Loading...
HomeMy WebLinkAboutB17-0282_DA103_1507064742.pdfNORTH 1/4" = 1'-0" 1LEVEL 3 DEMOLITION PLAN MASTER BEDROOM MASTER CLOSET TUB STAIRS DECK DECK DECK STUDIO BED PLATFORM BATH KITCHEN DECK DECK DECK BELOW DECK BELOW DECK STAIRS STAIRS EXISTING CONSTRUCTION TO REMAIN; NO WORK IN THESE AREAS EXCEPT AS OTHERWISE REQ'D IN DRAWINGS & SPECIFICATIONS. REMOVE THESE PORTIONS OF EXISTING CONSTRUCTION. 1. FOR EXISTING WALLS TO REMAIN, DEMO DOWN TO STUDS & STRUCTURAL SHEATHING. 2. REMOVE EXISTING FINISH FLOOR MATERIALS DOWN TO PLYWOOD SUBFLOOR (EXCEPT IN AREAS MARKED "NO WORK.") 3. RE: STRUCTURAL, MEP, AND CIVIL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL ALTERATIONS & DEMOLITION. 4. PROTECT EXISTING CONSTRUCTION TO REMAIN DURING DEMOLITION AND OTHER PHASES OF WORK. 5. NOTIFY ARCHITECT PRIOR TO DRILLING, CUTTING, OR OTHERWISE MODIFYING ANY STRUCTURAL MEMBER NOT IDENTIFIED IN DRAWINGS. 6. VERIFY EXISTING CONDITIONS IN FIELD AND NOTIFY ARCHITECT OF ANY DISCREPANCIES ENCOUNTERED PRIOR TO PROCEEDING WITH WORK. 7. CONTRACTOR SHALL ENSURE WEATHER PROTECTION OF EXISTING STRUCTURE TO REMAIN THROUGHOUT THE DURATION OF DEMOLITION AND CONSTRUCTION. 8. REFER TO SPECIFICATIONS FOR ADDITIONAL DEMOLITION REQUIREMENTS. 9. COORDINATE ALL SLAB REMOVAL WITH STRUCTURAL DRAWINGS & SPECIFICATIONS. 10. THE EXISTING BUILDING MAY CONTAIN ASBESTOS OR PRODUCTS CONTAINING ASBESTOS, A SUBSTANCE KNOWN TO PRESENT HEALTH HAZARDS. THE ARCHITECT'S SCOPE OF SERVICES FOR THIS PROJECT DOES NOT INCLUDE ANY SERVICES RELATED IN ANY WAY TO ASBESTOS. SHOULD ANY PARTY ENCOUNTER SUCH MATERIALS ON THE JOBSITE, OR SHOULD IT IN ANY OTHER WAY BECOME KNOWN THAT SUCH MATERIALS ARE PRESENT OR MAY BE PRESENT AT THE JOBSITE OR ANY ADJACENT AREAS WHICH MAY AFFECT THE JOBSITE OR ANY ADJACENT AREAS WHICH MAY AFFECT THE ARCHITECT'S SERVICES, THE OWNER AND CONTRACTOR SHALL ABATE, ENCAPSULATE, AND / OR REMOVE THE ASBESTOS OR ASBESTOS CONTAINING MATERIALS AND WARRANT THAT THE JOBSITE IS IN FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS, INCLUDING MEASURES FOR THE PROTECTION OF THE CONTRACTOR OR ANY SUBCONTRACTOR, OR FOR THE PROTECTION OF THE PUBLIC. SUCH RESPONSIBILITY FOR SAFETY PRECAUTIONS IS AND SHALL REMAIN THAT OF THE OWNER AND CONTRACTOR. OBSERVE AND ADHERE TO ALL APPLICABLE LAWS AND REGULATIONS REGARDING WORKER PROTECTION AND PROPER REMOVAL OF THESE BUILDING MATERIALS (INCLUDING BUT NOT LIMITED TO OSHA AND COLORADO DEPARTMENT OF HEALTH & ENVIRONMENT). D E M O L I T I O N N O T E S REMOVE ROOF BELOW, TYP. BALCONY BELOW, RE: 1/DA102 TYP. REMOVE ROOF BELOW, TYP. REMOVE ROOF ABOVE, TYP. REMOVE ROOF ABOVE, TYP. REMOVE ALL LEVEL 3 FLOOR FRAMING, RE: STRUC. MM KK JJ II GG EEA EE CC AA A B 3 5 Z YA Y XN X 15 ZA 6A K.5 13.5 8'-0" 4'-0" 4'-0" 8'-0" 3'-91 2" 4'-21 2" 8'-0" 8'-0" 4'-0" 4'-0" 4'-0" 3'-0" 9'-712" 4'-412" 9'-712" 4'-412" 4'-712" 1'-312" 3'-1" 8'-0" 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" C D E F G H I J K L M 4'-0" 2 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" E.5 2'-0" 2'-0" 4'-0" 2'-0" 2'-0" L.5 2'-0" 2'-0" 2'-0" 2'-0" DEMO SOUTHERN 4' OF CHIMNEY ABOVE FAMILY ROOM CEILING, NO CHANGE TO EXISTING LOCATION OF WOOD BURNING FLUE DEMO WESTERN 1'-8" OF CHIMNEY ABOVE LIVING ROOM CEILING, NO CHANGE TO EXISTING LOCATION OF WOOD BURNING FLUE DA103 DEMO PLAN LEVEL 3 OWNER 43-45 RIVA RIDGE LLC 950 WINTER ST, #4600 WALTHAM, MA 02451 PROJECT NO.: 21074.00 ISS.# DESCRIPTION DATE VAIL, COLORADO 81657 311 BRIDGE STREET LANDSCAPE SHERRY DORWARD P.O. BOX 3766 VAIL, CO 81658 ARCHITECT ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT. STUITE 117 DENVER, CO 80216 HILL BUILDING RENOVATION 39°38'24"N 106°22'25"W STRUCTURAL MONROE NEWELL 70 BENCHMARK RD. SUITE 204 AVON, CO 81620 ENGINEER MEP DMCE ENGINEERING 5737 6TH AVE. LAKEWOOD, CO 80214 ENGINEER CIVIL ALPINE ENGINEERING, INC. 34510 HIGHWAY 6 UNIT A-9 EDWARDS, CO 81632 ENGINEER TOWN OF VAIL USE OWNER MT. BELVEDERE 45 LLC 950 WINTER ST, #4600 WALTHAM, MA 02451 01 BUILDING PERMIT ISSUE 2017-07-21 10/03/17