4.6
1
A4.5
E K D
1
A4.2
2
A4.2
8386' - 0"
2
A0.1
B302
B212b
B210a
B300 B63
B64
A301
A64
BONUS ROOM
B210
3
A4.3
A5.3
8
1
M7
A4.1
1
Sim
4
MAIN LEVEL
8369' - 6"
UPPER LEVEL
8380' - 6"
BASEMENT
8358' - 6"
2
A4.5
GARAGE PLATE
8395' - 0"
GARAGE LEVEL
8386' - 0"
5
A4.6
1
A4.5
E K
D
1
A4.2
2
A4.2
BONUS ROOM
A210
14' - 10"
B301
B60
B212b B210a
B300
B63
B64
B62
A301
A66
2-CAR
GARAGE
A301
ENTRY
B300
2-CAR
GARAGE
B301
BEDROOM 3/
OFFICE
B201
CL 3
B202
BROOM
B209
BATH 3
B212
LOUNGE
B101 MECH.
ELEV.MECH
B102
3
A4.3
A4.1
1
Sim
1
M7
4
E
OUTSIDE
DECK
INTERIOR
ROOM
INTERIOR
ROOM
OUTSIDE
PATIO
MAIN LEVEL
8369' - 6"
UPPER LEVEL
8380' - 6"
BASEMENT
8358' - 6"
GARAGE LEVEL
8386' - 0"
E
GA FILE NO. WP 3812 GENERIC 2 HOUR FIRE RATING
W/ +59 STC SOUND RATING:
BASE LAYER: 1/2" type X gypsum wallboard applied at right
angles to 2x6 (substitute) wood studs 24" o.c.with 6d coated
nails, 1 7/8" long 0.086" shank, 1/4" heads, 16" o.c.
FACE LAYER: 1/2" type x gypsum wallboard applied at right
angles to studs over base layer and to top and bottom plates
with 8d coated nails, 2 3/8" long, 0.099" shank, 9/32" heads,
8" o.c. Joints in inner layer need not be taped.
INNER LAYER: 5/8" type x gypsum wallboard applied parallel
with 6d coated nails, 1 7/8" long, 0.0915" shank, 1/4" heads,
8" o.c. Joints in inner layer need not be taped.
SECOND WALL: duplicate of first wall and seperated by
1 3/4" (substitute from 1") space. walls independently loaded.
SOUND TESTED: with 3 1/2 " glass fiber insulation, 0.75 pcf,
friction fit in stud spaces (substitute w/ 5 1/2" BIBS).
5/8" TYPE "X" GWB APPLIED TO
THE UNDER SIDE OF SIP
PANEL FOR A MIN. DISTANCE
OF 4'-0" FROM PARTY WALL
(EXCEPTION TO PARAPET
REQUIREMENT R302.2.2)
WATERPROOF
MEMBRANE FROM ROOF
TO RUN UP WALL 24" MIN.
STEP FLASHING AND COUNTER FLASHING.
SIDING TO BE KEPT OFF ROOF SURFACE BY 4"
LOT SPLIT LINE NOTES:
NO PARALLEL OPENINGS WITHIN 36" OF LOT LINE.
KEEP BOTH SIDES STRUCTURALLY INDEPENDENT
OF EACH OTHER FROM FOUNDATION TO ROOF.
NO ENCROACHMENTS WITHOUT PROPER FIRE
SEPARATION AND LEGAL OWNER AGREEMENTS.
LOT-SPLIT LINE
(CENTERLINE)
5 1/2"
1 1/2" 1 1/2"
5 1/2"
SIP PANEL ROOF
SIP PANEL ROOF
1' - 0"
3"
1' - 4 1/2"
BOTH WALLS ARE INDEPENDENTLY BEARING AND THE ROOF
AND ROOF OVERHANG IS COVERED BY 5/8" TYPE "X" GWB
PROVIDING FIRE SEPARATION PROTECTION FROM EACH
UNIT.
ALL GWB AT EXTERIOR LOCATIONS TO BE WATER RESISTANT.
KITCHEN INTERIOR
ROOM
GARAGE
INTERIOR
ROOM
INTERIOR
ROOM
INTERIOR
ROOM
INTERIOR
ROOM
2X4 FURRING WALL
FOR PLUMBING
AND GAS LINE
WATERPROOFING MEMBRANE UP WALL 8"
SOUND PROOFING LAYER OF GWB APPLIED
AFTER WATERPROOFING INSTALLED.
SOUND MITIGATION NOTE:
OUTER LAYER OF GWB TO BE:
NAT'L GYPSUM GOLD BOND SOUNDBREAK XP 5/8" GWB
OR "QUIETROCK" OR CERTAINTEED "SILENTFX"
OR SIMILAR FOR MAXIMUM STC RATING (TYP).
DRAINAGE BOARD TO DRAIN
5 1/2" BIBS INSULATION R-21 IN EACH WALL.
FLOOR FINISH BY OTHERS
BOTH LAYERS OF DRYWALL
TO RUN DIRCTLY TO BOTTOM
OF FLOOR SHEATHING
WITHIN JOIST SPACE.
FLOOR JOIST RUNNING
PARALLEL TO PARTY
WALL
FLOOR JOIST RUNNING
PARALLEL TO PARTY
WALL
FLOOR JOIST RUNNING
PARALLEL TO PARTY
WALL
FLOOR JOIST RUNNING
PARALLEL TO PARTY
WALL
FLOOR JOIST RUNNING
PARALLEL TO PARTY
WALL
BOTH LAYERS OF DRYWALL
TO RUN DIRCTLY TO BOTTOM
OF FLOOR SHEATHING
WITHIN JOIST SPACE.
BOTH LAYERS OF DRYWALL
TO RUN DIRCTLY TO BOTTOM
OF FLOOR SHEATHING
WITHIN JOIST SPACE.
DROPPED CEILING TO BE
INSTALLED AFTER FIRE RATED
DRYWALL IN PLACE. IN
LOCATIONS REQUIRED FOR
LIGHTING FIXTURES AND
SPRINKLER PIPES.
NO PROJECTIONS (ROOF
OVERHANG) ALLOWED
WITHIN 2 FT OF PROPERTY
LINE.
EXTERIOR WALLS LESS THAN 3 FT. FROM PROPERTY
LINE SHALL BE ONE-HOUR RATED (1 LAYER EXTERIOR
GRADE 5/8" TYPE X DRYWALL EACH SIDE OF WALL
CONTINUOUS TO BOTTOM OF SIP PANEL SHEATHING)
AND WITH NO OPENINGS.
TABLE R302.2(2) DWELLINGS WITH FIRE SPRINKLERS.
SIP PANEL TIGHT TO WALL
4 970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Date
Studio M Engineers, LLC
308 N. Hyland Park Dr. Glenwood
Springs, CO 81601 970-366-8690 cell www.mbengineering.elementfx.com REVISIONS
9/12/2017
2:47:03 PM
A4.1
CROSS
SECTIONS
KATSOS
DUPLEX
PERMIT
SET
6-12-17
8-8-17
DUPLEX
3230
Katsos
Ranch
Road
Vail, Colorado
1/4" = 1'-0"
2 CROSS SECTION 2 - GARAGE @ S
1/4" = 1'-0"
3 CROSS SECTION 3 GARAGE @ N
3/4" = 1'-0" 4 PARTY WALL SECTION 1
3/4" = 1'-0"
1 PARTY WALL SECTION 2
No. Description Date
2 PERMIT
REVS
ROUND 1 8-3-17
3 PERMIT
REVS
ROUND 2 8-23-17
4 PERMIT
REVS
ROUND 3 9-12-17
PERMIT SET 6-12-17PERMIT
SET 6-12-17STUCCO OVER
SHEARWALL SHEATHING
LVL W/ SLOPING TOP
STEEL BEAM
(STRUCTURALLY SEPERATE
FROM OTHER UNIT)
STUCCO OVER
SHEARWALL SHEATHING
SEE GA FILE WP
3812 FOR
ASSEMBLY RATING
2
2
SUBSTITUTION NOTE:
SUBSTITUTE GLASS FIBER INSULATION FOR
5 1/2" BIBS INSULATION .
NOTE: ALL GRADES TO SLOPE
POITIVELY AWAY FROM
PERIMETER OF BUILDING.
3
Property line separation to be reviewed by
the Town of Vail (AHJ)
10/19/17